• 제목/요약/키워드: Robot skin

검색결과 60건 처리시간 0.029초

850 nm 파장대 근적외선과 갈바닉 전류기반의 눈가 주름 치료기 개발 및 영상 분석을 통한 치료성능 검증 (Design of 850 nm Near Infrared and Galvanic Current Based Eyeglass-Type Device for Periorbital Wrinkle Treatment and Verification of Treatment Performance through Image Analysis)

  • 안성수;권기진
    • 한국멀티미디어학회논문지
    • /
    • 제21권12호
    • /
    • pp.1379-1386
    • /
    • 2018
  • In this paper, we proposed eyeglass type periorbital wrinkle treatment device for reducing and improving periorbital wrinkles using near infrared LED of 850nm wavelength and galvanic current. The proposed periorbital wrinkle treatment device is equipped with a control system based on F-PCB. It consists of eight near-infrared LEDs and four indicator LEDs for treatment of right and left periorbital wrinkles. The eyeglass frame is coated with conductive material, so galvanic current can flow to the skin of periorbital wrinkle contacted to it. One male adult in the mid-40s was allowed to use the device for 10 minutes every day for 4 weeks. After 4 weeks, image analysis using optical equipment for measuring wrinkles indicated that wrinkle indexes were reduced.

Flexible Pressure Sensors Based on Three-dimensional Structure for High Sensitivity

  • Jung, Young;Cho, Hanchul
    • 센서학회지
    • /
    • 제31권3호
    • /
    • pp.145-150
    • /
    • 2022
  • The importance of flexible polymer-based pressure sensors is growing in fields like healthcare monitoring, tactile recognition, gesture recognition, human-machine interface, and robot skin. In particular, health monitoring and tactile devices require high sensor sensitivity. Researchers have worked on sensor material and structure to achieve high sensitivity. A simple and effective method has been to employ three-dimensional pressure sensors. Three-dimensional (3D) structures dramatically increase sensor sensitivity by achieving larger local deformations for the same pressure. In this paper, the performance, manufacturing method, material, and structure of high-sensitivity flexible pressure sensors based on 3D structures, are reviewed.

Transcutaneous medial fixation sutures for free flap inset after robot-assisted nipple-sparing mastectomy

  • Kim, Bong-Sung;Kuo, Wen-Ling;Cheong, David Chon-Fok;Lindenblatt, Nicole;Huang, Jung-Ju
    • Archives of Plastic Surgery
    • /
    • 제49권1호
    • /
    • pp.29-33
    • /
    • 2022
  • The application of minimal invasive mastectomy has allowed surgeons to perform nipples-paring mastectomy via a shorter, inconspicuous incision under clear vision and with more precise hemostasis. However, it poses new challenges in microsurgical breast reconstruction, such as vascular anastomosis and flap insetting, which are considerably more difficult to perform through the shorter incision on the lateral breast border. We propose an innovative technique of transcutaneous medial fixation sutures to help in flap insetting and creating and maintaining the medial breast border. The sutures are placed after mastectomy and before flap transfer. Three 4-0 nylon suture loops are placed transcutaneously and into the pocket at the markings of the preferred lower medial border of the reconstructed breast. After microvascular anastomosis and temporary shaping of the flap on top of the mastectomy skin, the three corresponding points for the sutures are identified. The three nylon loops are then sutured to the dermis of the corresponding medial point of the flap. The flap is placed into the pocket by a simultaneous gentle pull on the three sutures and a combined lateral push. The stitches are then tied and buried after completion of flap inset.

HOG를 이용한 파트 기반 손 검출 알고리즘 (Part-based Hand Detection Using HOG)

