• Title/Summary/Keyword: Road dust

Search Result 122, Processing Time 0.027 seconds

An Operation Methed for Longitudinal Flow Ventilation System in a Road Tunnel (도로터널에서 종류식 환기 시설의 운전 방안)

  • Kim, T.H.;Hwang, I.J.;Hong, D.H.;Chung, J.S.;Chung, J.K.
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.87-92
    • /
    • 2001
  • In automobile highway tunnels, in order to maintain a suitable environment for drivers and traffic, visibility in the tunnel must be maintained, and the concentrations of poisonous substances including carbon monoxide must be kept at or below allowable levels. For this reason, in long tunnels and tunnels with heavy traffic, ventilation facilities are installed. When the ventilation facilities are run at full capacity, the environment in the tunnel is obviously adequately maintained, but this consumes a great deal of electric power. Consequently, a central problem in highway tunnel ventilation control systems is to keep the pollution concentration at or below the allowable level, and thus provide a safe environment for traffic, while consuming as little electricity as possible. This paper introduces an operation method of longitudinal flow ventilation systems with jet-fan, dust collector and vertical ducts.

  • PDF

A Study on the Sustainability of Compact Cities in Korea

  • Sun-Ju, KIM
    • The Journal of Economics, Marketing and Management
    • /
    • v.11 no.2
    • /
    • pp.13-22
    • /
    • 2023
  • Purpose: The purpose of this study is to examine the policy implications of establishing a compact city in Seoul, analyzing whether it is an appropriate and efficient eco-friendly housing supply alternative. Research design, data, and methodology: The analysis criteria include efficiency, safety, and comfort, with efficiency encompassing economic, energy, and public transport links' efficiency. Safety and comfort are aspects of eco-friendliness, housing safety, and improvement in living environments. Results: In terms of economic efficiency, compact cities are a less expensive option than purchasing land for housing construction. To increase energy efficiency, we plan to adopt eco-friendly energy sources. Transportation efficiency is high in locations near public transport stations. To enhance safety and comfort, we intend to create large-scale parks and forests in Seoul. To ensure residential safety, measures will be taken to reduce road vibration, vehicle noise, and scattering dust. Conclusions: Selecting an appropriate location that provides convenient public transportation is essential for creating a compact city for housing in a large city. Combining a compact and smart city is necessary, and implementing smart technologies is needed to prevent dust, noise, and vibrations, which are undesirable in a residential environment.

A Study on the Field Cutting Performance Analysis of Eco-friendly Road Cutter (친환경 도로절단기의 현장 절단성능 분석에 관한 연구)

  • Kim, Kyonghoon;Jun, Younghun;Kim, Kyoontai
    • Korean Journal of Construction Engineering and Management
    • /
    • v.21 no.4
    • /
    • pp.12-20
    • /
    • 2020
  • The demand for maintenance of underground facilities buried beneath the road continues to increase significantly, due to environmental problems caused by excessive noise and dust and complaints from urban residents, the demand for eco-friendly and low-noise road cutters is increasing. Therefore, we analyzed the cutting performance of low noise cutter and eco-friendly cutter and reviewed the improvement. Based on the field construction cases, problems and improvements were obtained according to the cutting machine working procedure. The productivity for cutting operations of eco-friendly cutters (36.0 seconds/m) was somewhat improved compared to the low noise cutters (37.6 seconds/m). However defects occurred in some sections and improvement was required.

Contamination Characteristics of Heavy Metals in Indoor, Outdoor and Playground of Schools in the Gochang-Gun, Chonbuk Province of South Korea (전북 고창지역 학교 실내외 환경의 중금속 오염 특성)

  • Kim, Yong-Hwan;Chung, Duk-Ho;Cho, Kyu-Seong
    • Journal of the Korean earth science society
    • /
    • v.27 no.1
    • /
    • pp.73-82
    • /
    • 2006
  • Dust samples were collected from 10 middle and high schools in the Gochang-Gun, Korea. Heavy metal concentrations were determined for the dry-deposited dusts from indoor and outdoor of classroom and playground of each sampling site. Concentrations of Cd, Cu, Pb and Zn in indoor's dusts were highly concentrated. Also concentrations of Cu, Ni, Pb and Zn in outdoor's dusts were highly concentrated. Concentrations of Cd, Cu and Zn in the dusts were much higher than the world average contents in soil and environmental orientation value. These levels are similar to those of the dust samples at middle schools and high schools located in Jeonju-city, Korea. Compared with concentrations of heavy metals in soils and dusts in Korea, the environment of indoor and outdoor of classroom is highly concentrated except for Cu, Zn. The concentrations of playground is less than that of residential dust and main road dust and playground in Jeonju-city. Playground dusts in 1 school exhibited the enhanced heavy metal pollution with a pollution index (Kloke, 1979) greater than 1.0, but indoor and outdoor dusts in 7 schools exhibited the enhanced heavy metal pollution with a pollution index (by Kloke) yester than 1.0.

