• Title/Summary/Keyword: Road solar

Search Result 65, Processing Time 0.025 seconds

Measurement and Analysis of Heat Island in summer in Gwangju (광주지역의 여름철 열섬현상 측정 및 분석)

  • Park, Seok-Bon
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.4
    • /
    • pp.65-75
    • /
    • 2004
  • This study aims to identify the degree of heat island in summer in Gwangju. For the purpose the city was classified according to use and surface components and temperature of the city for 24 hours was measured. The period of measurement was from August 11 to 13. 2003(two days). As a result of the measurement, the daily standard temperature of the central business areas and downtown areas was about $26^{\circ}C$. That of new residential areas neighboring the downtown was $25.1^{\circ}C$, and that of the outer residential areas was $23.4^{\circ}C$. In comparison with the result that temperatures of the Gwangju University playground and the Gwangju Weather Bureau were $23.1^{\circ}C$ and $23.3^{\circ}C$ respectively, the temperature of the downtown was about $2.7^{\circ}C$ Higher and that of the new residential area in downtown was about $1.8^{\circ}C$ higher. And it was demonstrated that the downtown outer road under Mt. Mudeung is a low-temperature zone. When temperature of the city was measured based on surface components, the daily standard temperature of Gwangju Stream Bok-gae area was the highest, $24.2^{\circ}C$, followed by $23.6^{\circ}C$ of the downtown stream and $22.2^{\circ}C$ of the greens (city park) and the waterside area.

A Case Study on Energy Consumption and Calibration of Green Remodeling Buildings (그린리모델링 건물에 대한 에너지소비량 및 보정 사례연구)

  • Kim, Dongi;Lee, Byeongho
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.5
    • /
    • pp.47-58
    • /
    • 2020
  • Ministry of Land, Infrastructure and Transport(MOLIT) has increased reduction rate from 18.1% to 32.7% in Building sector compared to BAU of the national greenhouse gas emission according to the 2030 Greenhouse Gas Reduction Road map Amendment. For this purpose, MOLIT has been activating the green remodeling projects for existing buildings. Considering that 15 year old buildings after completion are 74% (5.25 million buildings) among about 7 million existing building stocks in Korea, reduction of building energy consumption by green remodeling is urgently needed, However, it is a major difficulty of activation for green remodeling projects because there are few case studies on Before and After building energy consumption of actual green remodeling projects. Considering that building energy performance and value increase after green remodeling through previous researches, additional studies of the energy consumption assessment on actual green remodeling projects are essential. Therefore, this study aims to propose results on Before and After building energy consumption of actual green remodeling projects.

Development of Convergence LED Streetlight and Speed Bump Using Solar Cell and Piezoelectric Element (태양광과 압전소자를 이용한 융복합 LED 발광 과속방지턱 겸용 가로등 개발)

  • Nahm, Eui-Seok;Cho, Han-Jin
    • Journal of Digital Convergence
    • /
    • v.14 no.5
    • /
    • pp.325-331
    • /
    • 2016
  • In driving at evening or night, we are not able to recognize the speed bump and so stop suddenly. It could result in accidents. And also, we have a restriction of street light installation in farm road because it could be harmful to the crops and driver could not recognize the walking people. It needs to develop the speed bump with light and streetlight to be non harmful to the crops. So, we develop both the speed bump and streetlight with LED which could be non harmful to the crops and be increased recognition of walking people in farm road. For LED lighting power, we use the solar cells, and piezoelectric elements. It has automatic on/off according to power saving rates without illumination sensor. Minimization of circuit elements and design of minimum resisters and low power LED was used for power saving in assuring 3-days.

Study on Remote control and monitoring system of the multipurpose guard rail using USN (USN을 이용한 다목적 가드레일의 원격제어 및 모니터링 시스템에 관한 연구)

  • Song, Je-Ho;Lee, In-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.7176-7181
    • /
    • 2015
  • This thesis is about the system where the solar module is attached to the high functional guardrail posts with anti-weed, anti-plant, and road-kill applied to produce internal power, enabling the integrated control and real-time monitoring of appearance of wildlife and road conditions using the USN. The whole system consists of a photovoltaic module(PV), a detection sensor(pyroelectric), a controller(operation select and motion sensor), the USN system, the DB(sound and flash), an output unit of sound and flash, and the control system of road-kill prevention and safety induction for vehicles. Thus this study aims to address the remote control and monitoring system of multipurpose guardrails to improve road environment, prevent road-kills, protect wild animals, and guide cars safely by using the USN which is combined with new renewable energy and IT convergence technology. As a result of the study on the remote control and monitoring system using the USN, it was ascertained that the response time of the unmanned sensing system was within 5.1 ms with the current consumption of 0.328 mA, and the data transmission speed of the remote control system was 250 kbps with the current consumption of 0.283 mA.

