화장실을 이용한 층별 피난공간 확보 기술개발 (Development of Technology to Secure Refuge Space by Using Existing Restroom)

  • 김지석;신현준;김정엽;박병직
    • 설비공학논문집
    • /
    • 제27권1호
    • /
    • pp.24-30
    • /
    • 2015
  • The fire on a high-rise building would possibly cause fatalities because of ineffective egress due to extended evacuation distance in huge building structure, coupled with dense population, thus requiring secured optimal evacuation method and space. The restroom located in the living space is considered to be useful refuge space which is built with wet pipe and noncombustible materials. This study aimed to develop a system that would make use of the existing restroom as a fire refuge space. Ventilation duct were installed to discharge odor during normal conditions. We could serve the air supply duct to also raise the air pressure in the restroom so as to prevent the toxic gas from gapping around the restroom. The nozzle for the water screen would be installed in restroom door facing the living room to form the water screen which would protect the door. This study is intended to replace the existing refuge space with the restroom in such a way as described above.

실험을 통한 이동형 냉방기의 실내 온도분포 특성의 검토 (Study on Indoor Thermal Environment Controlled by Portable Cooler)

  • 최동균;송두삼;김중호
    • 설비공학논문집
    • /
    • 제28권2호
    • /
    • pp.49-54
    • /
    • 2016
  • The purpose of this study is to analyze the indoor temperature distribution of a room controlled by a personal and portable cooler. As an energy saving strategy, the personal air-conditioning or task conditioning system was developed and installed in office buildings in the 90 s. Many research results regarding the personal air-conditioning (PAC) system were focused on thermal comfort, localized ventilation efficiency and energy savings. However, the conventional PACs were only developed for application in office buildings. In this study, as a type of PAC, a portable cooler was analyzed in terms of indoor temperature distribution changes with the passage of time. The measurement was performed in a bedroom in an apartment house. The results showed that indoor temperature was controlled at about $24^{\circ}C$ around the human body. However, the ambient zone up to 1.5 m away from the the human body stayed at about $27.5^{\circ}C$.

도금공(鍍金工)에 대한 임상적(臨床的) 관찰(觀察) (Clinical Aspects among Platers)

  • 김두희
    • Journal of Preventive Medicine and Public Health
    • /
    • 제10권1호
    • /
    • pp.16-24
    • /
    • 1977
  • ${\ulcorner}$크롬${\lrcorner}$${\ulcorner}$니켈${\lrcorner}$등의 도금(鍍金)을 하는 도금공(鍍金工)에 대하여 그 직업성질환(職業性疾患)을 관찰(觀察)하고 저 1976년(年) 6(월)月 대구시내(大邱市內) 소재(所在)하는 서로 유사한 종류와 방법으로 작업하고 있는 중소기업체(中小企業體) 중 작업환경개선(作業環境改善)이 어느 정도 되어 있는 곳과 전연 되어있지 않는 곳을 각각 1개소(個所)씩 선택(選擇)하며 비교해 본 결과 다음과 같이 요약(要約)할 수 있었다. 전반적(全般的)으로 비강내(鼻腔內) 증상(症狀)이 총출현빈도(總出現頻度) 중 50%이상을 점하며 다음 현기증(眩氣症)이 문제(文題)로 되어 있으며 환경개선(環境改善)을 함에 따라 비강내증세(鼻腔內症勢)중에서 괴양성 병변(病變)을 줄이어 증상(症狀)은 가볍게 되었으나 개입보호구사용(個入保護具使用)을 소홀히 함으로써 점차 만성적인 변화(變化)를 초래할 염려가 있었다. 각종 혈액상(血液相)중 ${\ulcorner}$헤모글로번${\lrcorner}$, ${\ulcorner}$헤마토크리트${\lrcorner}$ 적혈구(赤血球)와 요소견(尿所見)중 단백질당(蛋白質糖), ${\ulcorner}$우로비리노겐${\lrcorner}$등에는 큰 영향을 미치지 않고 있다고 생각된다.

