• Title/Summary/Keyword: Riverbank/Bed Filtration

Search Result 5, Processing Time 0.018 seconds

A KINETIC ANALYSIS OF ORGANIC RELEASE FROM THE AQUIFER SOIL IN RIVERBANK/BED FILTRATION

  • Ahn, Kyu-Hong;Moon, Hyung-Joon;Kim, Seung-Hyun
    • Environmental Engineering Research
    • /
    • v.10 no.4
    • /
    • pp.199-204
    • /
    • 2005
  • Experiments were performed to estimate the organic release from the aquifer soil in riverbank and/or riverbed filtration via a kinetic approach. Organic release was assumed as a reaction of first order regarding concentrations in both soil and water phases. The reaction rate constants were obtained by comparing the model predictions with the experimental data of organic release reaction and the equilibrium distribution of organic matter between water and soil phases. Results show that the organic release from the aquifer soil was not negligible under normal conditions in Korea reaching 4.7mg-COD/L-day. This indicates that manganese and iron start to be released from aquifer soil in the riverbank filtration in the middle reach of the Nakdong river if the travel time of the filtrate exceeds about 5 days. It was also seen that the COD of the soil organic matter was 0.89mg-COD/mg-OM and that 65% of the COD was BOD5.

An Experimental Study on the Behavior of Phenol, 1,4-dioxane and Diazinon along the Travel Distance in Riverbank Filtration (강변여과에서 여과거리에 따른 페놀, 1,4-다이옥산 그리고 다이아지논의 거동에 관한 실험연구)

  • Choi, Hong-Gyu;Jeong, Il-Hwa;Jung, Kwan-Sue;Lee, Young-Deuk;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.6
    • /
    • pp.436-441
    • /
    • 2013
  • An experiment using a 5 m-long sand column was performed to evaluate the resisting capability against micro-pollutants of the infiltration gallery, multi-purpose filtration pond and riverbank/bed filtration, of which the filtration distance is becoming increasingly shorter in Korea. Results suggested that the Korean riverbed sand contained significant amount of organics, resulting in a relatively vigorous adsorption of chloride ion on the sand surface. Results also indicated that while phenol was not detected in the column filtrate, both 1,4-dioxane and diazinon were exposed to adsorption by the sand as they moved through the column, decreasing their peak concentrations during the movement. It can be expected that the peak concentrations will diminish significantly in the practical scale due to its longer travel distance.

In Situ Iron-manganese Removal by an Oxygenated Water Injection-and-extraction Technique in a Riverbank Filtration System (산소수 주입-양수 기법을 통한 강변여과수 내 철/망간 저감 평가)

  • Yi, Myeong-Jae;Cha, Jang-Hwan;Jang, Ho-June;Ahn, Hyun-suk;Hahn, Chan;Kim, Yongsung
    • The Journal of Engineering Geology
    • /
    • v.25 no.3
    • /
    • pp.339-347
    • /
    • 2015
  • Riverbank filtration has been suggested as a cost-effective method for improving water quality. However, high concentrations of Fe2+ and Mn2+ cause problems for the use of water and the maintenance of facilities. We evaluated the effectiveness and efficiency of an Fe2+ and Mn2+ removal technique based on the in situ injection of highly oxygenated water at a site on the Anseong River, between Anseong City and Pyeongtaek City, Gyeonggi Province. The removal process consists of three steps: injection, resting, and extraction. Results show that the removal efficiency increases with repeated application of the process. The amount of Fe-reduced drinking water satisfying water regulations (limit, 0.3 mg/L Fe) obtained using oxygenated water injection was five times higher than the amount of injected oxygenated water. Levels of Mn2+ were also reduced following the injection of oxygenated water.

A Study on the Optimum Design of Horizontal Collectors in Floodplain Filtration (홍수터여과에서 집수관의 최적설계 연구)

  • Pi, Seong-Min;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.6
    • /
    • pp.430-437
    • /
    • 2012
  • In order to obtain information on the design parameters of the horizontal laterals in floodplain filtration, laboratory-scale sand-box experiments were performed where the head distributions on the laterals and the groundwater profiles were measured according to the change in parameters including lateral diameter, hydraulic conductivity of the sand, water level at the well and raw-water supply rate. Measured data were analyzed using a numerical code in order to identify the discharge intensity distribution along the laterals. It was observed from the result that the lowering of the water level at the well had minimal adverse effect on the performance of the floodplain filtration. Results also elucidated that the low conveyance of the laterals to transmit the filtrate was compensated and supplemented by a natural augmentation in horizontal conveyance through the aquifer when the raw-water supply rate exceeded the adequate recovery rate. With this mechanism, the water quality is expected to improve further since the travel distance through the aquifer is amplified. Based on these findings it can be suggested that the diameter of the lateral used in the floodplain filtration may be smaller than those in riverbank/bed filtration. It was also found that the ratio between the head loss occurring in a lateral and the total head loss in the floodplain filtration was proportional to the exit velocities of the laterals, which may be used to design and/or evaluate the lateral in floodplain filtration.

An Experimental Study on the Performance of Multi-Diameter Lateral for Riverbed Filtration (하상여과용 다직경 수평집수관의 효능에 대한 실험연구)

  • Bae, Gha-Ram;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.5
    • /
    • pp.359-364
    • /
    • 2012
  • In order to prevent the decrease in well efficiencies due to friction in the axial flow in long, large-diameter laterals, a multi-diameter lateral was devised and tested through lab-scale sand-box experiments to assess its performance. In the experiment, three different production rates were applied over the multi-diameter and the three single-diameter laterals to obtain the hydraulic head distributions for each, which was used to assess the performance of the laterals. Results elucidated that the multi-diameter lateral reduced the material cost by more than a third, in comparison to the single-diameter lateral, while maintaining the production rate at higher than 93%, proving its superiority. Furthermore, results indicated that exit velocities exceeding 0.8 m/sec in horizontal wells tended to distort the hydraulic head distribution near the exit, providing evidence of its inefficiency.