• Title/Summary/Keyword: River Facility

Search Result 188, Processing Time 0.033 seconds

Unit Mass Estimation and Analysis from Fiber Dyeing and Finishing Facility Nearby Nakdong River Basin (낙동강수계에서 섬유염색 및 가공 업체에 대한 공정별 원단위산정 및 분석)

  • Gu, Jung-Eun;Nah, Dong-Hoon;Lee, Seung-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.9
    • /
    • pp.765-774
    • /
    • 2009
  • Fiber Dyeing and Finishing facility has been recognized as an important pollution source due to its consumption of large volumes of water and chemicals. Unit mass discharge for the conventional water quality parameters such as flowrate, SS, $BOD_5,\;COD_{Mn},\;COD_{Cr}$, TN, TP were estimated. To represent the respective industries, three companies were carefully selected based on its manufacturing goods, flowrate and location at various unit operations and processes. More than 90% of decrease in unit mass estimation between influent and effluent of BOD was observed. But the values themselves were similar to those of Fiber Manufacturing facility due to the high loadings of organic matter. Biodegradability of influent was almost three times higher than that of effluent. Unit mass discharge estimations of unit process (estimated in this study) based on space, products and raw material were similar to those of composite process (estimated by National Institute of Environmental Research), while big difference was observed in the other factors. Unit mass discharge factors calculated in this study can be used as the reference for the estimation of water pollution loading costs in Nakdong river basin. For the effective water pollution control and management, it is essential to characterize the various types of water quality parameters from the effluents of individual industrial wastewater treatment plants.

The Development Method of IFC Extension Elements using Work Breakdown Structure in River Fields (작업분류체계를 활용한 하천분야 IFC 확장 개발방안)

  • Won, Jisun;Shin, Jaeyoung;Moon, Hyoun-Seok;Ju, Ki-Beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.77-84
    • /
    • 2018
  • As the application of BIM (Building Information Modeling) to the civil sector has become practical, and mandatory for road projects, the standardization, development of systems, etc. for the application and operation of BIM are required. In particular, it is important to develop BIM data standards for producing, sharing and managing the lifecycle data of civil facilities because they are commonly national public facilities. The BIM data standards have been developed by utilizing or extending IFC (Industry Foundation Classes), which is an international standard, but schema extensions of river facilities has not been developed thus far. This study proposes an approach to an IFC extension for river facilities using the WBS (Work Breakdown Structure) as a fundamental study for IFC-based schema extension in the river field. For this purpose, the research was carried out as follows. First, the IFC extension development method was selected to represent the river facilities by analyzing the existing IFC structure and previous research cases for the IFC extension. Second, extended elements of the river facilities were identified through an analysis of the WBS and classified according to the high-level structure of the IFC schema. Third, the classified elements were arranged based on the IFC hierarchy and the IFC schema extension for river facilities was established. Based on the suggested extension method of IFC schema, this study developed the schema by defining the element components and parts of river facilities, such as distribution flow elements and deriving their detailed types and properties.

The Possibility of Flooding and Human Activities of Gyeongju Area in Ancint Times (고대 경주 지역의 홍수 가능성과 인간 활동)

  • Hwang, Sang-Ill
    • Journal of the Korean Geographical Society
    • /
    • v.42 no.6
    • /
    • pp.879-897
    • /
    • 2007
  • The Royal District in Gyeungju-city was placed in lower surface of alluvial fan that was formed during the Last Glacial Age. During the Holocene, Bukcheon-river was reached in the dynamic equilibrium status and the form of river channel was similar or same to the present. The cases of dying people and carrying houses away by flood for ancient history in Gyeongju were six times, in 131, 160, 350, 496, 657 and 703. Like this big flood was happened at interval of $150{\sim}200$years. A period of big flood appearance in Bukcheon-river was extremely long. Therefore the people who had lived in Gyeongju for ancient history perceived that most part of riverbed of Bukcheon-river was a safety place from flood damages. Not only private houses. In east part of Bunhwangsa temple, that is, west side of Bukcheon-river where the river energy is maximum, a pillow block was built to prevent a lateral erosion but any artificial riverbank was not. In spite of high flood possibility in Bukcheon-river, there was no facility to prevent floods in this section. Also, deposits of flood are not identified. This point is very suggestive that Bukcheon-river did not flood for ancient history.

Effects of Pipe Network Materials and Distance on Unused Energy Source System Performance for Large-scale Horticulture Facilities (배관 재질 및 길이에 따른 대규모 시설원예단지용 미활용 에너지 시스템의 성능 평가)

  • Lee, Jae-Ho;Yoon, Yeo-Beom;Hyun, In-Tak;Lee, Kwang Ho
    • KIEAE Journal
    • /
    • v.14 no.4
    • /
    • pp.119-125
    • /
    • 2014
  • This study investigated the effects of pipe network materials and distance on system performance utilizing unused energy sources in large-scale horticulture facility. For this, the modeling was performed with a 100 m long and 100 m wide rectangular shaped glass house having an area of 1ha ($10,000m^2$) using EnergyPlus software. The heat sources considered were air source, geothermal heat, power plant waste heat, sea water heat, and river water. The temperature variation of the fluid with regard to pipe material and distance from the heat source and the resultant heat pump electricity consumptions were calculated. It turned out that the fluid temperature reaching the heat pump increased as the distance from the heat source increased in case of sea water and river water, which have higher temperatures than the surrounding soil, improving the heat pump efficiency. It was vice versa in case of the power plant waste heat. In addition, pipe material of PVC showed the smallest effect on the system performance variation due to the lowest thermal conductivity, compared to PB and HDPE.

