• 제목/요약/키워드: Rigid Surface

검색결과 498건 처리시간 0.024초

Fitting accuracy of ceramic veneered Co-Cr crowns produced by different manufacturing processes

  • von Maltzahn, Nadine Freifrau;Bernhard, Florian;Kohorst, Philipp
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권2호
    • /
    • pp.100-106
    • /
    • 2020
  • PURPOSE. The purpose of this in vitro study was to evaluate the fitting accuracy of single crowns made from a novel presintered Co-Cr alloy prepared with a computer-aided design and computer-aided manufacturing (CAD/CAM) technique, as compared with crowns manufactured by other digital and the conventional casting technique. Additionally, the influence of oxide layer on the fitting accuracy of specimens was tested. MATERIALS AND METHODS. A total of 40 test specimens made from Co-Cr alloy were investigated according to the fitting accuracy using a replica technique. Four different methods processing different materials were used for the manufacture of the crown copings (milling of presintered (Ceramill Sintron-group_cer_sin) or rigid alloy (Tizian NEM-group_ti_nem), selective laser melting (Ceramill NPL-group_cer_npl), and casting (Girobond NB-group_gir_nb)). The specimens were adapted to a resin model and the outer surfaces were airborne-particle abraded with aluminum oxide. After the veneering process, the fitting accuracy (absolute marginal discrepancy and internal gap) was evaluated by the replica technique in 2 steps, before removing the oxide layer from the intaglio surface of the crowns, and after removing the layer with aluminum oxide airborne-particle abrasion. Statistical analysis was performed by multifactorial analysis of variance (ANOVA) (α=.05). RESULTS. Mean absolute marginal discrepancy ranged between 20 ㎛ (group_cer_npl for specimens of Ceramill NPL) and 43 ㎛ (group_cer_sin for crowns of Ceramill Sintron) with the oxide layer and between 19 ㎛ and 28 ㎛ without the oxide layer. The internal gap varied between 33 ㎛ (group_ti_nem for test samples of Tizian NEM) and 75 ㎛ (group_gir_nb for the base material Girobond NB) with the oxide layer and between 30 ㎛ and 76 ㎛ without the oxide layer. The absolute marginal discrepancy and the internal gap were significantly influenced by the fabrication method used (P<.05). CONCLUSION. Different manufacturing techniques had a significant influence on the fitting accuracy of single crowns made from Co-Cr alloys. However, all tested crowns showed a clinically acceptable absolute marginal discrepancy and internal gap with and without oxide layer and could be recommended under clinical considerations. Especially, the new system Ceramill Sintron showed acceptable values of fitting accuracy so it can be suggested in routine clinical work.

임플란트를 이용한 국소의치 수복 (Implants in conjunction with removable partial denture)

  • 김성균;유수연;박인필;이주희
    • 대한치과의사협회지
    • /
    • 제49권2호
    • /
    • pp.77-84
    • /
    • 2011
  • The benefits of implant supported overdenture are readily apparent for the fully edentulous patients and have been well documented, however, there is deficiency of the studies regarding the combination of implants with removable partial dentures for partially edentulous patients. The purpose of this article is to review the literature concerning implants with removable partial dentures and evaluate the evidence for this clinical approach. Through many clinical case reports and studies we have searched from a broad variety of journals, we present the six considerations needed to contemplate respecting implants with removable partial denture in partially edentulous patients. First, the connection between abutment tooth and removable partial denture has to be rigid and the link between implant and removable partial denture should be hinged. Second, a mesial rest acts better in the point of force distribution for distal extension removable partial denture and splinting between implants is also a favorable choice. Third, T bar has an advantage for implants which are used as abutments in distal extension removable partial denture. Forth, as we all known functional impression is better way to reproduce movement for distal extension removable partial denture. Fifth, indirect retainer and guiding plane on the proximal surfaces of terminal abutment teeth are important in preventing denture base lifting. Sixth, implants in conjunction with removable partial denture is superior in the esthetic and phonetic as well as cost-effective point of view. We also suggest that which place we should install implants for force distribution and which diameter and length of implants should be used. in this review article, we recommend to locate the implant near of the abutment tooth for esthetics or near of first molar position for good stress distribution. The diameter and length of implant also influence to stress distribution. When we compare to conservative partial denture, patients go for removable partial denture using implants due to convenience, better support and retention according to several studies. But it is true that we need to study more on this subject and collect long term follow up cases before we discuss on it. So it is enough to bring this subject into the surface of prosthetic treatment by this article.

