• Title/Summary/Keyword: Room

Search Result 15,293, Processing Time 0.041 seconds

Analysis on ventilation efficiency by CFD simulation for breathing zone in bed room (CFD해석에 의한 침실 호흡역의 환기효율 분석)

  • Yoo, Bok-Hee;Yoon, Chung-Sook
    • KIEAE Journal
    • /
    • v.2 no.3
    • /
    • pp.11-16
    • /
    • 2002
  • Indoor air environment is one of the most important factors that affect resident's health and comfort level. In this paper, the influence of ventilation efficiency with different types of furniture arrangement at breathing zone in a room was analyzed by numerical simulation based on computational fluid dynamics(CFD). The furniture layout of students' bedroom have been classified by three different patterns so that SVE3(scale for ventilation efficiency3) in the rooms was analyzed for air flow distribution. According to the results of the study, SVE3 has the maximum value in spaces between furnitures and each comer of the room. The furniture arrangement influences the ventilation efficiency. It was con finned that ventilation effective in a room is not uniformly distributed as compared the breathing zone with all the area in a room. It means that a study of ventilation efficiency was considered relatively with target zone(a residential or breathing zone) and all the area in a space.

Heat and Flow Analysis on Cabin Room of Battle Tank (전차 포탑 승무원실의 내부 열/유동장에 관한 수치적 연구)

  • NamKoung, H.J.;Lee, K.H.;Park, B.H.;Roh, K.L.
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.5-10
    • /
    • 2006
  • The heavy thermal load to battle tanks can cause electronic components' malfunction and crew to be put out of action. The thermal load is generated from Internal heat sources such as electronic devices installed in the room as well as extremely hot weather. In this study, heat and flow analysis for the cabin room of a battle tank was performed to deal with this thermal problem. This study presented the validation of simulation results in comparison with those of test, the investigation of optimal flow design for effective cooling in cabin room and finally the evaluation of thermal comforts to crew.

An Experimental Study on the Acoustic Characteristic of Korean Traditional Houses in Chonnam Province (전남 지방 전통주택의 음향특성에 관한 실험적 연구)

  • Lee, Tai-Gang;Kim, Hyung-Ryul;Kim, Hang;Choi, Eun-Suk;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.686-689
    • /
    • 2005
  • This study aims to analyzed the acoustics characteristics of Korean Traditional Houses in Chonnam Province varied with lay out and floor plane to reflect the way of control for environmental condition. These houses are surveyed the reverberation time and level difference between rooms of the main living room and other main floored room, master room and kitchen. As a result, the reverberation time of traditional rooms are below 0.6 second, and the sound insulation performance of Korean traditional door are mostly very low grade with D-15. The level difference between rooms are low grade not to meet minimum class except between main living room and master room away from main living building.

  • PDF

Effectiveness of Ventilation Control in a Dry Room with a Heat and Moisture Source

  • Lee, Kwan-Soo;Lim, Kwang-Ok;Ahn, Kang-Ho;Jung, Young-Sick
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.4
    • /
    • pp.1-9
    • /
    • 2001
  • The temperature and moisture distributions in a dry room with a heat and moisture source -i.e., workers- are studied numerically by using a standard $k-\varepsilon$ turbulence model. In order to evaluate the effectiveness of heat and moisture ventilation inside the room, the heat removal capacity and the moisture exhaust efficiency are introduced. The effectiveness of ventilation control is analyzed by evaluating the temperature and humidity distributions in the room quantitatively. It is found that the mean absolute humidity inside the room is almost constant regardless of the models and the heat generation rates in this study range. This results from the fact that the moisture generation by the workers was relatively small. Through the modification of the design, 40% improvement in critical decay time was achieved.

  • PDF

Recent R&D Trend in Magnetic Refrigeration at Room Temperature (실온 자기냉동의 최근 연구개발 동향)

  • Lee, Jong-Suk
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.613-618
    • /
    • 2006
  • The 1st International Conference on Magnetic Refrigeration at Room Temperature was held at Montreux, Switzerland during September 27-30, 2005. The conference was the first of its kind to bring together about 140 scientists and engineers interested in magnetic refrigeration in one place. The magnetocaloric effect was discovered in 1881, however, magnetic refrigeration at room temperature was demonstrated to be viable in 1997 Since then, R&D efforts toward magnetic refrigeration have been on the rise around the world, in both areas of systems and materials. The conference reflected the recent R&D trend in magnetic refrigeration at room temperature, which includes the use of permanent magnet instead of superconductor magnet, switch from reciprocating to rotary magnetic refrigeration system, development of magnetic materials based on transition metal elements besides rare earth materials such as gadolinium(Gd).

