• Title/Summary/Keyword: Rod

Search Result 3,439, Processing Time 0.045 seconds

ACL reconstruction with autologous hamstring tendon - Short term clinical result using new femoral suspensory fixation device 'Cross Pin' and graft tensioner for maintaining a constant tension- (자가 슬괵건을 이용한 전방 십자 인대 재건술 - 새로운 대퇴부 현수고정법인 Cross Pin과 일정한 긴장력 유지를 위한 Graft Tensioner 사용의 단기 추시 결과 -)

  • Seo, Seung-Suk;Kim, Chang-Wan;Kim, Jin-Seok;Choi, Sang-Yeong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.1
    • /
    • pp.27-34
    • /
    • 2011
  • Purpose: To evaluate the short term clinical result of ACL reconstruction with autologous hamstring tendon using Cross pin and Graft Tensioner and to seek way to resolve the experienced technical problems. Materials and Methods: From January 2008 to March 2009, 35 patients who had been treated arthroscopic ACL reconstruction were enrolled. The femoral side of ACL graft was fixed with Cross pin. The tibial side of graft was fixed with Intrafix and post-tie. The graft was tensioned with Graft Tensioner at 80N. We analyzed the clinical, radiographic results and complications. Results: IKDC subjective score and Lysholm score improved to 89.1 and 91.4 points. Also, Pivot shift test and One-leg hop test showed good results postoperatively. Side to side difference using KT-1000 arthrometer and Telos stress radiography improved compared with normal limb to $2.8{\pm}1.6$ mm and $2.6{\pm}1.3$ mm, respectively. The femoral tunnel enlarged to $2.3{\pm}1.1$ mm. Soft tissue irritation and femoral tunnel-graft harness length mismatch, femoral tunnel-cross pin tunnel mismatch were happened as peri-operative complications. Conclusion: Using of Cross pin and Graft Tensioner for ACL reconstruction with hamstring tendon is one of the good method for obtaining stability in short-term clinical result. But to reduce femoral tunnel-cross pin mismatch, it needs to shorten femoral bone tunnel and to create cross pin tunnel as vertical as possible. And to reduce femoral tunnel-graft harness mismatch, it needs to advance position rod further 3 mm when to create femoral tunnel.

  • PDF

Growth Patterns of Lactic Acid Bacteria during Fermentation of Radish with Rice Water and Rice Bran (쌀뜨물과 쌀겨를 이용한 무 발효과정 중 젖산균의 증식 양상)

  • Cho, Joon-Il;Jung, Hye-Jin;Ha, Sang-Do;Kim, Keun-Sung
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.5
    • /
    • pp.837-841
    • /
    • 2004
  • Changes in total aerobic bacteria (TAB), lactic acid bacteria (LAB), rod- and coccal-shaped lactic acid bacteria (R- and C-LAB), pH, and total acidity were investigated during fermentation of radish with new fermentation base at $20^{\circ}C$ for up to 16 days. New fermentation base was prepared by pre-fermenting a mixture of rice bran and rice water (1 : 0.1, w/v) at $20^{\circ}C$ for 7 days. Initially, radish showed 5.41, 4.23, 4.57, and 3.1 log CFU/g, and base showed 6.68, 6.60, 5.95, and 5.6 log CFU/mL for TAB, LAB, R-LAB, and C-LAB, respectively. Initial pH and total acidity of radish were $6.6^{\circ}C$ and 0.09%, and those of base were 5.76 and 0.36%, respectively, Counts of LAB (4.23 to 8.33 Bog Cpu/g, 6.6 to 9.7 log CFU/mL), R-LAB (4.57 to 7.15 log CFU/g, 5.95 to 8.5 log CFU/mL), and C-LAB (3.1 to 7.5 log CFU/g, 5.6 to 8.6 log CFU/mL) of radish and base respectively increased during initial fermentation period, then remained constant during late fermentation period, and far 4 days after fermentation, pH values (6.6 to 4.19, 5.76 to 4.57) drastically decreased and thereafter slowly decreased. Total acidities of radish and base (0.09 to 0.63%, 0.36 to 0.63%, respectively) drastically increased far 7 days after fermentation and increased slightly thereafter.

