• 제목/요약/키워드: Ridge Height

검색결과 187건 처리시간 0.023초

석축 산성의 계곡부 체성과 못(池)에 관한 연구 - 거창 거열성과 함안 성산산성을 중심으로 - (A Study on the Wall and Reservoir at the Valley Part of Stone Fortress - Focused on the Fortress of $Geoyeol-seong$ and $Seongsan-seong$ -)

  • 권순강;이호열;박운정
    • 건축역사연구
    • /
    • 제20권3호
    • /
    • pp.7-22
    • /
    • 2011
  • With the accumulations of outcomes from archaeological excavations of mountain fortress of three kingdoms period, there have been studies about time-periodic territory range of mountain fortress, difference in the way(method) of construction, defence system and so on from various points of view. This is an empirical study on the construction method of the valley part of stone fortress. First of all, it is required to secure large quantity of fresh water for those who lived at mountain fortress. Especially when builders of fortress construct a fortification at the valley part of stone fortress, in advance they must sufficiently consider several options including the establishment of sustainable water resources. First, when it comes to build a fortification on a ridge[or a slope] of a mountain, you have only to consider a vertical stress. However, when it comes to build a fortification at the valley part of a mountain, You must have more sufficient preparations for the constructing process. Because there are not only a vertical stress but also a horizontal pressure simultaneously. Second, a fortification of mountain fortress built by using unit building stone is a structure of masonry construction like brick construction, and the valley part of it is where the construction of the fortification begins. Third, when it comes to build a fortification at the valley part of a mountain, it seems that they use a temporary method such as coffer dam in oder to prevent the collapse of the fortification due to heavy rain. Furthermore, in response to a horizontal pressure a fortification is built by the way of its plane make an arch, or by piling up the soil with the plate method(類似版築) and earthen wall harder method(敷葉) they increase cross-sectional area of the fortification and its cutoff capacity. In front direction they put the reservoir facility for the fear that the hydraulic pressure and earth pressure are directly transmitted to the fortification. The process of constructing the fortification at the valley part of a mountain is done in the same oder as follows; leveling of ground(整地) ${\Rightarrow}$ construction of coffer dam ${\Rightarrow}$ construction of the fortification between the both banks of the valley ${\Rightarrow}$ construction of the fortification at bottom part of spill way(餘水路) between the both banks of the valley ${\Rightarrow}$ construction of spill way(餘水路) & reservoir facility ${\Rightarrow}$ construction of the fortification at upper part of spill way between the both banks of the valley. Coffer dam facility seems to be not only the protection device on occasion of flood but also an important criterion to measure the proper height of spill way or tailrace(放水路). This study has a meaningful significance in that it empirically examines the method of reduction of the horizontal pressure which the fortification at the valley part of a mountain takes, the date the construction was done, and wether the changes in climate such as heavy rainfall influence the process of construction.

경운성능(耕耘性能) 향상(向上)을 위한 쟁기 이체(犂體)의 적정(適正) 설계(設計)에 관(關)한 연구(硏究) -쟁기 이체곡면(犂體曲面)의 기하학적(幾何學的) 특성(特性)- (Optimum Design of Jaenggi(Korean plow) Bottoms to Improve the Tillage Performance(I) -The Geometrical Characteristics of the Jaenggi Bottoms-)

