• Title/Summary/Keyword: Ripple line

Search Result 147, Processing Time 0.038 seconds

Implementation of BOOST Converter with Power Factor Correction(PFC) using a Single-phase On-line UPS (단상 On-line UPS를 이용하여 역율을 개선하는 BOOST 컨버터의 구현)

  • Han, Wan-Ok;Kim, Tae-Woong
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.4
    • /
    • pp.47-52
    • /
    • 1999
  • This paper proposed simplified method to complicated Power Stage with a new On-line UPS scheme by replacing essential battery-voltage booster with a dual-functional PFC. Direct Load Voltage (${V_o}$) can not be applied to high voltage switching converter due to ripple from traditional Power Factor Correction (PFC) but Boost Function of On-line UPS is united so that the cost of system design and development is inexpensive. Through varification of experimental result, proposed UPS scheme shows its performance, low cost and high power density.

  • PDF

Fabrication of high-temperature superconducting low-pass filter for broad-band harmonic rejection (광대역 고조파 제거를 위한 고온초전도 저역통과필터의 제작)

  • Han, Seok-Gil;Kang, Gwang-Yong;Ahn, Dal;Suh, Jun-Seok;Choi, Chun-Geun;Kim, Sang-Hyeon;Kwak, Min-Hwan
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.193-196
    • /
    • 2000
  • A new type low-pass filter design method based on a coupled line and transmission line theory is proposed to suppress harmonics by attenuation poles in the stop band. The design formula are derived using the equivalent circuit of a coupled transmission line. The new low-pass filter structure is shown to have attractive properties such as compact size, wide stop band range and low insertion loss. The seventh-order low-pass filter designed by present method has a cutoff frequency of 0.9 CHz with a 0.01 dB ripple level. The coupled line type low-pass filter with strip line configuration was fabricated by using a high-temperature superconducting (HTS : YBa$_2$Cu$_3$O$_{7-{\delta}}$ thin film on MgO(100) substrate. Since the HTS coupled tine type low-pass filter was proposed with five attenuation poles in stop band such as 1.8, 2.5, 4, 5.5, 6.2 GHz. The fabricated low-pass filter has improved the attenuation characteristics up to seven times of the cutoff frequency.

  • PDF

Fault Diagnosis Method of Voltage Sensor in 3-phase AC/DC PWM Converters

  • Kim, Hyung-Seop;Im, Won-Sang;Kim, Jang-Mok;Lee, Dong-Choon;Lee, Kyo-Beum
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.3
    • /
    • pp.384-390
    • /
    • 2012
  • This paper proposes a fault diagnosis method of the line-to-line voltage sensors in 3-phase AC/DC pulse width modulation (PWM) converters. The line-to-line voltage sensors are an essential device to obtain the information of the grid voltages for controlling the 3-phase AC/DC PWM converters. If the line-to-line voltage sensors are mismeasured by various faults, the voltage sensors can obtain wrong information of the grid voltage. It has an adverse effect on the control of the converter. Therefore, the converter causes the unbalance input AC current and the DC-link voltage ripple in the 3-phase AC/DC PWM converter. Hence, fast fault detection and fault tolerant control are needed. In this paper, the fault diagnosis method is proposed and verified through simulations and experiments.

A FAST REDUCTION METHOD OF SURVEY DATA IN RADIO ASTRONOMY

  • LEE YOUNGUNG
    • Journal of The Korean Astronomical Society
    • /
    • v.34 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • We present a fast reduction method of survey data obtained using a single-dish radio telescope. Along with a brief review of classical method, a new method of identification and elimination of negative and positive bad channels are introduced using cloud identification code and several IRAF (Image Reduction and Analysis Facility) tasks relating statistics. Removing of several ripple patterns using Fourier Transform is also discussed. It is found that BACKGROUND task within IRAF is very efficient for fitting and subtraction of base-line with varying functions. Cloud identification method along with the possibility of its application for analysis of cloud structure is described, and future data reduction method is discussed.

  • PDF

Parameter Estimation for Step Motor using RLS Algorithm (RLS알고리즘을 이용한 스텝 모터의 파라미터 추정)

  • Yon, Tae-Jun;Kim, Dong-Min
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.785-787
    • /
    • 1999
  • In this paper, recursive least square algorithm is presented to estimate the parameters of step motor under low-speed operation. Parameter estimation is important for compensating the input current by calculating the ratio of the motor torque constant and detent torque constant that causes torque-ripple in low-speed applications. On-line parameter estimation process is a preliminary procedure to apply step motor to adaptive control. Computer simulation shows that the estimated parameters converge in finite time.

  • PDF

Design of real time FIR filter for removal of noise in ECG (ECG 신호의 잡음 제거를 위한 실시간 FIR 필터의 설계)

  • 황선철;이경중;이명호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.690-693
    • /
    • 1987
  • Base-line wandering and 60Hz noise in ECG are removed by linear phase FIR filter. The important problem in FIR filtering is to reduce the number of impulse response coefficients. It can be reduced by symmetrical impulse response. The ripple is improved by window function .omega.(n). And the determination of filter accuracy is proposed by PRD(percent rms difference) algorithm.

  • PDF

Instantaneously Active/Reactive Power Compensation of Distribution Static Compensator using Phase Shift (배전용 정지형 보상기의 위상변이를 이용한 순시 유효/무효전력 보상)

  • Hong, Sung-Min;Choi, Jong-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.468-469
    • /
    • 2010
  • DSTATCOM(Distribution STATic COMpensator) is one of the custom power devices, and protects a distribution line from unbalanced and harmonic current caused by non-linear and unbalanced loads. Conventional researches use a LPF(Low Pass Filter) to eliminate ripple component at the calculation of compensation current. This paper proposes a calculation of compensation current using phase shift that can be a counterproposal of conventional methods using LPF.

  • PDF

Green Mode Buck Switch for Low Power Consumption

  • Jang, KyungOun;Kim, Euisoo;Lim, Wonseok;Lee, MinWoo
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.397-398
    • /
    • 2013
  • Fairchild Green Mode off line buck switch for low standby power consumption and high reliability is presented. By reducing operating current and optimizing switching frequency, 20mW power consumption is achieved. High performance trans-conductance amplifier and green mode function improve the ripple and regulation in the output voltage. The conventional $FPS^{TM}$ buck and novel Fairchild buck switch are compared to show the improvement of performance. Experimental results are showed using 2W evaluation board.

  • PDF

Indirect Current Control Scheme in PWM Voltage - Sourecd Converter (PWM 전압형 컨버터의 간접전류 제어기법)

  • Kim, Hyong-Cheol;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.370-372
    • /
    • 1996
  • A control scheme for the Voltage-sourced PWM converter based on space vector equations is introduced. The main advantages of this new control scheme are that sinusoidal line currents with nearly unity power factor, ripple-free DC voltage output are achevied without current sensors. The dynamical equations with battery model is derived. The proposed scheme is verified by computer simulation.

  • PDF

A Novel Six-Level Inverter Topology with Capacitor Voltage Self-Balancing (커패시터 전압 자기 밸런싱 기능이 있는 새로운 6-레벨 인버터 토폴로지)

  • Pribadi, Jonathan;Lee, Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.316-317
    • /
    • 2020
  • In this paper, a novel six-level inverter is proposed. Voltage regulation is applied at DC-link and flying capacitors through the implementation of phase-shifted carrier-based modulation with zero-sequence voltage injection. The performance of the proposed structure has been verified under various modulation indices, where low voltage ripple is achieved at each capacitor and total harmonic distortions (THD) of line voltage at unity modulation index is about 15.95%.

  • PDF