• 제목/요약/키워드: Room Air Ventilation

검색결과 250건 처리시간 0.035초

터보냉동기의 HCFC-123 누출에 대한 수치해석 연구 (Numerical Study on the HCFC-123 Leak in Turbo Chiller by using CFD)

  • 서회경;송세욱;황양인;하현철
    • 한국가스학회지
    • /
    • 제18권5호
    • /
    • pp.85-90
    • /
    • 2014
  • 대용량의 공기조화용으로 널리 사용되는 터보냉동기는 냉매로 HCFC-123 가스를 주로 사용하며, HCFC-123은 CFC계 프레온의 대체 냉매제로 독성은 낮으나 환기가 원활하지 않는 밀폐공간이나 작업공간에서 산소결핍으로 인한 질식재해를 유발할 수 있는 것으로 보고되고 있다. 본 연구에서는 2011년 대형할인마트 기계실 내부 터보냉동기 냉매 누출로 인해 작업자 4명이 질식 등의 사유로 사망한 재해 사례를 대상으로 전산유체역학을 이용하여 HCFC-123 누출에 따른 산소농도를 예측함으로써 프레온 가스 누출사고에 대한 원인을 조사하고 대응책을 제시하여 동종 재해의 재발 방지에 도움이 되고자 한다.

바닥재로부터 방출되는 휘발성유기화합물과 폼알데하이드 특성 (Characteristics of VOCs and Formaldehyde Emitted from Floorings)

  • 박현주;장성기;서수연;임준호
    • 한국대기환경학회지
    • /
    • 제25권1호
    • /
    • pp.38-45
    • /
    • 2009
  • Since the seventies and the oil crisis, energy-saving measures have led to a reduction in the ventilation of room. The use of synthetic materials which emit various chemical substances had led to an increase in the concentration of indoor pollutants. "Sick building syndrome (SBS)" and "Sick house syndrome (SHS)" are worldwide problems. Also, the number of complaints about indoor air pollution caused by VOCs (Volatile organic compound) and HCHO (Formaldehyde) has increased. It is important that evaluating and understanding emission of indoor air pollutant from building materials. The object of this study was to evaluate emission test method for flooring such as wood based flooring, carpet tile, rubber tile, PVC sheet and tile, and to determine emission of TVOC and form-aldehyde. The quantity of TVOC and carbonyl compounds emission were sampled and measured by Tenax TA and gas chromatography/mass spectrometry (GC/MSD), 2,4-DNPH cartrige with ozone scrubber and high performance liquid from flooring. The TVOC concentration emitted from carpet tile was ($7.419\;mg/m^2 h$) the highest among 5 groups of test materials. In wood based flooring and PVC tile, the emitted concentration of toluene was high. And the dodecane emission was highest in carpet. The concentration of TVOC decreased by an increase in emission test period. After 7 days, the concentration of TVOC from floorings were about 50% below of the concentration at the first day. TVOC emission from wood based flooring, carpet tile, rubber tile, PVC sheet and tile were decreased in 28 days and remained steady after about 15 days. The concentration of formaldehyde emission from floorings showed extremely low.

겨울철 냉기를 이용한 벼의 저온저장 (II) - 빈상부 쿨링시스템을 이용한 냉각 벼의 저온저장 특성 - (Low Temperature Storage of Rough Rice Using Cold-Air in Winter (II) - Low Temperature Storage Characteristics of Rough Rice Using a Cooling System in the Top of a Bin -)

  • 이재석;홍현기;리혁;박종수;함택모;한충수
    • Journal of Biosystems Engineering
    • /
    • 제32권1호
    • /
    • pp.13-19
    • /
    • 2007
  • Storage rough rice in low temperature using the winter cold air avoids rough rice temperature increase which happens from early May, and this is possible by installing a cooling system in the top of a bin, the room between top rice level and bin ceiling. The research objective is to establish low temperature rough rice storage technique, furnishing winter cold air to rough rice, by investigating the cooling system potential of maintaining low rough rice temperature and by analyzing rough rice storage characteristics over a storage period. The rough rice storage characteristics were evaluated from January to August 2003, using a storage and dry bin of 400-ton capacity. Results of this research are as follows: Cooling bin using the cooling system in the top of the bin maintained the rice temperature less than 15$^{\circ}C$ in entire portions in August. Moisture contents and germination rates of rough rice were decreased over the storage period, on the other hand, the rough rice stored in the ambient temperature bin had relatively lower moisture contents and germination rates to compare with the bin using winter cold air. Crack ratio and acid value of brown rice in the ambient temperature bin storage had increased more than the cooling bin storage. The result indicates that the storage bin using winter cold air and the cooling system maintains moisture content and germination of rice, minimizes cracked kernel and acid value, and preserves rice quality as well.

