• Title/Summary/Keyword: Roof types

Search Result 293, Processing Time 0.025 seconds

Change of the Moisture and Temperature in Planting Ground as Effected by Different Soil Thickness, Soil Mixture Ratios and Ground Cover Plants in the Green Roof System (옥상녹화에서 토심, 토양배합비 및 지피식물에 따른 식재지반 수분 및 온도변화)

  • Ju, Jin Hee;Yoon, Young Han
    • KIEAE Journal
    • /
    • v.10 no.3
    • /
    • pp.11-16
    • /
    • 2010
  • This paper has attempted to investigate the change in soil moisture volume and temperature of architecture by planting ground(soil thickness and soil mixture ratio) and ground cover plants(Sedum sarmentosum, Zoysia japonica, Chrysanthemum zawadskii) for middle region green roof system. For this, a test was conducted on the roof of Konkuk University building from April 2009 to October 2009. In terms of treatment, five types(SL, $P_7P_1L_2$, $P_6P_2L_2$, $P_5P_3L_2$, $P_4P_4L_2$) depending on soil mixture ratio and two types(15cm, 25cm) by soil depth were created. Results of soil moisture volume by soil mixture ratio in the 15cm soil thickness showed that the difference was significance between simple soil and mixture soil treatment, however, the statistical significance was not recognized according to soil mixture ratio. In case of 25cm soil thickness, soil moisture volume by soil mixture ratio was more higher 7Vol.%~10Vol.% in the mixture soil than simple soil treatment. In terms of districts planted ground cover plants, soil volume moisture differed among plants in the order Zoysia japonica 17.74 Vol.%$34.86^{\circ}C$, district non-planted $27.49^{\circ}C$, Sedum sarmentosum $25.11^{\circ}C$, Chrysanthemum zawadskii $23.08^{\circ}C$, Zoysia japonica $24.45^{\circ}C$ respectively So, concrete surface showed more higher $5^{\circ}C{\sim}15^{\circ}C$ than other things among the all the time. Result of inner temperature of the architecture and soil, it was measured inner of architecture $25.69^{\circ}C$, inner district non-planted $24.29^{\circ}C$, Chrysanthemum zawadskii $23.90^{\circ}C$, Zoysia japonica $24.02^{\circ}C$, Sedum sarmentosum $25.13^{\circ}C$, respectively.

A Study on the Acceptance of Western timber structure and the Interior space of Church buildings in the early modern period in Korea - Focused on the roof structure of church architecture in the Flowering and Japanese occupation period - (한국 근대초기 서양 목구조의 수용과 교회 내부공간형태에 관한 연구 - 개화기와 일제강점기 교회건축의 지붕틀 구조를 중심으로 -)

  • Kim Jung-Shin
    • Korean Institute of Interior Design Journal
    • /
    • v.14 no.5 s.52
    • /
    • pp.10-17
    • /
    • 2005
  • This Study is concerned with the acceptance of Western timber structure and the interior space of church buildings in the early modern period in Korea. Timber roofs have represented a wide variety of constructional forms and have been fundamental to any technological appraisal of the evolution of both of Western and Eastern architecture. Especially the roof structure of the church buildings reflects the technological level, aesthetic sense, and spacial concepts of the age. Between Western timber structure and Korean timber structure, there are many differences in not only structural form but also form of roof, members, load, frame system and etc. And there were various types of framing technique such as timber truss, timber arch, timber vault in the western style church architecture in the early modern period in Korea. I have summarized the character of the acceptance process of Western timber structure and the influences on the interior space of church buildings.

A Study on Quantitative Classification of Styles through Analysing Characteristics of Components in Green Roofs - Focused on the examples in Seoul - (옥상조경 구성 요소들의 특성을 분석한 정량적 유형구분 기준에 관한 연구 - 서울시 사례를 중심으로 -)

  • Gil, Sung-Ho;Song, Byeong-Hwa;Yang, Byoung-E
    • KIEAE Journal
    • /
    • v.11 no.1
    • /
    • pp.21-28
    • /
    • 2011
  • The objective of this study is to analysis the properties for reclassifying green roofs into three types by cluster analysis after investigating the present condition in thirty green roofs which were created from 2002 to 2004 by Seoul Metropolitan Government. The previous classification was resulted in structure safety diagnosis in the type of green roofs and visible judgment by experts in sites. However, it should have been corrected. Therefore, it needed a reestablished concept and a reclassification in green roofs. The results of this study are as follows : the concept of a rooftop garden and a green roof is different from previous studies. The rooftop gardens named by intensive green roofs are closed to integrated management, whereas the green roofs are closed to low management. The reclassification of green type was also conducted to use the statistic analysis of categorical regression by previous studies, and the factors extracted by the categorical regression were influenced by greening type. The figure of R-square representing explanation in regression analysis is 95.2%. As this result was analyzed, it was proved into rooftop gardens demanded for high activity by people.

