• Title/Summary/Keyword: Reverse Control

Search Result 1,136, Processing Time 0.028 seconds

Development of a Combine HST Electronic Control System (I) - Indoor Tests for Control Characteristics - (콤바인 HST 전자제어시스템 개발 (I))

  • Seo, Sin-Won;Huh, Yun-Kun;Lee, Je-Yong;Lee, Chang-Kyu
    • Korean Journal of Agricultural Science
    • /
    • v.37 no.2
    • /
    • pp.295-302
    • /
    • 2010
  • Electro-hydraulic transmission (HST) and an electronic control system was designed, and performance of the components were investigated through indoor tests. When input values for HST swash plate control were given at 3 levels (5, 10, 13 degrees) in forward and reverse directions, the errors were less than 0.6 degrees. Response time was in ranges of 0.14 ~ 0.16 s and 0.16 ~ 0.2 s for forward and reverse direction controls while driving, and the values were 0.23 ~ 0.25 s and 0.18 ~ 0.23 s at static condition, respectively. Similar experiments for left and right steering resulted errors less than 0.5 degrees. Resonse time was in ranges of 0.16 ~ 0.22 s and 0.11 ~ 0.23 s for left and right turns while driving, and the values were 0.07 ~ 0.21 s and 0.09 ~ 0.14 s at static condition, respectively. From frequency response experiments, control system appeared to follow sine waves appropriately at frequencies less than 0.8 Hz with gain of 0.11 dB and 0.09 dB for forward and reverse direction controls, respectively, and the gain decreased above the frequency. Phase difference showed a gradual increase and were less than 45 degree up to 0.8 Hz. Similar experiments for left and right streering showed that the control system appeared to follow sine waves appropriately at frequencies less than 0.8 Hz with gain of 0.28 dB and 0.26 dB for left and right steering controls, respectively, and the gain decreased above the frequency. Phase difference showed a gradual increase and were less than 45 degree up to 0.8 Hz, which was the same as for the forward and reverse controls.

Development of an automatic steam generator level control logic at low power (저 출력시 증기발생기 수위의 자동제어논리 개발)

  • Han, Jae-Bok;Jung, Si-Chae;Yoo, Jun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.601-604
    • /
    • 1996
  • It is well known that steam generator water level control at low power operation has many difficulties in a PWR (pressurized water reactor) nuclear power plant. The reverse process responses known as shrink and swell effects make it difficult to control the steam generator water level at low power. A new automatic control logic to remove the reverse process responses is proposed in this paper. It is implemented in PLC (programmable logic controller) and evaluated by using test equipment in Korea Atomic Energy Research Institute. The simulation test shows that the performance requirements is met at low power (below 15%). The water level control by new control logic is stabilized within 1% fluctuation from setpoint, while the water level by YGN 3 and 4 control logic is unstable with the periodic fluctuation of 25% magnitude at 5% power.

  • PDF

A Compacted In-line Wet Etch/Cleaning System With a Reverse Moving Control System

  • Im, Seung-Hyeok;Cho, Eou-Sik;Kwon, Sang-Jik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.863-866
    • /
    • 2008
  • For the cost reduction in the fabrication of display panels, a reverse moving system was equipped to a compacted in-line wet etch/cleaning system. For the effect of the alternating movement of substrate on the wet etch process, ITO layers were etched in various moving modes of substrates and the results were compared and analyzed.

  • PDF

An $E_{b}$/$N_{o}$ Eestimation method in DS/CDMA systems with pilot signal (PILOT 신호가 있는 DS/CDMA 시스템의 $E_{b}$/$N_{o}$ 추정 방법)

  • 구준모;김제우
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.3
    • /
    • pp.562-570
    • /
    • 1997
  • In Direct Sequence Code Division Multiple Access(DS/CDMA) communication systems, it is important to contraol the power of reverse link channel evenly for overall channel capacity. To control the reverse link powers efficiently, it is necessary to estimate signal quality of each reverse link channel. In this paper, we discuss a method to estimate the signal-to-noise ratio(SNR) for each channel by measuring the powers of pilot and noises. Computer simulations are done to show the effectiveness of the scheme.

  • PDF

Analysis and Process Design of Hot Pipe Bending Process With Small Bending Radius (작은 곡률반경 파이프 벤딩을 위한 열간 파이프 벤딩공정 해석 및 설계)

  • 류경희;김동진;김병민;이동주
    • Transactions of Materials Processing
    • /
    • v.10 no.4
    • /
    • pp.329-337
    • /
    • 2001
  • The finite element simulation model and the program to calculate the reverse moment have been developed to analyse the stress state and deformation of pipe bending using local induction heating with small bending radius in this study. The reverse moment that is to be applied on the bending arm to control the wall thinning ratio of the bending outside to within a particular value. Even though the demand of pipes with small bending radius is increasing in power plants and ship buildings, the welded elbows are still widely used. The bending process with or without a reverse moment acting on the bending arm has been simulated. The reverse moments calculated from the developed program are in good agreement with the finite element simulations and the experiments.