  • PDF

The Effect of Platform Screen Doors on PM10 Levels in a Subway Station and a Trial to Reduce PM10 in Tunnels

  • Son, Youn-Suk;Salama, Amgad;Jeong, Hye-Seon;Kim, Suhyang;Jeong, Jin-Ho;Lee, Jaihyo;SunWoo, Young;Kim, Jo-Chun
    • Asian Journal of Atmospheric Environment
    • /
    • 제7권1호
    • /
    • pp.38-47
    • /
    • 2013
  • $PM_{10}$ concentrations were measured at four monitoring sites at the Daechaung station of the Seoul subway. The four locations included two tunnels, a platform, and a waiting room. The outside site of the subway was also monitored for comparison purposes. In addition, the effect of the platform screen doors (PSDs) recently installed to isolate the $PM_{10}$ in a platform from a tunnel were evaluated, and a comparison between $PM_{10}$ levels during rush and non-rush hours was performed. It was observed that $PM_{10}$ levels in the tunnels were generally higher than those in the other locations. This might be associated with the generation of $PM_{10}$ within the tunnel due to the train braking and wear of the subway lines with the motion of the trains, which promotes the mixing and suspension of particulate matter. During this tunnel study, it was observed that the particle size of $PM_{10}$ ranged from 1.8 to 5.6 ${\mu}m$. It was revealed that the $PM_{10}$ levels in the tunnels were significantly increased by the PSDs, while those in the platform and waiting room decreased. As a result, in order to estimate the effect of ventilation system on $PM_{10}$ levels in the tunnels, fans with inverters were operated. It was found that the concentration of $PM_{10}$ was below 150 ${\mu}g/m^3$ when the air flow rate into a tunnel was approximately 210,000-216,000 CMH.

포스트 코로나 시대의 대학교 주변 원룸형 주택에 대한 실내 공기질 분석 및 위해성 평가 (An Analysis of Indoor Air Quality and Risk Assessment for One-room Housing around the University in the Post-Corona Era)

  • 포위;정재연;정인수
    • 한국농촌건축학회논문집
    • /
    • 제24권3호
    • /
    • pp.23-30
    • /
    • 2022
  • In this study, in order to grasp the current situation of indoor environmental pollution and indoor ventilation in one-room around the university in the post-corona era, we analyzed the experimental data and conducted a questionnaire survey on university students. By analyzing the content, the effects of formaldehyde, dust and other pollution on the human body, which are usually not easily detectable, are digitized and more easily taken into account. Among the experimental results, the concentration of VOC and HCHO, gas pollutants among indoor pollutants, exceeded the recommended criteria of the Ministry of Environment in most studio apartments. Overall, the average CO2 concentration was lower than the Ministry of Environment's maintenance standard (1000ppm), but it was relatively high in summer and winter, and it is believed to be caused by cooling and heating in an enclosed space. The levels of PM2.5 and PM10, particulate pollutants, increased in November and December, and it is believed that ventilation defects due to degradation in external temperature. There was no clear difference between the two types, and there was a very high correlation between PM2.5 and PM10, HCHO and VOC. It was found that temperature was closely correlated with all sources except CO2, and humidity was closely correlated with all sources except PM2.5 and PM10. Health risk assessment was conducted for formaldehyde. The average ECR of studio R2 in May was 3.91E-4, and the ECR figure in September was 3.65E-4, which was very high compared to other residential spaces. The R2 level was calculated as 4 people per 10,000 people in the lifetime risk of cancer of residents, exceeding the allowable risk. R8 also showed higher ECR results than other spaces after R2, especially in October, 2.01E-4, six times higher than R7 measured in October, and 1.87E-4 in July, four times higher than R9.

