• Title/Summary/Keyword: Rinse rate

Search Result 29, Processing Time 0.023 seconds

Development of PSA Process for Medical Oxygen Generator (의료용 산소발생기 제작을 위한 PSA 공정의 개발)

  • Choi, Jae-Wook;Na, Byung-Ki
    • Clean Technology
    • /
    • v.15 no.2
    • /
    • pp.75-80
    • /
    • 2009
  • In order to separate oxygen from air, the effects of feed gas flow rate and rinse gas flow rate on the product purity and flow were examined using 2 bed PSA with 4 step cycle. The addition of product pressurization step increased the product purity and flow rate. The addition of pressure equalization increased the product flow rate. The test product was manufactured and the purity and flow rate of product oxygen was examined. The results were compared with the commercial medical oxygen generator of 5 ${\ell}/min$ and 90% oxygen purity.

STUDIES ON THE EFFECT OF WEEKLY SELF APPLICATION WITH SODIUM FLUORIDE SOLUTION (불소자가도포의 치아우식증 예방효과에 관한 연구)

  • Jung, In-Whan
    • The Journal of the Korean dental association
    • /
    • v.16 no.8 s.111
    • /
    • pp.619-624
    • /
    • 1978
  • The use of mouth-rinses containing sodium fluoride after tooth brushing has been proposed as a potentially useful measure for the prevention of dental caries in the practice of public health. About 700 middle school girls rinsed their mouths in the school once a week with sodium fluoride sodution after tooth-brushing. Tooth brushing was practiced everyday after meals and the rinses were carried out under the supervision of the teachers. The procedure consisted of gargling 10cc of fluoride solution for one minute and immediately followed by a second rinse with tap water. The rinsing was started in May 1976 and continued for one year. The results were as follows: 1) The inhibition of the 'D' Person rate was 76.04%, 'M' person rate was 80.79%, 'F' person rate was 4.06% and, 'D.M.F.' person rate was 76.86%. 2) the reduction of the 'D.T.' Index was 81.94%, 'M.T.' Index was 85.71%, 'F.T.' Index was 7.69% and, 'D.M.F.T.' Index was 76.83%. 3) Mouth rinsing with 0.3% NaF solution and tooth brushing are of value in the mass control of dental caries.

  • PDF

COMPARATIVE STUDY ON THE EFFICACY OF DIGITAL IMAGING FIBER-OPTIC TRANS-ILLUMINATION AND LASER FLUORESCENCE IN MONITORING THE REMINERALIZATION PROCESS OF INCIPIENT SMOOTH SURFACE ENAMEL LESIONS (Digital Imaging Fiber-Optic Trans-Illumination과 Laser Fluorescence를 이용한 평활면 초기우식증의 재광화에 관한 비교 연구)

  • Hwang, Kyu-Seon;Yoo, Seung-Hoon;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.2
    • /
    • pp.183-191
    • /
    • 2007
  • Through out the world dental caries seems to be decreased as it is difficult to make an accurate diagnosis for dental caries. The traditional diagnostic method which is probing and x-ray taking has many limitations to diagnose the early caries, so there were recommendations for the needs of new equipments such as laser fluorescence(LF), digital imaging fiber-optic trans-illumination(DIFOTI), and quantitative light fluorescence (QLF) which were developed from various study results. Also confocal laser scanning microscopy(CLSM) and ultrasonics are used for research progression. This study is to evaluate whether it is possible to monitor accurately for remineralization amount of enamel surface early caries using DIFOTI or LF After inducing artificial caries to bovine teeth to 10 participants remineralization was enhanced by 0 ppm and 500 ppm fluoride mouth rinse solution for 3 weeks. Then they were cross sectioned and analyzed using gold standard of the lesion depth measured by CLSM. The following results were obtained: 1. The measured percentage of light intensity(luminosity ratio) by DIFOTI increased with remineralization period, and showed significant reverse correlation with lesion depth measured by CLSM (p<0.01). 2. The measurement of laser fluorescence increased with remineralization period, and showed significant correlation with lesion depth measured by CLSM (p<0.01). 3. To the result for CLSM, 500 ppm fluoride mouth rinse group showed rapid rate for decreased tendency of lesion depth than 0 ppm fluoride mouth rinse group. In conclusion DIFOTI system was used to measure accurately for the remineralization amount of early surface caries, it is a very useful equipment to detect precisely the changes for early enamel caries remineralization during treatments.

