• Title/Summary/Keyword: Rigid splinting

Search Result 5, Processing Time 0.019 seconds

The Effect of Splinting Methods on the Rearrangement of Periodontal Fibers after Tooth Movement in Adult Dogs (치아이동 후 고정방법이 성견 치주인대 섬유의 재배열에 미치는 영향)

  • Lee, Kr-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.27 no.5 s.64
    • /
    • pp.825-837
    • /
    • 1997
  • The purpose of this study was to evaluate the effect of splinting methods on the rearrangement of periodontal fibers after experimental tooth movement. Orthodontic force was applied by placing closed coil spring between upper third incisor and canine in seven dogs, weighing 20 kg or more. After 3 weeks of force application, 0.0215 inch multistrand wire and polyethylene ribbon were bonded to each side, as a flexible and rigid splinting respectively in 6 experimental animals. The remaining one served as a control. Each two animals were sacrificed at 4, 8 and 12 weeks after splinting respectively and prepared histologically for hematoxylin-eosin and Masson's trichrome staining. The results of this study were obtained as follows: 1. After tooth movement, periodontal space was narrowed and periodontal titers were thick on pressure side while elongated fibers were observed on tension side. 2. After 4 weeks of retention, the rearrangement of periodontal fibers was observed in the flexible splinting group, but not in the rigid splinting group. 3. After 8 weeks of retention, the rearrangement of periodontal titers was observed in both groups, but the difference could not be detected between two groups. 4. During the retention period, the rearrangement of periodontal fibers was faster in tension side than in pressure side. These results show that the rearrangement of periodontal fibers is also obtained by rigid splinting after tooth movement. It is suggested that the rigid splinting by polyethylene ribbon can be used as a way of postorthodontic retention.

  • PDF

Flexibility of resin splint systems for traumatized teeth (외상성 치아모형에서의 레진 스플린트 시스템의 유연성 비교연구)

  • Park, Jin-Hong;Shin, Joo-Hee;Ryu, Jae-Jun;Lee, Jeong-Yol;Shin, Sang Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.389-393
    • /
    • 2017
  • Purpose: The aim of this study is to evaluate the flexural strength of flexible resins and the flexibility of different resin splint (RS) systems in comparison with resin wire splint (RWS) system. Materials and methods: Three different resin materials (G-aenial flo, GA, GC; Superbond, SB, Sun medical; G-fix, GF, GC) were tested flexural strength test in accordance with ISO-4049:2000. For the flexibility test of splint systems, a artificial model with resin teeth was used to evaluate three types of resin splint systems (GA, SB, and GF) and one resin wire splint system. The left central incisor was simulated 'injured teeth' with third degree mobility. Three consecutively repeated measurements of periotest value were taken in horizontal direction, before and after splinting to access tooth mobility. The splinting effect was calculated through the periotest value. Differences were evaluated through One-way Anova and Tukey HDS post-hoc tests for pair-wise comparison (${\alpha}=.05$). Results: Although GA group showed significant higher flexural strength than SB and GF groups, all of three different resin splint systems produced a significantly higher and rigid splinting effect compared with 016" resin-wire splint system (P < .05). Conclusion: Within the limits of an in vitro study, it can be stated that resin splint systems are too rigid and may not be acceptable to treat tooth avulsion.

Clinical Appliance of Konus Telescope Denture and Bar-Retained Overdenture on Partially Edenturous Patient (Bar attachment와 Konus telescope를 이용한 부분 무치악 환자의 수복)

  • Choi, Sung-Ho;Shim, Jun-Sung;Lee, Ho-Yong;Lee, Keun-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.2
    • /
    • pp.119-126
    • /
    • 2002
  • The purpose of this study was to restorate a patient who has a few remaining teeth with #15,23,24 supported Konus telescope denture in Maxillar and #44,43,33,34 supported Dolder bar retained overdenture in Mandible. Konus telescope and bar retained overdenture was taken better results in retention, support, stability compair with regular Removable partial denture. In Removable partial denture, the change of remaining teeth and edentulous ridge is natural. But Konus telescope and bar retained overdenture is a little effected in this change, so it is possiblble in long-term use. In cosider of patient's medical history and the possibility of additional tooth loss, Konus telescope denture can be easily repaired. Compaired with Konus telescope and bar retained overdenture showed high stability and easy cleansing because of rigid support, cross - arch splinting, and simple design. In delivery, patient had a difficulty with removal of denture and plaque control, but showed better condition, good oral hygienic care. Patient satisfied with denture functionally and esthetically. This study showed Konus telescope and bar retained overdenture was effective for treatment of patient remaing a few teeth in function, esthetic and psycologic satisfaction.

Implant-supported milled bar overdenture with two implant surgical guides (두 개의 수술용 가이드와 Milled-bar를 이용한 임플란트 피개 의치 수복 증례)

  • Pill-Sang Yun;Sunjai Kim;Se-Wook Pyo;Jae-Seung Chang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.55-62
    • /
    • 2023
  • For fully edentulous patients, implant-supported overdenture can be considered to enhance chewing efficiency and denture stability. Implant planning software can be used to fabricate a surgical guide for a more precise consideration of anatomic factors and prediction of the shape of definitive prosthesis. Though there are many possible attachments for implant overdenture, milled bar can be useful due to its splinting effect of implants and rigid support of overdenture. This report presents a case of implant-supported milled bar overdenture after guided implant surgery performed with two surgical guide that was fabricated before and after bone reduction.

Implants in conjunction with removable partial denture (임플란트를 이용한 국소의치 수복)

  • Kim, Seong-Kyun;Yoo, Soo-Yeon;Park, In-Phil;Lee, Joo-Hee
    • The Journal of the Korean dental association
    • /
    • v.49 no.2
    • /
    • pp.77-84
    • /
    • 2011
  • The benefits of implant supported overdenture are readily apparent for the fully edentulous patients and have been well documented, however, there is deficiency of the studies regarding the combination of implants with removable partial dentures for partially edentulous patients. The purpose of this article is to review the literature concerning implants with removable partial dentures and evaluate the evidence for this clinical approach. Through many clinical case reports and studies we have searched from a broad variety of journals, we present the six considerations needed to contemplate respecting implants with removable partial denture in partially edentulous patients. First, the connection between abutment tooth and removable partial denture has to be rigid and the link between implant and removable partial denture should be hinged. Second, a mesial rest acts better in the point of force distribution for distal extension removable partial denture and splinting between implants is also a favorable choice. Third, T bar has an advantage for implants which are used as abutments in distal extension removable partial denture. Forth, as we all known functional impression is better way to reproduce movement for distal extension removable partial denture. Fifth, indirect retainer and guiding plane on the proximal surfaces of terminal abutment teeth are important in preventing denture base lifting. Sixth, implants in conjunction with removable partial denture is superior in the esthetic and phonetic as well as cost-effective point of view. We also suggest that which place we should install implants for force distribution and which diameter and length of implants should be used. in this review article, we recommend to locate the implant near of the abutment tooth for esthetics or near of first molar position for good stress distribution. The diameter and length of implant also influence to stress distribution. When we compare to conservative partial denture, patients go for removable partial denture using implants due to convenience, better support and retention according to several studies. But it is true that we need to study more on this subject and collect long term follow up cases before we discuss on it. So it is enough to bring this subject into the surface of prosthetic treatment by this article.