• 제목/요약/키워드: Reverse Torque

검색결과 71건 처리시간 0.028초

A STUDY OF THE EFFECT OF AN ANTI-ROTATIONAL INNER POST SCREW SYSTEMS ON ABUTMENT SCREW LOOSENING FOR SINGLE IMPLANT : PART 1

  • Choi, Sun-Young;Lee, Jai-Bong
    • 대한치과보철학회지
    • /
    • 제45권3호
    • /
    • pp.345-353
    • /
    • 2007
  • Statement of problem. Implant abutment screw joints tend to loosen under clinical conditions. Abutment screw loosening results in loss of preload in function. Purpose. Anti-rotational inner post screw (ARIPS) systems were compared with conventional abutment screws to reduce screw loosening. Reverse torque values were evaluated. Material and methods. 32 implant assemblies (Warentec, Co, Ltd, Seoul, Korea) were organized as the 30-Ncm-torque conventional groups and 30-Ncm-torque ARIPS groups in external and internal system. The specimens were tested to 106 cycles at a load of 200N. Preload reverse torque, postload reverse torque, and the ratio of postload reverse torque to preload reverse torque were evaluated. The data were analyzed with unpaired t-test in external and internal systems. Results. In the ratio of postload reverse torque to preload reverse torque, the ARIPS groups showed significant differences than the conventional screw group in both external and internal system. Conclusion. Within the limitations of this study, abutment screw loosening was effectively reduced using ARIPS system.

EFFECT OF THE SURFACE MODIFICATIONS AND THE USE OF WASHER ON THE REVERSE TORQUE OF THE IMPLANT PROSTHETIC GOLD RETAINING SCREW

  • Lee, Jae-Hyuck;Jang, Kyung-Soo;Kim, Chang-Whe;Kim, Yung-Soo
    • 대한치과보철학회지
    • /
    • 제40권3호
    • /
    • pp.246-261
    • /
    • 2002
  • The screw loosening is one of the complications that happen frequently in dental implant prostheses. The purpose of this study was to evaluate the changes of reverse/loosening (opening) torque of the screw according to the surface modifications by sandblasting and 24K gold electroplating as well as to determine the possibility of the clinical use of a washer in dental implant. The reverse torque of 4 experimental conditions(control, sandblasted, use of washers, electroplasted) was measured by digital torque gauge (Model MGT50Z, Mark-10 Corp., 458 West John Street Hicksville, NY 11801 USA). Electronic torque controller (Nobel Biocare DEA 020) was used in fastening the gold screws into abutment replicas. Mixed Linear Model Analysis method was used for statistical analysis. To examine the changes of screw thread surface, microphotographs were taken by Olympus PME-3 metallurgic microscope (Olympus Optical Co. Ltd., Tokyo, Japan). Within the limitations of this study, the following results were drawn: 1. The surface modifications of the gold screws and the use of a washer have significantly affected the reverse torque value compared to the control group (P<0.01). 2. Sandblasting and electroplating treatments demonstrated significantly higher reverse torque value than that of control group. 3. The use of a washer may be one of the useful clinical methods that prevent the screw loosening. However, further studies are necessary for the material selection and design of the washer.

Metal Fastening 공법을 위한 Reverse Screw의 견인력 특성에 관한 연구 (A Study on the Pulling Force Characteristic of the Reverse Screw for the Metal Fastening Method)

  • 김태형;이성욱;한근조
    • 한국기계가공학회지
    • /
    • 제9권1호
    • /
    • pp.93-98
    • /
    • 2010
  • The metal fastening method is the new technology to repair cracks in the casting material using specially designed reverse screws. In this study, we conduct the finite element analysis to analyze the pulling force characteristic of a reverse screw, the core component of the metal fastening method, with respect to the change of the applying torque, frictional coefficient and front screw angle. The simplified analysis model with single screw pitch is proposed for convergency of the non-linear contact analysis. As a results, the pulling force of a reverse screw increase in proportion to the applying torque but exponentially decrease according to frictional coefficient. And also we can find the optimum front screw angle with the largest pulling force is $20^{\circ}$.

CAD/CAM을 이용한 맞춤형 임플란트 지대주의 나사 풀림 토크 평가 (Evaluation of reverse torque value of abutment screws on CAD/CAM custom-made implant abutments)

