• 제목/요약/키워드: River water intake

검색결과 108건 처리시간 0.026초

관개용수 공급체계 변경을 통한 하천의 수질개선 (Water Quality Improvement in the River through Reformation of Irrigation Water Supply Systems)

  • 이광야;김해도;이종남;박종훈
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.540-545
    • /
    • 2006
  • The objective of the study is to assess the water quality improvement resulted from the rearrangement of the irrigation water supply systems at Mankyeong River and Ansung Chun basin. There is a mixed type of watershed composed of urban and rural areas in the region. The water intake facilities for agricultural use such as reservoir, weir and pumping station are generally located at upstream river where the water quality maintains relatively clean. However, this study focuses on moving the water intake to downstream and rearranging the irrigation water supply system, then investigating how effective they are for water quality improvement in the river. When the water intake is moved downstream, the stream flow is increased as much as the amount of irrigation water that is to be taken upstream. The augmented flow which is frequently referred to as environmental flow can function as dilution water for improving the quality of polluted water that is originated from the wastewater in tributaries.

  • PDF

국내 복류수 및 강변여과수 취수시설의 오염물질 제거특성에 관한 연구 (A study on pollutants removal characteristics of domestic riverbed filtration and riverbank filtration intake facilities)

  • 정찬우;이선익;신성우;송창현;조부근;최재원
    • 상하수도학회지
    • /
    • 제37권5호
    • /
    • pp.281-288
    • /
    • 2023
  • This study was performed to evaluate the pollutants removal characteristics of two types of RBFs(Riverbank filtration, Riverbed filtration) intake facilities installed in Nakdong River and in Hwang River respectively. The capacity of each RBF is 45,000 m3/d for riverbank filtration intake facility and 3,500 m3/d for riverbed filtration intake facility. According to data collected in the riverbank filtration site, removal rate of each pollutant was about BOD(Biochemical Oxygen Demand) 52%, TOC(Total Organic Carbon) 57%, SS(Suspended Solids) 44%, Total coliforms 99% correspondingly. Furthermore, Microcystins(-LR,-YR,-RR) were not found in riverbank filtered water compared to surface water in Nakdong River. DOC(Dissolved Organic Carbon) and Humics which are precursors of disinfection byproduct were also reported to be removed about 59% for DOC, 65% for Humics. Based on data analysis in riverbed filtration site in Hwang River, removal rate of each contaminant reaches to BOD 33.3%, TOC 38.5%, SS 38.9%, DOC 22.2%, UV254 21.2%, Total coliforms 73.8% respectively. Additionally, microplastics were also inspected that there was no obvious removal rate in riverbed filtered water compared to surface water in Hwang River.

수도권 팔당취수장 원수 이용 온도차에너지 부존량 조사 (Evaluation of Water Temperature Difference Energy of the Raw Water from Paldang Water Intake Station)

  • 조용;박진훈;김영준;박태진
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.170.2-170.2
    • /
    • 2010
  • The amount of the heating and cooling energy of water source heat pump using the raw water from the Paldang water intake station is investigated in the study. The Han river water is conveyed in the large-size shallowly buried pipe. Averaged water temperature at the position, 27 km from the Paldang water intake station, is increased by $1.11^{\circ}C$ due to the geothermal energy transfer under the ground, therefore the raw water has more thermal energy than the river water. To estimate of the thermal energy for the raw water, it is assumed that the water source heat pump is used for the heating and cooling ventilation. When $5.0^{\circ}C$ temperature difference energy of the raw water is used in the heat pump system all the year except for the January and February in which $3.0^{\circ}C$ temperature difference energy is used. It is predicted that total 5,766.3 Tcal could be used in the metropolitan area a year, which is about 3.0% of the river water unutilized energy resources.

  • PDF

3차원 수리모델을 이용한 한강 상수원구간 지류영향 분석 및 수질오염사고 시나리오 모의 (Impact Analysis of Tributaries and Simulation of Water Pollution Accident Scenarios in the Water Source Section of Han River Using 3-D Hydrodynamic Model)

