• Title/Summary/Keyword: Ring-light

Search Result 219, Processing Time 0.025 seconds

Development of Ring Light for Shadowless Shooting for Medical Purpose (의료용 무영 촬영을 위한 링라이트 개발)

  • Cheon, Min-Woo;Cho, Kyung-Jae;Park, Yong-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.9
    • /
    • pp.708-713
    • /
    • 2010
  • In this research a ring light was developed so that a partial shadowless shooting for the patient's affected area at the medical treatment room and surgical operation room using high luminance light emitting diode (LED) for which attention is being paid as new lighting parts for medical purpose. LED which was applied to the development used high luminance three color LED for full color for which various color materialization and the adjustment of radiation intensity are possible and we can get white light in order to emphasize the delicate expression for generic tone of shooting object, strong highlight, simple shadow and three dimensional effect at the time of close-up shadowless shooting of the affected area. And at the time of design of ring light, the characteristics of LED and the loss of light at the time of penetrating light diffusion PC were considered so that intensity of illumination for over 150 lx can be obtained. The result of measurement of the intensity of illumination of the ring light that was developed revealed that maximum intensity of illumination of 225.7 lx was obtained, while smoke index was measured to be maximum 78 Ra in the case of Red(50%) Green(100%) and Blue LED(60%). We could confirm that response speed was also very fast as 1.72 ms.

Second Harmonic Generation and Frequency Stabilization of a Diode Laser Using an External Ring Resonator

  • Kwon, Taeg-Yong;Yang, Sung-Hoon;Lee, Ho-Seong
    • Journal of the Optical Society of Korea
    • /
    • v.2 no.1
    • /
    • pp.1-4
    • /
    • 1998
  • The second harmonic light of an 842 nm diode laser was generated from a KNbO3 crystal in an external ring resonator. The power of the second harmonic light was about 0.8 mV at an input fundamental power of 87 mW. The laser frequency was stabilized to the resonance frequency of the ring resonator, and the frequency fluctuation was measured as about 3 MHz.

Development of Ring Right for Medical Purpose (메디컬 링 라이트의 개발)

  • Cheon, Min-Woo;Park, Yong-Pil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.766-767
    • /
    • 2010
  • By using LED which is a light source which has been in the spotlight recently, the ring light for medical purposes was developed for shadowless shooting of local site in the affected area. The developed ring light was designed to be able to control the various quantity of light by using PWM (pulse width modulation) method, and by controlling each LED (light emitting diode) independently the regulation of color temperature and color rendering are possible. Also, the persistent light for continuous shooting of affected area and flash mode action for snap shooting are possible. In this study the response speed of momentary flash function was checked using interface circuit configured for momentary shadowless shooting of affected area.

  • PDF

Operation experience of 2 GeV PLS magnet power supplies (포항방사광가속기 2GeV 저장링용 전자석전원 장치의 운전경험)

  • Nam, Sang-H.;Jeong, Seong-H.;Han, Sung-H.;Suh, Jae-H.;Ha, Ki-M.;Yoon, Moo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.559-563
    • /
    • 1996
  • Total 215 magnet power supplies are under operation in Pohang Light Source(PLS). Current, voltage and peak power handling capabilities of DC power supply are in the range of 21 to 643V, 45 to 850A and 0.94 to 531KW, respectively. The DC power supplies can be categoriezed as uni-polar and bipolar power. Typical required stability and ripple of uni-polar power supplies are ${\pm}0.005%$ and ${\pm}0.05%$, respectively. The bipolar power supplies should be maintained within ${\pm}0.05%$ stability and ${\pm}0.5%$ ripple. Precise measurement results show that all power supplies meet or exceed the required specifications. The long term operation reliability to be sufficient for a stable operation of the Pohang Light Source.

  • PDF

A GORENSTEIN HOMOLOGICAL CHARACTERIZATION OF KRULL DOMAINS

  • Shiqi Xing;Xiaolei Zhang
    • Bulletin of the Korean Mathematical Society
    • /
    • v.61 no.3
    • /
    • pp.735-744
    • /
    • 2024
  • In this note, we shed new light on Krull domains from the point view of Gorenstein homological algebra. By using the so-called w-operation, we show that an integral domain R is Krull if and only if for any nonzero proper w-ideal I, the Gorenstein global dimension of the w-factor ring (R/I)w is zero. Further, we obtain that an integral domain R is Dedekind if and only if for any nonzero proper ideal I, the Gorenstein global dimension of the factor ring R/I is zero.