  • 백정현;김지수;윤창용;김동연;김은태
    • 한국지능시스템학회논문지
    • /
    • 제23권6호
    • /
    • pp.551-557
    • /
    • 2013
  • 지능형 로봇 연구 분야에 있어, 손을 이용한 제스처 인식은 매우 중요한 연구 분야로 간주 되고 있으며, 스마트 폰, 스마트 TV 등에 상용화 되어왔다. 제스처 인식에 있어, 강인한 손 검출 기술을 필수적인데, 손의 모양이 일정치 않고, 복잡한 배경이나 조명변화 아래서는 손 검출이 쉽지 않다는 어려움이 있다. 본 논문은 실내 환경에서 사용자가 가리키는 방향을 인식하기 위한 손 검출 알고리즘을 제안한다. 손 검출에 대한 오검출을 최대한 줄이기 위해, 머리-어깨 검출 결과를 기반으로 손 검색 영역을 한정시키고, 피부색을 이용해 최소한의 후보군들을 발생시켜, HOG-SVM을 이용하여 손을 검출하였다. 그리고 머리-어깨, 손 검출 결과를 통해 팔의 방향 각도를 추정하였다. 제안된 방법은 실제 실내 환경에서 추출된 영상을 통해 실험을 진행하였고, 강인한 성능을 확인하였다.

DaVinci SP-based simultaneous bilateral partial nephrectomy from the midline transperitoneal approach: a case report

  • Young Hwii Ko;Jong Gyun Ha;Jae Yoon Jang;Yeung Uk Kim
    • Journal of Yeungnam Medical Science
    • /
    • 제41권1호
    • /
    • pp.48-52
    • /
    • 2024
  • While simultaneous bilateral partial nephrectomy with a conventional multiport robot has been consistently reported since the 2010s, the introduction of the DaVinci SP system (Intuitive Surgical, Sunnyvale, CA, USA) could provide a novel way to perform surgery on bilateral kidneys while innovatively reducing the number of incisions. In our first report worldwide, the patient with bilateral small renal mass (2.0 cm for the left and 1.5 cm for the right side) and preoperative normal renal function was placed in the lateral decubitus position on an inverted bed. After tilting the bed to be as horizontal as possible, a 4-cm incision was made in the lower part of the umbilicus for the floating trocar technique. The partial nephrectomy was performed reliably as with the conventional transperitoneal approach, and then the patient could be repositioned to the contralateral side for the same procedure, maintaining all trocars. Total operation time (skin to skin), total console time, and the left- and right-side warm ischemic times were 260, 164, 27, and 23 minutes, respectively, without applying the early declamping technique. The estimated blood loss was 200 mL. The serum creatinine right after the operation, on the first day, 3 days, and 90 days after surgery were 0.92, 0.77, 0.79, and 0.81 mg/dL, respectively. For 90 days after the procedure, no complications or radiologic recurrence were observed. Further clinical studies will reveal the advantages of using the DaVinci SP device for this procedure over traditional multiport surgery, maximizing the benefit of a single port-based approach.

정전 발전 기반 소프트 로봇 응용 최신 기술 (Recent Advances on TENG-based Soft Robot Applications)

  • 성정빈;최덕현
    • Composites Research
    • /
    • 제35권6호
    • /
    • pp.378-393
    • /
    • 2022
  • 마찰전기 나노발전기(이하 TENG)의 새로운 발전 기술은 에너지 수집 및 자가 전력 공급 감지 응용 분야의 긍정적 전망으로 인해 점점 더 많은 관심을 받고 있다. 또한 최근 소프트로봇의 부상은 플렉시블과 소프트센서, 액추에이터 개발에 대한 폭넓은 관심을 불러 일으키고 있다. TENG는 액추에이터와 자가 전력 공급 센서를 구동하는 유망한 전원으로 간주되어 소프트웨어 로봇, 소프트 센서 및 액추에이터 개발을 위한 독창적인 방법을 제공한다. 이 리뷰에서는 TENG를 기반으로 다양한 형태와 기능을 가진 소프트웨어 로봇을 소개하려 한다. 그 중 자연계의 구조, 표면 형태, 재료 특성과 센싱/발전 메커니즘을 모방한 바이오닉 소프트 로봇의 설계는 TENG 성능 향상에 큰 도움이 되었다. 또한 다양한 바이오닉 소프트 로봇은 TENG의 간단한 구조, 자체 전력 공급 특성 및 조정 가능한 출력으로 인해 이전 구동 방식보다 향상되었다. 그리하여 이 리뷰에서는 TENG가 활성화한 소프트 로봇 응용의 특정 핵심 영역에서 다양한 연구를 종합적으로 검토하려 한다. 리뷰를 요약하자면 먼저 최근 개발된 다양한 TENG 기반 소프트웨어 로봇을 정리하고 다양한 장비 구조, 표면 형태 및 자연적으로 영감을 받은 재료를 비교 분석하여 그에 따른 TENG 성능 개선을 수행한다. 자연계에 사용되는 다양한 유비쿼터스 감지 원리와 발전 메커니즘 및 유사한 인공 TENG 설계가 확인되었고 촉각 디스플레이 및 웨어러블 기기, 인공 전자 피부 등의 기기에 TENG를 활성화하는 바이오닉 응용에 대해 논의한다. 마지막으로 TENG 기반 센서 및 구동 장비의 로봇 실제 적용에 대한 발전 기회, 도전 및 미래 전망을 분석한다.

