• 제목/요약/키워드: Reversed trapezoidal fin

검색결과 6건 처리시간 0.02초

ANALYSIS OF A REVERSED TRAPEZOIDAL FIN USING A 2-D ANALYTIC METHOD

  • Kang, H.S.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제14권3호
    • /
    • pp.151-161
    • /
    • 2010
  • A reversed trapezoidal fin is analyzed using a two-dimensional analytical method. Heat loss from the reversed trapezoidal fin is presented as a function of the fin shape factor, fin base thickness and the fin base height. The relationship between the fin tip length and the convection characteristic number as well as that between the fin tip length and the fin base height for equal amounts of heat loss are analyzed. Also the relationship between the fin base thickness and the fin shape factor for equal amount of heat loss is presented. One of the results shows that the heat loss decreases linearly with the increase of the fin shape factor.

역 사다리꼴 핀의 최적화 (Optimization of a Reversed Trapezoidal Fin)

  • 강형석
    • 대한기계학회논문집B
    • /
    • 제30권10호
    • /
    • pp.987-995
    • /
    • 2006
  • A reversed trapezoidal fin with the fluid in the inside wall is analyzed and optimized in this study. As a fin base boundary condition, the heat transfer from inside wall fluid to the fin base is considered. The values of fin base temperature with the variations of inside wall fluid convection characteristic number and fin base length are listed. The heat transfer, fin effectiveness, fin length and fin base height are optimized as a function of fin base length, convection characteristic number ratio, fin shape factor and fin volume.

진공관형 태양열 집열기를 이용한 건조장치의 열교환기 해석 (Analysis of heat exchanger in the drying system using solar collector with evacuated tubes)

  • 강형석;한영민;이귀현;이성주;윤세창
    • 신재생에너지
    • /
    • 제2권1호
    • /
    • pp.46-55
    • /
    • 2006
  • The performance enhancement of heat exchanger in the drying system using solar collector with evacuated tubes is analyzed. First, for this analysis, the heat loss from a reversed trapezoidal fin attached at the pipe is calculated as a function of convection characteristic number ratio, fin base length and fin tip length. Also, the optimum heat loss and fin tip length of the fin under certain conditions are presented. The overall surface effectiveness of the cylinder with reversed trapezoidal fins in the heat exchanger are shown as a function of half fin base height, fin lateral slope and fin tip length.

  • PDF

핀 바닥 두께가 변화하는 역 사다리꼴 핀의 최적 설계 (Optimum Design of a Reversed Trapezoidal Fin with Variable Fin Base Thickness)

  • 강형석
    • 설비공학논문집
    • /
    • 제20권7호
    • /
    • pp.455-461
    • /
    • 2008
  • A reversed trapezoidal fin with variable fin base thickness is optimized using a two-dimensional analytical method. For the fin base boundary condition, instead of a constant temperature, heat transfer from the inside fluid to the fin base is considered. Heat loss from the fin tip is not ignored. The maximum heat loss, corresponding optimum fin effectiveness, fin length and base height are presented as a function of the fin base thickness, shape factor and volume.

역 사다리꼴 핀의 최적화에 미치는 내 외 유체의 영향 (The Effect of Inside and Outside Fluids on the Optimization of a Reversed Trapezoidal Fin)

  • 강형석
    • 한국추진공학회지
    • /
    • 제11권5호
    • /
    • pp.14-22
    • /
    • 2007
  • 측면 표면 기울기가 변화하는 역 사다리꼴 핀이 2차원 해석적 방법을 사용하여 최적화된다. 핀 바닥 경계조건을 위해서, 내부유체로부터 내벽까지의 대류와 내벽부터 핀 바닥까지의 전도가 고려된다. 핀 끝 면으로부터의 열손실은 무시되지 않는다. 실제적인 핀 길이에서의 최대 열손실, 그 최대 열손실이 발생할 때의 최적의 효율, 핀 길이 그리고 핀 바닥 높이가 핀 내 외부의 대류특성계수의 함수로 나타내어진다. 결과 중 하나는 핀 바닥 높이에 대한 핀 끝 높이의 비가 커질수록 최적의 핀 형상은 두껍고 짧아지는 형상이 됨을 보여준다.