• Title/Summary/Keyword: Ring test

Search Result 769, Processing Time 0.032 seconds

A Study on GMA Welding Automation of STS301L Joint using Design of Experiment (실험계획법을 이용한 STS301L 이음재의 GMA 용접 자동화에 관한 연구)

  • Baek, Seung-Yeb;Sohn, Il-Seon
    • Journal of Welding and Joining
    • /
    • v.28 no.4
    • /
    • pp.49-54
    • /
    • 2010
  • Stainless steel sheets are widely used as the structural material for the railroad cars and the commercial vehicles. These kinds structures used stainless steel sheets are commonly fabricated by using the GMAW (gas metal arc welding). For fatigue design of GMA welded joints such as fillet and plug, ring type joint, it is important to obtain optimum design factor information on GMA welded joints. in this paper, analysis approach for fatigue test using design of experiment are evaluated optimum factor in GMA welded joint type and geometrical parameters of materials. Using these results, that factors applied to fundamental information for fatigue design.

Beat Control Using an Equivalent Ring Model (등가 종 모델을 이용한 맥놀이 조절법)

  • Kim, Seockhyun;Lee, Joonghyeok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.516-519
    • /
    • 2012
  • This study proposes a method of an equivalent bell model in order to tune the beat period of a Korean bell. In a Korean bell having a slight asymmetry, each circumferential mode splits into a mode pair which has a slight difference in frequency, and the interaction of the mode pair makes a beat in vibration and sound. An equivalent bell model which consists of an axi-symmetric bell and an equivalent point mass, has the same mode property as in a real bell. The equivalent bell model is constructed by the finite element analysis based upon the theory of a revolutionary shell Using the equivalent bell model, the beat period is predicted when the bell thickness is locally decreased to improve the beat property. The predicted result is verified by experiment on a test bell. The proposed method is useful to save the time required for tuning the beat period of a large bell.

  • PDF

A Study on the Implementation of MAC Layer of Token-passing Bus Network Based on Mini-MAP (Mini-MAP을 채택한 토큰-패싱 버스 네트워크의 MAC계층 구현에 관한 연구)

  • 강문식;조병선;박민용;이상배
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.28B no.5
    • /
    • pp.404-410
    • /
    • 1991
  • In this paper,a network interface unit of token-passing bus network and its driving software are implemented based on Mini-MAP. This network interface unit performs the function of MAC layer which is responsible for transmission and reception of frames as well as the management of logical ring. The driving software performs the management of data buffer and the report of errors, if ocoured, to the higher layer. Motorola MC68824 of is used as a TBC(Token Bus Controller) and Intel80186 as a CPU for network interface unit. The operation of network interface unit is verified by self-test which checks the functioning of TBC and CPU. In addition each module of driving software is tested to check the functions regarding transmission and reception of frames.

  • PDF

Mathematical Morphology Guided Automatic Unwrapping Isoclinic Phase Map in White Light Photoelasticity

  • Liu, Xiaomeng;Dai, Shuguang
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.643-648
    • /
    • 2015
  • By comparing the results calculated by atan() and atan2() functions, the correctly estimated region of isoclinic phase map is determined using morphological techniques. The isoclinic phase map is automatically unwrapped in the true phase range -π/2 to π/2. Demonstrations of the method on a disc and a ring under diametral compression are performed. Test results compare well with the theoretical results. Furthermore, the influences of principal stress direction and the range of isoclinic phase upon stress separation are discussed.

Leakage Prevention of Mechanical Seal in a Feed Water Pumpof Power Plant with Oxygen Water Treatment (산소주입 수처리 발전소용 급수펌프 밀봉장치의 누설방지)

  • Shin, Jung-Gook;Moon, Seung-Jae;Yoo, Hoseon
    • Plant Journal
    • /
    • v.7 no.1
    • /
    • pp.56-63
    • /
    • 2011
  • The identifying cause of leakage problems on mechanical seal in a feed water pump of power plant have been difficult because of technical limits of domestic mechanical seal manufacturer and the various conditions of power plants. This paper can get a conclusion through the consideration study and experiment test of mechanical seal characteristics of feed water pump depending on oxygen treatment as follows. The oxygen treatment increase dissolved oxygen and cause a corrosion on the mechanical seal stationary ring composed of antimony as well as leakage problems. For solving leakage problems of seal, to eliminate dissolved oxygen in the cooling water of seal with hydrazine injection can prevent leakage problems of mechanical seal in feed water pump.