초음파 조직생검 시 실내의 포름알데히드(HCHO) 농도 변화 관찰 (Observation of Changes in Indoor Formaldehyde(HCHO) Concentration during Ultrasound Guided Biopsy)

  • 이훈정;강성진
    • 한국방사선학회논문지
    • /
    • 제15권7호
    • /
    • pp.1057-1064
    • /
    • 2021
  • 본 연구는 초음파 조직검사 시에 실내 공기 중 HCHO 농도변화를 관찰하고자 실제 조직검사와 동일한 환경조건을 모사하여 진행하였다. 초음파 검사실의 밀폐, 환기, 포르말린 용기 개봉, 포르말린 용기 밀봉, 재환기의 다섯 단계를 연속적으로 진행하며 실내의 HCHO 농도변화를 측정하였다. 측정한 HCHO 농도변화는 그래프를 이용하여 시각화하였다. 3회에 걸쳐 측정된 농도 변화값의 일치도를 급내상관계수를 이용하여 분석한 결과, 상관계수 값이 0.989로 통계적으로 유의한 결과를 나타내었다(p<0.05). 연구 결과를 토대로 영상의학적 검사 분야에서 HCHO의 노출 환경 내에 근무하고 있는 의료종사자들 스스로 업무 중 노출 관리 필요성에 대한 인식개선과 더불어 노출 관리를 위한 환경구축 및 대책 마련에 대하여 적극적인 논의가 이루어지길 바란다.

Passive Sampler를 이용한 유물 전시관내 폼알데하이드 농도 모니터링 (Monitoring of Formaldehyde Concentration in Exhibition Hall Using Passive Sampler)

  • 이선명;임보아;김서진
    • 보존과학회지
    • /
    • 제33권5호
    • /
    • pp.319-329
    • /
    • 2017
  • 이 연구에서는 Passive sampler를 이용하여 연구대상으로 선정된 2곳의 유물 전시관 내부의 폼알데하이드 농도를 2012년 5월부터 2013년 4월까지 1년간 공간별로 모니터링 하였다. 이 결과, 유물 전시관 내부의 폼알데하이드 농도는 외기에 비해 5배~36배 이상 높은 수치를 나타냈다. 각 전시실과 진열장 내부는 오염원, 공기조화설비, 환경관리에 따라 농도 수준을 달리하였다. 유물 전시관 내 폼알데하이드 농도 수준을 주시험법에 준하여 보정한 결과, 대부분이 환경부의 실내공기질 관리법에서 고시하는 전시실 유지기준($100{\mu}g/m^3$) 뿐만 아니라 일본 국립동경박물관에서 권고하는 문화재 보존환경 기준(약 $50{\mu}g/m^3$)을 모두 초과하였다. 전시실과 진열장 내 폼알데하이드의 농도는 모두 여름>가을>봄>겨울 순으로 높았으며 온 습도가 높은 여름철에 농도 방출량이 증가하였다. 온 습도환경 변화에 따른 폼알데하이드의 농도는 모두 양의 상관관계를 나타냈다. 온도의 경우 $R^2$값이 0.8~0.9의 범위로 폼알데하이드 농도가 습도에 비해 온도에 대한 의존 경향이 큰 것을 알 수 있다. 유물 전시관 내 폼알데하이드 방출 특성 분석은 실내공기질을 개선하는데 기초자료로 활용될 수 있을 것이다.

마이크로프로쎄서를 이용한 과채류 자동 저장 제어장치의 제작과 온도 자동계측 관리 시스템 (Development of Microprocessor-based Automatic Storage Controller and Temperature Auto-measurement System for Horticultural Crops)

  • 박제균;전재근;이승구;김공환
    • 한국식품과학회지
    • /
    • 제20권6호
    • /
    • pp.845-849
    • /
    • 1988
  • 저장실, 저장상자, 공기분배장치 등을 포함한 실험실 규모의 저장실을 설계, 제작하였다. 과실류를 수용할 수 있는 저장상자(1.7 l)는 투명아크릴을 재질로 일정 공기가 계속해서 순환되도록 하고 저장실은 $0{\sim}30^{\circ}C$ 범위내에서 ${\pm}0.5^{\circ}C$의 정확도로 온도제어가 가능하였다. 저장상자로 유입되는 공기는 공기분배 장치를 통하여 예냉과 공기압의 균일화가 이루어지도록 하였고 Solenoid valve를 사용한 저장상자 선택장치를 제작하였다. 이와 같은 저장시설의 환경제어와 계측을 전담할 수 있는 마이크로프로셰서 시스템을 8 bit 마이크로프로쎄서와 기억장치, 그리고 입출력장치 등의 IC chip을 이용하여 설계 제작하였다. 동 시스템을 활용하기 위하여 저장환경의 제어를 위한 소프트웨어를 개발하고 운영프로그램을 ROM화 할 수 있었다. 제작된 저장 자동제어장치 시스템을 이용 밀감류 저장에 적용하여 저장시설의 운영 및 온도의 자료수집을 성공적으로 수행할 수 있었다.

