• 제목/요약/키워드: Reynolds

검색결과 3,672건 처리시간 0.031초

Thermal and Absorbing Performance in a Vertical Absorber

  • Cho, Keum-Nam;Kim, Jung-Kuk
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권2호
    • /
    • pp.51-59
    • /
    • 2000
  • The purpose of the present study is to investigate the absorbing characteristics in a vertical falling film type absorber using LiBr-H$H_2O$ solution as working fluids with the concentration of 60 wt%. The experimental apparatus consists of an absorber with the diameter of 17.2 mm and the length of 1150 mm, a generator, an evaporator (condenser), a weak solution tank and a sampling trap device and so on. The parameters were the solution temperatures of 45 and 50$^{\circ}$C, coolant temperatures of 30 and 35$^{\circ}$C, and the film Reynolds numbers from 50 to 150. The pressure drop in the absorber increased as the solution and coolant temperatures decreased. The pressure drop in the absorber increased up to the film Reynolds number of 90, however, decreased at the film Reynolds number above 90. The maximum absorption mass flux was observed at the film Reynolds number of 90. Absorption mass fluxes increased as the coolant temperature decreased. Accordingly, absorption mass fluxes and heat transfer coefficients under the subcooled condition increased more than those under the superheated condition. It is claimed that heat transfer coefficients are deeply affected by the solution temperature more than the coolant temperature within the experimental range.

  • PDF

근적외선 열풍기의 복합열전달에 관한 수치적 연구 (NUMERICAL STUDY ON COMBINED HEAT TRANSFER IN NIR HEATING CHAMBER)

  • 최훈기;유근종;김인호
    • 한국전산유체공학회지
    • /
    • 제12권4호
    • /
    • pp.7-13
    • /
    • 2007
  • Numerical analysis is carried out for combined heat transfer in an indirected NIR(Near Infrared Ray) heating chamber. Reynolds number and shapes of absorbed cylinder are known as important parameters on the combined heat transfer effects. Reynolds number based on the outer diameter of the cylinder is varied from $10^3$ to $3{\times}10^5$. Four difference heat transfer regimes are observed: forced convection and radiative heat transfer on the outer surface of the cylinder, pure conduction in the cylinder body, pure natural convection and radiation between lamp surface and inner surface of the cylinder, and radiation from the lamp. Flow and temperature characteristics are presented with iso-contour lines for the absorbed circular and elliptic cylinders to compare their differences. The convective and radiative heat transfer fluxes are also compared with different Reynolds numbers. As usual, Reynolds number is an important factor to estimate increasing convective heat transfer as it increases. The shape of absorbed cylinder results overall heat transfer rates remain unchanged.

Experimental study on Re number effects on aerodynamic characteristics of 2D square prisms with corner modifications

  • Wang, Xinrong;Gu, Ming
    • Wind and Structures
    • /
    • 제22권5호
    • /
    • pp.573-594
    • /
    • 2016
  • Simultaneous pressure measurements on 2D square prisms with various corner modifications were performed in uniform flow with low turbulence level, and the testing Reynolds numbers varied from $1.0{\times}10^5$ to $4.8{\times}10^5$. Experimental models were a square prism, three chamfered-corner square prisms (B/D=5%, 10%, and 15%, where B is the chamfered corner dimension and D is the cross-sectional dimension), and six rounded-corner square prisms (R/D =5%, 10%, 15%, 20%, 30%, and 40%, where R is the corner radius). Experimental results of drag coefficients, wind pressure distributions, power spectra of aerodynamic force coefficients, and Strouhal numbers are presented. Ten models are divided into various categories according to the variations of mean drag coefficients with Reynolds number. The mean drag coefficients of models with $B/D{\leq}15%$ and $R/D{\leq}15%$ are unaffected by the Reynolds number. On the contrary, the mean drag coefficients of models with R/D=20%, 30%, and 40% are obviously dependent on Reynolds number. Wind pressure distributions around each model are analyzed according to the categorized results.The influence mechanisms of corner modifications on the aerodynamic characteristics of the square prism are revealed from the perspective of flow around the model, which can be obtained by analyzing the local pressures acting on the model surface.