Fatigue performance of rib-roof weld in steel bridge decks with corner braces

  • Fu, Zhongqiu;Ji, Bohai;Wang, Yixun;Xu, Jie
    • Steel and Composite Structures
    • /
    • v.26 no.1
    • /
    • pp.103-113
    • /
    • 2018
  • To study the effects of corner braces on fatigue performance of the U-rib and roof weld in steel bridge decks, the fatigue experiment was carried out to compare characteristics of the crack shape with and without corner braces. The improvement of fatigue life and stress variation after setting corner braces were also analysed. Different parameters of corner brace sizes, arrangements, and detail types were considered in the FEM models to obtain stress distribution and variation at the weld. Furthermore, enhancement of the fatigue performance by corner braces was evaluated. The results demonstrated that the corner brace could improve the fatigue life of the U-rib and roof weld, which exerted even no influence on the crack shape. Moreover, stress of the roof weld was decreased and the crack position was transferred from the root weld to U-rib and corner brace weld. It was suggested no weld scallop should be drilled on the corner brace. A transverse rib with lower height which was set between U-ribs was favourable for improvement of fatigue performance.

Seismic Design of Long Span Structures Based on Hysteric Energy Absorption Mechanism(1) (이력에너지흡수 원리를 이용한 대경간 구조물의 내진설계(1) -이선형 탄소성 이력거동에 의안 에너지 소산원리를 이용하는 방법-)

  • Cheong, Myung-Chae;Won, Sung-Dae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.1
    • /
    • pp.85-93
    • /
    • 2010
  • This paper suggests a vibration control method long span structures with trussed roof. Basic concept of this method is based on the energy absorption through hysteresis loop of an elasto-plastic element. This element is attached on the top of the column supporting the roof. Two different types of roofs and three of earthquake waves are used in the investigation. It shows that this is very efficient method to reduce the seismic energy of roof member transferred from the column.

  • PDF

The Types of the Rural Housing in the Sea Islands of Gyeongnam with Special Reference to the Roofing Types and Materials (경남 도서지역 촌락의 가옥 유형에 관한 연구 - 지붕 형태와 지붕 재료를 중심으로 -)

  • Lee, Jeon;Seong, Hwa Ryong
    • Journal of the Korean association of regional geographers
    • /
    • v.21 no.4
    • /
    • pp.660-672
    • /
    • 2015
  • The rural housing is a key element of the rural landscape. The studies on the rural housing have focused on folk housing, but this study focuses on the comtemporary rural housing. The research area is the eight rural settlements on the sea islands of Gyeongnam. This study may provide the base for an understanding Korean rural landscape through the analysis of the rural housing types with special reference to the roofing types and materials. Most roofing types but the flat roofing type belong to the traditional roofing types. Among the combined-style roofing(결합양식지붕) types, the pitched-and-flat roofing(경사-평지붕) type is about ten times more frequent than the pitched-and-pitched roofing(경사-경사지붕) type. The most frequent roofing materials are cement, precoated steel plate(컬러강판), and artificial slate(인조슬레이트). Five typical types of rural housing are derived from the remarkable combinations of roofing types and roofing materials in the research area.

  • PDF

A Study on the Structural and Other Influential Characteristics of Western Timber Roof Truss in Modern Buildings - Focusing the Record of Modern Buildings among the Cultural Assets maintained by Public Institution - (근대 건축물에 사용된 서양식 목조 지붕 트러스의 구조요인 및 기타 영향요인에 관한 연구 - 공공기관이 관리하는 문화재 중 근대건축물 기록을 중심으로 -)

  • Lee, Yoon-Hee;Yu, Hye-Ran;Kwon, Ki-Hyuk
    • Journal of architectural history
    • /
    • v.20 no.4
    • /
    • pp.95-114
    • /
    • 2011
  • Western style timber roof trusses used as typical roof structures of buildings during a modern period have been developed with the interactions with their facade and functionality. The shapes of trusses and member sizes have been diversely changed by the purposes of architects, historical circumstances, and structural characteristics. For this reason, the change in the shapes of western style timber trusses along the times is one of important technology assets demonstrating the development of their structures during the modern period. Therefore, the purpose of this paper is to find out their structural characteristics throughout parametric analysis of which parameters were determined from the collected and classified documents on western style timber roof structure built in the modern period carefully obtained from public institutions. Results of the parametric analysis are as follows. The number of king-post trusses and modified king-post trusses built between 1920 and 1937 reaches almost half of the total number of truss types investigated. The mean values of their spans, distances, tributary areas, and height are respectively, 10.5m, 2.4m, $24.37m^2$and 3.24m. The cross-section areas of trusses tend to reduce since the city construction law was enacted in 1920. Also, this study found that western architects usually used larger structural members than eastern architects and usages and finishing materials of roof trusses are not always considered as one of the important design parameters.