Comparison of Alternatives of Water-Friendly Facilities in an Industrial Complex (산업단지내 친수시설 대안의 비교)

  • Chung, Sang-Ok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1570-1576
    • /
    • 2008
  • Construction of the water-friendly facilities in the apartment complex and industrial complex became popular these days. In planning water-friendly facilities, kinds, layouts, water sources, water quality and water circulation system should be studies. In this study, several alternatives for a regional industrial complex project were studies and a most reasonal alternative was selected. A main canal across the central part of the complex is the principle facility with ponds and parks. The water source alternatives were a river nearby, a reservoir, ground water and urban water supply system. For each system, water quantity and quality, circulation system, permit and maintenance were compared. The facilities should be constructed with natural material such as rock and gravel. Average depth and velocity in the canal should be 10 cm and 0.15 m/s, respectively in order to people can feel the water flow in the canal. Based on the comparison, it is found that using the ground water, and water circulation system with storage tanks at the upper and lower ends of the canal system is the best alternative.

  • PDF

A Comparative Study on Direct Instrument Methods in Open Channel for Measuring River Water Usage (하천수 사용량 계측을 위한 개수로에서의 직접 계측방법 비교 연구)

  • Baek, Jongseok;Kim, Chiyoung;Lee, Kisung;Kang, Hyunwoong;Song, Jaehyun
    • Journal of Korean Society of Disaster and Security
    • /
    • v.13 no.4
    • /
    • pp.65-74
    • /
    • 2020
  • Continuous and accurate instrument of river water usage is needed for sustainable river water management. Although the instrument methods applicable to each point of use of river water are different, more precise direct instrument methods are required at the point of major open channel. Users of river water should select appropriate direct instrument methods to measure usage, but there is a lack of standards and verification research. In this study, the H-Q rating curve method, ultrasonic method, and microwave method were applied directly to the test basin in the upper basin of Mangyeong river, and the accuracy of measurement data was evaluated by comparing absolute error between discharge data calculated by instrument method. When comparing the calculated discharge of point units, the ultrasonic method showed the best results of the actual measurement. Through continuous instrument, the sum of the daily and monthly units was compared, and the ultrasonic and microwave methods were shown to be highly accurate. Based on the results of this study, it is hoped that the appropriate direct measurement method can be selected according to the importance of the river water use facility, considering that the ultrasonic method and the microwave method are relatively costly compared to the water level-flow relationship method.

Analysis of Water Quality Components and Antibiotics in the Final Effluent of Wastewater Treatment Facilities in the Nakdong River Basin (낙동강 유역에 위치한 폐수처리시설 최종방류수의 수질과 항생물질 분석)

  • Park, Kyeong-deok;Kang, Dong-hwan;Jo, Won Gi;Yu, Hun Sun;Yoon, Yeon Su;Kim, Byung-Woo
    • Journal of Environmental Science International
    • /
    • v.29 no.8
    • /
    • pp.857-870
    • /
    • 2020
  • In this study, the antibiotic components in the final effluent from the 12 wastewater treatment facilities located in the Nakdong River basin were investigated, and the correlation between organic matters, nutrients and antibiotics was analyzed. In the final effluent of the wastewater treatment facilities, three sulfonamides antibiotics (sulfamethazine, sulfathiazole, sulfachlorpyridazine) and tetracyclines antibiotics (oxytetracycline, doxycycline) were detected. Sulfamethazine were detected at all points and ranged from 10.398 to 278.784 ng/L. Sulfathiazole were detected at 6 points (Andong, Gumi, Hapcheon, Miryang, Uiryeong, Haman), and ranged from 23.773 to 144.468 ng/L. The correlation coefficients between sulfathiazole and TSS, COD, TOC, NH3-N, NO2-N, and T-N components were high in the range of 0.73 to 0.92. The correlation coefficient between sulfamethazine and T-N was 0.48, and the correlation with the rest of the water quality components was low. The correlation coefficient between sulfamethazine and sulfathiazole was 0.78. Through this study, it was confirmed that the concentration of sulfonamides antibiotics was higher than the concentration of tetracyclines antibiotics in the final effluent of 12 wastewater treatment facilities in the Nakdong River basin, and the concentration of sulfathiazole increased with organic matters and nutrients.