Submicroscopy of Forest Soils (kandiustults) Derived from Granite in Southern Part of Korea (우리나라 남부지역(南部地域) 화강암질(花崗巖質) 삼림토양(森林土壤)의 SEM과 TEM에 의한 관찰(觀察))

  • Cho, Hi Doo;An, Ki Wan
    • Journal of Korean Society of Forest Science
    • /
    • v.90 no.5
    • /
    • pp.608-618
    • /
    • 2001
  • To understand the weathering processes of the soil by submicroscopic method is very important to realize the properties of the soils. In this study soil formation processes show every steps to the changes in chemical and mechanical properties and the submicroscopic characteristics of soil weathering on the profiles of forest soils derived from granite in southern part of Korea. Fecal pellets(SEM) are given a full detail of the positive activities of the forest soil animals; mainly invertebrates in the O horizon and the E horizon. External shapes of fecal pellets have been divided into five groups : spherical, ellipsoidal, cylindrical, platy and threadlike. But doughnutlike form of fecal pellets is observed in this study. The soluble and suspended materials in the soils move downwards by percolation from the A horizon to the B or the BC horizons, and result in the illuviation cutans(SEM) on the ped surface of the lower horizon and deposited stack of kaolinite. Illuviated cutans are deposited on the ped surface even in the depth of 312cm in the BC horizon as well as the Bt horizon and comprise of fine silt, coarse clay and fine clay. A lot of halloysites are observed on the cutan surface. Halloysite formation from feldspars has been well known but a lot of hallyosite formation are observed in this study. The formation were predicted by Jackson(1962), inferred by Wada and Kakuto(1983a, b) and proved evidently by Cho and Mermut(1992a, b). This also suggests that halloysites in the soils derived from granite are formed a lot from ferruginous chlorites. The release of Fe from the chlorite structure are significant pedogenic processes and newly formed Fe oxides imparted a red color to the soils. The iron oxides particles, which are ejected and recrystalized, aggregate thickly on the edge of the ferruginous chlorites, and this indicates the release of structural Fe from weathered chlorites. Hematites and goethites are frequent in the fine clay in this soils.

  • PDF

Impact Resistance Reliability of Sn-1.2Ag-0.5Cu-0.4In Solder Joints (Sn-1.2Ag-0.5Cu-0.4In 조성 솔더 접합부의 내 충격 신뢰성 평가)