전사공정을 위한 UV 경화성 범프형 스탬프의 점착특성 평가 (Evaluation for Adhesion Characteristics of UV-curable Bump Shape Stamp for Transfer Process)

  • 정연우;김경식;이충우;이재학;김재현;김광섭
    • Tribology and Lubricants
    • /
    • 제32권3호
    • /
    • pp.75-81
    • /
    • 2016
  • Future electronics such as electronic paper and foldable cellphone are required to be flexible and transparent and should have a high performance. In order to fabricate the flexible electronics using flexibility transfer process, techniques for transferring various devices from rigid substrate onto flexible substrate by elastomeric stamp, have been developed. Adhesion between the elastomeric stamp and various devices is crucial for successful transfer process. The adhesion can be controlled by the thickness of the stamp, separation velocity, contact load, and stamp surface treatment. In this study, we fabricated the bump shape stamp consisting of a UV-curable polymer and investigated the effects of curing condition, separation velocity, and contact load on the adhesion characteristics of bumps. The bumps with hemispherical shape were fabricated using a dispensing process, which is one of the ink-jet printing techniques. Curing conditions of the bumps were controlled by the amount of UV irradiation energy. The adhesion characteristics of bumps are evaluated by adhesion test. The results show that the pull-off forces of bumps were increased and decreased as UV irradiation energy increased. For UV irradiation energies of 300 and 500 mJ/cm2, the pull-off forces were increased as the separation velocity increased. The pull-off forces also increased with the increase of contact load. In the case of UV irradiation energy above 600 mJ/cm2, however, the pull-off forces were not changed. Therefore, we believe that the bump shape stamp can be applied to roll-based transfer process and selective transfer process as an elastomeric stamp.

NaOH/THF 공용매 전처리 목질계 바이오매스로부터 레불린산 생산 (Levulinic Acid Production from Lignocellulosic Biomass by co-solvent Pretreatment with NaOH/THF)

  • 이승민;한석준;김준석
    • Korean Chemical Engineering Research
    • /
    • 제61권2호
    • /
    • pp.265-272
    • /
    • 2023
  • 목질계 바이오매스는 조성분간의 결합이 치밀하고 높은 함량의 리그닌을 포함하여 전처리 공정이 필수적이다. 전처리 용매 중 테트라하이드로퓨란(THF)은 유기용매로 재사용이 가능하다는 장점이 있다. THF는 가격이 저렴하고 다양한 반응 조건에서 선택적으로 리그닌을 제거하고 물 혹은 이온성 액체와 공용매로 사용된다. 수산화 나트륨(Sodium hydroxide)은 바이오매스 내 ether결합을 파괴하여 리그닌을 우선적으로 용해시키며 셀룰로오스와 헤미셀룰로오스의 표면적을 확장시키는 역할을 한다. 본 연구에서는 NaOH/THF 공용매 전처리 공정을 적용하여 효과적 리그닌을 제거를 위한 전처리 특성을 파악하고 후속 공정인 산촉매 전환 공정을 통해 최적의 레불린산 전환 수율을 얻었다. 전처리 공정은 NaOH/THF 공용매 비율을 16가지 부피 비율로 수행되었으며 반응조건은 180℃에서 60분으로 고정하였다. 최적의 공용매 조건은 NaOH(5 wt%)/THF 공용매 90:10(v/v%)이였으며 76.8% 글루칸을 수득과 함께 90.1%의 리그닌을 제거하였다. 전처리 후속 공정인 산촉매 전환 공정은 반응시간 30~90분, 반응온도 160~200 ℃로 수행하였을 때, 산촉매 전환 공정의 최적 조건은 180 ℃에서 반응시간 60분이었며, 이 때의 레불린산 전환수율은 84.7%이다.

지오텍스타일 매트의 설치에 의한 개착식 터널 라이닝에 작용하는 토압의 변화 (Variation of Earth Pressure Acting on the Cut-and-Cover Tunnel Lining due to Geotextile Mat Reinforcement)