  • PDF

교사환경기준에 관한 연구 (A Study on Environmental Standards of School Building)

  • 홍석표;박영수
    • 한국학교ㆍ지역보건교육학회지
    • /
    • 제1권1호
    • /
    • pp.11-43
    • /
    • 2000
  • The purpose of this study was, through analyzing the previous researches, to grasp the present status of environment of school building(ESB), research the sundry records of each element and, through comparative analysis of the standard of ESB in Korea, the United States, and Japan, select the normative standard of ESB, to clarify the point at issue presented in Regulation of Construction & facility Management for Elementary and and Secondary School in Korea, and to suggest an alternative preliminary standard of ESB. To carry out a research for this purpose, these were required: 1. to investigate the existing present status of ESB, 2. to make a comparative analysis of the standard of ESB in each country, 3. to suggest the normative standard of preliminary standard of ESB, 4. to analyze the controversial points of the standard of ESB in Korea, 5. to suggest an alternative preliminary standard of ESB. The conclusions were as follows: 1. Putting, through analyzing the previous researches, the existing present status of ESB together, it seemed that lighting environment, indoor air environment and noise environment were all in poor conditions. 2. In the result of a comparative analysis of the standard of ESB in Korea, Japan and the United States, in Korea the factors of each lighting and indoor air environment were not presented properly, in Japan, in lighting environment aspect, the standard on natural lighting and the factors on brightness were not presented., and in the USA the essential factors of each environment were throughly presented. In the comparison of the standards on each factor, Korea showed that the standard level presented was less properly prescribed than those of the USA and Japan but it also showed that the standard levels prescribed in the USA and in Japan were mostly similar to the standard levels in records investigated. 3. With the result of the normative standard selection on School Builiding environment factor of prescribed in this study, the controversial points of the standard of ESB in Korea were analyzed and the result was utilized to suggest new preliminary standard of ESB. 4. As the result of the analysis of the controversial points of the standard of ESB in Korea, it was found that the standard of ESB in Korea should be established on a basis of School Health Act and be concretely presented in School Health Regulation and School Health Rule. The factors of each environment was improperly presented in the existing standard of ESB in Korea. Moreover the standard of them was inferior to that of the records investigated and those of in the USA and in Japan and it also showed that the standard of it in Korea was improper to maintain Comfortable Learning Environment. 5. A suggested preliminary standard of ESB acquired through above study as follows: 1) In this study a new kind of preliminary standard of ESB is divided into lighting environment, indoor air environment, noise environment, odor environment and for above classification, reasonable factor and standard should be established and the controling way on each standard and countermeasures against it should be considered. 2) In lighting environment, the factors of natural lighting are divided into daylight rate, brightness, glare. In the standard on each factor, daylight rate should secure 5% of a mean daylight rate and 2% of a minimum daylight rate, brightness ratio of maximum illumination to minimum illumination should be under 10:1, and in glare there should not be an occurrence factor from a reflector outside of the classroom. And the factors of unnatural lighting are illumination, brightness, and glare. In the standard on each factor, illumination should be 750 lux or more, brightness ratio should be under 3 to 1, and glare should not occur. And Optimal reflection rate(%) of Colors and Facilities of Classroom which influences lighting environment should be considered. 3) In indoor air environment factors, thermal factors are divided into (1) room temperature, (2) relative humidity, (3) room air movement, (4) radiation heat, and harmful gases (5) CO, (6) $CO_2$ that are proceeded from using the heating fuel such as oval briquettes, firewood, charcoal being used in most of the classroom, and finally (7) dust. In the standard on each factor, the next are necessary; room temperature: $16^{\circ}C{\sim}26^{\circ}C$(summer : $E.T18.9{\sim}23.8^{\circ}C$, winter: $E.T16.7{\sim}21.7^{\circ}C$), relative humidity: $30{\sim}80%$, room air movement: under 0.5m/sec, radiation heat: under $5^{\circ}C$ gap between dry-bulb temperature and wet-bulb temperature, below 1000 ppm of ca and below 10ppm of $CO_2$, dust: below 0.10 $mg/m^3$ of Volume of dust in indoor air, and ventilation standard($CO_2$) for purification of indoor air : once/6 min.(about 7 times/40 min.) in an airtight classroom. 4) In the standard on noise environment, noise level should be under 40 dB(A) and the noise measuring way and the countermeasures against it should be considered. 5) In the standard on odor environment, odor level under Physical Method should be under 2 degrees, and the inspecting way and the countermeasures against it should be considered.