  • 김은정;박창민;나미정;박현;김복순
    • 한국물환경학회지
    • /
    • 제34권4호
    • /
    • pp.363-374
    • /
    • 2018
  • The Han River serves as an important water resource for the city of Seoul, Korea and in the neighboring metropolitan areas. From the Paldang dam to the Jamsil submerged weir, the 4 water intake stations that are located for the Seoul metropolitan population were under review in this study. Therefore the water quality management in this section is very important to monitor, analyze and review to rule out any safety concerns. In this study, a 3-D hydrodynamic model, EFDC (Environmental Fluid Dynamics Code), was applied to the downstream of the Paldang Dam in the Han River, which is about 23 km in length, to determine issues related to water resource management. The 3-D grid was composed of 2,168 horizontal grids and three vertical layers. In this case, the hydrodynamic model was calibrated and verified with an observed average daily water surface elevation, water temperature and flow rate data for 3 years (2013~2015). The developed EFDC model proved to reproduce the hydrodynamics of the Han River well. The composition ratios of the noted incoming flows at the monitored intake stations for 3 years and their flow patterns in the river were analyzed using the validated model. It was found that the flow of the Wangsuk Stream depended on the Paldnag dam discharge, and it was noted that the composition ratios of the stream at the intake stations changed accordingly. In a word, the Wangsuk Stream moved mainly along the right bank of the Han River under the condition of a normal dam flow. As can be seen, when the dam discharge rate was low, the incidence of lateral mixing was often seen. The scenario analyses were also conducted to predict the transport of conservative pollutants as in the case of a chemical spill accident. Generally speaking, when scenarios were applied, the arrival time and concentration of pollutants at each intake station was thus predicted.

Sediment Control at Water Intake Structures in a River

  • Son, Kwang-Ik;Lee, Jae-Joon;Han, Kun-Yeon;Lee, Eul-Rae
    • Korean Journal of Hydrosciences
    • /
    • 제10권
    • /
    • pp.73-83
    • /
    • 1999
  • The intake towers of Buyeo W.T.P. in Keum river have being suffered from the sedimentation problems since the beginning of the operation. Impellers of the intake pumps have to the frequently changed due to the serious surface erosion. Thousands tons of sands are entrapped in the intake towers and equalization chambers of W.T.P. every year. Site surveying and numerical analysis were carried out to suggest an appropriate solution by understanding the general sedimentation regime of Keum river and causes of the sedimentation in the intake towers. Origin of the sediment could be found by the desk and site inspections. The validity of the used numerical models was examined by comparisons between the calculated bydraulic values and the measured ones during the specific periods. The design flow rate for the prediction of the future sedimentation regime of the rever was studied. The efficiency of the sediment control measures was also examined with the verified numerical models. Finally, it was found that the best solution could be a combination of three sediment control measures; increase the clearance between river bed and inlet, construct jetties at 2 kilometers upstream from the intake towers, and put vanes at the right side of the intake towers.

  • PDF

낙동강 달서지구 강변 여과수 취수에 관한 예비 연구

  • 김형수;박승기;정찬;백건하;원이정;신흥섭
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 총회 및 춘계학술발표회
    • /
    • pp.93-97
    • /
    • 2002
  • This research introduces some preliminary results of bank filtering intake method adopted in Dalseo area, Nakdong River. This intake method has been planned to supply water resources of 41,000 ㎥/day to Goryeong-Gun and Seongju-Gun in 2016. It is believed that the bank filtering intake method can afford to supply 41,000 ㎥/day amount of water resources and that the raw water quality using the method has more advantages in water treatment than direct surface water intake. Even though the safety yield about individual vertical well is roughly estimated to about 2,000 ㎥/day, it is desirable to decrease the safety yield to about 1,000 ㎥/day in the consideration of long term and simultaneous well pumpings and other unknown factors. Ongoing study will give basic data and new techniques to solve the problems appearing in application of bank filtering method as well.

  • PDF

Practical Experiences with Corrosion Protection of Water Intake Gates in Mekong River

  • Phong, Truong Hong;Tru, Nguyen Nhi;Han, Le Quang
    • Corrosion Science and Technology
    • /
    • 제7권6호
    • /
    • pp.328-331
    • /
    • 2008
  • Corrosion behaviour of water intake gate steel structures with different protective measures was investigated. Five material alternatives were taken for investigation, including: imported and recycled stainless steel, carbon steel with hot zinc spraying, painting and composite coatings. Results of corrosion rate for carbon steel, SUS 304, hot zinc spray coats in three water systems of Mekong river basin (saline, blackish and fresh) were also presented. Corrosion rate of carbon steel decreased with decreasing salinity in the investigated water environments. Meanwhile, these values for zinc coated steel, behaved by another way. Environmental data for these systems were filed and discussed in relation with corrosion characteristics. Method of Life Cycle Assessment (LCA) was applied in materials selection for water intake gate construction. From point of Life Cycle Cost (LCA) the following ranking was obtained: Zinc sprayed steel < Recycled stainless steel < Composite coated steel < Painting steel < SUS 304 From investigated results, hot zinc spray coating has been applied as protective measure for steel structures of water intake systems in Mekong river basin.

