• Title/Summary/Keyword: Roof types

Search Result 293, Processing Time 0.026 seconds

3D Shape Descriptor for Segmenting Point Cloud Data

  • Park, So Young;Yoo, Eun Jin;Lee, Dong-Cheon;Lee, Yong Wook
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.6_2
    • /
    • pp.643-651
    • /
    • 2012
  • Object recognition belongs to high-level processing that is one of the difficult and challenging tasks in computer vision. Digital photogrammetry based on the computer vision paradigm has begun to emerge in the middle of 1980s. However, the ultimate goal of digital photogrammetry - intelligent and autonomous processing of surface reconstruction - is not achieved yet. Object recognition requires a robust shape description about objects. However, most of the shape descriptors aim to apply 2D space for image data. Therefore, such descriptors have to be extended to deal with 3D data such as LiDAR(Light Detection and Ranging) data obtained from ALS(Airborne Laser Scanner) system. This paper introduces extension of chain code to 3D object space with hierarchical approach for segmenting point cloud data. The experiment demonstrates effectiveness and robustness of the proposed method for shape description and point cloud data segmentation. Geometric characteristics of various roof types are well described that will be eventually base for the object modeling. Segmentation accuracy of the simulated data was evaluated by measuring coordinates of the corners on the segmented patch boundaries. The overall RMSE(Root Mean Square Error) is equivalent to the average distance between points, i.e., GSD(Ground Sampling Distance).

Practical second-order analysis and design of single angle trusses by an equivalent imperfection approach

  • Cho, S.H.;Chan, S.L.
    • Steel and Composite Structures
    • /
    • v.5 no.6
    • /
    • pp.443-458
    • /
    • 2005
  • Steel angles are widely used in roof trusses as web and chord members and in lattice towers. Very often angle members are connected eccentrically. As a result, not only an angle member is under an axial force, but it is also subject to a pair of end eccentric moments. Moreover, the connection at each end provides some fixity so neither pinned nor the fixed end represents the reality. Many national design codes allow for the effects due to eccentricities by modifying the slenderness ratio and reducing the compressive strength of the member. However, in practice, it is difficult to determine accurately the effective length. The concept behind this method is inconsistent with strength design of members of other cross-sectional types such as I or box sections of which the buckling strength is controlled by the Perry constant or the initial imperfection parameters. This paper proposes a method for design of angle frames and trusses by the second-order analysis. The equivalent initial imperfection-to-length ratios for equal and unequal angles to compensate the negligence of initial curvatures, load eccentricities and residual stresses are determined in this paper. From the obtained results, the values of imperfection-to-length ratios are suggested for design and analysis of angle steel trusses allowing for member buckling strength based on the Perry-Robertson formula.

A Study on the Preference of Facade Element for Hanok Multi-Family Housing in Old Naju City Areas (고향(古都) 나주에서의 한옥집합주거 모델의 형태요소 연구)

  • Kim, Byoung-Jin;Shon, Seung-Kwang
    • Journal of the Korean housing association
    • /
    • v.22 no.3
    • /
    • pp.135-144
    • /
    • 2011
  • This study has extracted elements and related factors in the modernization of Hanok, using an evaluation method, and has also considered the possibilities of modern images using AHP analysis. As a result, first, the elements that form the urban landscape of historical and cultural environment have to be created by extracting elements from the subject standard for construction of the elements selected. As for the aspect of blending history, culture and environment, scenic and important architectural aspects were delineated. Second, based on selected components of the basic type of features and construction, roof types, vertical and horizontal elements were simulated after setting the criteria. Third, according to its historical cultural circumstances the man-made landscape and the traditional measure of the model, specific values of the elements for the formation of structures were evaluated by priority. A region characterized by old city houses constructed of objective elements can possibly be combined. In addition, a Hanok multi-family house fitted for modern life and a variety of models to develop and validate the possibility and utilization of this study can be expected.

A Study on Manufacturing and Processes of the Lightweight Block Unit for Roof Greening with Bottom ash (옥상녹화용 경량유닛의 블록제조 공법 및 공정 연구)

  • Moon, Jong-Wook;Oh, Jung-Keun;Lee, Tae-Goo
    • KIEAE Journal
    • /
    • v.12 no.3
    • /
    • pp.95-100
    • /
    • 2012
  • Thermal phenomena has caused abnormal weather phenomena due to the lack of urban green spaces To solve these problems, the country of recorded a city business is actively evolving trends. but in all the land, most built-up city's green buildings unless the demolition of the composition is an impossible situation, green space in urban areas, with emphasis on composition. In this study, thermal power plants that occured in the evolution of vegetation by utilizing Bottom Ash was tried to develop a lightweight block. Bottom Ash block to take advantage of vegetation is focused create green space in urban areas Vegetation in the block was carried out manufacturing lightweight, porous, lightweight water ratio suitable for three types of blocks selected according to its kind study on the manufacturing and process. Bottom Ash from this study at the time of disposal of coal ash generated by recycling the landfill shortages, loss of landfill costs, environmental pollution and are trying to solve the same problem at the same time.