웹 로봇 에이전트의 하이퍼링크 분석기법을 이용한 음란메일 차단 시스템의 구현 (Implementation of Anti-Porn Spam System based on Hyperlink Analysis Technique's of the Web Robot Agent)

  • 이승만;정희석;한상;송우석;이도한;홍지영;반의환;양준영
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2007년도 한국컴퓨터종합학술대회논문집 Vol.34 No.1 (C)
    • /
    • pp.332-335
    • /
    • 2007
  • 이메일은 누구나 쉽게 정보를 교환할 수 있는 편리함 때문에 인터넷에서 가장 중요한 수단으로 사용되고 있다. 그러나 순수한 의사소통의 수단이 아닌 스팸메일의 범람은 성인뿐만 아니라, 어린이 청소년에게도 무차별적으로 전송됨으로써 심각한 부작용을 낳고 있다. 본 논문은 점차 지능화 되는 신 유형의 음란 스팸메일로부터 청소년을 보호하기 위하여 새로운 방법의 음란메일 차단시스템을 제안하고자 한다. 기존의 스팸메일 차단시스템은 사용자가 직접 음란한 메일이라고 판단되는 메일에 대해 일일이 키워드를 설정하거나, 메일 내용 중에 텍스트만을 추출하여 패턴 매칭방법으로 분류하는 것이 대부분이었지만, 본 논문은 기존 방법의 문제점을 해결하기 위하여 이미지 내 Skin-Color분포의 Human Detection 알고리즘과 웹 로봇 에이전트의 하이퍼링크 분석기법을 사용하였다. 성능 측정결과, 형태소 분석과 Human Detection 알고리즘을 병합하여 적용한 경우 성능 측정에서 90% 정도의 F-measure를 보였지만, 추가적으로 웹 로봇 에이전트의 하이퍼링크 분석기법을 병합하여 적용한 경우 97% 이상의 F-measure를 보이며, 신뢰성이 높은 음란스팸메일 차단 시스템을 구현할 수 있다는 것을 증명하였다.

  • PDF

근전도와 안전도 기반의 인간-기계 인터페이스기술 (Development of Human-machine Interface based on EMG and EOG)

  • 강경우;김태선
    • 전자공학회논문지
    • /
    • 제50권12호
    • /
    • pp.129-137
    • /
    • 2013
  • 최근 다양한 컴퓨터기반 장치들의 사용 확대에 따라 장애인에게도 정보접근의 용이성 확보가 요구되고 있다. 특히 사지를 움직일 수 없는 중증 장애인들을 위한 새로운 입력 인터페이스 기술의 개발이 절실히 요구된다. 이를 위해 본 논문에서는 중증 장애인이 활용 가능한 눈동자 움직임 및 깨물기를 통한 안전도(EOG)와 근전도(EMG)신호를 이용하여 아홉 가지의 명령이 가능한 인터페이스 시스템을 개발하였다. 구현된 시스템은 하드웨어로 구성된 센서모듈과 특징추출 및 패턴분류를 포함하는 소프트웨어부로 구성된다. 개발된 기술은 사용자의 편의성을 극대화하기 위해 두 개의 전극만을 이마부위에 부착하여 안전도와 근전도를 동시에 측정하고, 이를 통해 아홉 가지의 명령전달이 가능하도록 하였다. 성능평가를 위한 java 기반 실시간 모니터링 프로그램의 실험결과 92.52%의 인식률을 보였다. 또한, 구현된 시스템의 실용성을 입증하기 위해 다섯 종류의 명령을 이용하여 ER1 로봇의 조종에 성공적으로 적용 가능함을 보임으로써 장애인을 위한 새로운 인터페이스로서의 가능성을 보였다.

