• Title/Summary/Keyword: Rib plate

Search Result 148, Processing Time 0.026 seconds

An Experimental Study on Load Bearing Capacity of Lattice Girder as a Steel Support in Tunnelling (터널 지보재로서 격자지보의 하중지지력에 관한 실험적 연구)

  • 유충식;배규진
    • Geotechnical Engineering
    • /
    • v.13 no.4
    • /
    • pp.163-176
    • /
    • 1997
  • It has long been recognized that the H-beam steel rib has many shortcomings when used as a steel support in tunneling. One of the major shortcomings is the shotcrete shadow created behind H-beam flange which eventually reduces the load bearing capacity of shotcrete shell. In many European countries, plate girder as the H-beam steel rib has been replaced by lattice girder which has many advantages over the H-beam steel rib. Successful application of the lattice girder as a steel support requires a thorough investigation on the load bearing capacity of the lattice girder. Therefore, laboratory bending and compression tests were conducted on lattice girders with the aim of investigating the load bearing capacity of the lattice girders. The results of tests show that the load bearing capacity of laIn twice girders is higher than that of H-beams, which indicates that the lattice girder can be effectively used as a support in tunneling.

  • PDF

Seismic Performance of Rib Plate H Beam to Column Connections (리브로 보강된 기둥-보 접합부의 내진성능 평가)

  • Kim, Sung-Yong;Shin, Chang-Hoon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.1 s.20
    • /
    • pp.9-16
    • /
    • 2006
  • The moment resisting frame has been well-known as it had very excellent seismic performance, and it has been widely used and constructed in the design of a lot of buildings. However, the moment resisting frame system did not exert the seismic performance during the earthquake in Northridge and Kobe sufficiently, and it produced the crack or brittle fracture on the joint. this study was to ]m tests with the full-scale test subject as parameters of existence of H-beam web high tensile bolt shearing joint and reinforcement of H-flange rib. This researcher was to anticipate the decrease of number of high tensile bolts and the improvement of workability through the double shear joint by the experiment, and improve the seismic performance through the reinforcement of rib plate. In addition, this study was to prevent the brittle fracture by the stress concentration through the non scallop.

Structural Analysis of CBS (Composite Basement Wall System)-RIB Underground Structures Using Numerical Modeling (수치해석을 통한 강합성 빔보강 지하 구조물의 거동분석)

  • Yoo, Han-Kyu;Kim, Yeon-Sung
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.6
    • /
    • pp.39-44
    • /
    • 2010
  • In case of the design method, which is used in the inside and outside of the country, on corrugated multi plate structures, section modulus would be determined by assuming 2-dementioanl equivalent section of those structures. However, it is impossible to consider 3-dimentional effects when 2-dimentional design method is applied since structures are reinforced with a pattern of the 1200, 1600 mm reinforcements except the 800 mm reinforcement. Thus, in this study, technical specification standard is analyzed for the existing corrugated multi plate design methods, and section strengths, moments, and so on of equivalent and practical sections are compared and estimated using 3-dimentional FEM (finite element method) for semicircles and architectural features widely used. Based on the results of that analysis, analytical basis for 3-dimentional design of the CBS-RIB is suggested.

A Numerical Study on Performance of Air-to-Air Plastic Plate Heat Exchanger

  • Chung, Min-Ho;Yoo, Seong-Yeon;Han, Kyu-Hyun;Yoon, Hong-Ik;Kang, Hyoung-Chul
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.2
    • /
    • pp.52-60
    • /
    • 2009
  • The purpose of this research is to develop high efficiency plastic plate heat exchangers which can be substituted for conventional aluminum plate heat exchangers. Four simulation models of plastic plate heat exchangers are designed and simulated: that is, flat plate type, turbulent promoter type, corrugate type and dimple type heat exchanger. The flat plate type is designed as the reference model in order to evaluate how much thermal performance increases. The turbulent promoter type is fabricated with cylindrical-type vortex generators and rib-type turbulent promoters. The corrugate type is obtained from the conventional stainless steel compact heat exchangers, which are called the herringbone-type compact heat exchangers. The dimple type has a number of dimples on its surface. In this study, the flow and heat transfer characteristics of the plastic plate heat exchanger are investigated using numerical simulation and compared with experimental results. Numerical simulation is carried out using the FLUENT code. The flows are assumed as a three-dimensional, incompressible and turbulent model. The computational analysis and experimental results both show that the friction coefficient and Nu number is highest in the corrugate type. The tendency of numerical simulation results is in good agreement with that of the experimental results.

The Orthotropic Plate Analysis of Stiffened Plataes with Open Ribs (개단면 리브를 갖는 보강판의 직교이방성 판 해석)

  • Chu, Seok Beom;Kim, Chang Su
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.6
    • /
    • pp.701-710
    • /
    • 2002
  • An analysis program using orthotropic plate elements was developed to simplify the analysis of plates stiffened with open ribs and the orthotropic behavior of stiffened plates and the application of this program were evaluated using the sensitivity analysis and the parametric study. The inertial moment ratio, i.e., the ratio of the inertial moment of the rib to that of the plate was defined and the orthotropic behavior of stiffened plates corresponding to the inertial moment ratio was proved by the sensitivity analysis. To evaluate the application of this program, the parametric study for various types of stiffened plates was performed and then the maximum displacement of this study was compared to that of ABAQUS using isoparametric plate elements. The Results of this study agreed well with that of ABAQUS at the particular inertial moment ratio, that is proposed to the limit ratio of the orthotropic plate analysis and the correlative function between the error ratio and the inertial moment ratio was obtained. Therefore, the orthotropic plate analysis of stiffened plates with open ribs could have safe results over the limit ratio and also have good results simply by using the correlative function of this study.

