• Title/Summary/Keyword: Right-handed

Search Result 338, Processing Time 0.03 seconds

Using of Scattering Bond Graph Methodology for a Physical Characteristics Analysis of “D-CRLH” Transmission Line

  • Taghouti, Hichem;Jmal, Sabri;Mami, Abdelkader
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.943-950
    • /
    • 2016
  • In this paper, we propose to analyze the physical characteristics of a planar dual-composite right-left handed transmission line by a common application of Bond Graph approach and Scattering formalism (Methodology S.BG). The technique, we propose consists, on the one hand, of modeling of a dual composite right-left metamaterial transmission line (D-CRLH-TL) by Bond Graph approach, and, it consists of extracting the equivalent circuit of this studied structure. On the other hand, it consists to exploiting the scattering parameters (Scattering matrix) of the DCRLH-TL using the methodology which we previously developed since 2009. Finally, the validation of the proposed and used technique is carried out by comparisons between the simulations results with ADS and Maple (or MatLab).

Flexible Zeroth-Order Resonant(ZOR) Antenna Independent of Curvature Diameter (곡률에 독립적인 플렉서블 기판 위에 설계된 영차 공진 안테나)

  • Lim, In-Seop;Chung, Tony J.;Lim, Sung-Joon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.1
    • /
    • pp.21-28
    • /
    • 2012
  • In this paper, we propose a flexible zeroth-order resonant(ZOR) antenna. Its zero phase constant ensures that the antenna performance is independent of substrate deformation. A composite right/left-handed transmission line is designed based on coplanar waveguide technology to realize the zeroth-order resonance phenomenon. The CRLH is an implementation of metamaterial(left handed material) which is composed of shunt inductance and series capacitance. In order to yield additional circuital parameter, chip inductor and gap capacitor is added, respectively. The proposed ZOR antenna provides good performances: reasonable bandwidth(6.5 %) and peak gain(0.69~1.39 dBi). Simulated and measured results show that the antenna's resonant frequencies and radiation patterns are almost unchanged at different curvature diameters of 30, 50, 70 mm, as well as for a flat surface.

Can Right-Handed Surgeons Insert Upper Thoracic Pedicle Screws in much Comfortable Position? Right-Handedness Problem on the Left Side

  • Akyoldas, Goktug;Senturk, Salim;Yaman, Onur;Ozdemir, Nail;Acaroglu, Emre
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.5
    • /
    • pp.568-573
    • /
    • 2018
  • Objective : Thoracic pedicles have special and specific properties. In particular, upper thoracic pedicles are positioned in craniocaudal plane. Therefore, manipulation of thoracic pedicle screws on the left side is difficult for right-handed surgeons. We recommend a new position to insert thoracic pedicle screw that will be much comfortable for spine surgeons. Methods : We retrospectively reviewed 33 patients who underwent upper thoracic pedicle screw instrumentation. In 15 patients, a total of 110 thoracic pedicle screws were inserted to the upper thoracic spine (T1-6) with classical position (anesthesiologist and monitor were placed near to patient's head. Surgeons were standing classically near to patient's body while patients were lying in prone position). In 18 patients, a total of 88 thoracic pedicle screws were inserted to the upper thoracic spine with the new standing position-surgeons stand by the head of the patient and the anesthesia monitor laterally and under patient's belt level. All the operations performed by the same senior spine surgeons with the help of C-arm. Postoperative computed tomography scans were obtained to assess the screw placement. The screw malposition and pedicle wall violations were divided and evaluated separately. Cortical penetration were measured and graded at either : 1-2 mm penetration, 2-4 mm penetration and >4 mm penetration. Results : Total 198 screws were inserted with two different standing positions. Of 198 screws 110 were in the classical positioning group and 88 were in the new positioning group. Incorrect screw placement was found in 33 screws (16.6%). The difference between total screw malposition by both standing positions were found to be statistically significant (p=0.011). The difference between total pedicle wall violations by both standing positions were found to be statistically significant (p=0.003). Conclusion : Right-handedness is a problem during the upper thoracic pedicle screw placement on the left side. Changing the surgeon's position standing near to patient's head could provide a much comfortable position to orient the craniocaudal plane of the thoracic pedicles.