선박의 저항성능 추정을 위한 EARSM 난류 모형의 활용 (Numerical Prediction of Ship Hydrodynamic Performances using Explicit Algebraic Reynolds Stress Turbulence Model)

  • 김유철;김광수;김진
    • 대한조선학회논문집
    • /
    • 제51권1호
    • /
    • pp.67-77
    • /
    • 2014
  • In this study, Explicit Algebraic Reynolds Stress Model (EARSM) which is based on the existing ${\kappa}-{\omega}$ model has been applied to the flow field analysis around ship hulls. Existing transport equations for the turbulent kinetic energy and the dissipation rate are used in almost the same form and anisotropy terms of Reynolds stresses are newly considered. The well-known KVLCC2 and KCS hull forms are selected as validation cases, which were also used in 2010 Workshop on CFD in Ship Hydrodynamics. In case of KVLCC2 double model, comparison of mean velocity distribution, turbulent kinetic energy, and Reynolds stresses near the propeller plane has been carried out and wave elevation and wave profiles have been additionally studied for KCS and KVLCC2 with free surface models. Some improved results for mean velocity distribution at the propeller plane have been obtained while there is little change in free surface wave profiles.

수직형 흡수기내 열 및 물질 전달 특성 (Heat and mass transfer characteristics in a vertical absorber)

  • 서정훈;조금남;최기봉
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.835-845
    • /
    • 1999
  • The objective of the present study was to investigate heat and mass transfer characteristics in a vertical falling film type absorber using LiBr-$H_2O$ solution with 6owt%. The experimental apparatus consisted of an absorber with inner diameter of 17.2 mm and length of 1150mm, a generator, an evaporator/condenser, a solution tank, a sampling trap etc. The parameters were solution temperature of 45 and $50^{\circ}C$, coolant temperature of 30 and $35^{\circ}C$, and film Reynolds numbers from 50 to 150. Pressure drop in the absorber increased as solution and coolant temperatures decreased. Pressure drop in the absorber increased up to the film Reynolds number of 90, and then decreased at the further increase of the Reynolds number above 90. The maximum absorption mass flux observed at the film Reynolds number of 90. Absorption mass flukes increased as coolant temperature decreased. Absorption mass fluxes and heat transfer coefficients under subcooled condition were larger than those under superheated condition. Heat transfer coefficients were affected by solution temperature more than coolant temperature. The maximum absorption effectiveness under the subcooled condition was 23% for coolant temperature of $30^{\circ}C$ and 31% for coolant temperature of $35^{\circ}C$ under the present experimental conditions.

  • PDF

핵 연료집합체 부수로 해석을 위한 횡 방향 압력손실계수의 수치적 결정 (Numerical Determination of Lateral Loss Coefficients for Subchannel Analysis in Nuclear Fuel Bundles)

  • Kim, Sin;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • 제27권4호
    • /
    • pp.491-502
    • /
    • 1995
  • 핵연료집합체 부수로 유동장에 대한 상세한 정보에 기초해 교차류를 정확히 예측하는 것은 핵연료의 성능을 해석하는데 중요한 요소이다. 본 연구에서는 저-Reynolds 수 k-$\varepsilon$ 난류모형을 채택하여 인접한 두 부수로 사이에 발생하는 교차류를 해석하였다 또한, 2차유동을 정확히 모사하기 위해서 비등방성 대수응력모형을 사용하였다. 이상의 난류 모형은 유한요소법을 통해 해석되었으며 가용한 실험자료와 비교하여 검증하였다. 그리고, 부수로 유동장에 대한 수치해석 결과를 이용하여 횡방향 합력손실계수의 상관식을 구성하였다. 상관식은 교차류를 제공하는 부수로의 축방향 속도에 대한 교차류의 속도비, 제공받는 부수로의 Reynolds 수 그리고 Pitch-to-diameter의 함수로 구성되었다.