  • 정창주;한명범
    • Journal of Biosystems Engineering
    • /
    • 제12권3호
    • /
    • pp.30-41
    • /
    • 1987
  • The geometrical shape of a plow bottom may be the most important factor affecting the performance of a plow for a given soil and operating conditions. There are various designs of the Jaenggi (Korean plow) available commercially, which may be different from each other and from the plow (Western plow) in respect to the shape and performance. This study was intended to investigate the geometrical characteristics of Jaenggi. The coordinate digitizer equipped with 3 potentiometers was designed and manufactured for measurement of the shape of curved plane of moldboard and share. The digitizer was connected to a microcomputer having the data acquisition system. This device was used to analyze the plow bottoms of 5 differently-made Jaenggis and one cylindrical plow. The results of the study are summarized as follows: 1. It was possible to measure easily and quickly the curved plane of plow bottom and to plot the view on three major plans using the coordinate digitizer electrically connected to a microcomputer system. 2. The shape of five Jaenggi bottoms analyzed could be characterized by the cutting angle having the range of $33-42^{\circ}$, the maximum share-lift angle of $41-50^{\circ}$, and the setting angle of moldboard wing of $46-70^{\circ}$. The most critical difference of the shape factors between the Jaenggi and the plow was found in the maximum share-lift angle, the former was more than twice as much as the latter. 3. The analysis of the shape of Jaenggi bottoms showed that the share projections on 3 major plans had a varied triangle, which was quite different from that of plow bottom. Especially, it was analyzed that the shape of furrow slice for the Jaenggi had a skewed rectangle, leaving a considerable height of the ridge at the furrow bottom. 4. The dihedral angle was similar range of $30-85^{\circ}$ for the all bodies investigated, but the directional angle was somewhat different from each other. The difference in directional angle was $5^{\circ}$ for the plow, $20^{\circ}$ for the Jaenggi A and $30^{\circ}$ for the Jaenggi B. 5. Area of the spherical representation region was 0.0328 for the plow, 0.1194 for the Jaenggi A and 0.1716 for the Jaenggi B. This may indicate that the plow came close to a working surface and the Jaenggi A and the Jaenggi B departed from a working surface to a somewhat greater extent.

  • PDF

II급 와동에서 각종 구치용 수복물의 파절강도에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON THE FRACTURE STRENGTH OF CLASS II POSTERIOR RESTORATIONS)

  • 이계혁;허승면;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제18권2호
    • /
    • pp.357-367
    • /
    • 1993
  • The purpose of this study was to evaluate the fracture strength of class II restored premolars with amalgam, posterior composite, amalgam - Ketac silver, resin - Ketac silver restorations at marginal ridge. Fifty extacted maxillary and mandibular premolar teeth that were caries free, fracture free, and restoration free were selected and randomly divided into five groups : Group 1 : 10 intact teeth, Group 2 : 10 teeth with class II cavities and restored with, amalgam, Group 3: 10 teeth with class II cavities and restored with posterior resin, Group 4 : 10 teeth with class II cavities and restored with amalgam - ketac silver, Group 5 : 10 teeth with class II cavities and restored with resin - Ketac silver. All teeth were mounted in base of dental stone within metal rings of 2cm diameter, exposing only the crown portion. Class II mesio - occlusal or disto - occlusal cavities were prepared into specimens of Group 2 through 5 by using a No. 710 fissure bur. The occlusal portion was prepared to a faciolingual width of 1.5mm and a pulpal depth of 1.5mm. The proximal protion was prepared to a faciolingual width of 4mm, a occlusogingival height of 4mm, and a gingival floor of 1.5mm. The teeth in Group 2 and 3 were resotored with silver amalgam apd posterior resin respectively. In Group 4 and 5, proximal portions were first filled with Ketac silver 1.5mm gingivally and remaining cavities were restored with amalgam and posterior resin respectively. All specimens were stored in 100 % relative humidity at $37^{\circ}C$ for 48 hours before testing. All teeth were subjected to a compressive load in a Universal Instron Testing Machine at marginal ridges. The loads required to fracture the restorations were recorded in killograms and the data obtained were subjected to statisticall analysis. The results were all follows : 1. The fracture strength of Group 1 which were unprepared were $100{\pm}10.1\;kg$ and the higher values than Group 2, 3, 4, 5 which were prepared and resotred. 2. In restored groups, Group 2 had the higher fracture strength($81.8{\pm}12.4\;kg$) than other groups and Group 4 had the lowest fracture strength($66.8{\pm}9.2kg$). 3. There were significant differences between fracture strength of between Group 1 and Group 3, 4, 5(P<0.05), but not significant difference between fracture strength of Group 2, 3, 4, 5(P>0.05).