  • 이창재;양성은;김석규
    • 대한치과보철학회지
    • /
    • 제50권2호
    • /
    • pp.128-134
    • /
    • 2012
  • 연구 목적: 본 연구는 국내 개발된 맞춤형 임플란트 지대주와 기성 임플란트 지대주의 반복 하중 전과 후의 나사 풀림 토크 값을 측정, 비교하여 나사 결합부 안전성에 차이가 있는지를 알아보고자 하였다. 연구 재료 및 방법: 총 12개의 임플란트 고정체(Implantium, Dentium Co., Seoul, Korea)를 알루미늄 원통에 레진으로 고정하고, 그것을 각각 4개씩, 3개의 군으로 나눠서 각 군별로 기성 티타늄 지대주(Implantium, Dentium Co., Seoul, Korea), 캐드캠 맞춤형 티타늄 지대주(Myplant, Raphabio Co., Seoul, Korea), 그리고 금속 연결부가 있는 캐드캠 맞춤형 지르코니아 지대주(Zirconia Myplant, Raphabio Co., Seoul, Korea)를 제작하여 임플란트에 연결하였다. 금속관은 지대주에 맞춰서 티타늄을 밀링해서 제작한뒤 지대주에 합착하였다. 반복 하중을 가하기 전에 지대주 나사를 30 Ncm 토크로 조이고 약 30분 후 나사의 초기 풀림 토크값을 측정하였다. 그 후 반복 하중을 30 N에서 120 N의 싸인 곡선을 이루는 압축력으로 2 Hz의 빈도로 50만 싸이클을 가하고 하중 후 풀림 토크값을 측정하였으며, 풀림 토크 상실률을 구하여서 군끼리 비교하였다. 나사의 풀림 토크값의 상실률의 비교를 위해 Kruskal-Wallis test를 이용해서 유의수준 .05에서 분석하였다. 결과: 반복하중 후 나사 풀림 상실률에서 기성 티타늄 지대주 군에 비해 맞춤형 티타늄 지대주는 높은 값을 보였으나 유의성 있는 차이를 보이지 않았다($P$>.05). 반면, 맞춤형 지르코니아 지대주는 기성 티타늄 지대주에 비해 유의하게 높은 값을 보였다($P$=.014). 결론: 본 실험의 한계 내에서 캐드캠 맞춤형 티타늄 임플란트 지대주는 기성 임플란트 지대주 에 비해 나사 안정성이 떨어진다고 볼 수 없다. 반면, 캐드캠 맞춤형 지르코니아 지대주 는 기성 임플란트 지대주에 비해 나사 안정성이 다소 떨어진다고 볼 수 있다.

농업용 트랙터의 전후진 파워시프트 변속 특성 해석 (Analysis of Power Shuttle Characteristics of Agricultural Tractor)

  • 김대철;이호상;정병학;김경욱
    • Journal of Biosystems Engineering
    • /
    • 제27권6호
    • /
    • pp.479-490
    • /
    • 2002
  • A dynamic model of a power shuttle transmission was developed and its validity was verified using the experimental data obtained from a transmission test bench. A 40㎾, 4WD tractor was also modeled using an application software EASY5 to investigate parameters and their effects on the power shifting performance. For a tractor model, the manual reverse gear was replaced by a power shuttle transmission. The tractor model also included an engine, main-gears for transmission, wheels, differentials and planet gears. Using the tractor model, the effects of the parameters such as modulating pressure and time, engine speed, tractor speed. tractor weight. reverse to forward speed ratio and torsional damper on the transient characteristics at starting and shuttle shifting were investigated by the computer simulation. The transient characteristics were represented by variations in clutch pressure, torque transmitted to input shaft and driving wheels, and power transmission capacity of the clutch. It was found that the modulating pressure and time affected most significantly the torque transmission and shifting time. The input torque, axle torque, power transmission capacity of the clutch and transmission time all increased with increase in engine speed, tractor speed. tractor weight and ratio of reverse to forward speeds. However, the axle torque decreased with tractor speed. Both the axle torque and power transmission capacity of the clutch also decreased with the ratio of reverse to forward speeds.

자동차용 토크 컨버터의 수치해석적 연구(Part I) - 수력학적 설계와 순환유량의 평가 - (A Numerical Study on the Automotive Torque Converter(Part I) - Hydraulic Design and Evaluation of Circulation Flow Rate -)

  • 김홍식;박재인;주원구;조강래
    • 한국자동차공학회논문집
    • /
    • 제6권5호
    • /
    • pp.28-36
    • /
    • 1998
  • In order to establish the hydraulic design process of the torque converter, pump, turbine and stator were designed by reverse design method including one dimensional analysis, angular momentum distribution and forced vortex design. And the significance of evaluation of the circulation flow rate in torus of the torque converter was verified by numerical calculation if the combined blade rows of pump and turbine. It was confirmed that the computational method using interrow mixing model by Park and Cho was reliable to predict the flow-field and performance of the torque converter.