  • Yu, A-Mi;Lee, Chang-Woo;Kim, Jeong-Han;Kim, Mok-Soon;Lee, Jong-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.226-226
    • /
    • 2008
  • 지난 10여년 동안 Sn-3.0Ag-0.5(wt%)Cu 합금은 대표 무연솔더 조성으로 다양한 전자제품의 실장 및 접합에 적용되어 왔으며, 그 신뢰성 역시 충분히 검증된 바 있다. 그러나 최근 Ag 가격의 급격한 상승과 솔더 접합부의 내 충격 신뢰성을 보다 향상시키고자 하는 업계의 동향은 Ag의 함량이 낮은 무연솔더 조성의 적용 확대를 유도하고 있다. 이에 따라 본 연구자들은 저 Ag 함유 무연슬더로 Sn-1.2Ag-0.5Cu-0.4In 조성을 제안한 바 있는데, 이는 Sn-3.0Ag-0.5Cu 조성 이상의 solderability를 가지면서도 그 금속원료 가격이 약 20% 가량 저렴한 특징을 가진다. 또한 열 싸이클링 (cycling) 테스트를 통한 슬더 조인트의 신뢰성을 평가한 결과, Sn-3.0Ag-0.5Cu에 크게 뒤떨어지지 않는 양호한 특성이 관찰되었다. 따라서 본 연구에서는 열 싸이클링 테스트와 더불어 최근 그 중요성이 지속적으로 커지고 있는 내 충격 신뢰성 평가 시험을 실시하여 개발된 4원계 무연솔더 조성의 기계적 특성을 기존 무연솔더 조성과 비교, 분석해 보았다. 각 솔더 조성은 솔더 볼 형태로 제조되어 CSP(Chip Scale Package) 상에 범핑 (bumping)되었으며, CSP를 PCB(Printed Circuit Board) 상에 실장하는 공정에서도 Sn-3.0Ag-0.5Cu 및 Sn-1.2Ag-0.5Cu-0.4In의 두 종류의 솔더 페이스트가 사용되었다. 본 연구에서의 내 충격 신뢰성 시험에는 자체 제작한 rod drop 시험기를 사용하였는데, 고정된 CSP 실장 board의 후면 부위를 일정한 높이에서 추를 반복적으로 자유 낙하시켜 급격한 충격을 주는 방식으로 실험을 실시하였다. 이 때 추의 무게는 30g, 낙하 높이는 10cm 였으며, 추의 낙하 시 측정된 board 의 휨 변위량은 약 0.7mm로 측정되었다. 사용된 CSP와 PCB 는 모두 daisy chain 방식으로 연결되어 있기 때문에 저항측정기를 사용한 간단한 실시간 저항 측정 방법으로 시험 이력에 따른 파단부의 발생 시점과 대략의 위치를 손쉽게 확인할 수 있었다. 솔더 조인트의 파단 기준 저항값으로 $1000\Omega$을 설정하였으며. 각 조건 당 5 개 이상의 샘플에 대해 평가를 실시한 후 그 평균값을 조사하였다. 시험 결과 제안된 Sn-1.2Ag-0.5Cu-0.4In 조성은 대표적인 저 Ag 함유 조성인 Sn-1.0Ag-0.5Cu에 비해서는 떨어지는 내 충격 신뢰성을 나타내었지만, 우수한 연성에 기인하여 Sn-3.0Ag-0.5Cu 조성에 비해서는 약 2 배 이상 우수한 신뢰성이 관찰되었다. 또한 CSP의 실장 시 Sn-3.0Ag-0.5Cu보다 Sn-1.2Ag-0.5Cu-0.4In 조성 솔더 페이스트를 적용한 경우에서 보다 우수한 내 충격 신뢰성을 나타내어 기본적으로 개발된 Sn-1.2Ag-0.5Cu-0.4In 솔더 페이스트가 Sn-3.0Ag-0.5Cu 조성의 기존 솔더 페이스트 보다 내 충격 신뢰성이 우수함을 검증할 수 있었다. 각 조성의 솔더 조인트를 $150^{\circ}C$ 에서 500시간 aging한 후 실시한 내 충격 신뢰성 평가에서는 모든 조성에서 그 신뢰성이 급감하는 경항을 나타내었으나, Sn-1.2Ag-0.5Cu-0.4In가 Sn-l.0Ag-0.5Cu보다도 그 상대적인 신뢰성이 우수한 것으로 관찰되었다. 이와 같이 aging 후 실시하는 충격시험은 가장 실제적인 상황과 유사한 조건이므로 상기의 실험 결과는 매우 고무적이었으며, 이에 대한 보다 면밀한 분석이 요청되었다. 마지막으로 파면 및 미세조직 관찰을 통하여 각 조성에서의 충격 파단 특성을 비교, 분석해 보았다.

  • PDF

Real-time Nutrient Monitoring of Hydroponic Solutions Using an Ion-selective Electrode-based Embedded System (ISE 기반의 임베디드 시스템을 이용한 실시간 수경재배 양액 모니터링)

  • Han, Hee-Jo;Kim, Hak-Jin;Jung, Dae-Hyun;Cho, Woo-Jae;Cho, Yeong-Yeol;Lee, Gong-In
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.141-152
    • /
    • 2020
  • The rapid on-site measurement of hydroponic nutrients allows for the more efficient use of crop fertilizers. This paper reports on the development of an embedded on-site system consisting of multiple ion-selective electrodes (ISEs) for the real-time measurement of the concentrations of macronutrients in hydroponic solutions. The system included a combination of PVC ISEs for the detection of NO3, K, and Ca ions, a cobalt-electrode for the detection of H2PO4, a double-junction reference electrode, a solution container, and a sampling system consisting of pumps and valves. An Arduino Due board was used to collect data and to control the volume of the sample. Prior to the measurement of each sample, a two-point normalization method was employed to adjust the sensitivity followed by an offset to minimize potential drift that might occur during continuous measurement. The predictive capabilities of the NO3 and K ISEs based on PVC membranes were satisfactory, producing results that were in close agreement with the results of standard analyzers (R2 = 0.99). Though the Ca ISE fabricated with Ca ionophore II underestimated the Ca concentration by an average of 55%, the strong linear relationship (R2 > 0.84) makes it possible for the embedded system to be used in hydroponic NO3, K, and Ca sensing. The cobalt-rod-based phosphate electrodes exhibited a relatively high error of 24.7±9.26% in the phosphate concentration range of 45 to 155 mg/L compared to standard methods due to inconsistent signal readings between replicates, illustrating the need for further research on the signal conditioning of cobalt electrodes to improve their predictive ability in hydroponic P sensing.