  • PDF

측방 접근법에 의한 상악동 거상술을 이용하여 식립된 골내 임플란트의 10년간 후향적 연구 (Long-term evaluation of implant placed in sites grafed by lateral window approach on maxillary sinus;a 10-year retrospective study)

  • 연제영;채경준;정의원;김창성;최성호;조규성;김종관;채중규
    • Journal of Periodontal and Implant Science
    • /
    • 제37권4호
    • /
    • pp.691-704
    • /
    • 2007
  • Between 1997 May and 2007 May, One hundred and seventeen patients were treated. There were 129 cases of sinus elevation using a lateral window opening procedure and 258 implants placed simultaneously or delayed. The cumulative survival rate of the implants calculated. The implants were evaluated according to surgical site, quality and quantity of bone, graft material, membrane used, the length and diameter of the implant and complications. 1. The 10-year cumulative survival rate of the implants by sinus augmentation using lateral window approach was 96.90%. 2. There was no difference in the survival rate between the implant placed simultaneously with sinus elevation (one stage) and the procedure performed in the delayed procedure (two stage). 3. There was no difference in the survival rate according to the type and amount of graft materials. 4. There was no difference in the survival rate according to the implant site, bone quality and quantity. 5. There was no difference in the survival rate when the $CollaTape^{(R)}$ or Gore-Tex was placed in the window of the lateral wall. 6. There was no difference in the survival rate of the implant length and diameter. 7. The survival rate was as low as 75.00% when there were more than two complications. Implant placement with sinus augmentation using the lateral window approach is a predictable treatment method. Although the vertical height of residual ridge is insufficient and the quality of bone is poor, the normal survival rate of the implants would be expected if an appropriate graft material and membrane is used with greater effort to prevent complications.

PGA 투어의 골프 스코어 예측 및 분석 (Prediction of golf scores on the PGA tour using statistical models)

  • 임정은;임영인;송종우
    • 응용통계연구
    • /
    • 제30권1호
    • /
    • pp.41-55
    • /
    • 2017
  • 최근 골프는 많은 사람들의 취미 생활로서 자리를 잡아가고 있으며 골프와 관련된 연구도 다양하게 이루어지고 있다. 본 연구에서는 데이터 마이닝 기법을 사용하여 PGA 투어에 참여하는 선수들의 평균스코어를 예측하고 스코어에 유의한 영향을 미치는 변수들을 제시하고자 한다. 그리고 추가적으로 4개의 PGA 투어 플레이오프에 대해 상위 10명, 상위 25명의 선수들을 예측하는 것을 목표로 한다. 우리는 다양한 선형/비선형 회귀분석 방법을 이용하여 평균스코어를 예측하는데, 선형회귀분석 방법으로는 단계적 선택법, 모든 가능한 회귀모형, 라소(LASSO), 능형회귀, 주성분회귀분석을 사용하였으며 비선형회귀분석 방법으로는 트리(CART), 배깅, 그래디언트 부스팅, 신경망 모형, 랜덤 포레스트, 최근접이웃방법(KNN)을 사용하였다. 대부분의 모형에서 공통적으로 선택된 변수들을 살펴보면 페어웨이의 단단함와 그린의 풀의 높이, 평균최대풍속이 높을수록 선수들의 평균스코어는 높아지며 반대로 한 번에 퍼팅을 성공시키는 횟수와 그린적중률 실패 후 버디나 이글로 점수를 만드는 scrambling 변수들, 그리고 공을 멀리 보낼 수 있는 능력을 나타내는 longest drive는 그 값이 높아짐에 따라 선수들의 평균스코어가 낮아지는 경향이 있음을 알 수 있었다. 11가지 모형 모두 테스트 데이터인 2015년 경기 결과를 예측하는데 낮은 오류율을 보였으나 배깅과 랜덤 포레스트의 예측률이 가장 좋았으며 두 모형 모두 상위 10명과 상위 25명의 랭킹을 예측할 때 상당히 높은 적중률을 보였다.

