• Title/Summary/Keyword: Reversed-phase high-performance liquid chromatography

Search Result 211, Processing Time 0.029 seconds

Determination of Co(II) Ion as a 4-(2-Thiazolylazo)resorcinol or 5-Methyl-4-(2-thiazolylazo)resorcinol Chelate by Reversed-Phase Capillary High-Performance Liquid Chromatography

  • Chung, Yong-Soon;Chung, Won-Seog
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.12
    • /
    • pp.1781-1784
    • /
    • 2003
  • Determination of Co(II) ion as a 4-(2-thiazolylazo)resorcinol(TAR) or 5-methyl-4-(2-thiazolylazo)resorcinol(5MTAR) chelate was accomplished by reversed-phase capillary high-performance liquid chromatography (RP-Capillary-HPLC) using a Vydac $C_4$ column and MeCN-water mixture as mobile phase. The effect of change in pH and MeCN percentage of the mobile phase on the retention factor, k and peak intensity were evaluated. It was found that 30% MeCN (v/v) of pH 5.60 or 7.20 was adequate as mobile phase when TAR or 5MTAR is used. Detection limit (D.L., S/N=3) in each case was $2.0\;{\times}\;10^{-7}$M (11.8 ppb) and $3.0\;{\times}\;10^{-7}$ M (17.7 ppb). The Co(II) ion in mineral and waste water was determined with the optimum column and mobile phase.

Chiral Purity Test of Metoprolol Enantiomer After Derivatization with (-)-Menthyl Chloroformate by Reversed-Phase High Performance Liquid Chromatography

  • Kim, Kyeong-Ho;Choi, Pok-Wha;Hong, Seon-Pyo;Kim, Hyun-Ju
    • Archives of Pharmacal Research
    • /
    • v.22 no.6
    • /
    • pp.614-618
    • /
    • 1999
  • A reversed-phase high-performace liquid chromatographic method was developed to determine the optical purity of metoprolol enantiomers. The enantiomers were converted to diastereomeric derivatives using (-)-menthyl chloroformate reagent. Separation of the enantiomers as diastereomers was achieved by reversed-phase HPLC within 30 min using Inertsil C8 column. This method allowed determination of 0.05% of either enantiomer in the presence of its stereoisomer and method validation showed adequate linearity over the required range. Owing to the reaction condition during the derivatization with (-)-menthyl chloroformate, the possibility of racemization had to be established. Different ratios of (S)-(-)-metoprolol and (R)-(+)-metoprolol were prepared. Enantiomeric separation of these mixtures took place on a chiralcel OD column or, after derivatization with (-)-menthyl chloroformate, on a C8 column. The results form the these two independent separation systems were compared with trace racemization and were in very good agreement. No racemization was found during the experiment.

  • PDF

Hydrophilic Interaction Liquid Chromatography (HILIC 분석법 개발을 위한 지능형 솔루션)

  • Matt James;Colin Pipe;Mark Fever;Jen Field;Seungho Chae
    • FOCUS: LIFE SCIENCE
    • /
    • no.1
    • /
    • pp.6.1-6.9
    • /
    • 2024
  • The document is a white paper on Hydrophilic Interaction Liquid Chromatography (HILIC) analysis method development. HILIC is a type of chromatography that uses an organic/aqueous mobile phase and a polar stationary phase. In HILIC, water is a strong solvent, and unlike in Reversed Phase Liquid Chromatography (RPLC), increasing the proportion of water in the mobile phase reduces the retention time of the analyte. The paper discusses when to consider HILIC analysis methods, the advantages of HILIC, and the challenges often encountered due to the lack of understanding of HILIC mechanisms compared to RPLC. It also provides a systematic flowchart for intelligent solutions for HILIC analysis method development, which includes a three-step approach for chromatography analysis method development. The first step involves gathering as much information as possible about the analyte (e.g., pKa, log P, log D). The second step involves analyzing the sample under different pH conditions using three HILIC columns in either isocratic or gradient mode to identify the suitable column/pH combination for the analyte. The third step involves optimizing the separation by investigating other parameters such as temperature and ionic strength, and assessing the robustness of the method. The paper emphasizes that the selection of the appropriate stationary/mobile phase combination, based on the differences between the HILIC stationary phases and the mobile phase pH, can provide high selectivity in the analysis. This step-by-step approach can help users develop an efficient analysis method.