-1 Mode Circular Polarization Antenna Design by Using Cross Aperture-Coupled Feed (십자 개구 결합 급전을 이용한 -1 모드 원형 편파 안테나)

  • Kim, Jun-Sik;Lee, Jeong-Hae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.2
    • /
    • pp.156-163
    • /
    • 2014
  • In this paper, a compact circularly polarized metamaterial patch antenna using cross aperture-coupled feed is proposed. The CP antenna utilizes the -1 mode that is induced by the composit right-left handed(CRLH) transmission line. Since the -1 mode has the same properties with the $TM_{010}$ mode of the conventional patch antenna, the circular polarization(CP) can be realized. If two orthogonal modes are excited with $90^{\circ}$ phase difference, the CP property can be obtained. In order to obtain two orthogonal modes and $90^{\circ}$ phase difference, 4 mushroom structures having the shape of square are employed. The width and length of the cross aperture are optimized through the design algorithm. The fabricated antenna is based on RT/duroid5880 substrate and the total area of the 4 mushroom is $0.25{\lambda}_0{\times}0.25{\lambda}_0$. The center frequency of the LHCP(Left-Handed Circular Polarization) antenna is measured as 1.622 GHz and circular polarization bandwidth(3 dB) is measured as 3 MHz. The center frequency of the RHCP(Right-Handed Circular Polarization) antenna is measured as 1.609 GHz and circular polarization bandwidth (3 dB) is measured as 3 MHz, respectively. The measured radiation efficiency of LHCP antenna is 61.1 % and the measured radiation efficiency of RHCP antenna is 54.5 %.

Fabrication and measurement of RH/LH mode-switchable CRLH transmission line based on silicon RF MEMS switches (실리콘 RF MEMS 스위치 기반의 RH/LH 모드 스위칭이 가능한 CRLH 전송선 제작 및 측정)

  • Hwang, Sung-Hyun;Jang, Tae-Hee;Bang, Yong-Seung;Kim, Jong-Man;Kim, Yong-Kweon;Lim, Sung-Joon;Baek, Chang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1507_1508
    • /
    • 2009
  • This study proposes a composite right/left-handed transmission line (CRLH-TL) that permits switching between the right-handed (RH) and left-handed (LH) modes using single crystalline silicon (SCS) RF MEMS switches. It is possible to change modes from the RH to LH mode, or vice versa, by controlling the admittance of capacitors and the impedance of inductors using switch operations. The proposed switchable CRLH-TL consists of SCS RF MEMS switches, metal-insulator-metal (MIM) capacitors and shunt inductors. At 8 GHz, the fabricated device shows a phase response of $87^{\circ}$ with an insertion loss of 2.7 dB in the LH mode, and a phase response of $-77^{\circ}$ with an insertion loss of 0.56 dB in the RH mode.

  • PDF

Specific Recognition of Unusual DNA Structures by Small Molecules: An Equilibrium Binding Study

  • Suh, Dong-Chul
    • BMB Reports
    • /
    • v.29 no.1
    • /
    • pp.1-10
    • /
    • 1996
  • The binding interaction of ethidium to a series of synthetic deoxyoligonucleotides containing a B-Z junction between left-handed Z-DNA and right-handed B-DNA, was studied. The series of deoxyoligonucleotides was designed so as to vary a dinucleotide step immediately adjacent to a B-Z junction region. Ethidium binds to the right-handed DNA forms and hybrid B-Z forms which contain a B-Z junction, in a highly cooperative manner. In a series of deoxyoligonucleotides, the binding affinity of ethidium with DNA forms which were initially hybrid B-Z forms shows over an order of magnitude higher than that with any other DNA forms, which were entirely in B-form DNA The cooperativity of binding isotherms were described by an allosteric binding model and by a neighbor exclusion model. The binding data were statistically compared for two models. The conformation of allosterically converted DNA forms under binding with ethidium is found to be different from that of the initial B-form DNA as examined by CD spectra. The ratio of the binding constant was interestingly correlated to the free energy of base unstacking and the conformational conversion of the dinucleotide. The more the base stacking of the dinucleotide is unstable, or the harder the conversion of B to A conformation, the higher the ratio of the binding constant of ethidium with the allosterically converted DNA forms and with the initial B-Z hybrid forms. DNA sequence around a B-Z junction region affects the binding affinity of ethidium. The results in this study demonstrate that ethidium could preferentially interact with unusual DNA structures.