Generalized load cycles for dynamic wind uplift evaluation of rigid membrane roofing systems

  • Baskaran, A.;Murty, B.;Tanaka, H.
    • Wind and Structures
    • /
    • v.14 no.5
    • /
    • pp.383-411
    • /
    • 2011
  • Roof is an integral part of building envelope. It protects occupants from environmental forces such as wind, rain, snow and others. Among those environmental forces, wind is a major factor that can cause structural roof damages. Roof due to wind actions can exhibit either flexible or rigid system responses. At present, a dynamic test procedure available is CSA A123.21-04 for the wind uplift resistance evaluation of flexible membrane-roofing systems and there is no dynamic test procedure available in North America for wind uplift resistance evaluation of rigid membrane-roofing system. In order to incorporate rigid membrane-roofing systems into the CSA A123.21-04 testing procedure, this paper presents the development of a load cycle. For this process, the present study compared the wind performance of rigid systems with the flexible systems. Analysis of the pressure time histories data using probability distribution function and power spectral density verified that these two roofs types exhibit different system responses under wind forces. Rain flow counting method was applied on the wind tunnel time histories data. Calculated wind load cycles were compared with the existing load cycle of CSA A123.21-04. With the input from the roof manufacturers and roofing associations, the developed load cycles had been generalized and extended to evaluate the ultimate wind uplift resistance capacity of rigid roofs. This new knowledge is integrated into the new edition of CSA A123.21-10 so that the standard can be used to evaluate wind uplift resistance capacity of membrane roofing systems.

Effects of ventilation systems and set point temperature of single-span plastic greenhouse on disease incidence, fruit quality and yield of oriental melon (Cucumis melo L.) (참외재배 단동 비닐하우스의 환기방법과 설정온도가 병발병도,과실 수량 및 품질에 미치는 영향)

  • Yeo, Kyung-Hwan;Yu, In-Ho;Rhee, Han-Cheol;Choi, Gyeong-Lee;Lee, Seong-Chan;Lee, Jung-Sup
    • Korean Journal of Agricultural Science
    • /
    • v.42 no.4
    • /
    • pp.325-333
    • /
    • 2015
  • The ventilation systems composed three types of side vent (roll-up) 'SV', side vent+roof vent 'SV+RV', and side vent+roof fan 'SV+RF' with 7.5 m spacing, with specific set point temperatures for ventilation: SV ($35^{\circ}C$ open / $33^{\circ}C$ close), SV+RV or SV+RH ($35^{\circ}C$ open/$33^{\circ}C$ close for root ventilation and $37^{\circ}C$ open / $35^{\circ}C$ close for side vent). In the treatment of SV+RV, although the average daily maximum temperature inside the greenhouse temporarily increased by $38-40^{\circ}C$, thermal stress by high temperature did not occur and the disease incidence (%) of powdery mildew and downy mildew on the oriental melon were 25 - 75% lower than in the conventional SV treatment. In the SV treatment, the disease incidence (%) of powdery mildew and downy mildew were 1.4 - 7.7% and 4.2 - 15.9% for 'Deabakkul', and 20.3 - 22.8% and 2.8 - 11.3%, for 'Ildeungkkul'. The yield for one month was higher in the treatment of SV+RV than those in other treatments, with values of 2,105 kg/10a for 'Deabakkul' and 2,537 kg/10a for 'Ildeungkkul'. The simultaneous treatment with side vent and roof vent resulted in 16.2% higher yield (18.1% higher marketable yield) than that in the SV treatment for 'Deabakkul'.

A Study on the Analysis of Temperature Reduction Effect by the Types and Public Awareness of the Green Roof (옥상녹화의 녹화유형별 기온저감효과 및 시민의식 분석)

  • Lee, Chun-Woo;Kim, Soo-Bong;Moon, Hye-Shick;Jeon, Eun-Jeong
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.316-320
    • /
    • 2009
  • Recently, concerns about conserving proper size of urban green spaces and accessibility are increasing, regarding it as a solution to diverse urban environmental problems including pollution, ecosystem deterioration, urban climate change. Artificial ground greening such as green roofs is regarded as the only alternative that can conserve green spaces which are impossible to be secured on the ground. However, green roofs are not popularized yet and levels are very low in provincial cities despite of related technology development and support systems of related agencies. Based on the background, this study tries to present a theoretical basis of methods for green roofs, conducting green roof simulations and collecting ideas about problems and improving measures from green roof users. Finally, it aims to offer base data which help establish policy direction for activation of green roof technology. As a result of a simulation for verifying temperature reduction effect, it was possible to affirm effect of a plot that green roofs applied. Especially, it was revealed that a green roof method using ground covers such as mixed planting was the most effective way to reduce temperature. Activation methods for green roofs based on this study are as follows: First, it is a priority to readjust systems related to green roofs. Second, citizens' active and voluntary participation must be attained. Third, it is required to establish detailed promotion procedures which aim at actual conduct and to maintain an expert department which is able to manage and control the establishment. After conduct, continuous aftercare stages are also needed.

  • PDF