PROPERTIES OF CALCIUM HYDROXIDE-EUGENOL COMPOUND (수산화칼슘-유지놀 화합물의 물성)

  • Park, Joon-Chol;Kwon, Tae-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.408-415
    • /
    • 1999
  • When a zinc-oxide eugenol type sealer was placed in root canals treated previously with calcium hydroxide, acceleration of its setting and the yellowish discoloration were observed clinically. The purpose of this study was to evaluate the properties of calcium hydroxide-eugenol compound. Some physical properties of calcium hydroxide-eugenol compound were compared with a manufactured zinc-oxide eugenol based root canal sealer, Tubli-seal$^{(R)}$ in terms of water solubility, water sorption, film thickness and microleakage. Solubility and water sorption were determined by the use of the method described in American Dental Association Specification(ADAS) no. 57. Ten samples of each material were prepared into disks 20mm in diameter and 1.5mm in thickness. The samples were immersed in 50ml of distilled water at $37{\pm}1^{\circ}C$ for 7 days. The samples were then removed and placed in a desiccator. The values for solubility and water sorption were calculated using differences between the weights of same sample. Film thickness was determined by the use of the method described in ADAS no. 57 too. A small quantity of mixed cement was placed between two glass plates of which thickness was measured previously. 15Kg loading was applied and total thickness of the glass plates and the cement film was measured. The thickness difference was recorded as the material's film thickness. Microleakage was determined with a dye penetration method. Experimental materials were placed between the dentin surface of bovine tooth and the acrylic rod. These units were immersed in Pelican ink (W-Germany) for three days. Dye-penetrated dentin surfaces of bovine tooth were measured using the NIB Image 1.60 Macintosh program. The results are as follows: 1. Water solubility value of calcium hydroxide-eugenol compound (20.98${\pm}$2.94%) was statistically higher than those of Tubli-seal$^{(R)}$(2.52${\pm}$0.49%)(p<0.05). 2. Water sorption value of calcium hydroxide-eugenol compound (59.72${\pm}$17.75%) was statistically higher than those of Tubli-seal$^{(R)}$(3.15${\pm}$0.76%)(p<0.05). 3. Film thickness value of calcium hydroxide-eugenol compound (0.36${\pm}$0.03mm) was statistically higher than those of Tubli-seal$^{(R)}$(0.12${\pm}$0.1mm)(p<0.05). 4. Dye penetration value after 3 days-immersion of calcium hydroxide-eugenol compound(57.63${\pm}$25.85%) was statistically higher than those of Tubli-seal$^{(R)}$(28.05${\pm}$23.46%)(p<0.05).

  • PDF

Evaluation of Usefulness of Iterative Metal Artifact Reduction(IMAR) Algorithm In Proton Therapy Planning (양성자 치료계획에서 Iterative Metal Artifact Reduction(IMAR) Algorithm 적용의 유용성 평가)

