• 제목/요약/키워드: Rib thickness

검색결과 217건 처리시간 0.026초

윙립 두께 측정용 비접촉식 검사 시스템에 관한 실험적 연구 (Experimental Study on Non-contact Type Inspection System for Wing Rib Thickness Measurement)

  • 이인수;김해지;안명섭
    • 한국기계가공학회지
    • /
    • 제13권6호
    • /
    • pp.104-110
    • /
    • 2014
  • This paper presents a non-contact inspection system for automatically measuring the thickness of an aircraft wing rip product. In order to conduct the inspection of the wing rib thickness automatically, a non-contact laser displacement sensor, end-effector, and a robot were selected for use. The non-contact type inspection system was evaluated by measuring the measurement deviation of the rotation direction of a C-type yoke end-effector and the transfer direction of a V-slim end-effector. In addition, the non-contact inspection system for wing rib thickness measurements was validated through thickness measurements of a web, flange, and stiffener.

강바닥판 피로손상 원인규명 및 피로성능 개선에 관한 해석적 연구 (The Analytical Study on the Cause of Fatigue Damage and the Improvement of Fatigue Performance for Orthotropic Steel Deck)

  • 경갑수;신동호;김교훈
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.647-654
    • /
    • 2006
  • In orthotropic steel decks, it is likely to have defects due to fatigue damages because most of structural joints(the connection of longitudinal rib and transverse rib, the connection of deck plate and longitudinal rib) are connected by welds. However. orthotropic steel decks have many advantages. such as light weight and reduction of construction time. in comparison with concrete decks. Therefore. they are mostly used in long-span bridges and urban highway bridges. This study consists of the cause identication of fatigue damage and the suggestion of rational thickness on deck plate about the connection of deck plate and longitudinal rib. The results are as follows: fatigue damage cause at the connection of deck plate and longitudinal rib is local deformation in deck plate. And, rational thickness of deck plate is 16mm thickness.

  • PDF

근사 모델과 NSGA-II를 이용한 진공청소기 손잡이 근사최적설계 (Optimization of Vacuum Cleaner Handle Using Approximate Model and NSGA-II)

  • 윤민노;이종수
    • 한국생산제조학회지
    • /
    • 제26권1호
    • /
    • pp.30-35
    • /
    • 2017
  • The major parts of a vacuum cleaner are molded. The vacuum cleaner works in multi-load conditions. Therefore, the designer needs to optimize the structure and injection molding conditions simultaneously. Here, the main factor of design is the rib shape and thickness. The greater the rib thickness, the greater the stiffness of the structure. However, it causes an increase in weight. On the other hand, the lower the rib thickness, the greater the increase in the injection pressure. However, the weight will be reduced. Therefore, the designer needs to optimize the rib shape and thickness for structure stiffness and injection molding. In order to solve this problem, we propose an optimization method using D.O.E and a response surface model, which is a multi-objective optimization method using the multi-objective genetic algorithm.

AC PDP의 addressing time과 유전체 및 Barrier Rib 높이와의 상관관계 (The relationship between addressing time and dielectric layer, barrier rib hight)

  • 박정태;박차수;송기동;박정후;조정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1824-1826
    • /
    • 2000
  • Up to date, the dual scanning method has been adopted to decrease address-ing period in AC PDP. In this case, addressing period can be reduced, but the driving circuit cost should be increased. In this study, to increase addressing speed we have studied the relationship between addressing speed and cell structure. That is to say, we varied the thickness of dielectric layer on the front glass, the thickness of white back and the height of barrier rib on the rear glass. So, we found that the addressing time was decreased 4% with decreasing 5um thickness of dielectric layer on the front glass and 2um thickness of white back on the rear glass. Also in case of decreasing the height of barrier rib, addressing time was decreased about 4% per 10um.

  • PDF

T형 다조부품의 결함에 관한 연구 (A Study on the Defect of T type Forging Products)

  • 손경호;김영호;서윤수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.952-956
    • /
    • 1997
  • This paper describes the method that can expand the forming limit of T type forging products used in aircraft and automotive forged products. The forming limitis determined by the ratio of web thickness to rib width in T type and the reduction in height of workpiece and especially depends on the ratio of web thickness to rib width. For this method, the geometric condition that consists of triangle type was introduced and FEM simulations and model exoeriments were carried out and compared with each other. The objective of this paper is to give the method not only that sink mark and folding phenomenon are eliminated but also that the forming limit and the structural strength of rib and web is increased.

  • PDF

IPMSM의 Hole에 의한 Rib의 두께 감소와 전자기적 성능 향상 (Electromagnetic Performance improvement and Rib thickness Reduction by making a hole on Interior Permanent Magnet Synchronous Motor)

  • 이태근;김도진;홍정표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.867_868
    • /
    • 2009
  • Interior permanent magnet synchronous motor [IPMSM] which has high power density is applied to motor for Hybrid electric vehicle[HEV], Electric vehicle[EV], Fuel cell electric vehicle[FCEV] and electric home appliances. In order to improve efficiency performance of IPMSM, this paper presented a study by making a hole around air barrier. Because concentrated rib stress is distributed by suitable hole, the hole can reduce rib thickness of IPM rotor. And it can help decrease PM[Permanent Magnet] leakage flux. Saliency ratio($L_q/L_d$) is also increased by magnetic circuit change. For this study, structure analysis of rotor is performed by Ansys program.

