• Title/Summary/Keyword: Reverse Control

Search Result 1,136, Processing Time 0.034 seconds

Reverse effects of electroacupuncture on xylazine analgesia in goats (염소의 xylazine 진정(鎭靜)에 대한 전침자극(電針刺戟)의 길항효과(拮抗效果))

  • Seo, Kang-moon;Yoon, Jung-hee;Cheong, Jong-tae;Chang, Kwang-ho;Nam, Tchi-chou
    • Korean Journal of Veterinary Research
    • /
    • v.32 no.4
    • /
    • pp.683-688
    • /
    • 1992
  • This study was performed to investigate the reverse effects of Jen Chung electroacupuncture at 10 and 30 min after xylazine administration(0.1mg/kg) in goats. In the group of electroacupuncture at 30 min after xylazine administration, MAT and MWT were markedly shorter than in control and in 10 min after xylazine administration. The RR intervals were continuously increased in control and in the group of electroacupuncture at 10 min after xylazine administration, but in the group of electroacapuncture at 30 min after xylazine administration significantly reduced from about 45 min. The frequency(cps) of EEG was recovered to normal pattern after 90 min in the group of electroacupuncture at 30 min after xylazine administration, but considerably delayed in control and in the group of electroacupuncture at 10 min. Respiratory rates tended to be somewhat decreased and then gradually increased in all groups. In control, there were shown cycloapneustic respirations but no in the electroacupuncture groups. It was turned out to be that the electroacupuncture stimulation of Jen Chung at 30 min after xylazine administration was effective for the reverse of the xylazine analgesia.

  • PDF

Feeder Loop Line Control for the Voltage Stabilization of Distribution Network with Distributed Generators

  • Jeong, Bong-Sang;Chun, Yeong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.1-5
    • /
    • 2014
  • When renewable sources are connected to the distribution network in the form of a distributed generators(DGs), the effect of intermittent output appears as voltage fluctuation. The surplus power at the consumer ends results in the reverse power flow to the distribution network. This reverse power flow causes several problems to the distribution network such as overvoltage. Application of the reactive power control equipment and power flow control by means of BTB inverter have been suggested as the general solutions to overcome the overvoltage, but they are not economically feasible since they require high cost devices. Herein, we suggest the feeder loop line switch control method to solve the problem.

The effect of imperfect power control on the capacity of reverse channel in cellular CDMA system with antenna arrays (안테나 배열을 이용한 CDMA 셀룰라 시스템에서 불완전 전력제어가 역방향 채널 용량에 미치는 효과)

  • 김씨알;오성근
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.2
    • /
    • pp.471-482
    • /
    • 1996
  • In this paper, we analyze the effect of imperfect power control on the capacity of the reverse channel in CDMA cellular system with antenna arrays in the base station. For imperfect power control, we assume that the received power at the base station from the users within each cell has log-normal distribution, and we also consider the effect of imperfect power control of co-channel interferences which arise from both its own cell and outer cells. From the result of numerical analysis, we show that the degree of power control gives a great influence on the capacity of CDMA celluar system with antenna arrays, and also that antenna arrays at the base station can improve greatly the system capacity even when the power control is imperfect.

  • PDF

Application of Reverse Engineering System for Improvement of Curl Distortion in Stereolithography Process (광조형 공정시 휨에 의한 변형을 개선하기 위한 역설계 시스템의 적용)

  • Che, Woo-Seong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.8 no.4
    • /
    • pp.7-13
    • /
    • 2009
  • The slender device(long length and thin width) manufactured by stereolithography process suffers from large curl distortion. This paper adapts two control parameters such as a critical exposure and a penetration depth. The measurement of the test parts dimension are carried out by reverse engineering method with the optical 3-dimensional measurement equipment. We investigate how each parameter contributes to the part accuracy and estimates the optimal set of parameters which minimizes the dimensional error of the test parts. Finally, As being an the RAM slot as being an example of the slender device, the RAM slot is made with the optimal values of control parameter and the results are investigated