  • PDF

중학생의 주거 환경과 사회적 성숙도와의 관계 연구 (A Study on Relationships Between Residential Environments and the Social Maturity of Middle School Students)

  • 김세희;곽경숙
    • 한국생활과학회지
    • /
    • 제19권1호
    • /
    • pp.215-225
    • /
    • 2010
  • This study had the purpose of presenting a residential environment solution as a desirable educational environment for middle school students to grow soundly and to achieve proper self-realization while providing basic materials to build up a suitable residential environment by comparing and analyzing what relationships exist between different home backgrounds, residential environments and middle school students' social maturity. This research was conducted from Feb. 11, 2008 to Feb. 13, 2008. The subject of this research was 601 students in 3 middle schools located in Gyunggi-do. The data analyzed used the SPSS 11.5 version. The summary of this study's results is as follows. First, in terms of home background, the higher the parents' educational background and social and economic position, the greater the students' social maturity. Second, in terms of home environment, the more spacious the living space, the better the water and sewage system and rest room, the more convenient the air conditioner and kitchen system, the better the lighting, ventilation, soundproofness, insulation, the less the danger in relation to fire, crime, traffic accidents, disaster, the greater the students' social maturity. Third, in terms of the home environment related to the correlation between the residential environment and social maturity, all areas such as housing facilities, housing structural environment and housing safety showed static correlations and proved that the residential environment has an important influence on social maturity. Accordingly, in order to build up an ideal residential environment, we should make efforts to expand and improve better facilities at home considering privacy, lighting, ventilation, soundproofness, heating etc. and remove unsound factors that obstruct students social maturity and build up clean and safe residential environment with good relations with their neighbors.

개방한우사의 처마와 수직 비가림시설이 환기와 풍속 분포에 미치는 영향 (Effect of the Eave Width and the Vertical Rain Proof Facilities on Ventilation and Air Velocity Distribution in Hanwoo Loose Barn)

  • 이승주;조현준;김동훈;;장홍희
    • 농업생명과학연구
    • /
    • 제45권4호
    • /
    • pp.87-93
    • /
    • 2011
  • 본 연구는 표준 개방한우사 설계도에서 제시된 처마의 길이보다 짧게 개방한우사의 처마가 시설되었을 때 지붕의 기울기와 동일하게 처마를 연장하는 것과 기둥 위치에서 수직으로 비가림시설을 하는 경우, 어느 우사가 우의 더위 스트레스 경감, 우방 바닥 건조, 비 들이침 및 환기효율에 더 유리한지를 규명하기 위하여 표준길이의 처마와 3종의 비가림 시설을 대상으로 computational fluid dynamics (CFD) 시뮬레이션기법을 이용하여 수행하였다. 여름철의 평균 풍속인 1.2 m/s에 근거하여 시뮬레이션을 한 결과, 여러 형태로 수직 비가림시설을 설치하는 것보다 표준 처마길이로 시공하는 것이 환기 및 풍속분포가 양호하였다. 따라서 수직으로 비가림시설을 하는 것보다는 축사 표준설계도에 제시된 처마 길이 정도까지 지붕의 기울기와 같게 처마를 연장하는 것이 유리하다.

전기방사를 통해 제조된 정전기 보유 필터의 표면전위 및 대전량에 따른 성능특성 분석 (Characteristic Analysis of Electret Filters made by Electrospinning)

  • 김길태;안영철;이재근
    • 설비공학논문집
    • /
    • 제20권12호
    • /
    • pp.820-824
    • /
    • 2008
  • Electret filter media are used in general ventilation filters, disposable respirators, vehicle cabin filters, vacuum cleaners and room air cleaners. There are basic mechanisms of interception, inertial impaction, diffusion, gravitational settling, electrostatic attraction by which an aerosol particle can be deposited onto a fiber in a filter. The ability of fine particle removal strongly depends on the electrostatic forces between particles and polarized fibers. Thus, the stability of the fiber polarization is a major factor in the reliability of electret filters. In this study, the electret filter is made by electrospinning process using Polystyrene which is dissolved by 5 : 5 of Tetrahydrofuran (THF) and Dimethylformamide (DMF). Also the electrical properties and the filtration performances of electrospun filter media are Quantitatively investigated. Electrical properties of electrospun filters have been studied on surface charge potential and surface charge density. Also the filtration performance of the electret filters are evaluated on collection efficiency. The surface charge potential and the surface charge density of electrospun PS filters are increased with increasing applied voltage and saturated at 30 kV of applied voltage. Also collection efficiency of electro spun filters is increased with increasing surface charge potential and surface charge density. But the surface charge potential is decreased by natural decay and it causes deterioration of particle collection efficiency.