  • 펄디난드 이 바우티스타;박이근;임종철;주인곤
    • 한국지반공학회논문집
    • /
    • 제23권3호
    • /
    • pp.25-40
    • /
    • 2007
  • 얕은 터널의 개착식 터널 라이닝에 발생하는 과잉토압은 라이닝의 변형과 손상을 유발하는 역학적 주요인자들 중의 하나이며(Kim, 2000), 과잉토압은 되메움토의 다짐불량, 자중에 의한 압밀, 강우의 침투에 의한 다짐, 차량에 의한 진동 등에 의해 발생할 수 있다(Komiya et al., 2000; Taylor et al., 1984; Yoo, 1997). 터널 라이닝에 발생하는 토압을 구하기 위한 많은 시험이 행해졌지만, 부등침하와 과잉토압을 줄일 수 있는 보강대책을 수립하기 위한 사례는 없다. 본 연구는 모래 지반에 $1.0D\sim1.5D$ 깊이에 개착식으로 시공하는 원형의 강성 터널에 작용하는 토압에 관한 것으로 진동다짐의 영향을 모형실험에서 충분히 반영하기 위하여 100Hz의 진동주파수를 사용하였다. 본 연구에서는 개착식 터널 라이링에 작용하는 부등침하와 과잉토압을 줄이기 위해서 지오텍스타일 매트를 설치하였다. 지오텍스타일 매트의 보강에 의한 부등침하와 토압의 감소효과를 확인하기 위해 실내모형실험을 수행하였다. 실내모형실험에서 토피, 매트 보강형태, 절취면의 거칠기 등을 달리하여 가장효과적인 방법을 구하였다. 절취면의 거칠기 달리하기 위해 사면에 사포#100, 사포#400과 acetate 부착하였습니다. 무보강과 매트 보강에 대한 모형실험을 실시하여 구한 토압을 비교하여 매트 보강효과를 살펴보았으며, 사진분석법(Park, 2003)을 이용하여 지반의 변형을 분석하였다.

다양한 첨가제에 따른 고투과성 역삼투막의 특성평가 (Evaluation of the Characteristics of High-Flux Reverse Osmosis Membranes with Various Additives)

  • 권현웅;임광섭;위자야 게데 헤리 아룸;한성민;김성헌;박준호;이동준;엄상민;남상용
    • 멤브레인
    • /
    • 제33권6호
    • /
    • pp.427-438
    • /
    • 2023
  • 본 연구에서는 고투과성 및 높은 염 제거율을 가지는 역삼투막의 성능향상을 위하여 다양한 첨가제 및 계면중합 시 경화 온도 및 시간에 따른 특성평가에 대한 연구가 수행되었다. 첨가제가 없는 막과 첨가제를 첨가한 막의 모폴로지는 모두 "ridge-and-valley" 구조를 나타내어, 폴리아미드 층이 다공성 지지층 표면에 성공적으로 중합되었음을 확인하였다. 또한 2-Ethyl-1,3-hexanediol (EHD) 첨가함으로써 향상된 친수성과 수투과율 가졌으며, 이는 접촉각 측정을 통해서 확인되었다. 최종적으로 97.78%와 98.7%의 NaCl 및 MgSO4 제거율과 3.31 L/(m2⋅h⋅bar)의 높은 수투과율을 가진 고투과성 계면중합막을 제조하였다.

소프트 로봇용 4D 프린팅 소재 (4D Printing Materials for Soft Robots)

  • 이선희
    • 한국의류산업학회지
    • /
    • 제24권6호
    • /
    • pp.667-685
    • /
    • 2022
  • 본 원고는 소프트 로봇용 4D 프린팅 소재와 어그제틱 구조체에 대한 연구 동향을 정리한 것이다. 먼저 4D 프린팅 소재의 형상 변화 거동을 형상 변화와 형상기억 소재, 이중, 삼중, 다중 형상기억 효과, 접힘과 굽힘, 표면지형별로 구분하여 알아보았다. 형상 변화와 형상기억 소재 등 열이나 수분의 자극에 가역적/비가역적 혹은 규칙적/불규칙적 형상 변형이 가능할 수 있다. 다음으로, 차원별 형상이동 유형에 따른 특성과 물성에 대해 알아본 바, 1차원에서 다차원으로의 형상이동을 1D-1D 팽창/수축, 1D-2D 접힘/굽힘, 1D-3D 접힘 (1D-to-3D folding)으로 구분할 수 있다. 2차원에서 형상이동은 2D-2D 굽힙, 2D3D 굽힘/접힘/꼬임/표면말림/표면지형변화/굽힘과 꼬임, 3차원에서 다차원으로의 형상이동은 3D-3D 굽힙과 3D-3D 선형/비선형 거동으로 구분할 수 있다. 마지막으로 4D 프린팅 메타구조체 중 힌지 구조체를 적용한 KinetiX는 단일단위 터셀레이션과 다중단위 터셀레이션으로 모델링할 수 있고, 평면 및 공간 변환이 용이하고, 컨포머블 헬멧에 적용할 수 있다. 키리가미 구조체를 기본으로 한 공압형 어그제틱 구조체는 역설계 기반 구조체로써 굽힘각도를 제어하는 알고리즘으로 설계할 수 있다. 설계 후 3D 프린팅하여 TPU 멤브레인으로 프로토 타입을 제조하였고, 압력을 낮추면서 원하는 3차원 형상으로 완성될 수 있음을 확인하였다. 온도나 습도 등의 외부자극요소에 따라 형상이나 물성을 변화할 수 있는 재료를 사용하여 변형가능한 3차원 구조체로 성형한 4D 프린팅 소재를 이용하여 상지, 하지, 손, 발 등 소프트 로봇의 외골격(exoskeleton) 소재에 적용할 수 있을 것이다. 즉 자세제어, 상황인식, 동작신호 생성 등 다양한 환경에 대응하여 착용자의 움직임에 고하중, 고기동성, 운동지속성을 지원하는 기능을 갖는 소프트 로봇용 4D 프린팅 소재는 헬스케어 웨어러블 의류 제품화 개발로의 용도 전개가 가능할 것이다. 특히 4D 프린팅 소프트 소재 및 공정개발 분야는 일상 생할 보조용이나 재활치료용 의류를 개발하기 위한 3D 프린팅 소재 및 공정의 원천 기술에 해당하므로 이와 관련한 연구의 기초 자료로서 활용되기를 기대한다.

