• Title/Summary/Keyword: Ripple Rate

Search Result 82, Processing Time 0.033 seconds

Wire Feeding Speed Control for Improving Welding Performances in Inverter Arc Welding Machine

  • Gho, J.S.;Chae, Y.M.;Chae, J.W.;Mok, H.S.;Choe, G.H.;Shin, W.S.
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.464-469
    • /
    • 1998
  • In the conventional wire feeder drives of welding machine, one thyristor or MOSFET device was used for half-wave phase control circuit and direct EMF measurement was used for sensing the wire feed rate. But the method using one switching device has poor response for sudden disturbance and it has latent speed ripple. It can affect some welding performance such as spatter generation and irregular bead formming. Therefore, the welding performance using full-bridge PWM speed control scheme was compared with conventional driving scheme was compared with conventional driving scheme and experimented in this paper. The results of experiment confirm the posibility of welding performance improvement by proposed constant speed control scheme in wire feeding drive of welding machine.

  • PDF

Reduction of the Prominent Peak of Tone Noise in Air Conditioning Units (공조기기에서 발생하는 장한 피크의 톤 소음 저감을 위한 연구)

  • Park, Jeong-Il;Kang, Jeong-Hoon;Joo, Jae-Man
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.946-950
    • /
    • 2006
  • This paper proposed the ways for reduction of the prominent peak of the tone noise in air conditioning units. In order to find out the sources of the tone noise, the resonant frequencies and modes of the fans were investigated. Also, the effects of the ambient temperatures and material properties of the fans on the tone noise were studied. From the experiments, it was shown that the tone noise was greatly influenced by the torsional resonance of the fan and motor system and commutation frequency. In other words, the torsional resonance of the fan and motor system has not to be close to the commutation frequency (torque ripple frequency) which creates a rate of change in the angular acceleration in order to reduce the tone noise in air conditioning units.

  • PDF

The Grid Connected Characteristics of 1.2kW Fuel-cell Converter (1.2kW급 연료전지의 전력변환기의 연계 특성)

  • Liao, Dan-Jian;Son, Gyoung-Jong;Cho, Su-Eog;Park, Sung-Jun;Choi, Joon-Ho;Moon, Chae-Joo
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.438-440
    • /
    • 2007
  • This paper shows a new kind of push-pull switching converter for fuel-cell system and analyses the connected characteristics of it. In these characteristics, we are concerned about the high harmonic rate of output current, we also have designed the filter system for the inverter. Besides, the characteristics should be certified better if the ripple of the fuel-cell output current has been eliminated.

  • PDF

DC/DC Converter Design for 7kW Fuel Cell (7kW 연료전지용 DC/DC 컨버터 설계)

  • Kim, Ga-In;Shin, Min-Ho;Lee, Jung-Hyo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.2
    • /
    • pp.150-156
    • /
    • 2022
  • This study proposes a design method of fuel cell DC/DC converter using in 5-ton forklift. For efficient hydrogen usage, targeted fuel cell system recirculates discarded hydrogen after fuel cell reaction. Recirculating hydrogen contains much impurities that reduces output power, increasing pressure that can damage the internal fuel cell reaction system. The proposed DC/DC converter effectively converts fuel cell power considering the voltage drop rate to reflect the recirculating hydrogen. Then, frequency control method is used to regulate the current ripple amount for battery and fuel cell hybrid configuration. Proposed power converter system design and control methods are verified in a practical fuel cell system that implements recirculating hydrogen.

Design of Closed-Form QMF Filters with Maximally Flat and Half-Band Characteristics in the Frequency Domain (주파수 영역에서 최대평탄과 하프대역 특성을 갖는 폐쇄형 QMF 필터들의 설계)

  • Jeon, Joon-Hyeon
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.4 s.316
    • /
    • pp.70-77
    • /
    • 2007
  • Two kinds of QMF(Quadrature Mirror Filter) pairs are used in JPEG2000 standard, which don't have QMF distortions. However, the QMF pairs have the main disadvantages such that there are gentle roll-off rate, ripples in the passband and unequal band decomposition. In this paper, Maxflat(maximally flat) QMF pairs with a half-band gain are proposed for overcoming these problems. Maxflat QMF pairs are realized due to generalized closed-form formulas, and the filters have maximally flat response in the passband/stopband as well as sharp roll-off rate in the transition band. Comparing proposed filters and JPEG2000's filters in frequency domain, it is found that proposed filters have better performance JPEG2000's filters. Moreover, Maxflat QMF pairs show stopband-attenuation exceeding 200 dB almost everywhere.

A Study on the Effect of Delinquency Rate of Real Estate PF on Macroeconomic Variables (거시경제변수에 따른 부동산PF 연체율에 관한 연구)

  • Roh, Chi-Young;Kim, Hyung-Joo
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.4
    • /
    • pp.416-427
    • /
    • 2018
  • As the loan size of real estate PF is huge, its market ripple effect gets bigger when overdue occurs. Accordingly, the management of the delinquency rate and macroeconomic analysis are required. As the preceding research mainly proceeded with microeconomic analysis through the real estate PF data of individual banks to evaluate importance of list or analyzed core factors for delinquency, it lacked research on comprehensive real estate PF size. In order to overcome the limitations of such data, this research studied real estate PF delinquency rate of the entire market and effect relationship by the size. The research utilized the size of real estate PF loans, money supply, interest rate, consumer price index(CPI), and GDP data. Also, it applied the first model of VECM as linear relationship between at least two or more variables, following the result of co-integration test. As a result of Granger-causality test, the real estate PF loans delinquency rate is influenced by their loan size, and as a result of impulse response analysis, the interest rate is shown to be affecting delinquency rate the most. Interest rate could risesomeday and aggravate the delinquency rate of real estate PF. Also, risk exposure could be serious as the loan size increases.Therefore, the management of real estate PF delinquency rate requires continuous monitoring, tracking and observing issued loans from a macro point of view. The plans to prevent delinquency will be necessary.