  • PDF

Factors Influencing Length of Stay at the Recovery Room among Elderly Patients Undergone General Anesthesia (노인 수술 환자의 회복실 체류시간에 영향을 미치는 요인)

  • Kim, Sun-Mi;So, Hee-Young;Lee, Mi-Hyang;Park, Myou-Yun;Kwon, Myoung-Jin
    • Korean Journal of Adult Nursing
    • /
    • v.23 no.1
    • /
    • pp.87-99
    • /
    • 2011
  • Purpose: The study was designed to identify the factors that influence the length of stay of elderly people in the recovery room. Methods: The design of the study was descriptive correlation. The subjects were 196 general anesthesia patients. The data were analyzed by SPSS/WIN 17.0 program. Results: The average length of stay in the recovery room was 62.62 minutes. The length of stay in the recovery room was influenced by age (27.50%); number of diseases (12.97%) and albumin level (6.75%). Other related post operative factors (30.98%) were abnormal ABGA, shivering, PAR score, pain, arrhythmia, amount of bleeding, cardiovascular complication, hypertension and delirium. Those factors explained 78.2% out of the total variance of the length of stay. The strongest effector was the abnormal ABGA (${\beta}$=.226) and then shivering (${\beta}$=.222). Conclusion: The influencing factors should be assessed and monitored for the aged before and after surgery. Further research is needed to find the exact factors for ICU transfer elderly from recovery room and emergency surgery target.

A Survey on the Actual Wearing Condition of Clean Room Wears (Clean Room Wear의 착용실태에 관한연구)

  • 김경화
    • Journal of the Korean Society of Costume
    • /
    • v.48
    • /
    • pp.117-132
    • /
    • 1999
  • This study is focused on the questionaries regarding the physiological comfort and body fitness and freedom of movement for clean room smock and intended to present the basic information in designing more comfortable clean room wear through seizing the discomfort of wearet. The study is designed to survey and analyze the actual wearing condition and its problem applied to 400 workers assigned with two semiconductors manufacturing plants. The result of survey are as follows. 1. Clean room workers bras panties running shirts and 내찬 the as basic underwear since they absorb sweat protect their bodies and make them feel safe and comfortable throughtout the whole year. 2. With regard to body fitness most of the subject assessed it to be suitable but the girth of neck waist and hood is founded to be tight in many cases. 3. Most important selecting criteria of clean room smocks are adaptability of movement body fitness and carrying-ability. Most of repondents prefer side zipper and rib-knitted fabric as the fastening system. 4. As for freedom of movement it is disclosed that the subjects showed more or less of their complaints against its wearing easiness for parts of waist neck armpit and slacks adaptability and adaptability of movement.

  • PDF

The Evaluation of Fire Safety Performance on Interior Finish Materials (Gypsum Board, Plywood) (건물내장재(석고보드, 합판)의 화재성능평가)

  • 김충환;김종훈;김운형;하동명;이수경
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.55-62
    • /
    • 2001
  • The fire performance evaluation methods in Korea and overseas for interior finish materials were analysed and tested with gypsum board and Plywood by using room corner test not adopted by domestic code until now. The results of gypsum board (thickness:8 mm) and Plywood (thickness:4 mm) applying NFPA 265 and ISO 9705 test respectively are satisfied the assessment criteria. To assess a actual fire performance and classify fire hazard levels for interior finish materials, room-corner test and flame spread models should be adopted in building code and fire code to overcome limitations of current bench-scale test method.

  • PDF

A Study on the Experimental Sound Transmission Loss of Wall-Body in Song Practice Room (노래연습실 벽체의 투과손실에 관한 실험적 연구)

  • Yun, Jae-Hyun;Ju, Duck-Hoon;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.221-225
    • /
    • 2007
  • Recently, on account of stress relief and settlement of a healthy drinking culture, many people are visiting a song practice room. In case of such song practice room, since the mechanical voice through a loud accompaniment-music and microphone is on using, there has made a very loud noise, and it influences a lot to the adjacent other space and song practice room booth. Consequently, from the designing stage an efficient measures for soundproof and sound-insulation should be arranged. However, as most of the song practice room wall-bodies that already built up or under construction step were constructed merely with consideration on an interior-wise factor only, it is suffering at the soundproof and sound-insulation. Reflecting such viewpoint, this Study has measured Sound Transmission Loss on the subject for the song practice room wall-body recently built up, and based on the actually measured data, by practice of comparison?analysis on it using various evaluation methods, would intends to present a fundamental material for establishment an efficient sound-insulation measure.

  • PDF

A Study on the Acoustics Characteristics of a Music-room of School of Arts (예술학교 음악실의 음향성능 평가에 관한 연구)

  • Kook, Joung-Hun;Yun, Jae-Hyun;Jung, Chul-Woon;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.268-272
    • /
    • 2007
  • As Music Room in Art School is mainly for exercise of musical instrument rather than any lecture or music appreciation, it should be designed and constructed in consideration with Acoustic Condition on the preferential basis. However, in case of Music Room in Art School that has been built already or latest newly constructed, since it was designed and constructed without any reflection of Acoustic Characteristics, it appeared as inadequate for them to enjoy music appreciation or performance activity. On such view point, this Study has examined the physical Acoustic Characteristics for the subjects on those Music Rooms of Art Middle School, Art High School, Art College built in Cheonbuk Province, and it is deemed that the material grasped in such way could be utilized as the valuable data enables to improve Acoustic Performance at the time when designing and construction or renovation for Music Room hereafter.

  • PDF