Site Suitability and Developable Amount Assessment for Riverbank Filtration in the Han River (I) (한강에서의 강변여과수 개발을 위한 적지선정 및 개발가능량 산정(I))

  • Lee, Sang-Il;Lee, Sang-Sin
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.8
    • /
    • pp.825-834
    • /
    • 2008
  • Riverbank filtration for water supply has been employed for about 150 years in developed countries. In Korea, the feasibility of riverbank filtration has been investigated since 1990's for large river basins, to find a solution to stably meet the ever-increasing demand for water. Recently, some cites in the Nak-dong River Basin have been supplying the water through riverbank filtration. This research studies the feasibility of riverbank filtration in Seoul. Analytic Hierarchy Process (AHP), which selects the most optimal alternative by hierarchically classifying various attributes and then quantifying the importance of each attribute, was applied to candidate locations for the selection of riverbank filtration site. The Kwangnaru district, which has advantages in water quality and close connectivity to the existing water purification facility, was selected as the most optimal site.

A Study on the Reduction of Total Phosphate of the Concerned Pollution Area in the Main Stream of Mangyeong River (만경강 본류 중 오염우심지역의 TP 저감방안 연구)

  • Jounghwa, Choi;Jaeog, Kwon;Miseon, Lee;Wook, Jang;Geunhwa, Choi;Eunhye, Ko;Seohyeon, Sim;Changwoo, Cho
    • Journal of Korean Society on Water Environment
    • /
    • v.38 no.6
    • /
    • pp.316-326
    • /
    • 2022
  • This study aimed to investigate the causes of the increasing Total Phosphate(TP) in the mainstream of Mangyeong river over the past 10 years, and suggested a reduction plan of about 3 points. First, the high TP concentration was continuously released in the discharge outlet of the Haepo bridge stormwater pipeline. The average TP concentration was 5.066 mg/L and values as high as 29.470 mg/L were measured. The highest pollution contribution rate to the Mangyeong river was more than 70 %. The cause of the pollution was expected to take place somewhere in Wanju Industrial Complex. Second, the average TP concentration of wastewater-treated effluent in the H factory was 0.405 mg/L. If a TP reduction facility is additionally installed in the H factory, it will help reduce TP uptake by Lake Saemangeum. Third, the TP concentration of untreated non-point source point flowing into the Samrae stream was very high with an average of 2.828 mg/L. Also, the pollution contribution rate of Samraecheon 2 to Mangyeong river was 21.8 % on average and up to 58 %. The pollution contribution rate was also high during the agricultural season and the winter, during which the flow rate is decreased. Investigation of these three points may be continuously needed, and analysis results and policy proposals presented to Jeollabukdo and Wanjugun to manage pollution sources.

The Prototype and Structure of the Water Supply and Drainage System of the Wolji Pond During the Unified Silla Period (통일신라시대 월지(月池) 입·출수 체계의 원형과 구조)

  • Kim, Hyung-suk;Sim, Woo-kyung
    • Korean Journal of Heritage: History & Science
    • /
    • v.52 no.4
    • /
    • pp.124-141
    • /
    • 2019
  • This research explored the relationship between the water quality issue of Wolji Pond (Anapji Pond) with the maintenance of the channel flow circulation system. The water supply and drainage system closely related to the circulation system of pond has been reviewed, rather than the existing water supply and drainage system that has been analyzed in previous studies. As a result of reviewing the water supply system, it has been learned that the water supply system on the southeastern shore of Wolji Pond, being the current water supply hole, has been connected to the east side garden facility (landscaping stone, curved waterway, storage facility of water) between the north and south fence and the waterway. This separate facility group seems to have been a subject of the investigation of the eastern side of Wolji Pond, with the landscaping stones having been identified in the 1920's survey drawings. The water supply facility on the southeastern shore, being the suspected water supply hole, seems to have some connection with the granite waterway remaining on the building site of Imhaejeon (臨海殿) on the southern side of Wolji Pond. It is inferred that it provides clean water, seeing that the slope towards the southwestern shore of Wolji Pond becomes lower, the landscaping stones have been placed in the filter area, and it is present in the 1920's survey drawings and the water supply hole survey drawing of 1975. The water drainage facility on the northern shore is composed of five stages. The functions of the wooden waterway and the rectangular stone water catchment facility seem not to be only for the water drainage of Wolji Pond. In light of the points that there are wood plugs in the wooden waterway and that there is a water catchment facility in the final stage, it is judged that the water of Balcheon Stream (撥川) may be charged in reverse according to this setup. Namely, the water could enter and exit in either direction in the water drainage facility on the northern shore It also seems that the supply to the wooden waterway could be opened and shut through the water catchment facility of rectangular stone group as well. The water drainage facility on the western shore is very similar to the water drainage facility on the northern shore, so it is difficult to avoid the belief that it existed during the Silla Dynasty, or it has been produced by imitating the water drainage facility on the northern shore at some future point in time. It seems to have functioned as the water drainage facility for the supply of agricultural water during the Joseon Dynasty. The water supply and drainage facilities in Wolji Pond have been understood as a systematized distribution network that has been intertwined organically with the facility of Donggung Palace, which was the center of the Silla capital. Water has been supplied to each facility group, including Wolji Pond, through this structure; it includes the drainage system connecting to the Namcheon River (南川) through the Balcheon Stream, which was an important canal of the capital center.