Design and Application of Traffic Safety Technology in Chungcheong non-urban Region (충청권 비도심 지역의 교통안전기술 설계 및 적용)

  • Cho, Choong-Yeon;Kim, Yun-Sik;Lee, Min-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.264-272
    • /
    • 2016
  • In previous research, we analyzed traffic accident characteristics in the Chungcheong region through factor analysis, cluster analysis, and a questionnaire using traffic accident analysis system data to enhance Korea's traffic safety. Based on the analysis results, we investigated the design and application of traffic safety technology in non-urban areas in this study. Three technologies are proposed to improve traffic safety facilities for the region: a recognition light at pedestrian crossing works, a recognition light on the road for the underprivileged in traffic works, and a safety LED sign for operation of agricultural machine works. Each technology complements the light pollution problem about snow removal and road safety when applied to existing facilities in the non-urban areas. Solar-based indigenous technology is expected to contribute to road safety in rural areas.

Lighting performance of high reflection wall within covered sunken garden (천창이 있는 선큰가든의 고반사율 벽면에 의한 심도 공간 채광성능)

  • Lim, Hong-Soo;Kim, Gon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.19-26
    • /
    • 2009
  • This study is performed by method for the influx of natural light in underground space. to solve the several negative underground issues make the covered courtyard and high reflected wall toward the adjacent space. for illuminance level test of sunken garden space, the adjacent space size is $15M{\times}9M{\times}12M$ sunken Garden with space to install the ceiling on the size of the companion light performance analysis, and seasonal changes derived by the light of changes in performance. In addition, increase the distance of the wall and the adjacent space and estimate the average at true time P.M12. The resulting data indicate that the road was an average lux DESKTOP RADIANCE of the modeling and analysis was conducted.

  • PDF

Estimation Method of Wind Resource Potential in South Korea (남한 풍력자원 잠재량 산정방법)

  • Kim, Hyun-Goo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.310-313
    • /
    • 2008
  • The wind resource potentials of South Korea are estimated as preliminary stage using the national wind map which has been being established by numerical wind simulation and GIS (Geographical Information System) exclusion analysis. The wind resource potentials are classifying into theoretical, geographical, technical and implementation potentials and the calculation results are verified by comparing to other countries' potentials. In GIS exclusion, urban, road, water body, national parks and steep slope area are excluded from onshore geographical potential while water depth and offshore distance from the shoreline are applied s offshore exclusion conditions. To estimate implementation potential, dissemination records of European countries are adopted which is about 1/8 of geographical potential.

  • PDF

Evaluation of NOx Removal Efficiency of Photocatalytic Concrete for Road Structure (도로구조물 적용을 위한 광촉매 콘크리트의 질소산화물(NOx) 제거효율 평가)