The Modified Coefficient of the Orthotropic Rigidity for Stiffened Plates with Open Ribs (개단면 리브를 갖는 보강판의 직교이방성 강성 수정 계수)

  • Chu, Seok Beom;Choi, Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.1 s.74
    • /
    • pp.23-32
    • /
    • 2005
  • In this paper, the modified coefficient of the orthotropic rigidity for stiffened plates with open ribs is proposed to improve the inaccurate results of the orthotropic plate analysis. For stiffened plates with rectangular and angle ribs having various aspect ratios and boundary conditions, the aspect ratio and the rigidity ratio are selected as parameters and the parametric study on the modified coefficient is performed. Analyzed results of stiffened plates modeling with the isotropic and orthotropic plate element show that the modified coefficient can be expressed as a function of the rigidity ratio for each rib space regardless of the aspect ratio in case of the aspect ratio under 1 and can be represented as a single union function without regard to rib spaces and aspect ratios in the other case. The results also shows that the effects of the boundary condition on the modified coefficient is small and coefficient functions have different values according to rib shapes. The application to examples shows that the modified coefficient of the orthotropic rigidity improves accuracy. Therefore, the orthotropic plate analysis of stiffened plates with open ribs can easily achieve more accurate results using the coefficient function proposed in this study

Analytical Study on Ultimate Design Method of Tube Flange Joints with the Rib Plate Using the High Strength Bolt (리브 붙은 고력볼트 강관플랜지 이음의 극한 설계방법에 관한 해석적 연구)

  • Kim, Seong Eun
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.5 s.48
    • /
    • pp.537-547
    • /
    • 2000
  • The tube flange joint often used in the field is a kind of tensional joint method using the high strength bolts. Transferring stress is conducted by high axial pressure between each part of material that is produced by twisting the high strength bolts. And historical characteristics of the flange joint have not been studied sufficiently and it is difficult to say that the design method is established definitely. Therefore new method using ultimate strength is need to be suggested to solve there problems in using flange joint. The purposes in this study are to gain the data base for establishing design method of joint in the form like figure1 and survey whether the joint of tube flange with non-equal diameter can be designed or not in the form like rib or ring.

  • PDF

Cyclic Loading Test for Exposed Column-base Plate Connections of Small-size Steel Structures (소규모 철골조 노출형 주각부의 반복가력 실험)

  • Lim, Woo-Young;You, Young-Chan;Yoo, Mi-Na
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.2
    • /
    • pp.34-45
    • /
    • 2017
  • Cyclic loading tests for a total of nine test specimens were performed to evaluate the seismic performance of the exposed steel column-base plate connections. From the tests, flexural strength, deformation capacity, energy dissipation, and initial stiffness were investigated. The primary test parameters were the thickness of base-plate, embedment length of anchor bolt, the presence of hook, and rib plates. Test results showed that flexural behavior of column base-plate connection was substantially affected by the base-plate thickness, embedment length and the number of anchor bolts. On the other hand, the effect of rib plates on the increase of the flexural performance was not observed. The initial stiffness of the test specimens was about 15% of the flexural stiffness obtained by assuming that the support is fixed. As a result, even if the exposed column base-plate is designed in accordance with current design recommendations, in case that bond strength between concrete and the anchor bolts is not sufficient, the base-plate connection showed an unaccceptable load-displacement behavior.

A study on the fatigue characteristics of SM 490 A material due to the welding type (SM 490 A 재질에 대한 용접 유형에 따른 피로특성 연구)

  • Kim, Jae-Hoon;Goo, Byung-Choon
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.274-278
    • /
    • 2004
  • This study investigates the fatigue characteristics of SM 490 A material specimens for the railway vehicle due to the welding type. The more stress ratio decreases, the more strength of fillet welded specimen decreases. At speciallly, when the stress ratio of TN(Plate with transverse fillet welded rib) specimens decreases 0.5, 0.1, and -0.1, the fatigue limit decreases unifomly. The strength of TN is higher than it of NCN in the compare of fillet welding type, but the strength of NCN(Non load-carrying cruciform fillet welded joint) is higher than it of CN(Load-carrying cruciform fillet welded joint), which these specimens have the rib in the both side. We analysis the strains on the weld positions of the TN specimens during the fatigue test for the investigation of crack initiation and crack growth. In the theses results, we could find the fatigue crack initiation point and time.

  • PDF

The Measurement and Analysis of Three-Dimensional Light Emitted from Plasma Disp1ay Panel by Optica1 Method (광학적인 방법에 의한 플라즈마 디스플레이 패널의 3차원 광 방출 측정과 분석)

  • Choe, Hun-Yeong;Lee, Seok-Hyeon;Lee, Seung-Geol
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.1
    • /
    • pp.31-38
    • /
    • 2002
  • We measured a 3-dimensional images of the light emitted from plasma display panel(PDP) by using newly proposed scanned point detecting system. In the panel without phosphor, as we scan from the rear glass to the front glass, the detected light intensity increases and the light intensity detected in the inside edge of the ITO electrodes shows the stronger intensity than others. The light intensity detected between the barrier ribs shows the largest value of brightness. Also, as the sustain voltage increases, the detected light intensity increases. In the panel with phosphor, the intensity of light detected at barrier rib shows the stronger light intensity than rear plate. Therefore, the phosphor of barrier rib is very important. From these results the 3-dimensional measurement is necessary to understand exactly the discharge phenomenon in the PDP cell.