• Title/Summary/Keyword: Ripple requirement

Search Result 25, Processing Time 0.023 seconds

DC-Link Voltage Ripple Analysis of Minimum Loss Discontinuous PWM Strategy in Two-Level Three-Phase Voltage Source Inverters (최소 손실 불연속 변조 기법에 따른 2레벨 3상 전압원 인버터의 직류단 전압 맥동 분석)

  • Lee, Junhyuk;Park, Jung-Wook
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.2
    • /
    • pp.120-126
    • /
    • 2021
  • DC-link capacitors are one of the main components in two-level three-phase voltage source inverters (VSIs); they provide the pulsating input current and stabilize the vacillating DC-link voltage. Ideally, the larger the capacitance of DC-link capacitors, the better the DC-link voltage stabilizes. However, high capacitance increases the cost and decreases the power density of VSI systems. Therefore, the capacitance should be chosen carefully on the basis of the DC-link voltage ripple requirement. However, the DC-link voltage ripple is dependent on the pulse-width modulation (PWM) strategy. This study especially presents a DC-link voltage ripple analysis when the minimum loss discontinuous PWM strategy is applied. Furthermore, an equation for the selection of the minimum capacitance of DC-link capacitors is proposed. Experimental results with R-L loads are also provided to verify the effectiveness of the presented analysis.

Multiple Output Charger based on the Novel Time Division Multiple Control Technique (새로운 시분할 다중 제어 기법에 기반한 다중 출력 충전기)

  • Tran, Van-Long;Choi, Woo-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.13-14
    • /
    • 2013
  • Multiple output converters (MOCs) are widely used for applications which require various kinds of the output voltages due to its advantages in cost, volume, and efficiency. However, most of the MOCs developed so far can regulate only one output tightly and require as many secondary windings in the transformer as the number of the outputs. In this paper, a novel Time Division Multiple Control (TDMC) method to regulate all the outputs in high precision is proposed and applied to the double ended forward converter for the multiple battery charger. Additional benefit of the proposed topology is to require only one secondary winding in the transformer for all the outputs. The proposed converter can charge two different kinds of batteries or same kind of batteries in different state of charges (SOCs) by CC/CV mode independently with the even degree of tight regulation, thereby satisfying the ripple requirements for each battery.

  • PDF

An Adaptive Operation Scheme of Switched Reluctance Motor (스위치드 릴럭턴스 전동기의 적응운전방식에 관한 연구)

  • Lee, Chee-Woo;Oh, Seok-Gyu;Lee, Ill-Chun;Hwang, Young-Moon
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.44-46
    • /
    • 1997
  • The intrinsic simplicity, ruggedness, and simple power electronic drive requirement of a switched reluctance motor (SRM) make it a viable use for many commercial adjustable speed applications. However, higher torque ripple is one of the few disadvantages of the SRM drives. This paper describes the robust control scheme that permits the phase torque flatted by adaptive reference model.

  • PDF

A Study on the Management and Application for Prevention Information Communication System (방재정보통신시스템 관리 운용 및 응용에 관한 연구)

  • Kang, Heau-Jo
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.6
    • /
    • pp.611-618
    • /
    • 2008
  • The development of information society together with information telecommunication's influence on the human society is a ripple effect and getting wider. Among those ripple effects the disaster prevention is in the public eye in the present day. On the way to the ubiquitous society the main techniques to be concerned in ubiquitous sensor networks are the field of damage of storm and flood, safety facilities, traffic safety, industrial safety, energy safety, fire fighting, specific safety of radioactivity escape incident, environmental pollution, sea pollution, mountain and forrest disaster so on. In this paper the USN technique based on the disaster prevention communication technology service and its requirement technology and application are studied.

  • PDF

Analysis and Design of a Single-Phase Tapped-Coupled-Inductor Boost DC-DC Converter

  • Gitau, Michael Njoroge;Mwaniki, Fredrick Mukundi;Hofsajer, Ivan W.
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.636-646
    • /
    • 2013
  • A single-phase tapped-inductor boost converter has been proposed previously. However, detailed characterization and performance analysis were not conducted. This paper presents a detailed characterization, performance analysis, and design expressions of a single-phase tapped-coupled-inductor boost converter. Expressions are derived for average and RMS input current as well as for RMS input and output capacitor current ripple. A systematic approach for sizing the tapped-coupled inductor, active switch, and output diode is presented; such approach has not been reported in related literature. This study reveals that sizing of the inductor has to be based on current ripple requirement, turns ratio, and load. Conditions that produce discontinuous inductor current are also discussed. Analysis of a non-ideal converter operating in continuous conduction mode is also conducted. The expression for the voltage ratio considering the coupling coefficient is derived. The suitability of the converter for high-voltage step-up applications is evaluated. Factors that affect the voltage boost ratio are also identified. The effects of duty ratio and load variation on the performance of the converter are also investigated. The theoretically derived characteristics are validated through simulations. Experimental results obtained at a low power level are included to validate the analytical and simulation results. A good agreement is observed among the analytical, simulation, and experimental results.