중국 청대(淸代) 황가능침원(皇家陵寢園)의 조형 및 경관적 특성 (A Study on the Formation and Landscape Characteristics of Imperial Tombs Created in the Qing Dynasty, China)

  • 노재현;위항
    • 헤리티지:역사와 과학
    • /
    • 제55권1호
    • /
    • pp.5-34
    • /
    • 2022
  • 본 연구는 청대 황가능침원 12기를 대상으로 입지와 풍수 그리고 형태와 구조 등이 어우러진 시설 배치상의 특징을 고찰함으로써 청대 황가능침원 고유의 조영 경관적 특성을 구명하고자 한 것이다. 문헌조사와 현장 관찰 및 인터뷰, 영상 및 도면 비교 그리고 귀납 대비적 분석을 통해 청나라 시대 황가능침원의 조영 경관 특성을 자연환경, 입지 및 풍수 형세, 조영 형태와 구조로 구분하여 분석하였다. 그 결과 풍수 형국, 중축선에 따른 축선 연장거리, 능침 폭, 기점과 종점의 고저의 차에 따른 시설배치의 정형성, 능침의 좌향, 진입공간-제향공간-능침공간의 공간 비율 등의 분석에 따라 청대 황가능침원의 입지형국과 배치 계획상의 특성을 도출하였다. 또한 능침 시설물의 종류와 배치 순서 그리고 석상생의 분포 및 수량 및 종류 분석을 통해 능침의 시설배치적 특성을 도출하는 한편 명나라 시대와 다른 몇 가지 조영 특성을 밝힐 수 있었다. 또한 수계를 통한 공간분할 효과, 중축선에서의 광경(框景)과 협경(夾景)의 조망 효과가 소밀대비(疏密對比)와 함께 청대 황가능침원에서 발견되는 대표적 조망경관 효과임을 확인하였다.

바람길 조성을 위한 도시공간유형별 찬공기 유동 특성 분석 - 창원시 도시지역을 중심으로 - (Analysis of Cold Air Flow Characteristics according to Urban Spatial Types to Construct a Wind Road - Focused on Urban Area of Changwon -)

  • 이수아;송봉근;박경훈
    • 한국지리정보학회지
    • /
    • 제25권2호
    • /
    • pp.30-47
    • /
    • 2022
  • 본 연구는 경상남도 창원시 도시지역을 대상으로 공간유형에 따른 찬공기 유동 특성을 분석하였다. 공간유형은 창원시 도시생태현황지도의 토지이용현황도와 건물 정보, 지형 특성을 활용하여 군집분석을 통해 분류하였다. 찬공기 유동은 KLAM_21 모델링을 활용하여 시간의 경과에 따른 찬공기 양과 풍속으로 분석하였다. 그 결과, 공간유형은 건물의 밀집도와 높이, 토지이용 유형, 그리고 지형 특성인 평지, 계곡, 능선, 경사지가 고려되어 총 14개 유형으로 분류되었다. 찬공기 유동은 도시 외곽의 산림지역 계곡부에서 찬공기가 생성되어 도로와 평지를 통해 이동하여 저지대인 창원국가산업단지에 축적되기 시작하고, 이후 도시지역 전반에 찬공기가 확산되는 것으로 나타났다. 건물이 높은 지역은 찬공기의 유동이 많았고, 경사지와 능선부는 찬공기 축적이 적어 유동량이 상대적으로 작았다. 본 연구결과는 건물 밀집도와 토지이용 유형, 지형 형태에 따른 찬공기 유동 특성 파악이 가능하였고, 이는 도시지역의 기후 완화 및 대기질 개선을 위한 도시 바람길 조성의 기초자료로 유용하게 활용될 것이다.

