• 제목/요약/키워드: Reverse Osmosis (RO) Process

검색결과 120건 처리시간 0.024초

해수담수화 공정을 위한 가스하이드레이트-역삼투 공정의 에너지 소모량 평가 (Evaluation of energy consumption of gas hydrate and reverse osmosis hybrid system for seawater desalination)

  • 유현욱;김민석;임준혁;김종하;이주동;김수한
    • 상하수도학회지
    • /
    • 제30권4호
    • /
    • pp.459-469
    • /
    • 2016
  • Gas hydrate desalination process is based on a liquid to solid (Gas Hydrate, GH) phase change followed by a physical process to separate the GH from the remaining salty water. The GH based desalination process show 60.5-90% of salt rejection, post treatment like reverse osmosis (RO) process is needed to finally meet the product water quality. In this study, the energy consumption of the GH and RO hybrid system was investigated. The energy consumption of the GH process is based on the cooling and heating of seawater and the heat of GH formation reaction while RO energy consumption is calculated using the product of pressure and flow rate of high pressure pumps used in the process. The relation between minimum energy consumption of RO process and RO recovery depending on GH salt rejection, and (2) energy consumption of electric based GH process can be calculated from the simulation. As a result, energy consumption of GH-RO hybrid system and conventional seawater RO process (with/without enregy recovery device) is compared. Since the energy consumption of GH process is too high, other solution used seawater heat and heat exchanger instead of electric energy is suggested.

가축분뇨 혐기 소화액 처리를 위한 막 증발과 역삼투 공정 성능 비교 (Comparison of membrane distillation with reverse osmosis process for the treatment of anaerobic digestate of livestock wastewater)

  • 김승환;조진우
    • 상하수도학회지
    • /
    • 제34권4호
    • /
    • pp.259-266
    • /
    • 2020
  • In this study, a pilot-scale (3 ㎥/day) membrane distillation (MD) process was operated to treat digestate produced from anaerobic digestion of livestock wastewater. In order to evaluate the performance and energy cost of MD process, it was compared with the pilot scale (10 ㎥/day) reverse osmosis (RO) process, expected competitive process, under same feed condition. As results, MD process shows stable permeate flux (average 10.1 L/㎡/hr) until 150 hours, whereas permeate flux of RO process was decreased from 5.3 to 1.5 L/㎡/hr within 24 hours. In the case of removal of COD, TN, and TP, MD process shows a high removal rate (98.7, 93.7, and 99% respectively) stably until 150 hours. However, in the case of RO process, removal rate was decreased from 91.6 to 69.5% in COD and from 93.7 to 76.0% in TP during 100 hours of operation. Removal rate of TN in RO process was fluctuated in the range of 34.5-62.9% (average 44.6%) during the operation. As a result of energy cost analysis, MD process using waste heat for heating the feed shows 18% lower cost compare with RO process. Thus, overall efficiency of the MD process is higher then that of the RO process in terms of permeate flux, removal rate of salts, and operating cost (in the case of using waste heat) in treating the anaerobic digestate of livestock wastewater.

물통합형 정삼투 시스템을 이용한 파일럿 스케일 담수 공정 모사 (Pilot-Scale Simulation of Desalination Process Using Water Integrated Forward Osmosis System)

  • 김봉철;홍승관;최준석
    • 한국물환경학회지
    • /
    • 제33권4호
    • /
    • pp.403-408
    • /
    • 2017
  • In these days, wastewater reclamation and seawater desalination play essential role in addressing the challenge of worldwide water scarcity. Particularly, reverse osmosis (RO) for seawater desalination process is commonly used due to less energy consumption than conventional thermodynamic systems. However, membrane fouling and electrical energy consumption during operation of RO system for seawater desalination haver continued to be a obstruction to its application. In this study, therefore, wastewater secondary effluent is used for osmotic dilution of seawater. Firstly, fouling behaviour of RO by simulating wastewater effluent in osmotic dilution process was measured and we calculated energy consumption of overall desalination process by theoretical equations and commercial program. Our results reveal that RO membrane fouling can be efficiently controlled by pre-treatment systems such as nano filtration (NF) or forward osmosis (FO) process. Especially FO system for osmotic dilution process is a non-pressurized membrane system and, therefore, the operating energy consumption of overall desalination system was the lowest. Moreover, fouling layer on FO membrane is comparatively weak and reversible enough to be disrupted by physical cleaning. Thus, RO system with low salinity feed water through FO process is possible as a less energy consuming desalination system with efficient membrane fouling control.