  • PDF

Determination of Ginseng Saponins by Reversed-Phase High Performance Liquid Chromatography (역상 고속 액체크로마토그래피를 이용한 인삼 사포닌의 분석)

  • Jeong, Seung-Il;Kim, Choen-Suk;Lee, No-Woon;Choi, Kang-Ju;Lee, Yong-Gu;Kim, Il-Kwang
    • Analytical Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.436-439
    • /
    • 1998
  • Ginseng saponins were analysed using reversed-phase high performance liquid chromatography with several columns. The optimum conditions were as following : reverse phase column; Novapak $C_{18}$ ODS column ($3.9mm{\times}150mm$, $5{\mu}m$), acetonitrile/water binary mobile phase gradient controller system, solvent flow rate; 1.5 mL/min, and UV (203 nm) detector. The complete separation of ginsenoside $Rb_1$, $Rb_2$, Rc, Rd, Re, Rf and $Rg_1$ was achieved within 50 min. The regression coefficients of the calibration curves for seven ginsenosides were 0.98~0.99.

  • PDF

On-line Trace Enrichment for the Determination of Insulin in Biological Samples Using Reversed-Phase High Performance Liquid Chromatography with Column Switching

  • Lee, Jung-Sook;Lee, Heeyong;Lee, Hye-Suk;Lee, Kang-Choon
    • Archives of Pharmacal Research
    • /
    • v.17 no.5
    • /
    • pp.360-363
    • /
    • 1994
  • Column--swtiching technique with a reversed-phase high performance liquid chromatographic method has been developed for the routine analysis of radioiodinated insulin and its degadation products in biological fluids. The diluted biological samples were loaded onto a precolumn packed with LiChrosorb RP-8 $(25-40{\;}{\mu}m)$ using 0.1% trifuoroacetic acid (TFA) in water as a washing solvent. After valve switching, the concentrated insulins were eluted in the back-flush mode and separated by a W-Porex $C_{18}$ column with a gradient of 0.1% TFA in water and 0.1% TFA in acetonitrile as the mobile phase. The method showed good precision, accuracy and speed with the detection limit of 20 pg/ml. Total analysis time per sample was about 40 min and the coefficients of variation were less than 8, 2%.

  • PDF

Simultaneous Determination of the Water Soluble Vitamins in Multi-Nutrient Tablets by Reversed-Phase High-Performance Liquid Chromatography

  • Kim, Hyung-Soo;Jang, Duck-Kyu;Woo, Dong-Kyun;Woo, Kang-Lyung
    • Preventive Nutrition and Food Science
    • /
    • v.7 no.1
    • /
    • pp.12-17
    • /
    • 2002
  • Simultaneous determination of nine water-soluble vitamins contained in multi-nutrient tablets was carried out by reversed phase high-performance liquid chromatography (RP-HPLC) equipped with analytical $C_{18}$ column and UV (270 nm) detector. Those standard vitamins were successfully separated within 23 minutes by gradient elution with solvent A (0.5 M potassium phosphate monobasic) and solvent B (0.25 M potassium phosphate monobasic-methanol, 1:1). Calibration curves showed good linealities with correlation coefficients (> 0.92) in tested ranged respectively. The detection limits were considered to be 2.1 ng for ascorbic acids 60 ng for Vit B$_{6}$ 3 ng for p-aminobenzoic acid, 9 ng for niacinamide, 9 ng for thiamin, 5.0 ng for folic acid and 1.5 ng for riboflavin at 0.05 a.u.f.s. Solid phase extraction through Sep-Pak (C$_{18}$ ) cartridge was successfully applied for purification of water soluble vitamins in commercial multi-nutrient tablets.ts.

A Study on the Elution Behavior of some Metal-N-Alkylisonitrosoacetylacetone imine Chelates by Reversed Phase High Performance Liquid Chromatography (역상 액체 크로마토그래피에 의한 몇 가지 금속-N-Alkylisonitrosoacetylacetone imine 킬레이트의 용리거동에 관한 연구)

  • Kim, Yong Jun;Kewon, Ji Hae;Lee, Won
    • Analytical Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.63-71
    • /
    • 1992
  • Liquid chromatographic behavior of Pd(II), Ni(II) and Co(III) in N-Alkylisonitrosoacetylacetone imine(HIAA-NR) chelates was investigated by reversed phase high perfomance liquid chromatography. The optimum conditions for the separation of IAA-NR-metal chelates were examined respect to the flow rate and mobile phase strength. The metal-N-Alkylisonitrosoacetylacetone imine chelates in solution were successfully separated on Novapak $C_{18}$ column using acetonitrile/water mixture as mobile phase. The elution order of chelates is methyl>ethyl>propyl>butyl as N-alkyl group for ligand is varied. It was found that all IAA-NR-metal chelates were eluted in an acceptable range of capacity factor value($0{\leq}log\;k^{\prime}{\leq}1$). The dependence of log k' on the volume fraction of water in the binary mobile phase was examined. Also, the dependence of k' on the liquid-liquid extraction distribution ratio(Dc) in acetonitrile-water-alkane extraction system was investigated for IAA-NR-metal chelate. Both kinds of dependence are linear, which suggests that the retention of the electroneutral metal chelates on Novapak $C_{18}$ column is largely due to the hydrophobic effect.