  • PDF

Miniaturized UHF WLAN Bandpass Filter Design for Wide Stopband Using the Metamaterial CRLH Structure (메타재질 CRLH 구조를 이용한 넓은 차단 대역을 갖는 UHF WLAN용 소형 대역통과 여파기의 설계)

  • Ju, Jeong-Ho;Kahng, Sung-Tek
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.12
    • /
    • pp.1-7
    • /
    • 2007
  • This paper proposes the design method based on the composite right/left-handed (CRLH) structure to miniaturize and enhance the rejection performance in the stopband. For realization, we used the 0-th order resonance point of the unbalanced case of the CRLH and the simple theory of Inverter. The proposed technique is validated by the performance predictions and experiments, and it is found out that the suggested method enables the sire reduction of over 65 % from the conventional filters such as the parallel coupled type.

Ergonomic Analysis of Cellular Phone Keypad Considering the Dominant Hand

  • Lee, Yong-Bok;Jung, Won-Il;Kim, Dong-Kyu;Kang, Sung-Jin
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.5
    • /
    • pp.621-628
    • /
    • 2011
  • Objective: The aim of this study is to give interest about usability of cellular phone keypad for left-handed person. Background: Although there are being a lot of attempts to design suitable product on user's request in process that design cellular phone keypad, ergonomic access about left-handed person who compose decimal class is unprepared. Especially, in early user's occasion, left-handed persons need more efforts than right-handed person to master Hangul character input process skill level. But, since realization about this left-handed person's discomfort has not spread, the importance has not been well thought in the society. Method: (1) After extracting emblem to use in comparison in questionnaire, applied emblem uniformly to different 3 kind of cellular phone. (2) Measured Hangul input time and mistyping number by dominant hand's position and skill level to reagent. (3) Taking the result through ANOVA. Conclusion: In the result of the experiment about Hangul input time and mistyping number according to dominant hand's position and skill level, left-handed person's group on the low skill level has shown the dullest use capability among 4 experiment groups. Application: In the future, analysis result may be used to the data of realization conversion in process design of various products including cellular phone keypad to consider left-handed person.

The Optimization Method of Symmetrical Building Plan Using Point Group Theory (포인트그룹 이론을 이용한 대칭적 건물 평면형태의 최적대안 결정방안)

  • 진경일
    • Korean Institute of Interior Design Journal
    • /
    • no.38
    • /
    • pp.75-82
    • /
    • 2003
  • The symmetry is general geometric design principal in contemporary architecture shape. But, Symmetry sometimes easily causes unreasonable design. In some reason, two of symmetric units in the apartment, one side of unit have very reasonable plan and arrangement but opposite side unit nay not. For example, if the kitchen on right unit had right-handed arrangement, the symmetrical other would have left-handed kitchen arrangement. In addition to this, if each house unit has the same plan but different direction, each unit has different usage or affects the residents' life pattern. Nevertheless, Architects use only one unit plan to design public housing development by using symmetric operator (mirror, proper rotation, inversion center) at their option. This study suggests that using group theory and mathematical matrix rather than designer's discretion can solve this symmetry problem clearly. And, this study analysis the merits and demerits between each symmetrical pair of unit plan shapes by using mathematical point group theory and matrix.

Development of Impedance Plethysmograph and Measurement of Digital Blood Flow (임피던스 혈류량측정기의 개발 및 손가락 혈류량의 측정)

  • 김덕원;송철규
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.23-28
    • /
    • 1991
  • In this study electrical impedance plethysmograph was developed and each ten digital blood flow was measured for eight nomal males and a patient tvith digital arterial reconstruction surgery. Blood flow of the digit with surgery was approximately fourty percent compared to that of the other normal digit. For the normal subjects, right - handed subjects generally have larger blood flow in right fingers than that in left fingers while it was reverse for the left - handed subjects. The relative average magnitude of the digltal blood flow Is the third, first, second, fourth, and fifth digit in descending order for the left and rich hand, respectively. Blood flow of the fifth digit for all subjec!s except one was the smallest among the five digits.

  • PDF