  • Han, Young Gil;Jang, Yo Jong;Kang, Dong Heok;Kim, Sun Young;Lee, Du Hyeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.49-56
    • /
    • 2017
  • Purpose: To evaluate the accuracy of the Iterative Metal Artifact Reduction (IMAR) algorithm in correcting CT (computed tomography) images distorted due to a metal artifact and to evaluate the usefulness when proton therapy plan was plan using the images on which IMAR algorithm was applied. Materials and Methods: We used a CT simulator to capture the images when metal was not inserted in the CIRS model 062 Phantom and when metal was inserted in it and Artifact occurred. We compared the differences in the CT numbers from the images without metal, with a metal artifact, and with IMAR algorithm by setting ROI 1 and ROI 2 at the same position in the phantom. In addition, CT numbers of the tissue equivalents located near the metal were compared. For the evaluation of Rando Phantom, CT was taken by inserting a titanium rod into the spinal region of the Rando phantom modelling a patient who underwent spinal implant surgery. In addition, the same proton therapy plan was established for each image, and the differences in Range at three sites were compared. Results: In the evaluation of CIRS Phantom, the CT numbers were -6.5 HU at ROI 1 and -10.5 HU at ROI 2 in the absence of metal. In the presence of metal, Fe, Ti, and W were -148.1, -45.1 and -151.7 HU at ROI 1, respectively, and when the IMAR algorithm was applied, it increased to -0.9, -2.0, -1.9 HU. In the presence of metal, they were 171.8, 63.9 and 177.0 HU at ROI 2 and after the application of IMAR algorithm they decreased to 10.0 6,7 and 8.1 HU. The CT numbers of the tissue equivalents were corrected close to the original CT numbers except those in the lung located farthest. In the evaluation of the Rando Phantom, the mean CT numbers were 9.9, -202.8, and 35.1 HU at ROI 1, and 9.0, 107.1, and 29 HU at ROI 2 in the absence, presence of metal, and in the application of IMAR algorithm. The difference between the absence of metal and the range of proton beam in the therapy was reduced on the average by 0.26 cm at point 1, 0.20 cm at point 2, and 0.12 cm at point 3 when the IMAR algorithm was applied. Conclusion: By applying the IMAR algorithm, the CT numbers were corrected close to the original ones obtained in the absence of metal. In the beam profile of the proton therapy, the difference in Range after applying the IMAR algorithm was reduced by 0.01 to 3.6 mm. There were slight differences as compared to the images absence of metal but it was thought that the application of the IMAR algorithm could result in less error compared with the conventional therapy.

  • PDF

Monitoring the Rate of Frozen Denaturation of Bovine Myosin by Competitive Indirect ELISA Method (Competitive Indirect ELISA를 이용한 Bovine Myosin의 동결 변성도 측정)

  • Kim, Seong-Bae;Lee, Ju-Woon;Park, Jong-Heum;Do, Hyung-Ki;Hyun, Chang-Kee;Shin, Heuyn-Kil
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.862-870
    • /
    • 1998
  • This study shows the application of Ci-ELISA method for monitoring the denaturation of myosin by the frozen treatment in order to differentiate thawed beef from chilled. Hanwoo M.Semitendinosus (n=25) was treated under the two different frozen process as follows; simple frozen treatment (Exp-1) at 4 different temperatures, -10, -20, -50 and $-80^{\circ}C$, respectively, and repeated thawing-refreezing treatment (Exp-2) stored at 4 different temperatures, -10, -20, -50 and $-80^{\circ}C$, respectively. Antibodies (Abs) were produced from rabbits immunized with myosin whole molecule (MWM) isolated from beef round, heavy meromyosin S-1 (S-1) and light meromyosin (LMM) prepared by digestion of MWM. Each immunoglobulin G (IgG) was separated from antiserum. At 6 month storage, IA of anti-MWM IgG for myosin was decreased to 32.67, 32. 23, 51.52 and 34.27% in Exp-1 and to 14.82, 15.61, 25.3 and 23.7% in Exp-2 at -10, -20, -50 and $-80^{\circ}C$, respectively (P<0.05). In Exp-1, the reactivities of anti-LMM IgG were decreased to 25.12, 21.42, 49.05 and 28.96%, and those of Exp-2 were to 11.88, 9.56, 20.63 and 12.64% at -10, -20, -50 and $-80^{\circ}C$, respectively, at 6 times thawing (P<0.05). Conclusively, myosin was denaturated by freezing treatment and LMM or myosin rod part might have suffered from more extreme demage than HMM S-1, and samples at $-50^{\circ}C$ were slightly injured less than others by freezing treatment.

  • PDF

A STUDY ON THE JUJEON OF AUTOMATIC CLEPSYDRA IN EARLY JOSEON DYNASTY (조선 전기 자동물시계의 주전(籌箭) 연구)