  • PDF

Reynolds Number를 변수로한 유동공기의 방전특성에 관한 연구 (Characteristics of Sparkover Discharge in Flowing Air with Reynolds Number's Variable)

  • 김영훈;이동인;이광식;김상구
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1990년도 추계학술발표회논문집
    • /
    • pp.41-46
    • /
    • 1990
  • This paper shows the characteristics of sparkover discharge in flowing air ranging from O(Reynolds number, Re to 10.52$\times$104(Re). Also, we investigated changes of dis-charge pattern for constant input power by adjustment of the Re. The important results obtained from this paper are as followers. The maxinum sparkover voltage of flowing air are about 6.3[kV] higher than those of static air. The discharge pattern can be controlled by adjustment of the Re.

  • PDF

수직한 벽면에서 혼합증기(수증기/공기)의 막응축 열전달

  • 박수기;김무환;유건중
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 추계학술발표회논문집(1)
    • /
    • pp.217-223
    • /
    • 1996
  • 혼합증기(수증기/공기)의 막응축 열전달 계수를 수직한 벽면에서 측정하고 상관식을 개발하였다. 열전달 상관식은 액막측과 증기측으로 구분하여 만들었고, 액막측 전열계수의 상관식은 액막의 Reynolds수와 Prandtl수의 함수로 나타냈으며, 증기측 전열계수의 상관식은 증기의 Reynolds수, Prandtl수, Schmidt수 및 공기의 질량분율, 액막 Reynolds수의 함수로 제안하였다. 응축 액막의 두께와 확산층의 순간온도 측정결과로부터 액막의 파형 계면이 확산층에서의 열 및 물질전달에 큰 영향을 끼치고 있음을 확인하였고, 증기측 전열계수의 상관식에 포함된 액막 Reynolds수가 파형 계면의 영향을 반영하고 있다.

  • PDF

Archimedes number를 이용한 장방형 침전지내 수리흐름 평가에 관한 연구 (Evaluation of Hydrodynamic Behavior in Horizontal Settling Basin with Archimedes number)

  • 박노석;이상욱
    • 상하수도학회지
    • /
    • 제23권6호
    • /
    • pp.865-870
    • /
    • 2009
  • In this study, the adequacy of Reynolds numbers and Froude numbers derived from about sixty domestic water treatment plants (WTPs) were analyzed in order to estimate the characteristics of hydraulic behavior within the rectangular shaped sedimentation basins used widely. From the results of analysis, most of domestic WTPs have satisfied the criteria regulated as that Reynolds number should less than 1,000(dimensionless). On the other hand, they have not been able to satisfy the Froude number criteria, which should be higher than $1.0{\times}10^{-6}$. The reasons why most of domestic WTPs could not satisfy the criteria are that its criteria basis has been not only inadequate, but also the concept of external flow occurred around a settling particle has been ignored. Accordingly, this study proved the feasibility of Archimedes number, which indicates the ratio between particle Reynolds number and Froude number, to evaluate the hydraulic efficiency and its function of scale factor.

Turbulence Characteristics in a Circular Open Channel by PIV Measurements

  • Kim, Sun-Gu;Sung, Jae-Yong;Lee, Myeong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권7호
    • /
    • pp.930-937
    • /
    • 2011
  • The characteristics of mean velocity and turbulence have been analyzed in the circular open channel flow using PIV measurement data for a wide range of water depth. The measured data are fitted to a velocity distribution function over the whole depth of the open channel. Reynolds shear stress and mean velocity in wall unit are compared with the analytic models for fully-developed turbulent boundary layer. Both the mean velocity and Reynolds shear stress have different distributions from the two-dimensional boundary layer flow when the water depth increases over 50% since the influence of the side wall penetrates more deeply into the free surface. The cross-stream Reynolds normal stress also has considerably different distribution in view of its peak value and decreasing rate in the outer region whether the water depth is higher than 50% or not.