• Title/Summary/Keyword: Ripple line

Search Result 147, Processing Time 0.033 seconds

A Study on Feedforward Compensation Method of IPMSM for EV with Non-sinusoidal BEMF (비 정현파 역기전압을 가지는 EV용 IPMSM의 전향보상 제어기법에 관한 연구)

  • Park, Gui-Yeo;Park, Jung-Woo;Ahn, Won-Il;Shin, Duck-Woong;Jeong, Moon-Seon;Moon, Chae-Joo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.573-578
    • /
    • 2013
  • In the case of the Back EMF voltage contains the harmonics, the motor torque ripple and vibration is occurred by the current pulsation, because IPMSM control algorithm is the model which is assumed that it contains a sinusoidal Back EMF voltage. To improve ride quality, in the case of IPMSM for EV, improving the torque control characteristics is necessary. Therefore, there is a need to minimize the influence of the harmonics. In this paper, the investigation to decrease the current distortion factor has been performed for improving torque control characteristics by applying the non-sinusoidal Back EMF to IPMSM model.

High-temperature superconducting band-pass filters for digital cellular communication system (고온 초전도체를 이용한 이동통신 기지국용 영역통과 필터에 관한 연구)

  • J. H. Lee;Y. H. Do;J. S. Kwak;C. O. Kim;J. P. Hong;K. L. Lee;S. K. Han;K. Char
    • Progress in Superconductivity
    • /
    • v.4 no.2
    • /
    • pp.132-136
    • /
    • 2003
  • Extremely selective high temperature superconducting (HTS) band -pass filters were developed for the base transceiver station applications of Digital Cellular communication Service (DCS). The filters have a bandwidth of 25 MHz at a center frequency of 834 MHz. There are 12 resonators which have spiral-meander microstrip-line structures in order to reduce far-field radiations with a reasonable tunability. As a result, the size of filters is 5 mm $\times$ 17 mm $\times$ 41 mm. Device characteristics exhibited a low insertion loss of -0.4 dB with a -0.2 dB ripple and a return loss better than -10 dB in the pass-band at 65 K. The out-of-band signals were attenuated better than 60 dB about 3.5 MHz from the lower band edge, and 3.8 MHz from the higher band edge.

  • PDF

Design and Test Results of High-Power Pulse Generator System for Industrial Accelerator Application (산업용 가속기용 고출력 펄스시스템의 설계와 시험)

  • Jang, S.D.;Kim, S.H.;Yang, H.Y.;Cho, M.H.;Ko, I.S.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1370_1372
    • /
    • 2009
  • A conventional linear accelerator system requires a flat-topped pulse with less than $\pm$ 0.5% ripple to meet the beam energy spread requirements and to improve pulse efficiency of RF systems. A a line-type pulsed modulator is widely used in pulsed power circuits for applications such as accelerators, radar, medical radiation, or ionization systems. The high-voltage pulse generator system with an output voltage of 284 kV, a pulse width of $10{\mu}s$, and a rise time of $0.84{\mu}s$ has been designed and fabricated to drive a klystron which has 30-MW peak and 60-kW average RF output power. The high-voltage test was performed using the klystron load. This thesis describes the design and test results of high-power pulse generator system for industrial accelerator application. The experimental results were analyzed and compared with the design.

  • PDF

Torque ripple reduction based on MRAS observer for the interior PMSM with back emf harmonics (왜곡된 역기전력을 갖는 매입형 영구자석 동기 전동기의 MRAS관측기를 이용한 토크리플 저감)

  • Jin, Yong-Sin;Cho, Kwan-Yuhl;Kim, Hag-Wone;Lim, Byung-Kuk;Han, Byung-Moon
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.229-230
    • /
    • 2012
  • 본 논문에서는 왜곡된 역기전력을 갖는 매입형 영구자석 동기전동기의 토크리플 저감 방법을 제안한다. 역기전력에 왜곡성분이 있는 경우 정현파 전류로 모터 제어 시 역기전력의 왜곡으로 인한 토크리플은 전동기의 진동 증대 및 효율 저하의 요인이 된다. 이러한 토크리플에 의한 전동기의 진동은 특히 저속에서 문제가 된다. 저속운전 시 전동기의 토크리플을 저감하기 위해서는 역기전력의 왜곡에 의한 토크리플을 줄일 수 있는 토크리플 보상 전류제어가 필요하다. 이 경우 토크리플 보상전류를 구하기 위해서는 역기전력의 왜곡성분에 대한 정보가 필요하다. 본 논문에서는 역기전력의 왜곡성분을 off_line 방식이 아닌 전류기반 MRAS 관측기를 사용하여 실시간으로 추정하여 토크리플 저감전류를 보상함으로써 토크리플을 저감한다. 제안된 토크리플 저감 알고리듬은 시뮬레이션을 통해 검증한다.

  • PDF

Oven Temperature Control by Integral - Cycle Binary Rate Modulation Technique

  • Tipsuwanporn, V.;Piyarat, W.;Chochai, N.;Jamjan, K.;Paraken, Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.278-280
    • /
    • 1999
  • This paper proposes controlling of temperature in an oven by using 4 bits Integral - Cycle Binary Rate Modulation (IBRM) method and ac line with frequency 50 Hz. Microcontroller MCS-51 controls IBRM according to Proportional Integral controller (PI) function. Discrete signals are used in the system modeled by using Ziegler Nichols principle for analyzing the stability before designing the system. This procedure makes it easy to investigate system response. The system is implemented by 4 bits digital circuit which gives 320 patterns of ac signal fur controlling the generation of energy for 3,000 watts thermal coil every 20 ms of each cycle. We divide scan time (Ts$\sub$n/) in to 20 intervals, 1 ms interval is selected to generate 16 patterns IBRM. Because of this method gives the ripple lower than 2% it generates less noise fur system. Moreover, we can consider whole system from the time model of control procedure and IBRM algorithm at 40-200$^{\circ}C$ with ${\pm}$ 1$^{\circ}C$ error in the 1 cubic meter oven.

