Ions Removal of Contaminated Water with Radioactive Ions by Reverse Osmosis Membrane Process  

Shin, Do Hyoung (Department of Advanced Materials and Chemical Engineering, Hannam University)
Cheong, Seong Ihl (Department of Advanced Materials and Chemical Engineering, Hannam University)
Rhim, Ji Won (Department of Advanced Materials and Chemical Engineering, Hannam University)
Publication Information
Membrane Journal / v.26, no.5, 2016 , pp. 401-406 More about this Journal
Abstract
In this study, we have investigated the removal of the low level radioactive ions of Cs and I in water by the reverse osmosis (RO) process. The two RO modules produced in domestic region and the waste RO module after the cleaning process were selected. Then we compared removal performance of both Cs and I. The experiments are conducted by varying the concentration of feed, the pressure. As a results, it was confirmed that all three modules are higher I decontamination factor than Cs. And particularly, for the cleaned RO module, its decontamination factor of I was 1140. Since the results at low pressure condition were better than that at high pressure conditions, the use of the direct installation of RO modules on the tap water might be possible. In addition, it was confirmed that the waste RO module after cleaning process using EDTA, SBS and NaOH, increased the decontamination performance better than before cleaning, in particular, the recovery ratio after cleaning was 6.3% higher.
Keywords
radioactive ions; Cs(cesium); I(iodine); reverse osmosis process; membrane cleaning; decontamination ratio;
Citations & Related Records
Times Cited By KSCI : 5  (Citation Analysis)
연도 인용수 순위
1 K. Scott, "Handbook of industrial membranes", pp. 489-497, Elsevier Advanced Technology, Oxford, UK (1995).
2 J. Gilron, S. Belfer, P. Vaisanen, and M. Nystorm, "Effects of surface modification on antifouling and performance properties of reverse osmosis membranes", Desalination, 140, 167 (2001).   DOI
3 D. H. Hellmann, H. Rosenberger, and E. F. Tusel, "Saving of energy and cost in seawter desalination with speed controlled pumps", Desalination, 139, 7 (2001).   DOI
4 H. Yamamura, M. Kurihara, and K. Maeda, "Apparatus and method for multistage reverse osmosis separation" US Patent 6,187,200, February 13 (2001).
5 C. E. Reid and E. J. Breton, "Water and ion flow across cellulosic membranes", J. Appl. Polym. Sci., 1, 133 (1959).   DOI
6 S. Loeb and S. Sourirajan, "High flow porous membranes for separating water from saline solutions", US Patent 3,133,132 A, May 12 (1964).
7 S. N. Gaeta, E. Petrocchi, E. Nergi, and E. Drioli, "Chlorine resistance of polypiperazineamide membranes and modules", Desalination, 83, 383 (1991).   DOI
8 M. Kurihara, T. Uemura, Y. Himeshima, K. Ueno, and R. Bairinji, "Development of crosslinked aromatic polyamide composite reverse osmosis membrane, J. Chem. Soc. Jpn., 2, 97 (1994).
9 N. W. Kim and S. S. Kim, "Recent trend of reverse osmosis membrane development", Membr. J., 10, 1 (2000).
10 R. Singo, "Polyamide polymer solution behaviour under chlorination", J. Membr. Sci., 88, 285 (1994).   DOI
11 E. H. Cho, S. I. Cheong, and J. W. Rhim, "Study on the fouling reduction of the RO membrane by the coating with an anionic polymer", Membr. J., 22, 481 (2012).
12 N. M. Farhat, M. Staal, S. S. Bucs, M. C. M. Van Loosdrecht, and J. S. Vrouwenvelder, "Spatial heterogeneity of biofouling under different cross-flow velocities in reverse osmosis membrane systems", J. Mem. Sci., 520, 964 (2016).   DOI
13 N. W. Kim and S. S. Kim, "The characteristics of seawater RO membrane for high recovery system", Membr. J., 12, 182 (2002).
14 D. E. Sachit and J. N. Veenstra, "Analysis of reverse osmosis membrane performance during desalination of simulated brackish surface waters", J. Mem. Sci., 453, 136 (2014).   DOI
15 I. H. Kim, E. H. Ji, J. W. Rhim, and S. I. Cheong, "Studies on the fouling reduction through the coating of poly (vinyl alcohol) on polyamide reverse osmosis membrane surfaces", Membr. J., 22, 272 (2012).
16 N. W. Kim, "Study of surface properties on fouling resistance of reverse osmosis membranes", Membr. J., 12, 28 (2002).
17 D. Rana, T. Matsuura, M. A. Kassim, and A. F. Ismail, "Radioactive decontamination of water by membrane processes-A review", Desalination, 321, 77 (2013).   DOI
18 D. H. Shin, J. W. Rhim, S. K. Park, C. H. Seo, and H. H. Park, "How to remove radioactive ions in radioactive waste", Membr. J., 25, 478 (2015).   DOI