Characteristics for Heavy Metal Pollution in Road Dust from Daebul Industrial Complex: Classification by Particle Size and Magnetic Separation (대불산업단지 도로먼지 내 중금속류 오염 특성: 입도와 자성에 따른 구분)

  • Jeong, Hyeryeong;Choi, Jin Young;Ra, Kongtae
    • Journal of Environmental Impact Assessment
    • /
    • v.29 no.4
    • /
    • pp.252-271
    • /
    • 2020
  • In this study, we investigated physical and chemical properties such as grain size, heavy metal pollution, magnetic properties, and their environmental impacts of road dusts (RD) collected from 14 sampling points in Daebul industrial Complex. Heavy metal concentrations in RD were in the order of Fe>Zn>Cu>Pb>Cr>Ni>As>Cd>Hg, and this pollution pattern was related to major industries and traffic activities in this area. The results of the correlation analysis between heavy metal elements and particle size in RD showed that Fe and all of analyzed heavy metals had a significant correlation with each other and metal concentrations had a significantly negative correlation (p<0.05). However, due to the input of large metal particles some heavy metal concentrations in the particle fraction of >1000 ㎛ were highest. Pollution load per unit area of this fraction was the highest among the grain size fractions. Cr, Ni, Cu, Zn, Cd, Pb levels in RD decreased and the levels of Cr, Ni, Cu, Zn, Cd, and Pb were reduced to 85 (As) -22 (Ni)% of the whole after removal of MFs fraction from RD. The mean heavy metal levels in the study area did not exceed the soil contamination guide value of Korea, indicating that heavy metal levels in RD were not a concern. However, at some sampling points, Zn concentrations were exceeded the soil contamination guide value for the 3rd areas of Korea and this result indicated that further studies of the impact of RD on the surrounding environment through re-suspension or non-point pollution, and of effective management methods are required.

Development of a Pavement Cutter for Eco-friendly Road Excavation Construction (친환경 도로굴착 시공을 위한 도로절단기 개발)

  • Kim, Kyoontai
    • Korean Journal of Construction Engineering and Management
    • /
    • v.23 no.6
    • /
    • pp.111-118
    • /
    • 2022
  • Recently, as underground facilities buried under roads in Korea are aging, the amount of underground facility maintenance work is rapidly increasing. For the maintenance and management of such underground facilities, the cutting work of the road pavement should be preceded. However, the conventional road pavement cutters used in Korea are not eco-friendly, and the reality is that they generate a lot of noise and cutting sludge (scattering dust). Therefore, in this study, the concept of the cutting sludge recovery device was derived, and an eco-friendly pavement cutter including this function was designed and manufactured. The developed equipment took about 20 to 30 seconds to cut 1m to a depth of 100 to 150mm. Also, the sludge suction performance was good in most sections, and the noise level of the equipment briefly measured at a distance of 2m was 82.7dB on average. However, due to the limitation that the developed equipment was at the level of the first prototype, the driving stability was somewhat low, and equipment abnormalities such as engine shutdown and sludge recovery performance decreased in some cases. The cutting performance and sludge recovery function will be more stable through tuning and improvement of the developed prototype in the future. In addition, we plan to quantitatively compare and analyze productivity by applying the improved prototype to actual field conditions.

Source Identification and Estimation of Source Apportionment for Ambient PM10 in Seoul, Korea

  • Yi, Seung-Muk;Hwang, InJo
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.3
    • /
    • pp.115-125
    • /
    • 2014
  • In this study, particle composition data for $PM_{10}$ samples were collected every 3 days at Seoul, Korea from August 2006 to November 2007, and were analyzed to provide source identification and apportionment. A total of 164 samples were collected and 21 species (15 inorganic species, 4 ionic species, OC, and EC) were analyzed by particle-induced x-ray emission, ion chromatography, and thermal optical transmittance methods. Positive matrix factorization (PMF) was used to develop source profiles and to estimate their mass contributions. The PMF modeling identified nine sources and the average mass was apportioned to secondary nitrate (9.3%), motor vehicle (16.6%), road salt (5.8%), industry (4.9%), airborne soil (17.2 %), aged sea salt (6.2%), field burning (6.0%), secondary sulfate (16.2%), and road dust (17.7%), respectively. The nonparametric regression (NPR) analysis was used to help identify local source in the vicinity of the sampling area. These results suggest the possible strategy to maintain and manage the ambient air quality of Seoul.