An Experimental Study of Performance Improvement of Air Type PV/T Collector Units (실험에 의한 공기식 태양광·열 복합 유닛의 성능 비교)

  • Kim, Jin-Hee;Yang, Yeon-Won;Kim, Jun-Tae
    • KIEAE Journal
    • /
    • v.7 no.6
    • /
    • pp.17-22
    • /
    • 2007
  • The integration of PV modules into building facades or roof could raise their temperature that results in the reduction of PV system's electrical power generation. Hot air can be extracted from the space between PV modules and building envelope, and used for heating in buildings. The extraction of hot air from the space will enhance the performance of BIPV systems. The solar collector utilizing these two aspects is called PV/T(photovoltaic/thermal) solar collector. This paper compares the experimental performance of two different types of air type PV/T collector units: the base case of a collector unit with 10cm gap for forced ventilation and the other unit with copper pin attached to PV module to enhance its thermal performance. The experimental results shows that the base case unit had the overall efficiency of 41.9% and the improved unit with copper pin attached to PV module had 50.1% efficiency. For these air type PV/T units, the forced ventilation of the air space improved the electrical performance as well as the thermal performance.

Rope Modeling and Verification for the Robotic Platform of the Wall Cleaning Robot (ROPE RIDE) (외벽청소로봇(ROPE RIDE)의 등강 로봇 플랫폼을 위한 로프 모델링 및 검증)

  • Yoo, Sungkeun;Kim, Taegyun;Seo, Myoungjae;Kim, Hwa Soo;Seo, TaeWon
    • The Journal of Korea Robotics Society
    • /
    • v.14 no.3
    • /
    • pp.191-195
    • /
    • 2019
  • This paper presents a rope modeling and verification for the robotic platform of the wall cleaning robot (ROPE RIDE). ROPE RIDE has the characteristics of climbing up and down using a rope fixed on the roof like traditional workers. In order to perform a stable operation with a wall cleaning robot, it is necessary to estimate the position of the robot in a vertical direction. However, due to the high coefficient of extension and nonlinearity of the climbing rope, it is difficult to predict the behavior of the rope. Thus, in this paper, the mathematical modeling of the rope was carried out through the preliminary experiment. Extensive experiments using different types of rope were used to determine the parameters of the constitutive equation of climbing ropes. The validity of the determined parameters of various ropes was verified through the experiment results.

Evaluation of a new proposed seismic isolator for low rise masonry structures

  • Kakolvand, Habibollah;Ghazi, Mohammad;Mehrparvar, Behnam;Parvizi, Soroush
    • Structural Engineering and Mechanics
    • /
    • v.77 no.4
    • /
    • pp.481-493
    • /
    • 2021
  • Low rise masonry structures are relatively inexpensive and easier to construct compared to other types of structures such as steel and reinforced concrete buildings. However, masonry structures are relatively heavier and less ductile and more vulnerable to damages in earthquakes. In this research, a new innovative low-cost seismic isolator using steel rings (SISR) is employed to reduce the seismic vulnerability of masonry structures. FEA of a masonry structure, made of concrete blocks is used to evaluate the effect of the proposed SISR on the seismic response of the structure. Two systems, fixed base and isolated from the base with the proposed SISRs, are considered. Micro-element approach and ABAQUS software are used for structural modeling. The nonlinear structural parameters of the SISRs, extracted from a recent experimental study by the authors, are used in numerical modeling. The masonry structure is studied in two separate modes, fixed base and isolated base with the proposed SISRs, under Erzincan and Imperial Valley-06 earthquakes. The accelerated response at the roof level, as well as the deformation in the masonry walls, are the parameters to assess the effect of the proposed SISRs. The results show a highly improved performance of the masonry structure with the SISRs.