  • PDF

A Detection Method of Grid Voltage for Grid Support Operation of an Inverter-based Renewable Energy Generation System (인버터 기반 신재생 에너지 발전 시스템의 계통 지원 운전을 위한 계통 전압 검출 방법)

  • Ahn, Hyun-Chul;Song, Seung-Ho
    • New & Renewable Energy
    • /
    • v.9 no.2
    • /
    • pp.51-57
    • /
    • 2013
  • The Grid code is being strengthen as increase of renewable energy ratio. Especially, the grid connection regulations are continuously being updated for stable operation of power grids. Static grid support and Dynamic grid support must make an accurate measure at Grid connected point because they needs control algorithm individually. It has to exactly measure voltage including switching ripple at the output of the inverter generating system. In addition, it is necessary to have an accurate voltage measurement when the situation rapidly changing the grid impedance is caused by the input of serial impedance of transformer and line impedance as well as Grid Fault Device. In this paper, We propose a new detection method of grid voltage to calculate accurately the r.m.s voltage of the grid connection point along the standard required by the low voltage regulation. We verified performance through simulation grid fault device.

Design of waveguide cavity resonator band pass filter using slot coupling (슬롯결합을 이용한 도파관 공동 공진기 대역통과 필터 설계)

  • Jo, Seong-Mun;Park, Bo-Youn;Choi, Sung-Youl;Ko, Young-Ho
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.288-293
    • /
    • 2003
  • In this paper, Filter could use to IMT2000 repeater using resonator of Comb-line form that has waveguide structure and designed. Coupled resonators designed using slot in wall between resonators to compact. 5-stage resonators have equal structure and input and output part was optimized to get into minimum impedance. Band pass filter characteristic satisfied design condition as result that used Chebyshev function that have 0.2 dB ripple and analyze using simulation tool.

  • PDF

A development of Diagnosis Monitoring System for UPS DC Link Capacitors using Zigbee Wireless Communication (Zigbee 무선통신을 이용한 UPS DC링크 커패시터의 고장 모니터링 시스템 개발)

  • Kim, Dong-Jun;Shon, Jin-Geun;Jeon, Hee-Jong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.1
    • /
    • pp.41-46
    • /
    • 2012
  • Electrolytic power capacitors have been widely used in power conversion system such as inverter or UPS because of characteristics of large capacitance, high-voltage and low-cost. The electrolytic capacitor, which is most of the time affected by the aging effect, plays a very important role for the power-electronics system quality and reliability. Therefore it is important to diagnosis monitoring the condition of an electrolytic capacitor in real-time to predict the failure. In this paper, the on-line remote diagnosis monitoring system for UPS DC link electrolytic capacitors using low-cost single-chip zigbee communication modules is developed. To estimate the health status of the capacitor, the equivalent series resistor(ESR) of the component has to be determined. The capacitor ESR is estimated by using RMS computation using BPF modeling of DC link ripple voltage/current. Zigbee-based hardware experimental results show that the proposed remote capacitor diagnosis monitoring system can be applied to UPS successfully.

Analysis and Control of a Modular MV-to-LV Rectifier based on a Cascaded Multilevel Converter

  • Iman-Eini, Hossein;Farhangi, Shahrokh;Khakbazan-Fard, Mahboubeh;Schanen, Jean-Luc
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.133-145
    • /
    • 2009
  • In this paper a modular high performance MV-to-LV rectifier based on a cascaded H-bridge rectifier is presented. The proposed rectifier can directly connect to the medium voltage levels and provide a low-voltage and highly-stable DC interface with the consumer applications. The input stage eliminates the necessity for heavy and bulky step-down transformers. It corrects the input power factor and maintains the voltage balance among the individual DC buses. The second stage includes the high frequency parallel-output DC/DC converters which prepares the galvanic isolation, regulates the output voltage, and attenuates the low frequency voltage ripple ($2f_{line}$) generated by the first stage. The parallel-output converters can work in interleaving mode and the active load-current sharing technique is utilized to balance the load power among them. The detailed analysis for modeling and control of the proposed structure is presented. The validity and performance of the proposed topology is verified by simulation and experimental results.

On-line Parameter Estimation of IPMSM Drive using Neural Network (신경회로망을 이용한 IPMSM 드라이브의 온라인 파라미터 추정)

  • Park, Ki-Tae;Choi, Jung-Sik;Ko, Jae-Sub;Lee, Jung-Ho;Kim, Jong-Kwan;Park, Byung-Sang;Chung, Dong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.761-762
    • /
    • 2006
  • A number of techniques have been developed for estimation of speed or position in motor drives. The accuracy of these techniques is affected by the variation of motor parameters such as the stator resistance, stator inductance or torque constant. This paper is proposed a neural network based estimator for torque and stator resistance in IPMSM Drives. The neural weights are initially chosen randomly and a model reference algorithm adjusts those weights to give the optimum estimations. The neural network estimator is able to track the varying parameters quite accurately at different speeds with consistent performance. The neural network parameter estimator has been applied to slot and flux linkage torque ripple minimization of the IPMSM. The validity of the proposed parameter estimator is confirmed by the operating characteristics controlled by neural networks control.

  • PDF