  • PDF

Monitoring of Methanol Levels in Commercial Detergents and Rinse Aids (시판 세척제 및 헹굼보조제 중 메탄올 함량 모니터링)

  • Park, Na-youn;Yang, Heedeuk;Lee, Jeoungsun;Kim, Junghoan;Park, Se-Jong;Choi, Jae Chun;Kim, MeeKyung;Kho, Younglim
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.3
    • /
    • pp.263-268
    • /
    • 2019
  • Methanol is a toxic alcohol used in various products such as antifreeze, detergent, disinfectant and industrial solvent. In the human body, methanol is oxidized to formaldehyde and formic acid, which can lead to metabolic acidosis, optic nerve impairment, and death. In this study, the methanol levels in detergents (n=191) and rinse aids (n=13) were analyzed by gas chromatography-headspace-mass spectrometry (GC-HS-MS). Limit of detection was 1.09 mg/kg, accuracy and precision were 91.1-97.9% and <10%, and it was suitable for quantitative analysis. This analysis method was simple and fast with a higher recovery rate than the conventional MFDS (Ministry of Food and Drug Safety) method of diluting the sample in water and putting it in a headspace vial.

Microhybrid versus nanofill composite in combination with a three step etch and rinse adhesive in occlusal cavities: five year results

  • Tuncer, Safa;Demirci, Mustafa;Oztas, Evren;Tekce, Neslihan;Uysal, Omer
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.4
    • /
    • pp.253-263
    • /
    • 2017
  • Objectives: The aim of the study was to evaluate the 5-year clinical performance of occlusal carious restorations using nanofill and microhybrid composites, in combination with 3-step etch-and-rinse adhesives, in patients who were going to commence orthodontic treatment. Materials and Methods: A total of 118 restorations for occlusal caries were conducted prior to orthodontic treatment. Occlusal restorations were performed both with Filtek Supreme XT (3M ESPE) and Filtek Z250 (3M ESPE) before beginning orthodontic treatment with fixed orthodontic bands. Restorations were clinically evaluated at baseline and at 1, 2, 3, 4, and 5-year recalls. Results: None of the microhybrid (Filtek Z250) and nanofill (Filtek Supreme XT) composite restorations was clinically unacceptable with respect to color match, marginal discoloration, wear or loss of anatomical form, recurrent caries, marginal adaptation, or surface texture. A 100% success rate was recorded for both composite materials. There were no statistically significant differences in any of the clinical evaluation criteria between Filtek Z250 and Filtek Supreme XT restorations for each evaluation period. Conclusions: The composite restorations showed promising clinical results relating to color matching, marginal discoloration, wear or loss of anatomical form, recurrent caries, marginal adaptation, and surface texture at the end of the 5-year evaluation period.

Physical and Biochemical Mechanisms Associated with Beef Carcass Vascular Rinsing Effects on Meat Quality: A Review

  • Hwang, Koeun;Claus, James R.;Jeong, Jong Youn;Hwang, Young-Hwa;Joo, Seon-Tea
    • Food Science of Animal Resources
    • /
    • v.42 no.3
    • /
    • pp.389-397
    • /
    • 2022
  • Carcass vascular rinsing and chilling involves infusing a chilled isotonic solution (98.5% water and a blend of mono- and di-saccharides and phosphates) into the vasculature immediately upon exsanguination. Primary purposes of carcass vascular rinsing are to (1) effectively remove residual blood from the carcass; (2) lower internal muscle temperature rapidly; and (3) optimize pH decline by effective delivery of glycolytic substrates in the rinse solution. Previous studies have revealed that the beef carcass vascular rinsing early postmortem positively affects meat quality, product shelflife, and food safety. Thus, the objective of this review is to provide a more comprehensive understanding of the physical and biochemical mechanisms associated with beef carcass vascular rinsing, focusing on the relationship between quality attributes (CIE L*, a*, b*; chemical states of myoglobin; oxygen consumption and sarcomere length) and muscle metabolic response to various substrate solutions (Rinse & Chill®, fructose, sodium phosphate, and dipotassium phosphate) that stimulate or inhibit the rate of glycolysis early postmortem. In addition, this review discusses the absence of metabolite residues (phosphorus, sodium, and glucose) related to the application of the chilled isotonic solution. This review primarily focuses on beef and as such extending the understanding of the mechanisms and meat quality effects discussed to other species associated with vascular rinsing, in particular pork, may be limited.

The process optimization of in-situ H$_2$ bake and GeH$_4$ clean in low temperature Si epitaxy using design of experiment (저온 Si계 에피 성장기술에서 실험계획법에 의한 in-situ H$_2$ bake 및 GeH$_4$ clean 공정 최적화)

  • 이경수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.11a
    • /
    • pp.54-58
    • /
    • 1994
  • H$_2$ bake and GeH$_4$ clean are used as a in-situ pre-clean method in low temperature Si based epitaxial growth technology using rapid thermal processing chemical vapor deposition (RTPCVD). In this paper, the H$_2$ bake and GeH$_4$ clean processes are optimized for low surface defect density using Taguchi method. In H$_2$ bake process, the epitaxial growth temperature affects dominantly on the surface defect density, and the next affecting factors are H$_2$ bake temperature and rinse time in de-ionised water. In GeH$_4$ clean process, GeH$_4$ clean temperature affects most strongly on the surface defect density, and the minor factor is GeH$_4$flow rate. The optimum process conditions predicted fly Taguchi method agree well with tile experimental data in both in-situ clean processes.