Vertical uplift of suspension equipment due to hanger slackening: Experimental and numerical investigation

  • Yang, Zhenyu;He, Chang;Mosalam, Khalid M.;Xie, Qiang
    • Structural Engineering and Mechanics
    • /
    • v.82 no.6
    • /
    • pp.735-745
    • /
    • 2022
  • The suspension thyristor valve can generate tremendous vertical acceleration responses in layers and large tension forces in hangers. A shaking table test of a scaled-down model of thyristor valves suspended on a hall building is performed to qualify the risk of vertical uplift of two representative types of valves, the chain valve and the rigid valve. Besides, an analytical model is established to investigate the source of the slackening of hangers. The test results show that the valves frequently experience a large vertical acceleration response. The soft spring joint can significantly reduce acceleration, but is still unable to prevent vertical uplift of the chain valve. The analytical model shows a stiffer roof and inter-story connection both contribute to a higher risk of vertical uplift for a rigid valve. In addition, the planar eccentricity and short hangers, which result in torsional motion of the valve, increase the possibility of vertical uplift for a chain valve. Therefore, spring joints with additional viscous dampers and symmetric layout in each layer are recommended for the rigid and chain valve, respectively, to prevent the uplift of valves.

A Study on Energy Requirement Variation According to Energy Efficiency Rating Evaluation and Design Variable of Standard Design of Rural Houses (농촌주택표준설계도 에너지효율등급평가 및 설계변수에 따른 에너지소요량 변화에 관한 연구)

  • Park, Mi-Lan;Ryoo, Yeon-Su;Choi, Jeong-Man;Seo, Hye-Won
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.19 no.2
    • /
    • pp.9-16
    • /
    • 2017
  • The study analyzed the heat losses and the building energy efficiency grade by the energy simulation using the ENERGY# and ECO2 programs for the three types of Standard design of rural houses. It was calculated the energy efficiency rating by the ECO2 program for the rural housing standard design, and the energy demand and the energy consumption by each factor were compared and analyzed. And it analyzed energy consumption by element of each house by ENERGY # program. As a result, first in the evaluation of the energy efficiency grade of buildings by the ECO2 program, the rating for primary energy requirement for the housing newly built by the standard design of rural house is expected to range from 2 to 4 with 189.3 to $238.7kWh/m^2.a$. Second, the energy loss of each part of standard design of rural housing occurs in the order of ventilation 39%, window 33%, outer wall 14%, roof 9%, bottom 5%, and energy loss through ventilation and window occurs more than 70%. Third, the most beneficial effects on the energy efficiency grade is obtained the lowest grade of all three types by 2 when the lowering of the window and door heat transmission rate and the lowering of the light density, and the heat exchange ventilation device is not installed. Fourth, in the standard design of rural housing, the energy demand is occupied by heating > hot water > lighting order, and the order of the weight is changed in order of heating > lighting > ventilation > hot water. Fifth, building energy efficiency assessment system needs to establish policy for fixing rural housing energy as a practical device to ensure energy performance and quality.

Characterization of Runoff Properties of Non-point Pollutant at a Small Rural Area considering Landuse Types (토지이용 특성을 고려한 소규모 농촌유역의 비점오염물질 유출특성 해석)

  • Bae, Sang-ho;Kim, Weon-jae;Yoon, Young H.;Lim, Hyun-man;Kim, Eun-ju;Park, Jae-roh
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.4
    • /
    • pp.654-663
    • /
    • 2010
  • Attention has increasingly focused on the pollutant load discharged from rural area since the enforcement of total maximum daily loads (TMDLs) in korea. As one of the methods to control the inflow of pollutant load during wet weather events, local governments are attempting to apply non-point source control facility. To design those facilities appropriately, it is essential to understand the runoff characteristics of pollutants such as TSS, $BOD_5$, $COD_{Cr}$, TP and TN. In the paper, the quantitative analyses for pollutant runoff characteristics were examined in a small rural watershed with the area of about 53 hectares. For a dry weather day and wet weather events, variation patterns of dry weather flow and runoff characteristics of wet weather flows were monitored and investigated. The runoff model using XP-SWMM reflecting the landuse types of the watershed in detail was simulated to perform the sensitivity analyses for several factors influencing on their hydrograph and pollutographs. As a result, for the case of medium and small rainfall events (i. e. total rainfall of 35.8 and 17.5 mm), the impervious area including green house, roof and road which covers relatively low portion of total area (i. e. 16%) caused substantial first flush and the majority of total runoff load. Therefore, it has been concluded that the runoff characteristics of each pollutant and distribution of impervious area should be considered for the establishment of the control strategy of non-point pollutant runoff at a rural area.