  • PDF

Micronucleus Test in Bone Marrow Cells and Bacterial Reverse Mutation Assay of HMC05 (HMC05의 경구투여 소핵시험 및 복귀돌연변이 시험)

  • Shin, Heung-Mook
    • The Korea Journal of Herbology
    • /
    • v.25 no.2
    • /
    • pp.137-144
    • /
    • 2010
  • Objectives : We investigated genetic toxicity of HMCO5 using the Micronucleus Test in bone marrow cells of mice and Bacterial Reverse Mutation Assay in plate incorporation method according to OECD Guidelines and KFDA Guidelines. Methods : 1. Micronucleus test: The male rats were divided into 5 groups, respectively; G(1), treated with distilled water: G(2), treated with 1250mg/kg HMC05: G(3), treated with 2500mg/kg HMC05, G(4), treated with 5,000mg/kg HMC05; G(5), treated with Cyclophosphamide $H_2O$. Sterilized distilled water and HMC05 were administered for two consecutive days. Cyclophosphamide $H_2O$ was administered once on the day of 2nd administration. 2. Bacterial Reverse Mutation Aassay: Experimental groups were divided into two groups: with S-9mix(+S) or without S-9mix(-S). Each group treated with sterilized distilled water only, HMCO5(62, 185, 556, 1,667, $5,000{\mu}g$/plate) and, positive vehicles(Sodium azide, 2-Aminoanthracene, 4-Nitroquinoline N-oxide, ICR 191), respectively. Results : HMC05 did not show any changes in the number of micronucleated polychromatic erythrocytes(MNPCE) among 200 polychromatic erythrocytes compare to negative control. However, there were significant (p<0.01) increase with CPA in MNPCE. In Bacterial Reverse Mutation Aassay, no significant increases in the number of revertant colonies compared to (삭제) negative control were detected in all concentrations of HMC05. Conclusions : These results indicate that HMC05 did not show any genotoxicity against in Micronucleus test and Bacterial Reverse Mutation Aassay.

A Code Block Cipher Method to Protect Application Programs From Reverse Engineering (응용프로그램 역분석 방지를 위한 코드블록 암호화 방법)

  • Jung, Dong-Woo;Kim, Hyong-Shik;Park, Joong-Gil
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.18 no.2
    • /
    • pp.85-96
    • /
    • 2008
  • One of the typical methods to prevent tampering and reverse engineering on executable codes is to encrypt them. This paper proposes a code block cipher method based on key chaining to encrypt the code. The block cipher by key chaining has been known to be inadequate for encrypting the code with control transfer, even though the key chaining has advantage of hiding the keys in blocks and making the individual keys different from block to block. This paper proposes a block transformation and duplication method to apply the block cipher by key chaining to the executable codes with control transfer instructions, and shows the idea works with the MIPS instruction set.

Study on methods of minimizing the reverse logistics in e-Commerce - Focused on the B2C - (전자상거래의 역물류 최소화를 위한 효율적 관리 방안 - B2C 거래를 중심으로 -)

  • Im, Yong-Taek;Seo, Seon-Ae
    • Journal of Korea Port Economic Association
    • /
    • v.24 no.3
    • /
    • pp.147-165
    • /
    • 2008
  • Since 2000, e-commerce has been increased continuously in its quantity and quality. The growth of e-commerce has resulted in some diversities of distribution channels, and its characteristics of not-spot trading and limited market scale has urged the on-line market to play a role of assistance to off-line market. e-Commerce causes not only the flow of forward logistics, but also that of reverse logistics with every purchasing, which is a very critical factor to hesitate for consumers to purchase the products as well as increase the price of the products. Concern about the reverse logistics by sellers and buyers influences the level of price and purchasing activity of consumers. This study firstly is to lift the awareness of the efficient control of reverse logistics with reviewing the recent change of logistics environment and phenomena of reverse logistics. Secondly we find the factors generating the reverse logistics and look into its questions, and thirdly offer not only the ways to minimize the phenomena of reverse logistics, but also a efficient control system for reverse logistics. We additionally aim to contribute to prevent the price of the products from rising and raise the customers' satisfaction through minimizing the phase of reverse logistics.