  • YUN, YONG-HYUN;KIM, SANG HYUK;MIHN, BYEONG-HEE;OH, KYONG TAEK
    • Publications of The Korean Astronomical Society
    • /
    • v.36 no.3
    • /
    • pp.65-78
    • /
    • 2021
  • Jagyeokru, an automatic striking water clock described in the Sejong Sillok (Veritable Records of King Sejong) is essentially composed of a water quantity control device and a time-signal device, with the former controlling the amount or the flow rate of water and the latter automatically informing the time based on the former. What connects these two parts is a signal generating device or a power transmission device called the 'Jujeon' system, which includes a copper rod on the float and ball-racked scheduled plates. The copper products excavated under Gongpyeong-dong in Seoul include a lot of broken plate pieces and cylinder-like devices. If some plate pieces are put together, a large square plate with circular holes located in a zigzag can be completed, and at the upper right of it is carved 'the first scheduled plate (一箭).' Cylinder-like devices generally 3.8 cm in diameter are able to release a ball, and have a ginkgo leaf-like screen fixed on the inner axis and a bird-shaped hook of which the leg fixes another axis and the beak attaches to the leaf side. The lateral view of this cylinder-like device appears like a trapezoid and mounts an iron ball. The function of releasing a ball agrees with the description of Borugak Pavilion, where Jagyeokru was installed, written by Kim Don (1385 ~ 1440). The other accounts of Borugak Pavilion's and Heumgyeonggak Pavilion's water clocks describe these copper plates and ball releasing devices as the 'Jujeon' system. According to the description of Borugak Pavilion, a square wooden column has copper plates on the left and right sides the same height as the column, and the left copper plate has 12 drilled holes to keep the time of a 12 double-hours. Meanwhile, the right plate has 25 holes which represent seasonal night 5-hours (Kyeong) and their 5-subhours (Jeom), not 12 hours. There are 11 scheduled plates for seasonal night 5-hours made with copper, which are made to be attached or detached as the season. In accordance with Nujutongui (manual for the operation of the yardstick for the clepsydra), the first scheduled plate for the night is used from the winter solstice (冬至) to 2 days after Daehan (大寒), and from 4 days before Soseol (小雪) to a day before the winter solstice. Besides the first scheduled plate, we confirm discovering a third scheduled plate and a sixth scheduled plate among the excavated copper materials based on the spacing between holes. On the other hand, the width of the scheduled plate is different for these artifacts, measured as 144 mm compared to the description of the Borugak Pavilion, which is recorded as 51 mm. From this perspective, they may be the scheduled plates for the Heumgyeonggak Ongru made in 1438 (or 1554) or for the new Fortress Pavilion installed in Changdeokgung palace completed in 1536 (the 31st year of the reign of King Jungjong) in the early Joseon dynasty. This study presents the concept of the scheduled plates described in the literature, including their new operating mechanism. In addition, a detailed model of 11 scheduled plates is designed from the records and on the excavated relics. It is expected that this study will aid in efforts to restore and reconstruct the automatic water clocks of the early Joseon dynasty.

Preparation of Halloysite-Based Tubular Media for Enhanced Methylene Blue Adsorption (메틸렌 블루 흡착능 향상을 위한 할로이사이트 기반 튜브형 담체 연구)

  • Jeon, Junyeong;Cho, Yebin;Kim, Jongwook;Shin, Seung Gu;Jeon, Jong-Rok;Lee, Younki
    • Clean Technology
    • /
    • v.27 no.4
    • /
    • pp.359-366
    • /
    • 2021
  • Halloysite nanotubes (HNTs), the multiwalled clay mineral with the composition of Al2Si2O5(OH)4·nH2O, have been highlighted as a low-cost adsorbent for the removal of dyes from wastewater. Although a powder of halloysite presents a high specific surface area, forming media are significantly considered due to sludge-clogging induced by the water-bound agglomeration. However, higher firing temperature to achieve the structural durability of the media and lower utilization rate due to longer penetration depth into the media act as hurdles to increase the dye-adsorption capacity. In this work, the retention of the adsorption capacity of halloysite was evaluated with methylene blue solution after the heat treatment at 750 ℃. In order to improve the utilization rate, tubular media were fabricated by extrusion. The images taken by transmission electron microscopy show that HNTs present excellent structural stability under heat treatment. The HNTs also provide superb capacity retention for MB adsorption (93%, 18.5 mg g-1), while the diatomite and Magnesol® XL show 22% (7.65 mg g-1) and 6% (11.7 mg g-1), respectively. Additionally, compositing with lignin enhances adsorption capacity, and the heat treatment under the hydrogen atmosphere accelerates the adsorption in the early stage. Compared to the rod-type, the tubular halloysite media rapidly increases methylene blue adsorption capacity.