Fabrication of Spiropyran-functionalized Photochromic Hydrogel Lenses

  • Lee, Cheol Woo;Badon, Isabel Wen;Kim, Boram;Ryu, Geun-Chang;Kim, Ho-Joong
    • Journal of Integrative Natural Science
    • /
    • v.11 no.1
    • /
    • pp.39-43
    • /
    • 2018
  • Poly(hydroxyethyl methacrylate)-based hydrogels were surface-functionalized with spiropyran (SP) derivatives to obtain photochromic contact lenses. The contact lens reversibly changes from colorless to purple as response to UV light since colorless ring-closed SP state converts to purple ring-opened merocyanine (MC) state under UV light irradiation. The purple contact lens emits red light at 640 nm. Importantly, the presence of SP segments did not significantly affect the equilibrium water content (EWC) of the lens. SP-functionalized hydrogel lenses may find potential applications in developing light-adaptive ophthalmic materials.

Development of Multi-Purpose Variable Polarization Imaging System for Clinical Diagnosis (임상 진단용 다목적 가변 편광 영상장치 개발)

  • Bae, Young-Woo;Jung, Byung-Jo
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.265-270
    • /
    • 2007
  • Polarization imaging systems have been widely used to selectively characterize skin lesions. Nevertheless, current systems are used in single-mode due to the limitations of a fixed polarization mode and a single-working distance of light source, in which uniform light distribution is achieved on target area. To address such limitations, we developed a variable polarization imaging system based on multi-working distance of light source for various clinical diagnoses. In this study, we characterize the imaging system and present experiment results demonstrating its clinical usefulness. The imaging system consists of a CCD color camera, linear polarization filters, and a single-layered LED ring light source which provides uniform light distribution at multi-working distances. The first polarizer was placed on the light source and the second polarizer placed on objective lens provides continuous linear polarization angle from $0^{\circ}\;to\;90^{\circ}$. The clinical efficacy of the imaging system was investigated by acquiring and analyzing clinical images of skin wrinkle and dental plaque. With the experiments, we verified the potential usefulness of the imaging system for other clinical applications.

The Physical Property of Knitted Fabrics for High Sensible Garment according to the Spinning Method using Organic Cotton (오가닉 코튼 원사제조 방법에 따른 고감성 의류용 편성물의 물리적 특성)

  • Kim, Hyun-Ah;Kim, Hyun-Chel
    • Fashion & Textile Research Journal
    • /
    • v.15 no.4
    • /
    • pp.606-612
    • /
    • 2013
  • This paper investigates the physical properties of organic cotton staple yarns manufactured by ring and siro spinning methods as well as analyzes the physical properties of fabric specimens knitted with staple yarns made by these two methods. The breaking stress and evenness of organic ring staple yarns showed the same level for the Japanese specimens as the control yarns; in addition, the same coefficient for the friction of the manufactured yarns and Japanese specimens was also shown. These results makes it possible to manufacture organic staple ring yarns from organic cotton fibers. The tenacity and breaking strain of siro staple yarns were higher than ring staple yarns. The evenness and friction coefficient of siro staple yarns were lower than the ring staple yarns; in addition, hairiness and the number of siro staple yarns was significantly lower than the ring staple yarns. The dimensional stabilities of knitted fabrics by 20 Ne and 30 Ne siro staple yarns were superior to ring staple yarns. The color fastnesses of washing, perspiration and abrasion of knitted fabrics by two spinning methods showed the same level as the 4.5 grade; however, the light fastness of knitted fabric by siro staple yarns was superior to ring staple yarns. It was shown that the siro spinning method (using eco-friendly organic cotton fibers) was applicable to a high sensible knitted garment that overcame drawbacks of organic fibers related to shrinkable properties after washing and low color fastness to light.

Wave Simulation Technique for Large-scale Optical Sensor Designs (거대 스케일 광학 센서 설계를 위한 파동 시뮬레이션(Wave Simulation) 기법 연구)

  • Yong-Hoon Lee;Tae Yoon Kwon;Muhan Choi
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.1
    • /
    • pp.62-65
    • /
    • 2023
  • The wave mode calculation of a large-scale optical system in comparison to the working wavelength is practically impossible because the computational cost increases exponentially. In this paper, we propose a method that can obtain the optical mode in a large-scale optical system. The method carries out simulations by dividing the calculation area into blocks and moving along the light axis along which the light propagates. By applying this method to the calculation of resonant modes in a ring-type optical resonator, which is mainly used for ring laser optical gyro sensors, the efficiency of the proposed method was verified.