폐수의 고도처리를 위한 무산소/호기형 분리막생물반응조 - 역삼투 공정과 활성슬러지공정 - 정밀여과 - 역삼투 공정의 비교 (Comparison of Anoxic/Oxic Membrane Bioreactor - Reverse Osmosis and Activated Sludge Process-Microfiltration-Reverse Osmosis Process for Advanced Treatment of Wastewater)

  • 노성희;김선일;전홍화;송연호
    • 공업화학
    • /
    • 제17권5호
    • /
    • pp.521-526
    • /
    • 2006
  • 폐수를 재이용하기 위한 고도처리 시스템으로서 분리막 생물반응조(Membrane Bioreactor, MBR)는 기존의 활성슬러지 공정(Activated Sludge Process, ASP)에 비하여 많은 장점을 가지고 있다. 도시 하수 중에 포함된 유기물과 영양염류를 동시에 제거하기 위하여 침지형 정밀여과(Microfiltration, MF) 막을 이용한 무산소/호기(Anoxic/Oxic, A/O)형 MBR에서 투과플럭스를 $10.2L/m^2{\cdot}h$로 일정하게 유지하면서 고형물 체류시간(Solids Retention Time, SRT) 변화에 따른 막 여과 특성을 조사하였다. 실험 결과, SRT를 증가시킬수록 체외고분자물질(Extracellular Polymeric Substances, EPS)내 단백질/탄수화물(Protein/Carbohydrate, P/C) 비가 높아져서 막 오염이 빠르게 진행되었다. A/O MBR에 RO막을 결합한 A/O MBR-RO 공정을 폐수의 고도처리에 적용하고자 하였으며, 성능평가를 위해 A/O MBR-RO 공정과 기존의 활성슬러지 공정에 MF와 RO막을 결합한 ASP-MF-RO 공정의 유기물 및 영양염류 제거율을 비교하였다. 실험 결과 A/O MBR-RO 공정이 ASP-MF-RO 공정보다 더 우수한 처리효율을 나타내었다.

해수담수화플랜트에서 가스 하이드레이트 공정 도입을 통한 역삼투 공정의 에너지 절감 효과 (Effect of gas hydrate process on energy saving for reverse osmosis process in seawater desalination plant)

  • 김수한;임준혁
    • 상하수도학회지
    • /
    • 제27권6호
    • /
    • pp.771-778
    • /
    • 2013
  • Gas hydrate (GH) process is a new desalination technology, where GH is a non- stoichiometric crystalline inclusion compounds formed by water and a number of gas molecules. Seawater GH is produced in a low temperature and a high pressure condition and they are separated from the concentrated seawater. The drawback of the GH process so far is that salt contents contained in its product does not meet the fresh water quality standard. This means that the GH process is not a standalone process for seawater desalination and it needs the help of other desalting process like reverse osmosis (RO). The objective of this study is to investigate the effect of GH process on energy saving for RO process in seawater desalination. The GH product water quality data, which were obtained from a literature, were used as input data for RO process simulation. The simulation results show that the energy saving effect by the GH process is in a range of 68 % to 81 %, which increases as the salt removal efficiency of the GH process increases. Boron (B) and total dissolved solids (TDS) concentrations of the final product of the hybrid process of GH and RO were also investigated through the RO process simulation to find relavant salt rejection efficiency of the GH process. In conclusion, the salt rejection efficiency of the GH process should exceed at least 78% in order to meet the product water quality standards and to increase the energy saving effect.

역삼투막을 이용한 가스하이드레이트 해수담수화 공정 내 용존 가스의 제거 가능성 평가 (Removal potential of dissolved gas in gas hydrate desalination process by reverse osmosis)

  • 유현욱;김민석;임준혁;김종하;이주동;김수한
    • 상하수도학회지
    • /
    • 제30권6호
    • /
    • pp.635-643
    • /
    • 2016
  • Gas hydrate (GH)-based desalination process have a potential as a novel unit desalination process. GHs are nonstoichiometric crystalline inclusion compounds formed at low temperature and a high pressure condition by water and a number of guest gas molecules. After formation, pure GHs are separated from the remaining concentrated seawater and they are dissociated into guest gas and pure water in a low temperature and a high pressure condition. The condition of GH formation is different depending on the type of guest gas. This is the reason why the guest gas is a key to success of GH desalination process. The salt rejection of GH based desalination process appeared 60.5-93%, post treatment process is needed to finally meet the product water quality. This study adopted reverse osmosis (RO) as a post treatment. However, the test about gas rejection by RO process have to be performed because the guest gas will be dissolved in a GH product (RO feed). In this research, removal potential of dissolved gas by RO process is performed using lab-scale RO system and GC/MS analysis. The relation between RO membrane characteristics and gas removal rate were analyzed based on the GC/MS measurement.

정밀여과·나노여과·역삼투 막에 의한 세슘과 요오드의 제거 (Removal of cesium(137Cs) and iodide(127I) by microfiltration·nanofiltration·reverese osmosis membranes)

  • 채선하;김충환
    • 상하수도학회지
    • /
    • 제28권5호
    • /
    • pp.549-554
    • /
    • 2014
  • This study was evaluated the applicability of the membrane filtration process (Micro Filtration (MF), nanofiltration membranes (NF), reverse osmosis (RO)) on the major radioactive substances, iodine ($I^-$) and cesium ($Cs^+$) using membranes produced in Korea and domestic raw water. Iodine ($I^-$) or cesium ($Cs^+$) in the microfiltration membrane (MF) process could not be expected removal efficiency by eliminating marginally at the combined state with colloidal and turbidity material. At the domestic raw water (lake water, turbidity 1.2 NTU, DOC 1.3 mg/L) conditions, nanofiltration membrane (NF) and reverse osmosis (RO) showed a high removal rate of about 88 ~ 99% for iodine ($I^-$) and cesium ($Cs^+$) and likely to be an alternative process for the removal of radioactive material.