  • PDF

AC PDP의 유전체 두께와 격벽 높이에 따른 Addressing Time (The Effect of Dielectric Thickness and Barrier Rib Height on Addressing Time of Coplanar AC PDP)

  • 신중홍;박정후
    • 한국전기전자재료학회논문지
    • /
    • 제15권12호
    • /
    • pp.1065-1069
    • /
    • 2002
  • The addressing time should be reduced by modifying cell structure and/or driving method in order to replace the dual scan system by single scan and increase the luminance in large ac plasma display panel(PDP). In this paper, the effects of the addressing time was decreased with decreasing thickness of dielectric layer on the front glass and thickness of white dielectric layer on the rear glass. the decreasing rate were 160ns/10$\mu\textrm{m}$ and 270ns/10$\mu\textrm{m}$, respectively Also in case of decreasing the height of barrier rib, addressing time was decreased at the rate of Sons/10$\mu\textrm{m}$.

니트의 편성조직에 따른 물성 평가 (Physical Properties of Various Structured Knitted Fabrics)

  • 예수정;송화순
    • 한국의류산업학회지
    • /
    • 제13권6호
    • /
    • pp.990-995
    • /
    • 2011
  • This study analyzed the effects of the knit stitch type, fiber composition, and yarn thickness on the mechanical properties of knitted fabric. The results were as follows: The course density was the highest in the case of the rib stitch. On the other hand, the wale density was the highest in the case of the float stitch. The thickness was the highest in the case of the rib stitch. The same results were obtained even for different fiber compositions and yarn thicknesses considered in this study. The burst strength of wool knit fabric was higher than that of A/W knit fabric. The stiffness was the lowest in the case of the plain stitch. The same results were obtained even for different fiber compositions and yarn thicknesses. The pilling properties were excellent for all knit stitches, fiber composition, and yarn thicknesses as pilling degree : 5. The air permeability decreased in the following order : rib > plain > float stitch. The same results were obtained even for different fiber compositions and yarn thicknesses. The heat retention rate decreased in the following order : rib > float > plain stitch. The same results were obtained even for different fiber compositions and yarn thicknesses.

The Optimum Phosphor Thickness to Obtain the Highest Luminance and Luminous Efficiency in ac PDP

  • Heo, Jeong-Eun;Kim, Young-Kee;Park, Hun-Gun;Park, Chung-Hoo
    • Journal of Information Display
    • /
    • 제2권1호
    • /
    • pp.14-19
    • /
    • 2001
  • Plasma display panel(PDP) have gained great attention due to their potential application to large-area display including HDTV. The luminance and luminous efficiency of PDP, however, should be improved to realize this goal. In this study, we examined experimentally the effects of phosphor thickness and discharge gap on the luminance and luminous efficiency of ac PDP. For the rib height of 110 ${\mu}m$, whereas the optimum phosphor thickness was about 30 ${\mu}m$. The optimum thickness of green phosphor was about 50 ${\mu}m$ for the rib height of $120{\sim}160\;{\mu}m$.

  • PDF

임플랜트 고정체의 형태가 임플랜트 초기안정성에 미치는 영향 (INFLUENCE OF IMPLANT FIXTURE DESIGN ON IMPLANT PRIMARY STABILITY)

  • 오갑용;박성화;김석규
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.98-106
    • /
    • 2007
  • Statement of problem: Current tendencies of the implant macrodesign are tapered shapes for improved primary stability, but there are lack of studies regarding the relationship between the implant macrodesign and primary stability. Purpose: The purpose is to investigate the effect of implant macrodesign on the implant primary stability by way of resonance frequency analysis in the bovine rib bones with different kinds of quality. Material and method: Fifty implants of 6 different kinds from two Korean implant systems were used for the test. Bovine rib bones were cut into one hundred pieces with the length of 5 cm. Among them forty pieces of rib bones with similar qualities were again selected. For the experimental group 1, the thickness of cortical part was measured and 20 pieces of rib bones with the mean thickness of 1.0mm were selected for implant placement. For the experimental group 2, the cortical parts of the remaining 20 pieces of rib bones were totally removed and then implants were placed on the pure cancellous bone according to the surgical manual. After placement of all implants, the implant stability quotient(ISQ) was measured by three times, and its statistical analysis was done. Results: There are statistically significant differences in ISQ values among 4 different kinds of Avana system implants in the experimental group 2. For the experimental group 1, Avana system implants showed significantly different ISQ values, but when differences in the thickness of cortical parts were statistically considered, did not show any significant differences in ISQ values. Among Oneplant system implants, there are no significant differences in ISQ values for the experimental group 2 as well as for the experimental group 1. Conclusion: Within the limits of this study, bone quality and implant design have some influences on the primary stability of implants. Especially in the bone of poor quality, tapered shape of implants are more favorable for the primary stability of implants.