  • PDF

Mutation Analysis in β2-Adrenergic Receptor Gene by Single Strand Conformation Polymorphism (SSCP) and Denaturing High Performance Liquid Chromatography (DHPLC) (SSCP와 DHPLC에 의한 β2-교감신경수용체 유전자의 돌연변이 분석)

  • Park, Sang-Bum;Han, Sang-Man;Nam, Youn-Hyoung;Jang, Won-Cheoul
    • Analytical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.53-59
    • /
    • 2004
  • Up to now, methods for the detection of genetic alterations as single strand conformation polymorphism (SSCP) or denaturing gradient gel electrophoresis (DGGE) have been used. It is too labor-intensive and expensive to serve for routine analysis. Moreover, lower in its sensitivity and specificity being also strongly dependent on the experience of the investigater. To improve these problems, we analysed mutation of ${\beta}_2$-adrenergic receptor gene that controls bronchial asthma by denaturing high performance liquid chromatography (DHPLC) according to ion-pair reversed phase chromatography (IP-RPC). We extracted genomic DNA from 80 asthma patients and then amplified DNA using PCR and analysed PCR product by SSCP and DHPLC. As a result, we analysed mutation frequency is 19 (23.75%) on SSCP and 25 (31.25%) on DHPLC in ${\beta}_2$-adrenergic receptor gene. We conclude that DHPLC is a fast and simple screening method rather than SSCP analysis.

Optical Resolution of Dabsyl Amino Acids in Reversed-Phase Liquid Chromatography

  • Lee, Sun-Haing;Oh, Tae-Sub;Lee, Young-Cheal
    • Bulletin of the Korean Chemical Society
    • /
    • v.11 no.5
    • /
    • pp.411-415
    • /
    • 1990
  • The dabsylation of amino acids has been applied to resolve their optical isomers with the use of chiral mobile phase in high performance liquid chromatography. The dabsyl amino acids were successfully separated on reversed phase column($C_{18}$) by adding a chiral L-benzylproline-Cu(II) chelate to the mobile phase. The separation selectivity of the dabsyl amino acid enantiomers was not less than that of dansyl amino acids. The retention order of the dabsyl amino acid enantiomers was as those of the dansyl amino acid enantiomers except dabsyl threonine. The optical selectivity of the dabsyl amino acids increase with pH of the mobile phase and concentration of the chelate, but slightly decreases with concentration of buffer and organic solvent composition. However serine, methionine, valine, and leucine showed a slight decrease in the optical selectivity with increase in pH. The retention times of the dabsyl amino acids decreases with increasing pH and acetonitrile concentration but increases with the concentration of the chiral chelate added. The mechanism of the optical resolution is based on a stereospecific interaction including a intramolecular hydrophobic effect and SN-2 reactivity of the ligand exchange chromatography.It is advantageous to detect absorption at 436 nm, which is less interferent them the other detection systems. The derivatized dabsyl amino acids are stable for a month.

Determination Method of Puerarin and Daidzin from Puerariae Radix by Reversed-Phase HPLC with Pulsed Amperometric Detection (RP-HPLC-PAD를 이용한 갈근(葛根)과 갈근(葛根) 함유 처방의 Puerarin과 Daidzin 분석)

  • Chiao, Chen-Ying;Kwon, Ha-Jeong;Jeong, Ji-Seon;Lee, Je-Hyun;Hong, Seon-Pyo
    • The Korea Journal of Herbology
    • /
    • v.23 no.4
    • /
    • pp.171-177
    • /
    • 2008
  • Objectives: This study presents a reversed-phase high-performance liquid chromatography- pulsed amperometric detection(RP-HPLC-PAD) method for the determination of puerarin and daidzin in Puerariae Radix extract and Chinese medicinal preparations. Methods: Chromatographic separation was performed using a 10% acetonitrile with a reversed-phase column(Unison UK-C18, $100mm{\times}2.0mm$ I.D.; $3{\mu}m$). The analyses were detected by pulsed amperometric detector(PAD) in alkaline conditions by combining with post-column NaOH solution. Geniposide was used as an internal standard. Results: The limit of detection(S/N=3) and the limit of quantification(S/N=10) were 0.025 ng, 0.075 ng for puerarin, and 0.05 ng, 0.15 ng for daidzin, respectively. The intra- and inter-day precisions(RSDs) were less than 6.5% and average recoveries of puerarin were 99.7-101.3% and those of daidzin were 101.0-102.8%. Conclusions: According to above results, we developed a determination method for puerarin and daidzin in Puerariae Radix with high sensitivity and selectivitely.

  • PDF