  • PDF

Fatigue Life Evaluation on Compressive & Tensional Residual Stress Induced Materials and Residual Stress Measurement using Hole Drilling Method (HDM을 이용한 잔류응력측정과 압축·인장 잔류응력이 인가된 재료의 피로수명평가)

  • Baek, Seung Yeb
    • Journal of Welding and Joining
    • /
    • v.31 no.2
    • /
    • pp.43-48
    • /
    • 2013
  • This paper Investigated the characteristics of residual stress in weld is composed of typical specimens, are investigated by using three dimensional thermal elasto-plastic FEM analysis. Numerically calculated residual stresses in the gas welds were then compared with experimental results obtained by the hole-drilling method. Using the stress amplitude (${\sigma}a$)R at the hot spot point of gas weld, the relations obtained as the fatigue test results for typical specimens having various dimensions and shapes were systematically rearranged to obtain the (${\sigma}a$)R-Nf relationship. It was found that more systematic and accurate evaluation of the fatigue strength of plug- and ring-type gas-welded joints can be achieved by using (${\sigma}a$)R.

Cosmic Distances Probed Using The BAO Ring

  • Sabiu, Cristiano G.;Song, Yong-Seon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.39.1-39.1
    • /
    • 2016
  • The cosmic distance can be precisely determined using a 'standard ruler' imprinted by primordial baryon acoustic oscillation (hereafter BAO) in the early Universe. The BAO at the targeted epoch is observed by analyzing galaxy clustering in redshift space (hereafter RSD) of which theoretical formulation is not yet fully understood, and thus makes this methodology unsatisfactory. The BAO analysis through full RSD modeling is contaminated by the systematic uncertainty due to a non--linear smearing effect such as non-linear corrections and uncertainty caused by random viral velocity of galaxies. However, BAO can be probed independently of RSD contamination using the BAO peak positions located in the 2D anisotropic correlation function. A new methodology is presented to measure peak positions, to test whether it is also contaminated by the same systematics in RSD, and to provide the radial and transverse cosmic distances determined by the 2D BAO peak positions. We find that in our model independent anisotropic clustering analysis we can obtain about 2% and 5% constraints on $D_A$ and $H^{-1}$ respectively with current BOSS data which is competitive with other analysis.

  • PDF

A Study on the KS standardization of functional corrugated fibreboard (기능성 골판지 포장재 KS규격표준화연구)

  • Lee, Yong-Mu
    • The Monthly Technology and Standards
    • /
    • s.12
    • /
    • pp.67-78
    • /
    • 2003
  • In order to keep a characteristic corrugated fibreboard of fruits and flowers, temperature and humidity change of corrugated fibreboard are analyzed. According to relative humidity rises at fixed temperature, bursting strength of corrugated fibreboard was fallen and double wall corrugated fibreboard appeared greatly the bursting strength decline rate than double faced corrugated fibreboard and edgewise compressive strength of paper more than humidity 80% in rapidly fall. A column crush test of paper became decrease in the high temperature and ordinary temperature strength did over humidity 70% rapidly fallen and strength decrease happened by low temperature 80% slowly fallen and later rapidly. According to ISO standard temperature humidity conditioning (23$\pm$2 , 50$\pm$2%) change, pulp composition difference as to the ring crush strength of a physical strength and generally compare to KS standard increased 5∼8% for the compressive strength, and wet strength reagent was increased 4% inside and out.

  • PDF

Characteristics for the Lift of Wing by 3-D Panel Method (3차원 패널법에 의한 WING의 양력계산에 관한 연구)

  • 김진석;이승건;김진안
    • Journal of Ocean Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.31-37
    • /
    • 1994
  • 3-Dimensional panel method is now developed to the level that one can calculate the lift of a three dimensional body with the same accuracy of wind tunnel test and some current codes can consider the boundary layer effects due to the viscosity and unsteady motion in the calculation of lift. This paper is also aimed to develop these kinds of computing programs, and as a beginning, the authors restricted the problems to the steady potential flow cases. The calculation of 3-Dimensional body, wing and tandem wing carried out, using source panel and vortex ring panel. Finally, the interactions between 3-Dimension symmetric body and a wing are also calculated.

  • PDF

Partial Discharge Property of Hydrogenerator Stator Windings (수력발전기 고정자 권선에서 부분방전 특성)

  • Kim, Hee-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.86-90
    • /
    • 2000
  • Partial discharge(PD) tests were performed when the hydrogenerator(rated 11kV and 25MVA) was shut down(off-line). Six cable couplers were installed in the ring bus as well as within hydrogenerator terminal box. PD tests were conducted using partial discharge analyzer(PDA) and digital partial discharge detector(PDD). PDA showed that the normalized quantity number(NQN) and the partial discharge magnitude increased with increase of ac voltage. Slot discharges were discovered in three phases(A, B and C) at the rated voltage. PDA and PDD test results are in accordance with the pattern and magnitude of partial discharge. This hydrogenerator stator windings were in good condition.

  • PDF