Removal of Lead from Lead-loaded Activated Carbon Using Water Electrolysis (물의 전기분해를 이용한 납-흡착 활성탄으로부터 납의 제거)

  • Kim, Bu Ung;Sung, Kyoung Sik;Choi, Yeon Seok
    • Applied Chemistry for Engineering
    • /
    • v.10 no.6
    • /
    • pp.929-933
    • /
    • 1999
  • Under the condition of water electrolysis in aqueous hydrochloric acid as the electrolyte, the lead removal from the lead-loaded activated carbon packed on the anode was investigated. The adequate flow condition is a total flow rate of 10 mL/min in the same flow rate ratio to both electrodes. The increase of current decreases pH values at the anode and the decrease of pH leads to the lead removal. This work shows that the water electrolysis is an efficient method for the lead removal from the lead-loaded activated carbon with a reduction in quantity of the chemical used in comparison with the acid rinse.

  • PDF

Effects of solvent volatilization time on the bond strength of etch-and-rinse adhesive to dentin using conventional or deproteinization bonding techniques

  • de Sousa, Jose Aginaldo Junior;Carregosa Santana, Marcia Luciana;de Figueiredo, Fabricio Eneas Diniz;Faria-e-Silva, Andre Luis
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.3
    • /
    • pp.202-208
    • /
    • 2015
  • Objectives: This study determined the effect of the air-stream application time and the bonding technique on the dentin bond strength of adhesives with different solvents. Furthermore, the content and volatilization rate of the solvents contained in the adhesives were also evaluated. Materials and Methods:Three adhesive systems with different solvents (Stae, SDI, acetone; XP Bond, Dentsply De Trey, butanol; Ambar, FGM, ethanol) were evaluated. The concentrations and evaporation rates of each adhesive were measured using an analytical balance. After acid-etching and rinsing, medium occlusal dentin surfaces of human molars were kept moist (conventional) or were treated with 10% sodium hypochlorite for deproteinization. After applying adhesives over the dentin, slight air-stream was applied for 10, 30 or 60 sec. Composite cylinders were built up and submitted to shear testing. The data were submitted to ANOVA and Tukey's test (${\alpha}=0.05$). Results: Stae showed the highest solvent content and Ambar the lowest. Acetone presented the highest evaporation rate, followed by butanol. Shear bond strengths were significantly affected only by the factors of 'adhesive' and 'bonding technique' (p < 0.05), while the factor 'duration of air-stream' was not significant. Deproteinization of dentin increased the bond strength (p < 0.05). Stae showed the lowest bond strength values (p < 0.05), while no significant difference was observed between XP Bond and Ambar. Conclusions: Despite the differences in content and evaporation rate of the solvents, the duration of air-stream application did not affect the bond strength to dentin irrespective of the bonding technique.

Relationship between Saliva Factors Measured Using the SILL-Ha Saliva Test System and Blood Cell Counts according to Perceived Stress Scale Scores in Female College Students

  • Lee, Sun-Mi;Jung, Eun-Ha;Jun, Mi-Kyoung
    • Journal of dental hygiene science
    • /
    • v.21 no.3
    • /
    • pp.150-157
    • /
    • 2021
  • Background: Stress as a cause of mental health problems is known to be more prevalent in women than in men and has a negative effect on several aspects of physical health, such as the composition of blood and saliva. This study investigated the relationship of perceived stress with blood cell counts, saliva flow rate, and saliva factors. Methods: We recruited women in their 20s with a high prevalence of stress. Stress was evaluated using the Korean version of the perceived stress scale. Blood tests included white blood cell, hemoglobin, and platelet. We then examined the saliva flow rate and cariogenic bacteria level, acidity, occult blood, buffer capacity, leukocyte level, protein level, and ammonia level using rinse water with the SILL-Ha saliva test system. Results: In a total of 70 participants, the average age was 21.64 years old, the average perceived stress score was 16.96±4.32, and high levels of stress were reported by 80% of the participants (n=56). The high-stress group had lower hemoglobin levels. In addition, the high-stress group showed a lower saliva flow rate than the low-stress group, and there was a difference in the salivary acidity and buffer capacity. The total perceived stress score showed a positive correlation with acidity and negative correlation with buffer capacity and the hemoglobin level. Conclusion: This study found that stress in female college students might affect the composition of blood and saliva. High levels of stress were positively correlated with the hemoglobin level, saliva flow rate, and acidity and negatively correlated with the buffer capacity.