금속, 흡수성 간섭 나사못 및 RIGIDfix를 이용한 전방 십자 인대 재건술의 결과 비교 (Comparison of Results of ACL Reconstruction According to the Fixation Materials (Metal & Bioabsorbable Interference Screw and RIGIDfix))

  • 임홍철;왕준호;노영진;황진호
    • 대한관절경학회지
    • /
    • 제7권2호
    • /
    • pp.206-214
    • /
    • 2003
  • 목적 : 자가 골-슬개건-골을 이용한 관절경적 전방 십자 인대 재건술시 금속성, 흡수성 간섭 나사 및 RIGIDfix를 사용하여 시행한 전방 십자 인대 재건술의 임상 결과를 비교하여 RIGIDfix 의 임상적 유용성과 안정성에 관하여 알아보고자 한다. 대상 및 방법 : 1995년 7월부터 2003년 3월 까지 고려대학교 구로병원을 내원하여 자가 골-슬개건-골을 이용한 관절경적 전방 십자 인대 재건술을 시행받은 133명을 대상으로 하였다. 제1 군은 대퇴터널을 금속성 간섭 나사못을 이용하여 고정한 44명, 제 2군은 흡수성 간 섭나사를 사용한 47명, 제 3군은 RIGIDfix 를 사용한 42명으로 하였다. 세 군 사이의 수술 전 후로 Lysholm score, KT-2000 arthrometer, pivot shift test, anterior drawer test, Lachman test 그리고 방사선학적으로는 터널의 위치 및 크기 증가를 측정하였다. 통계학적으로 SAS 8.2를 이용한 Ducan, Tukey 및 t-test를 사용하여 검증하였다 (p<0.05). 결과 : 이학적 검사상 제 1군은 1례, 제 2군은 4례에서 불안정성을 보여 주었으며, 제 3군의 경우 불안정성을 보여주는 경우는 없었다. Lysholm score는 제1군$\~$3군에서 각 각 수술 전 59.8점, 64.4.점, 61점에서 수술 후 90.1점, 92.3점 92점으로 향상되었으며 차이는 없었다. KT-2000 arthrometer의 경우도 각각 수술 전 평균 $9.20{\pm}11.87 mm$, $10.2{\pm}1.50 mm$, $9.5{\pm}1.53 mm$에서 수술 후 $1.43{\pm}0.87 mm$, $1.62{\pm}0.69 mm$, $2.00{\pm}0.74 mm$ 으로 통계학적 유의성은 없었다 (P=0.478) 일반 방사선상 대퇴 터널의 변화는 흡수성 나사(2군)를 사용한 8례에서 관찰되었으나 이차 자기 공명 촬영상 2군 20례 모두에서 이식물 주변으로의 신호강도 변화를 보여 주었다. 그러나 임상적 결과와의 상관성은 찾을 수 없었다. 결론 : 관절경적 전방 십자 인대 재건술 시 금속성, 흡수성 간섭 나사 및 RIGIDfix 를 이용한 이식건의 고정에 있어서 차이는 없었다. 그러나, 대퇴 터널의 변화에 있어서는 RIGIDfix 군에 비해 금속성 및 흡수성 간섭 나사군에서 더 많이 나타났다. 따라서, 수술 도중 수기의 편함, 시간의 단축과 간섭 나사의 고정 위치, 수술 후 생물학적 반응 및 터널의 이차적 변화 등을 고려할때, RIGIDfix의 사용이 유용하리라 사료되나, 좀 더 많은 추적 기간이 필요하리라 사료된다.

  • PDF