  • PDF

Proposed Distribution Voltage Control Method for Connected Cluster PV Systems

  • Lee, Kyung-Soo;Yamaguchi, Kenichiro;Kurokawa, Kosuke
    • Journal of Power Electronics
    • /
    • v.7 no.4
    • /
    • pp.286-293
    • /
    • 2007
  • This paper proposes a distribution voltage control method when a voltage increase condition occurs due to reverse power flow from the clustered photovoltaic (PV) system. This proposed distribution voltage control is performed a by distribution-unified power flow controller (D-UPFC). D-UPFC consists of a hi-directional ac-ac converter and transformer. It does not use any energy storage component or rectifier circuit, but it directly converts ac to ac. The distribution model and D-UPFC voltage control using the ATP-EMTP program were simulated and the results show the voltage increase control in the distribution system.

Development of New Reverse Micellar Microencapsulation Technique to Load Water-Soluble Drug into PLGA Microspheres

  • Kim Hyun Joo;Cho Mi Hyun;Sah Hong Kee
    • Archives of Pharmacal Research
    • /
    • v.28 no.3
    • /
    • pp.370-375
    • /
    • 2005
  • The objective of this study was to develop a new reverse micelle-based microencapsulation technique to load tetracycline hydrochloride into PLGA microspheres. To do so, a reverse micellar system was formulated to dissolve tetracycline hydrochloride and water in ethyl formate with the aid of cetyltrimethylammonium bromide. The resultant micellar solution was used to dissolve 0.3 to 0.75 g of PLGA, and microspheres were prepared following a modified solvent quenching technique. As a control experiment, the drug was encapsulated into PLGA microspheres via a conventional methylene chloride-based emulsion procedure. The micro­spheres were then characterized with regard to drug loading efficiency, their size distribution and morphology. The reverse micellar procedure led to the formation of free-flowing, spherical microspheres with the size mode of 88 ~m. When PLGA microspheres were prepared follow­ing the conventional methylene chloride-based procedure, most of tetracycline hydrochloride leached to the aqueous external phase: A maximal loading efficiency observed our experimental conditions was below $5\%$. Their surfaces had numerous pores, while their internal architecture was honey-combed. In sharp contrast, the new reverse micellar encapsulation technique permitted the attainment of a maximal loading efficiency of 63.19 $\pm$$0.64\%$. Also, the microspheres had smooth and pore-free surfaces, and hollow cavities were absent from their internal matrices. The results of this study demonstrated that PLGA microspheres could be successfully prepared following the new reverse micellar encapsulation technique.

PEMFC performance on reverse voltage by fuel starvation (연료 부족에 의한 고분자전해질형 연료전지의 역전압 성능)

  • Lee, Hung-Joo;Song, Hyun-Do;Kim, Jun-Bom
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.17 no.2
    • /
    • pp.133-140
    • /
    • 2006
  • The performance of proton exchange membrane fuel cell was decreased by reverse voltage using fuel starvation. Performance decrease in local area could be affected by duration and extent of reverse voltage. Hydrogen and air stoichiometic ratio was used to find the experimental condition of abrupt voltage decrease. LabVIEW was used to make control logic of automatic load off system in preset voltage. Reverse voltage experiment was done down to -1.2 V at constant current condition. When fuel cell voltage was reached to preset voltage, electronic load was disconnected to make open circuit voltage for 1 minute. Fuel cell performance was checked every 5 cycle and the degree of performance decrease and/or recovery was estimated. Ohmic resistance and charge transfer resistance were increased and platinum surface area was reduced 41% after reverse voltage experiment.