벼 수확전 파종 보리의 생육과 수량성 (Growth and Yield of Barley Broadcasted before Rice Harvest)

  • 주정일;김칠현;문창식;김창영;조장환
    • 한국작물학회지
    • /
    • 제40권4호
    • /
    • pp.428-436
    • /
    • 1995
  • 벼 수확과 맥류파종간에 노동력 및 농기계에 대한 경합을 분산하면서 무경운에 의한 파종작업의 조방화로 성력효과를 기하고자 벼 수확전 입모중에 맥류 종자를 전면 산파하고 벼 수확시 볏짚으로 맥류종자를 피복되게 하는 파종법을 트렉터부착 줄뿌림 파종기에 대한 휴입세조파 방법과 비교하였다. 파종방법간 비교시험은 올보리를 공시하여 1990~1994년 4사맥작기간 동안 대전에서 실시하였다. 또한 입모중 파종기 시험으로 벼 수확전 1일, 5일, 10일, 15일에 파종한 후 파종기 차이에 따른 생육 및 수량반응을 1992~1994년까지 2작기 동안 조사하였는 바 그 결과는 다음과 같다. 1. 벼 입모중 보리 산파는 세조파에 비하여 월동전후 초장이 길고 분얼수가 많았으나 월동후 고엽율은 평균 17.4% 높았다. 2. 지상부 생육은 세숙파에 비하여 입모중 파종에서 저조하였고, 출수기와 성숙기는 두 파종방법간 비슷하였다. 3. 수량은 입모중 파종에서 평균 364 kg / 10a로 세조파 파종에 비하여 평균 20.6% 감소하였고 이는 주로 m$^2$ 당 이삭수 및 1수입수의 감소에 기인하였다. 4. 벼 수확전 파종일에 따른 보리의 생육 및 수량성은 유의성이 없었다. 5. 입모중 파종이 세조파 파종에 비하여 생육, 수량구성요소 및 수량의 연차간 변의가 높았다.

  • PDF

3차원 스캐너를 이용한 상악 제1유구치 치관의 크기와 형태에 관한 연구 (A MORPHOMETRIC STUDY OF THE MAXILLARY PRIMARY FIRST MOLARS USING THREE-DIMENSIONAL SCANNER)

  • 이종범;김종철;한세현;이상훈
    • 대한소아치과학회지
    • /
    • 제33권4호
    • /
    • pp.643-652
    • /
    • 2006
  • 본 연구의 목적은 상악 제1유구치 치관의 크기와 형태적 특성을 3차원 스캐너를 미용하여 계측하고 국정 금속관과의 크기와 형태학적인 차이를 비교하는 것이다. 3차원 레이저 스캐너(Breuckmann opto Tep-HE100, INUS. Korea)로 스캔한 132aud 어린이들의 상악 제1유구치 경석고 모형을 Rapidform 2004 프로그램(INUS, Korea)을 이용하여 각 치아의 근원심경과 협설경, 교합면-치경부간 거리, 근원심경에 대한 협설경의 비율을 계측하고 평균치를 얻었으며, 남녀 상악 제1유구치의 평균적인 크기와 형태를 얻고 기성 금속관과 비교하여 다음과 같은 결과를 얻었다. 1. 상악 제1유구치 디관의 좌우측 크기에 있어서 유의한 차이를 보이지 않았다(p<0.05). 2. 상악 제1유구치 치관의 남녀간 크기에 있어서 남자의 치관 크기가 유의하게 더 큰 값을 보였고(p<0.05), 치관의 형태에 유의한 치이는 보이지 않았다(p>0.05). 3. 3차원 이미지로 상악 제1유구치를 재구성하여 나타낸 평균적인 남녀 상악 제1유구치의 크기는 3M의 기성 금속관과 비교 시, 남자는 기성 금속관의 4, 5번 사이, 여자는 기성 금속관의 4번과 유사하였고, 일성의 기성 금속관과 비교 시 기성 금속관의 근원심경이 커서 협설경을 기준으로 남자는 5번, 여자는 4번과 유사한 크기를 보였다. 4. 3M의 기성 금속관에 비해 재구성한 평균치의 치관 형태가 근심 설측 우각 부위, 원심 설측 우각 부위에서 더 풍융하였고, 협측 치은 융기의 치경부 1/3부위가 더 풍융한 양상을 보였으며, 남자의 치관보다 더 풍융한 양상을 보였다. 일성의 기성 금속관은 평균치의 치관 형태보다 정사각형의 형태를 나타냈고, 근원심경이 더 긴 양상을 나타냈다.하악 유견치의 치근 흡수의 완료는 하악 제 1 유구치 보다 빨랐으며, 하악 유견치에서 치근 흡수에 소요된 총 기간은 가장 짧았다. 5. 치근 흡수의 속도는 흡수 말기가 초기에 비해 빠른 경향을 나타냈다. 정확한 유치 치근의 흡수시기에 대해 알기 위해서는 정기적이면서 종적인 연구가 필요하리라 생각한다.ture model index(SMI), degree of anisotropy (DA)는 두 군 사이에 유의한 차이를 보이지 않았다(p>0.05). 4. 조직 절편을 관찰한 결과, 부드러운 사료를 먹인 실험군에서 하악 과두의 연골층의 증식 층과 전체 두께가 상당히 감소하였다.항성에 있어 유의한 차이를 보이지 않았다. 8379, 근심면 평균 0.8223, 설면 평균 0.7766, 원심면 평균 0.6781 순으로 나타났다. 4. 치아 우식증 진단율을 비교한 결과 교합면, 협면, 설면에서는 $DIFOTI^{TM}$ 이미지 판독이 가장 우수한 것으로 나타났으며(p<0.05), 근심면과 원심면에서는 방사선 판독이 가장 우수한 것으로 나타났다(p<0.05).는 P=0.009로 나타났다. 임상생징후 변화는 유의성이 없었다. 4. 종양환자의 검사치간의 시기별에 따른 상관관계를 조사한 결과 유의확률이 0.05 이하인 수치들은 Hb과 Albumin, K, Na간, Neutrophil과 Leukocyte간이었고 상관계 수치는 $0.370{\sim}0.442$ 사이로 나타났다. 유의확률 0.01이하로 조사된 수치는 Cholesterol과 ALT간, LDH와 Platelet, Creatinine간, Platelet와 BUN간, Na와 K수치간 이었으며 상관계수는 $0.531{\sim}0.866$사이로 나타났다.