A Proposal for the Upgrade of the Current Operating System of the Seoul's Atmospheric Monitoring Network Based on Statistical Analysis (서울시 대기 측정소간 상관관계를 감안한 측정소의 운용 방향 개선을 위한 제언)

  • Bae, Min Suk;Jung, Chang Hoon;Ghim, Young Sung;Kim, Ki Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.4
    • /
    • pp.447-458
    • /
    • 2013
  • The present operating system for the atmospheric monitoring network in the city of Seoul, Korea, has been established since the late 90s by the Korean Ministry of Environment (KMOE). In this research, it was evaluated by the multi-statistical approaches through combinations of time series analysis, correlation matrix, and multiple cluster analysis. Finally, road traffic including resuspended materials can be one of the main sources of particulate matter in the atmosphere. Based on its importance, it will be significant challenges in quantitative evaluation of its contribution to airborne concentrations. The future directions for their amendments such as a new management plan for the source of road dust (including car emissions) were devised and proposed based on the statistical judgements derived in this research.

An Analysis of the Effect of Reducing Temperature and Fine Dust in the Roadside Tree Planting Scenario (가로수 식재 시나리오에 따른 기온 및 미세먼지 저감 효과 분석)

  • Jeong-Hee EUM;Jin-Kyu MIN;Ju-Hyun PARK;Jeong-Min SON;Hong-Duck SOU;Jeong-Hak OH
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.26 no.2
    • /
    • pp.68-81
    • /
    • 2023
  • This study aims to establish a scenario based on the spacing and arrangement of the roadside trees to reduce heat waves and fine dust in cities that occurred during the urbanization process and to quantitatively analyze the degree of reduction. The ENVI-met 5.0.2v model, a micro-climate simulation program, was used to analyze the degree of improvement in the thermal environment and fine dust according to the roadside tree scenario. As a result of temperature analysis according to street tree spacing, the narrower the distance between roadside trees, the lower the temperature during the day as the number of planted trees increased, and a similar pattern was shown regardless of the distance between roadside trees in the morning and evening. In the case of fine dust emitted from the road, the concentration of fine dust increased slightly due to the increase in roadside trees, but the concentration of sidewalks where people walk increased slightly or there was no difference because of blocking fine dust on trees. The temperature according to the arrangement of street trees tended to decrease as the number of planted trees increased as the arrangement increased. However, not only the amount of trees but also the crown projected area was judged to have a significant impact on the temperature reduction because the temperature reduction was greater in the scenario of planting the same amount of trees and widening the interval of arrangement. In terms of the arrangement, the fine dust concentration showed a difference from the results according to the interval, suggesting that the fine dust concentration may change depending on the relationship between the main wind direction and the tree planting direction. By quantitatively analyzing the degree of thermal environment and fine dust improvement caused by roadside trees, this study is expected to promote policies and projects to improve the roadside environment efficiently, such as a basic plan for roadside trees and a project for wind corridor forests.

Evaluation of Performance and Maintenance Cost for Roadside's Particulate Matter Reduction Devices Using Smart Green Infrastructure Technology (스마트 그린인프라 기술을 활용한 도로변 미세먼지 저감장치의 성능 및 유지·관리 비용 평가)

  • Song, Kyu-Sung;Seok, Young-Sun;Yim, Hyo-Sook;Chon, Jin-Hyung
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.25 no.4
    • /
    • pp.15-31
    • /
    • 2022
  • The Green Purification Unit System (GPUS) is a green infrastructure facility applicable to the roadside to reduce particulate matter from road traffic. This study introduces two types of GPUS (type1 and type2) and assesses the performance and maintenance costs of each of them. The GPUS's performance analysis used the data collected in November 2021 after the installation of the GPUS type1 and type2 at the study site in Suwon. The changes in the particulate matter concentration near the GPUS were measured. The maintenance cost of GPUS type1 and type2 was assessed by calculating the initial installation cost and the management and repair cost after installation. The results of the performance analysis showed that the GPUS type1, which was manufactured by combining plants and electric dust collectors, had a superior particulate matter reduction performance. In particular, type1 produced a greater effect of particulate matter reduction in the time with a high concentration (50㎍/m3 or higher) of particulate matter due to the operation of electric dust collectors. GPUS type2, which was designed in the form of a plant wall without applying an electric dust collector, showed lower reduction performance than type1 but showed sufficiently improved performance compared to the existing band green area. Meanwhile, the GPUS type1 had three times higher costs for the initial installation than GPUS type2. In terms of costs for managing and repairing, it was evaluated that type1 would be slightly more costly than type2. Finally, this study discussed the applicability of two types of GPUS based on the result of the analysis of their particulate matter performance and maintenance cost at the same time. Since GPUS type2 has a cheaper cost than type1, it could be more economical. However, in the area suffering a high concentration of particulate matter, GPUS type1 would be more effective than type2. Therefore, the choice of GPUS types should rely on the status of particulate matter concentration in the area where GPUS is being installed.