煖房器具를 사용하는 室內空氣중의 벤조(a) 피렌 成分濃度에 관한 硏究 (Benzo(a) pyrene Level in Indoor Environment due to the Use of Unvented Heating Facilities)

  • 董宗仁
    • 한국대기환경학회지
    • /
    • 제3권1호
    • /
    • pp.65-73
    • /
    • 1987
  • Indoor air pollution problems, in fact, have been neglected due to the unawareness of its seriousness and the lack of accumulated data. Recently, some movement of research and regulations, however, have been made for several indoor air pollutants. In this study, one of the carcinogenic polynuclear aromatic hyrocarbon, Benzo(a) pyrene in indoor airborne particulate, was measured and analyzed to estimate emission strength of BaP from an unvented kerosene heater and to know its level in indoor environment with use of a kerosene heater and a wood-burning fireplace. By the measurement of BaP level in a dark room with air exchange rate of app. 3.0, BaP emission strength of a kerosene heater (11,000Btu/hr) was estimated to be 326.6ng/hr (or 29.7 ng/$10^3$ Btu). With 4-hr operation a day of the kerosene heater in an apartment, the BaP level became 2.97ng/m$^3$ from 0.27ng/m$^3$ of background level. The operation of a wood-burning fireplace app. 2hr a day, on the other hand, increased the BaP level from 0.16ng/m$^3$ of background to 3.53ng/m$^3$. So proper ventilation must be considered seriously when unvented heating facilities are used in indoor environment.

  • PDF

에너지 절감용 조명 및 공조기기 최적제어 시스템 개발 (Development of Optimal Control System for Lighting and HVAC(Heating, Ventilation, Air Conditioning) Using Energy Saving)

  • 장우성;송영석;조병록;조석환
    • 한국전자통신학회논문지
    • /
    • 제13권5호
    • /
    • pp.1029-1036
    • /
    • 2018
  • 본 논문은 캠퍼스환경에서 에너지 절약을 위해 조명 및 공조기기의 최적제어 시스템 개발에 대한 연구이다. 본 연구를 통해 개발 된 제어 시스템의 경우 모션센서와 영상처리를 통해 출입 인원수 파악과 온/습도에 대한 정보로 조명과 에어컨을 제어한다. 또한 데이터 통합 모니터링과 제어 신호에 따른 명령 수행 기능을 통해 제어한 결과들로 에너지 절약을 가능하도록 하였다.

스크린도어가 설치된 대심도 지하역사의 제연 실험 I - 승강장에서의 제연의 효과 분석 (Smoke Control Experiment of a Very Deep Underground Station Where Platform Screen Doors are Installed (I) - Analysis on Smoke Control Performance on the Platform)

  • 박원희;김창용;조영민;권태순;이덕희
    • 예술인문사회 융합 멀티미디어 논문지
    • /
    • 제8권7호
    • /
    • pp.485-496
    • /
    • 2018
  • 본 논문에서는 스크린도어가 설치되어 있는 지하역사 승강장에서 화재가 발생시 승강장 환기실에 설치된 송풍기의 작동에 따른 연기거동을 실험적인 방법으로 측정하였다. 스크린도어가 닫힌 승강장에서 모의화재 발생시 승강장의 제연설비가 작동하지 않은 경우와 작동하는 경우에 제연 특성을 비교하였다. 화재연기를 모사하기 위하여 연기발생기에서 발생한 연기를 열풍기를 이용하여 가열하였다. 화재연기를 정량적으로 측정하기 위하여 연기농도계를 이용한 광투과도를 측정하였다. 스크린도어가 닫혀져있고 지하역사의 제연설비가 작동되지 않는 경우 승강장에 화재가 발생하면 연기가 승강장 내부에 축적되어 승객의 피난이 매우 어려우며, 매우 위험한 상황으로 연결될 수 있음을 확인할 수 있었다. 반면에 역사의 제연설비를 가동한 조건에서는 승강장 화재에 의해 발생한 연기가 역사의 제연설비를 통하여 외부로 빠져나가며, 대합실에서 승강장 방향으로 기류가 형성되어 승강장 승객이 대합실 방향으로 대피하는 것이 가능함을 확인할 수 있었다. 후속 논문에서는 승강장 인접부에 위치한 터널환기구를 통한 터널 제연의 병행효과에 대하여 다룰 예정이다.