  • PDF

단동온실 내 공기순환팬 사용에 따른 온습도 및 에너지소비량 비교 분석 (Analysis of Air Temperature and Humidity Distributions and Energy Consumptions according to Use of Air Circulation Fans in a Single-span Greenhouse)

  • 이태석;강금춘;김형권;문종필;오성식;권진경
    • 생물환경조절학회지
    • /
    • 제26권4호
    • /
    • pp.276-282
    • /
    • 2017
  • 본 연구는 방울토마토 재배 단동온실에 공기순환팬을 설치하고 공기순환팬이 온실 내 온도 및 습도 분포, 에너지소비량에 미치는 영향을 분석하였다. 공기순환팬은 날개 크기 230mm의 Stainless 팬으로, Lee 등(2016)의 연구결과를 참고하여 시험구 온실에 9m 간격으로 총 18대를 설치하였다. 온실 내부 온습도는 온실 길이방향으로 4등분하여 1/4 지점과 3/4 지점의 중앙에 센서를 설치하고 0.8m, 1.8m 높이 2곳의 온습도를 난방을 주로 하는 야간(오후 6시~다음 날 오전 7시)에 5분 간격으로 측정하였다. 에너지소비량은 각 온실에 위치한 온수펌프의 유량, 온수 출수부와 환수부의 온도차를 측정하여 계산하였다. 공기순환팬을 사용하지 않았을 때 측점 간 온도차 및 습도차의 평균값은 $0.75^{\circ}C$, 2.19%였으며 공기순환팬 사용 시 측점 간 온도차 및 습도차의 평균값은 $0.42^{\circ}C$, 1.27%로 감소하였다. 공기순환팬 설치 온실과 미설치 온실의 누적 에너지소비량은 각각 4,673kWh, 4,009kWh로 공기순환팬 설치 온실에서 약 14.2%의 에너지를 적게 소모하였다. 이러한 결과로 보아 온실 내 공기순환팬 사용은 공기를 지속적으로 교반시켜 주어 온실 전체의 온도 및 습도를 균일하게 만들고, 공기의 온도가 빠르게 변하지 않도록 해주어 난방 장치의 가동 시간과 에너지소비량을 줄일 수 있다.