  • PDF

Effect of cyclic loading and retightening on reverse torque value in external and internal implants

  • Cho, Woong-Rae;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권4호
    • /
    • pp.288-293
    • /
    • 2015
  • PURPOSE. The aim of this study was to evaluate the effect of cyclic loading and screw retightening on reverse torque value (RTV) in external and internal type implants. MATERIALS AND METHODS. Cement-retained abutments were connected with 30 Ncm torque to external and internal type implants. Experimental groups were classified according to implant connection type and retightening/loading protocol. In groups with no retightening, RTV was evaluated after cyclic loading for 100,000 cycles. In groups with retightening, RTV was measured after 3, 10, 100 cycles as well as every 20,000 cycles until 100,000 cycles of loading. RESULTS. Every group showed decreased RTV after cyclic loading. Before and after cyclic loading, external type implants had significantly higher RTVs than internal type implants. In external type implants, retightening did not affect the decrease in RTV. In contrast, retightening 5 times and retightening after 10 cycles of dynamic loading was effective for maintaining RTV in internal type implants. CONCLUSION. Retightening of screws is more effective in internal type implants than external type implants. Retightening of screws is recommended in the early stage of functional loading.

Effects of counter torque and transposition (transfer) of installed implants timing on their integration in dog tibia

  • Karimi, Mohammad Reza;Fathi, Shima;Ghanavati, Farzin
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권1호
    • /
    • pp.62-68
    • /
    • 2015
  • PURPOSE. The purpose of this research was to evaluate the amount of reosseointegration after counter torquing (reverse torque) and transposing the installed implants at different times. MATERIALS AND METHODS. This study was done on ten tibiae of five cross-bred dogs. At the first day one implant was installed in each tibia. After one week half of the implants were randomly counter torqued (1WCT) and the other half were explanted and reimplanted in a new juxtaposition site (transposed)(1WT). At the same time three new implants were installed in each dog, one of them was considered as one week control (1WC) and remaining two as 8 week groups (8WCT&8WT). After eight weeks the 1WCT and 1WT implants were loosened by counter torque and the quantity of needed force for liberation was measured with the digital device (BGI). At the same time one implant was installed in each dog as eight week control (8WC) and the same protocol was repeated for 8 week groups after another 8 weeks. RESULTS. All implants were osseointegrated. Mean quantities of osseointegration in case groups indicated better amounts rather than control groups. CONCLUSION. Counter torque or transposition of the installed implants one week or eight weeks after the implantation did lead to osseointegration.

가토의 대퇴골에 식립한 3종류의 수산화인회석 코팅 임플란트에 대한 제거회전력 비교 연구 (Comparative study of removal torque of 3 different hydroxyapatite coated implants in the femur of rabbits)

  • 김상수;이주형;유석현;이형주;문지원;박인숙;손동석
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제37권1호
    • /
    • pp.49-53
    • /
    • 2011
  • Introduction: This study compared the strength of osseointegration as determined by the resistance to reverse torque rotation of three different hydroxyapatite coated implants in the rabbit femur model. Materials and Methods: Three hydroxyapatite coated implants (HAPTITE), Tapered Screw-Vent (TSV) and BioTite-H - were used. A total of 40 implants were placed in the femur of 20 adult male rabbits. The animals were divided into two groups. In group A (n=10); one HAPTITE was placed into each right femur and one TSV was placed into each left femur. In group B (n=10); one HAPTITE was placed into each right femur and one BioTite-H was placed into each left femur. Five rabbits of each group were sacrificed at 4 and 8 weeks. The implants were removed by reverse torque rotation using a digital torque-measuring device. A total of 40 implants in 20 rabbits were used for the removal torque measurements. Results: In the Group A, 4 weeks after implant placement, the mean removal torque for the HAPTITE and TSV was $70.7{\pm}31.6$ N cm and $28.9{\pm}15.1$ N cm, respectively. Eight weeks after implant placement, the mean removal torque for the HAPTITE and TSV was $87.9{\pm}26.2$ N cm and $54.9{\pm}22.4$ N cm, respectively. In the Group B, 4 weeks after implant placement, the mean removal torque for the HAPTITE and BioTite-H was $58.0{\pm}29.6$ N cm and $37.7{\pm}14.1$ N cm, respectively. Eight weeks after implant placement, the mean removal torque for the HAPTITE and BioTite-H was $91.4{\pm}47.1$ N cm and $30.8{\pm}9.8$ N cm. HAPTITE showed a higher removal torque than the other implants. Conclusion: These results suggest that HAPTITE increases the strength of osseointegration significantly as determined by the resistance to reverse torque rotation.

접촉상태에 있는 의 초정밀 역전방지클러치의 3D SPRAG TYPE 내구성 평가에 관한 연구 (A Study on Endurance Estimation of 3D Sprag Type Ultra Precision Reverse-Locking Clutches under Contact Condition)

  • 이상범;서정세;이석순;이태선;최중환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.1429-1433
    • /
    • 2004
  • Recently, a dangerous event occurred at the field industry and mechanical system. At developed by SUNGGOK corp. a R-L clutches of a small and high capacity serves safety device from a variety environment of mechanical system, it permits transmission of driving torque form input to output shaft in both directions of rotation, but restrains any feedback torque of the driven load from rotating the output shaft in either direction. This study was carried out to demonstrate through finite element methode and durability estimation for safety of the R-L clutches without sliding during the engagement process. As results, we organized about endurance test methode when applied rated torque.

  • PDF