전동차내 부유 미생물 저감방안에 관한 연구 (A Research to Decrease Airborne Microoganism the Train)

  • 최성호;최순기;손영진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.2895-2901
    • /
    • 2011
  • 서울메트로 지하철 1~4호선 이용객은 하루 평균 450만명이 지하철을 이용(2010년 상반기 수송인원 현황)하고 있으며 이것은 서울시 인구 57%에(2009년도 서울시 인구 총1,046만명) 가까운 사람들이 지하철을 이용하고 있는 것으로 나타남에 따라 전동차에 쾌적한 실내공기질 유지 및 관리는 무엇보다 중요하다. 특히 전동차내 실내공기질에 영향을 미치는 요인으로는 승객의 재채기, 호흡과 같은 생체 활동 및 피부각질 등에 의한 부유 미생물 작용에 있다(권순박 등, 2011). 바이러스와 같은 미생물 오염 물질이 승객의 인체의 호흡기, 점막부위, 피부 등에 접촉 할 경우 과민성 질환, 아토피 피부염, 전염성 질환, 알레르기성 질환, 호흡기 질환을 유발할 수 있는(환경부-국립환경과학원, 생활속 세균 이렇게 관리하세요) 산업 보건상의 문제로 대두되고 있어 적절한 환기 시스템 도입과 제습을 위한 냉방 등이 필요한 실정이다. 시민들의 관심과 보조를 맞추어 지하철 2호선 출 퇴근 및 평상시 전동차 객실내 부유 미생물을 측정한 결과 부유세균과 부유진균은 2011년도 85~385$cfu/m^3$, 67~98$cfu/m^3$로 기준치(별도의 법적 기준은 없으나, 부유세균은 국내 실내기준 800$cfu/m^3$, 부유진균은 세계보건기구의 가이드라인 150$cfu/m^3$) 보다 낮은 수준으로 나타났으나 유동인구가 많은 출 퇴근 시간대에는 미생물 오염 물질이 승객에게 쉽게 전염 될 가능성이 있을 것으로 사료됨에 따라 부유 미생물 오염방지를 위한 공기조화설비 성능개선 등 실질적인 개선방안을 찾는 것이 필요하다. 이에 본 연구에서는 2004년 이후 부유 미생물 제어장치에 대한 연구 논문을 분석하여 부유미생물이 승객들에게 미치는 영향, 환기량 증대방안 등의 다양한 인자에 대한 분석을 통하여 전동차내 공기질을 실질적으로 개선할 수 있는 방법을 연구 하였다.

  • PDF

라돈농도 측정을 위한 고체비적검출기의 상대교정법 개발 및 응용 (Development of Relative Calibration Method for Measurement of Radon and Application)

  • 박영웅;양현수
    • Journal of Radiation Protection and Research
    • /
    • 제22권4호
    • /
    • pp.243-250
    • /
    • 1997
  • 공기 중의 라돈 농도를 측정하기 위한 고체비적검출기의 상대교정법을 개발하였으며, 상대 교정된 CN-85를 이용하여 15층 아파트 층 별로 실내 공기 중의 라돈 농도를 측정한 후 피폭 선량을 계산하여 보았다. 측정 결과 아파트 실내 공기 중에서의 라돈 농도는 대체적으로 상층으로 올라갈수록 감소하는 경향이 있었으나, 환기 횟수에 크게 영향을 받음을 알 수 있었다. 측정값의 평균은 $1.50{\pm}0.51pCi/1$ 였으며, 최대값과 최소값은 각각 $2.68{\pm}0.32pCi/l$, $0.69{\pm}0.16pCi/l$였다.

  • PDF