A Novel Direct Torque Control of Induction Motor

  • Park J. H.;Lee K. J.;Choi J. W.;Kim H. G.;Chun T. W.;Nho E. C.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.423-427
    • /
    • 2001
  • This paper describes a control scheme for direct torque and flux control of Induction machines using space vector modulation. The proposed predictive flux control scheme has directly calculated the reference voltage space vector based on Stator flux errors in order to control the torque and flux. This proposed control scheme has not the requirement of a separate current error, thereby improving transient performance and also has the advantage of less torque ripple in steady state with a fixed switching period. The effect of proposed method has been proven by simulations. It is concluded that the proposed control topology produces better results for steady state operation than the classical direct torque control.

  • PDF

A Novel Direct Torque Control of Induction Motor using stator flux (고정자 자속제어를 이용한 유도전동기의 새로운 직접 토크 제어)

  • Park Jun-Hyun;Jeong Jong-Jin;Choi Jong-Woo;Kim Heung-Geun
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.15-18
    • /
    • 2001
  • This paper describes a control scheme for direct torque and flux control of induction machines. The proposed predictive flux control scheme has directly calculated the reference voltage space vector based on flux errors in order to control the torque and flux. This proposed control scheme has not the requirement of a separate current regulator and proportional-integral (PI) control of the flux, torque, and/or current error, thereby improving transient performance and also has the advantage of less torque ripple in steady state with a fixed switching period. The effect of proposed method has been proven by simulations and experiments.

  • PDF

Variable Structure PWM Controller for Highly Efficient PV Inverters

  • Oh, Seong-Jin;SunWoo, Myoung-Ho
    • Journal of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.866-873
    • /
    • 2009
  • In general, the output voltage level of a PV array varies widely at various irradiances and temperatures. The MPP (Maximum Power Point) range of a medium- or high-power PV PCS is normally 450~830Vdc or 300~600Vdc. This means the PV PCS should operate in a wide range of modulation indexes. The PV PCS should satisfy the harmonic current requirement that the TDD (Total demand distortion) shall not exceed 5%. This paper proposes a new PWM control method for a medium- or high-power PV PCS which increases the efficiency of power conversion in all operation ranges with acceptable harmonic ripple currents. This paper compares and analyzes appropriate PWM schemes for the PV PCS in the view points of conversion efficiency and current harmonics.

The study of Direct Torque Controlled BLDC Motor Drive with Sinusoidal EMF (정현파 역기전력을 갖는 BLDC의 직접토크 제어에 관한 연구)

  • Kim J.S.;Kim C.U.;Cho S.E.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.1-5
    • /
    • 2004
  • This paper describe a control scheme for direct torque control of BLDC Motor. The proposed Luenberger Observer scheme calculate flux errors in order to control the torque and flux more correctly. This proposed control scheme has not the requirement of a separate current regulator and proportional-integral (PI) control of the flux and torque, there by improving transient performance and also has the advantage of less torque ripple in steady state with a fixed switching period. The effect of proposed method has been proven by simulations.

  • PDF

Reduction of Minimum Switching Duration in the Measurement of Three Phase Current with DC-Link Current Sensor (DC링크 전류센서를 이용한 삼상전류 측정 방식에서 최소 스위칭 시간의 단축)

  • 김경서
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.12
    • /
    • pp.649-654
    • /
    • 2003
  • The simplest method for measuring output currents of the three phase inverters is to measure them with three current sensors such as hall sensors. This method requires at least two current sensors, and these types of sensors are somewhat expensive. More economical method is measuring DC link current with a simple shunt resistor, then, reconstructing output current using the DC link current value and the switching status. However, in low speed region, the measurement becomes difficult and even impossible due to the requirement of minimum switching duration for A/D conversion. These problems can be overcome by limitation of switching duration. Limitation of switching, however, causes voltage and current distortion. Owing to compensation, distortion can be effectively suppressed. However these increase acoustic noise due to increment of current ripple. In this paper, a current measurement method is proposed, which can reduce minimum switching duration resulting in reduction of acoustic noise. The validity of proposed method is confirmed through experiment.