2차원 이송-확산모형을 이용한 취수장 인근에서의 오염물질의 혼합거동 모의 (Simulation of Pollutants Transport using 2-D Advection-Dispersion Model near Intake Station)

  • 김재동;김영도;류시완;서일원
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.791-794
    • /
    • 2008
  • 하천에 위치하는 취수장의 수질관리에 있어서 오염물질의 이송-확산은 주요 관심사다. 오염물 이송에 관한 연구를 위해서는 하천의 사행에 따른 영향과 지류의 유입에 따른 혼합에 대해서 분석이 수행되어져야 한다. 본 연구의 목적은 낙동강 하류에 위치한 물금취수장 부근에서의 오염물의 혼합거동을 모의하고자 하였다. 물금취수장은 부산광역시의 음용수로써 이용되고 있으며, 물금취수장 인근에서의 흐름은 인근의 지천의 유입과 본류 유량, 그리고 하류단에 위치한 하구둑 수문개폐 여부의 영향을 받는다. 수문은 10개의 수문으로 구성되며, 평상시에는 조위에 따라서 보조수문을 개방하고 유량이 증가할 때 주수문을 함께 개방한다. 취수장 맞은편인 본류의 우안에는 지류인 대포천이 위치하는데 지류에서 발생한 오염물질은 취수장 인근에 흐름형태에 따라 취수구로 유입되기도 한다. 본 연구에서는 2차원 수치해석 결과를 바탕으로 오염사고에 대비한 적절한 취수장 운영방안을 제시하고자 하였다.

  • PDF

전라북도 물이용 체계 및 과제(만경강과 동진강 중심으로) (Status of Water Infrastructure and Future Tasks in Jeollabuk-do Province(Focussed on the Mangyeong River and Dongjin River))

  • 김보국
    • 상하수도학회지
    • /
    • 제36권5호
    • /
    • pp.289-296
    • /
    • 2022
  • Mangyeong River and Dongjin River are highly dependent on external regions for domestic and agricultural water, and the agricultural water supply and use system of those rivers are very complicated. For smooth water supply, rivers are used as a supply system. Of the total river water use permits (as of 2019), agricultural water accounts for 97.5%, 80.4% in Mangyeong River and Dongjin River, respectively. The excessive intake of river water as agricultural purpose is causing the stream to dry out and to deteriorate the ecological health of the river. It is necessary to minimize the water use system that takes in and utilizes river water. In both rivers, the flow rate of agricultural drainage and the load of major water quality items that flowing into the main stream are similar to or higher than those of the major tributaries, indicating that management is necessary to improve the water quality of the river. It is necessary to understand the effect of agricultural drainage on river water quality by establishing a continuous monitoring system for the form of agricultural drainage.

2차원 이송-확산 모형을 이용한 취수장 유입 수질 예측 (Water Quality Modeling for Intake Station by 2-dimensional Advection-Dispersion Model)

  • 김재동;김지훈;김영도;송창근;서일원
    • 상하수도학회지
    • /
    • 제25권5호
    • /
    • pp.667-679
    • /
    • 2011
  • In this study, the influences of pollutant from Dae-po Stream and So-gam Stream located at the downstream of Nak-dong River on the water quality at Mul-geum water intake station were analyzed using RAMS model. Field measurements of velocity by ADCP, and water quality distribution of BOD and TP by water sampling were carried out to present the input and verification data for numerical simulations. The comparison between RAM2 and ADCP measurement, which aimed for the analysis of 2-D velocity distribution around Mul-geum water intake station showed that two results matched well along the spanwise direction. The prediction of pollutant concentration by RAM4 agreed fairly well with the measured data except for the points nearby right banks in the vicinity of tributary pollutant source. Flushing effect by the increase of mainstream discharge in Nak-dong River was analyzed to provide the damage mitigation in preparation for the accidental water pollution. With increasing mainstream discharge, high velocity and increased water quantity induced increasing dilution effect, thereby decreasing the inflow pollutant concentration rapidly.