Application of Membrane Processes to the Treatment of Wastewaters in Japan

  • Yamamoto, Kazuo
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1995년도 제3회 하계분리막 Workshop (환경과 막분리 공정의 역할)
    • /
    • pp.39-50
    • /
    • 1995
  • The membrane processes that are commonly uscd in water and wastewater treatment are reverse osmosis (Ro), ultrafiltration (UF) and microfiltration (MF), which utilize pressure differentials. There is also nano-filtration (NF), or low-pressure reverse osmosis, which is positioned midway between conventional reverse osmosis and ultrafiltration. Reverse osmosis membranes reject dissolved ions, while ultrafiltration can be used to reject relatively larger molecules, such as protein, polysacchalides and so on. Microfiltration is capable of eliminating particles at submicron level. This paper summarizes the characteristics of MSAS process first, as it is the main membrane process applied to wastewater treatment. Two successful examples of the applications, the cases of individual building reuse system and nightsoil treatment, are then shown. The latest trend of new membrane applications, i.e., immersed-type MSAS is also introduced.

  • PDF

방사성이온으로 오염된 물의 역삼투막공정을 이용한 이온제거 (Ions Removal of Contaminated Water with Radioactive Ions by Reverse Osmosis Membrane Process)

  • 신도형;정성일;임지원
    • 멤브레인
    • /
    • 제26권5호
    • /
    • pp.401-406
    • /
    • 2016
  • 본 연구에서는 역삼투막공정을 이용하여 수용액 중 저준위 방사성이온인 세슘과 요오드 이온을 제거하는 실험을 수행하였다. 국내에서 생산되는 역삼투막모듈 두 가지와 그리고 폐모듈 세정한 후 세슘과 요오드 이온에 대한 제거성능을 비교하였다. 공급수의 농도와 압력을 달리하여 실험을 진행한 결과, 세 가지 모듈 모두 세슘에 비해 요오드의 제염계수가 높은 것을 알 수 있었으며, 특히, 세정한 모듈은 요오드에 대한 제염계수가 1140으로 확인되었다. 대체적으로 실험조건이 고압일 때보다 저압일 때 제염성능이 좋은 것으로 나타났으며 이는 저압조건에 가까운 압력을 갖는 수도수에 직접 모듈을 설치할 경우에도 사용이 가능하리라 판단되었다. 또한 EDTA와 SBS, NaOH, 마이크로버블 등을 사용하여 세정한 막의 제염성능이 세정 전의 제염성능보다 높아졌으며 저압, 저농도 조건에서 요오드에 대한 회수율이 세정 후에 6.3% 증가한 결과를 얻었다.

Osmotic Sink Reverse Osmosis Process를 이용한 에탄올의 농축특성에 관한 연구 (A Study on the Ethanol Concentration by Osmotic Sink Reverse Osmosis Process)

  • 이광현;민병렬
    • 멤브레인
    • /
    • 제2권1호
    • /
    • pp.33-48
    • /
    • 1992
  • 역삼투공정과 비교하여 효율적인 농축공정인 OSRO공정에 의한 농축공정을 개발하여 에탄올 농축에 적용한 결과 역삼투공정에 비하여 높은 에탄올 농축효과를 얻었으며, 에탄올 분리효과가 뛰어난 OSRO용 막의 배발 및 농축장치를 다단으로 사용할 경우 산업화가 가능하다는 결과를 얻었다. 역삼투공정에 대한 OSRO공정의 농축도차($DC_{OSRO}-DC_{RO}$)는 전 실험범위에서 0보다 큰 값을 보이므로 에탄올 농축에 있어서 OSRO공정이 역삼투공정에 비해 효과적임을 확인하였다. OSRO공정에서 공급용액의 농도 및 부피유속이 감소하고 적용압력이 증가하는 것이 조업조건으로서 유리하였다. OSRO공정에 대한 이론식의 수치모사에 의한 해석적 결과로부터 단수가 증가할 수록 역삼투공정 및 OSRO공정의 농축도값은 커짐을 알 수 있었고, 같은 단내에서는 적용압력이 상승함에 따라 농축도값은 증가하는 경향을 보였다. 또한 수치모사에 의한 농축도 이론치는 실험치와 약 15% 이내에서 일치하였다. 농축도는 적용압려과 osmotic sink solution의 부피유속에는 비례하여 증가하며, 공급액 농도와 부피유속에 대해서는 감소함을 알 수 있었으며, 본 연구에서는 실험범위외의 수치모사에 의한 농축도 이론치도 제시하였다.

  • PDF