4차산업혁명과 한국대학의 역할 변화 (The 4th.industrial revolution and Korean university's role change)

  • 박상규
    • 융합정보논문지
    • /
    • 제8권1호
    • /
    • pp.235-242
    • /
    • 2018
  • 최근 각 언론, 기업계, 정부 유관기관 및 학계 등 많은 분야에서 4차 산업에 대한 관심이 폭발적으로 증가하였다. 특히 우리가 피부로 느낄 수 있는 분야인 인공지능이 인간능력을 이미 크게 앞서고 있다는 것을 깨닫고 나서 많은 사람들은 4차산업혁명이 실제로 우리 코 앞에 와있다는 것을 실감할 수 있었다. 이렇게 대부분 사람들의 생각보다 빠르게 다가온 4차산업을 어떻게 효율적으로 대응해야 할까? 특히 최근의 인공지능, 빅데이터, 무인자동차 및 유전자가위 등에 대한 상반된 견해들을 비교분석하는 방식으로 연구를 진행해 본다. 이러한 분석과 연구를 통하여 교육적, 정치적, 사회적, 윤리적 그리고 과학적 영향들을 파악해 본 결과, 현재까지 뚜렷하게 정립되어 있는 개념이나 체계, 시스템이 존재하지 않는다는 것을 이해할 수 있었고 오히려 4차산업혁명의 개념, 체계를 앞서서 정의하고 정립하는 국가나 기업, 개인들이 산업의 주도권을 확보할 수 있다는 것을 알게 되었다. 그러나 한국사회와 대학은 오히려 현재 2차산업혁명의 체계와 문화에서 머물러있는 듯한 모습을 보이고 있는데, 이러한 현실인식 위에서 새로운 산업혁명의 트렌드를 맞추어 따라갈 수 있는 방안들을 찾아 보고자 한다.

치의학 교육을 위한 프로토타입 시뮬레이터의 개발 (Development of a prototype simulator for dental education)

  • 김미엘;심재훈;에인 몬;김명주;박영석;권호범;박재흥
    • 대한치과보철학회지
    • /
    • 제61권4호
    • /
    • pp.257-267
    • /
    • 2023
  • 목적. 이 연구의 목적은 치의학 교육을 위한 프로토타입 로봇 시뮬레이터를 제작하고, 하악운동을 시뮬레이션 할 수 있는지 여부를 테스트하며, 치과실습 중 자극에 대한 시뮬레이터의 반응 가능성을 평가하는 것이었다. 재료 및 방법. 가상 시뮬레이터 모델은 cone-beam computed tomography (CBCT) 데이터를 사용하여 경조직을 구획화한 후 제작되었다. 시뮬레이터의 프레임은 polylactic acid (PLA) 소재를 사용하여 3D 프린팅 되었으며, 덴티폼과 실리콘 얼굴 스킨을 장착하여 모델을 형성하였다. 서보 액추에이터는 시뮬레이터의 움직임을 제어하는데 사용되었고, 다양한 센서들로 시뮬레이터의 반응을 생성하였다. 수위 센서가 반응하는 물의 양을 측정하기 위해 수위테스트가 수행되었다. 또한, 컴퓨터 시뮬레이션과 실제 모델을 통해 시뮬레이터의 하악운동과 하악운동 범위를 테스트하였다. 결과. 프로토타입 로봇 시뮬레이터는 작동 장치, 전기 장치가 있는 상반신, 턱관절을 포함하는 머리 및 덴티폼으로 구성되었다. 시뮬레이터의 턱관절은 회전 및 병진 운동을 구현하면서 2자유도를 구동할 수 있었다. 수위 테스트에서 수위 센서의 특정 임계값은 10.35 ml였다. 컴퓨터 시뮬레이션과 실제 모델 모두에서 인간의 움직임을 모방하였고, 시뮬레이터의 하악운동 시 개구범위는 50 mm였다. 결론. 효율성과 안정성을 개선하기 위해서는 더 많은 발전이 필요하지만, 본 상반신 프로토타입의 시뮬레이터는 향후 치과실습 교육에 잠재적으로 유용할 것으로 기대된다.