  • Kim, Young Kyu;Hong, Seong Jae;Lee, Kyung Bae;Lee, Seung Woo
    • International Journal of Highway Engineering
    • /
    • v.16 no.5
    • /
    • pp.49-58
    • /
    • 2014
  • PURPOSES : In areas of high traffic volume, such as expressway across large cities, the amount of nitrogen oxides (NOx) emitted into the atmosphere as air pollution can be significant since NOx gases are the major cause of smog and acid rain. Recently, the importance of NOx removal has arisen in the world. Titanium dioxide ($TiO_2$), that is one of photocatalytic reaction material, is very efficient for removing NOx. The NOx removing mechanism of $TiO_2$ is the reaction of solar photocatalysis. Therefore, $TiO_2$ in road structure concrete need to be contacted with ultraviolet rays (UV) to be activated. In general, $TiO_2$ concretes are produced by replacement of $TiO_2$ as a part of concrete binder. However, considerable portion of $TiO_2$ in concrete cannot contact with the pollutant in the air and UV. Therefore, $TiO_2$ penetration method using the surface penetration agents is attempted as an alternative in order to locate $TiO_2$ to the surface of concrete structure. METHODS : This study aimed to evaluate the NOx removal efficiency of photocatalytic concrete due to various $TiO_2$ application method such as mix with $TiO_2$, surface spray($TiO_2$ penetration method) on hardened concrete and fresh concrete using surface penetration agents. The NOx removal efficiency of $TiO_2$ concrete was confirmed by NOx Analyzing System based on the specification of ISO 22197-1. RESULTS : The NOx removal efficiency of mix with $TiO_2$ increased from 11 to 25% with increasing of replacement ratio from 3 to 7%. In case of surface spray on hardened concrete, the NOx removal efficiency was about 50% due to application amount of $TiO_2$ with surface penetration agents as 300, 500 and 700g/m2. The NOx removal efficiency of surface spray on fresh concrete due to all experimental conditions, on the other hand, which was very low within 10%. CONCLUSIONS : It was known that the $TiO_2$ penetration method as surface spray on hardened concrete was a good alternative in order to remove the NOx gases for concrete road structures.

A NUMERICAL STUDY ON THE EFFECT OF DOWN-WASH OF A WING-BODY ON ITS AERODYNAMIC CHARACTERISTICS (익형 동체의 하강기류(Down-wash)가 공기역학적 특성에 미치는 영향에 관한 수치해석연구)

  • Yoon, K.H.;Kim, C.H.
    • Journal of computational fluids engineering
    • /
    • v.18 no.3
    • /
    • pp.8-13
    • /
    • 2013
  • Drag reduction of a running vehicle is very important issue for the energy savings and emission reduction of its power train. Especially for a solar powered electric vehicle, the drag reduction and weight lightening are two serious problems to be solved to extend its driving distance under the given energy condition. In this study, the ground effect of an airfoil shaped road vehicle was studied for an optimum body design of an ultra-light solar powered electric vehicle. Clark-Y airfoil type was adopted to the body shape of the model vehicle to reduce aerodynamic drag. From the study, it was found that the drag of the model vehicle was reduced as the height(h) between ground and the lower surface of the model vehicle was decreased. It is due to the reduction of the down-wash decreasing the induced drag of the vehicle. The lift was also decreased as the height decreased. It is due to the turbulent boundary layer developed beneath the vehicle body. The drag is classified into two types; the form and friction drag. The fraction of form drag to friction one is 76 to 24 on the model vehicle. As the height(h) of the model vehicle from the ground surface increases the form drag also increases but the friction drag is in reverse.

Building Integrated Vegetation Systems into the New Sainsbury's Building Based on BIM

  • Lee, Dong-Kyu
    • Journal of KIBIM
    • /
    • v.4 no.2
    • /
    • pp.25-32
    • /
    • 2014
  • Today, there is a growing need of environment-friendly buildings, so-called 'green', facilities, and energy saving buildings to decrease environmental pollutants released into cities by construction activities. Green-Building Information Modeling (Green-BIM) is a purpose-built solution which supports to forecast energy consumption of 3-D model of a building by augmenting its primary 3-D measurements (width, height and depth) with many more dimensions (e.g. time, costs, social impacts and environmental consequences) throughout a series of sequential phases in the lifecycle of a building. The current study was carried out in order to integrate vegetation systems (particularly green roof and green wall systems) and investigate thermal performance of the new Sainsbury's building which will be built on Melton road, Leicester, United Kingdom. Within this scope, a 3-D building model of the news Sainsbury's building was first developed in $Autodesk^{(R)}$ $Revit^{(R)}$ and this model was then simulated in $Autodesk^{(R)}$ $Ecotect^{(R)}$once weather data of the construction site was obtained from $Autodesk^{(R)}$ Green Building $Studio^{(R)}$. This study primarily analyzed data from (1) solar radiation, (2) heat gains and losses, and (3) heating and cooling loads simulation to evaluate thermal performance of the building integrated with vegetation system or conventionally available envelops. The results showed that building integrated vegetation system can potentially reduce internal solar gains on the building rooftops by creating a 'bioshade'. Heat gains and losses through roofs and walls were markedly diminished by offering greater insulation on the building. Annual energy loads for heating and cooling were significantly reduced by vegetation more significantly through the green roof system in comparison to green wall system.