Design of High Frequency Resonant Inverter Type X-Ray Generator (고주파 공진형 인버터식 X선 발생장치의 설계)

  • Lee, Seong-Gil;Park, Su-Gang;Baek, Hyeong-Rae;Jeong, Su-Bok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.1
    • /
    • pp.34-39
    • /
    • 2002
  • Most X-ray generator had been used do rectifier type transformer high tension generator which is supplied in a clinical diagnosis. But it is difficult to miniaturize and become light weight. Also, because the ripple rate of tube voltage is high, X-ray generating efficiency is very low. Therefore, it is supplied gradually from abroad being developed high tension generator for inverter type X-ray generator which use semi-conductor switching element for electric power that have high speed switching ability to solved these problem. But, semi-conductor element of big capacity are used by X-ray tube's big consumption power and diffusion is difficult in the small size hospital because production cost is ascending by doing digital control through DSP and product price becomes expensive. Therefore, in this paper, design and manufactured CR type voltage divider for feedback control of tube voltage of high frequency resonance type inverter and high tension transformer for high frequency to apply economical diffusion type X-ray generator which have wide output voltage and load extent. It is Proved do X-ray generator and stability of X-ray tube's output characteristics through an experiment.

Test-Field Construction for Long-term Reliability of EHV Underground Transmission Cable (초고압 지중케이블 장기신뢰성 실증시험장 구축)

  • Kim, Jin;Kang, Ji-Won;Jang, Tae-In;Yang, Byeung-Mo;Park, Jun-Woo;Park, Hung-Sok;Yoon, Hyung-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.383_384
    • /
    • 2009
  • After the 1970s, the importance of underground transmission systems increased and the construction rate of underground transmission lines also showed increasing trends each year, especially in metropolitan areas. Accordingly the social ripple effects are very large and wide when the fault occurs in underground power system, and the amount of time and money spent to restore the system also increases. So we must ensure stable operation and long-term reliability of the facilities. In Korea's case, long-term reliability tests for EHV power cables and accessories progressed poorly because equipment was not compatible for long-term reliability tests. Therefore we planned to construct a long-term reliability test field for EHV underground cables in order to ensure international quality reliability and optimal power cable operation techniques. The Gochang Underground Cable Test Field is under construction, funded by the Korean government, the govenment's union investment department, KEPCO, KERI and three private cable corporations. This project began in March, 2005 and will be completed by February, 2010. It is designed to promote joint research by incorporating several types of test equipment, construction of operating facilities, and being an internationally certified authority.

  • PDF

Steady State and Transient Analysis of Switched Reluctance Motor Drive Fed from a Controlled AC-DC Rectifier

  • Moussa, Mona Fouad
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1495-1502
    • /
    • 2017
  • The Theory of operation of switched reluctance motors (SRM) depends on the reluctance torque, where energy is transferred to stator winding only. Although its construction is simple, the electrical design is complex, due to the switching configuration needed to deliver power to stator coils. However, because of the nonlinearly of magnetic circuit, SRM has torque ripple. This paper proposes a new strategy to drive SRM from a single-phase AC supply. Each stator winding is connected to AC-DC or AC-AC converters, which is called branch. All branches are connected in parallel to a single-phase AC supply. A shaft encoder allows current production in stator winding during the positive torque production region and terminates it during the negative torque production region. A magnetic flux is produced between stator poles when current is supplied from AC supply to stator coil and repeats many cycles as long as the rate of change of stator inductance is positive. Different possibilities for the configurations of AC-AC or AC-DC converters are introduced to drive SRM from the single-phase AC supply. A case study is presented for a SRM fed from AC supply through semi-controlled AC-DC converter is presented. A simulation model is introduced and verified by experimental rig for two-phase SRM.

Operation characteristics of SFCLs combined with a transformer in three-phase power system

  • Jung, B.I.;Choi, H.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.30-33
    • /
    • 2013
  • The studies of superconducting fault current limiter (SFCL) for reduction of the fault current are actively underway in the worldwide. In this paper, we analyzed the characteristics of a new type SFCL using the conventional transformer and superconducting elements combined mutually. The secondary and third windings of this SFCL were connected the load and the superconducting element, respectively. The electric power was provided to load connected to secondary windings of the transformer in normal state of power system. On the other hand, when the fault occurred in power system, the fault current was limited by closing the line of third winding of the transformer. At this time, the ripple phenomenon of the fault was minimized by opening the fault line in secondary winding of a transformer in power system. The sensing of the fault state was performed by the CT(current transformer) and then turn-on and turn-off switching behavior of the SFCL was performed by the SCR(silicon-controlled rectifier). As a result, the proposed SFCL limited the fault current within a half-cycle efficiently. We confirmed that the fault current limitation rate was changed according to the winding ratio of a transformer.