  • PDF

Capacity comparison of different transmission types on the reverse link for wideband DS-CDMA cellular system (광대역 DS-CDMA 셀룰라 시스템의 역방향 링크에서 용량비교)

  • 임광재;곽경섭
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.3
    • /
    • pp.571-579
    • /
    • 1997
  • There are some transmission types on the reverse link of wideband DS-CDMA cellular system. The configurations of logical channels on the reverse link may be different dependent upon the transmission methods of reverse pilot or control signaling. In this paper, we present three transmission types on the wideband DS-CDMA reverse link; no-pilot system, pilot-channel aided system and pilot-symbol aided system. And we compare the performance of three systems in terms of capacity and cell coverage. The pilot-symbol aided system is shown to have the better performance than the pilot-channel aided system in both capacity and cell coverage.

  • PDF

Performance of Parallel Interference Cancellation with Reverse-Link Synchronous Transmission Technique for DS-CDMA System in Multipath Fading Channels with Imperfect Power Control (불완전 전력 제어와 다중 경로 페이딩 채널에서 DS-CDMA 시스템을 위한 역방향링크 동기식 전송을 채용하는 병렬식 간섭 제거기의 성능)

  • Hwang Seung-Hoon;Kim Yong-Seok;Rhee Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.11
    • /
    • pp.87-92
    • /
    • 2005
  • This paper analyzes the performance for an improved multistage parallel interference cancellation (PIC) technique with a reverse-link synchronous transmission technique (RLSTT) for DS-CDMA system in a frequency-selective Rayleigh fading channel with an imperfect power control scheme. The performance degradation due to power control error (PCE), which is approximated by a log-normally distributed random variable, is estimated as a function of the standard deviation of the PCE. The uncoded bit error performance is evaluated in order to estimate the system capacity. Comparing with the conventional one-stage PIC system, we show achievable gain around $60\%$ by the RLSTT even in the presence of PCE. We conclude that the capacity can be further improved via RLSTT, which alleviates the detrimental effects of the PCE

Design and Fabrication of a Digital Protection Relay for Reverse-Open Phase (디지털 역결상 보호 계전기의 설계 및 제작)

  • Kim, Woo-Hyun;Kil, Gyung-Suk;Kim, Sung-Wook
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.4
    • /
    • pp.313-319
    • /
    • 2019
  • Induction motors connected with a three-phase AC system may malfunction due to reverse phase or open phase faults. Conventional overcurrent relays and overheating relays are used to prevent such accidents; however, their drawbacks include a low response speed and false operation. Therefore, in this study, a digital relay for the reverse-open phase was designed and fabricated. This relay can detect the reverse phase and open phase faults and send a trigger signal to the control circuit. The proposed relay was developed based on a microcontroller. The detection times of the reverse phase and open phase were verified as 320ms and 80ms, respectively. Compared with conventional relays that only protect the motor from one type of fault, the proposed relay can detect both, reverse phase and open phase faults. In addition, the fault detection, identification criterion, and trigger signal patterns can be modified by programming according to the requirements of users.

DUAL DUTY CYCLE CONTROLLED SOFT-SWITCHING HIGH FREQUENCY INVERTER USING AUXILIARY REVERSE BLOCKING SWITCHED RESONANT CAPACITOR

  • Bishwajit, Saha;Suh, Ki-Young;Lee, Hyun-Woo;Mutsuo, Nakaoka
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.129-131
    • /
    • 2006
  • This paper presents a new ZVS-PWM high frequency inverter. The ZVS operation is achieved in the whole load range by using a simple auxiliary reverse blocking switch in parallel with series resonant capacitor. The operating principle and the operating characteristics of the new high frequency circuit treated here are illustrated and evaluated on the basis of simulation results. It was examined that the complete soft switching operation can be achieved even for low power setting ranges by introducing the high frequency dual duty cycle control scheme. In the proposed high frequency inverter treated here, the dual mode pulse modulation control strategy of the asymmetrical PWM in the higher power setting ranges and the lower power setting ones, the output power of this high frequency inverter could introduce in order to extend soft switching operation ranges. Dual duty cycle is used to provide a wide range of output power regulation that is important in many high frequency inverter applications. It is more suitable for induction heating applications the operation and control principle of the proposed high frequency inverter are described and verified through simulated results.

  • PDF

Bacterial Reverse Mutation Test of CP pharmacopunture (세균을 이용한 CP 약침의 복귀돌연변이 시험)

  • Hwang, Ji Hye;Ku, Jaseung;Jung, Chul
    • The Journal of Korean Medicine
    • /
    • v.41 no.3
    • /
    • pp.55-65
    • /
    • 2020
  • Objectives: This study aimed to evaluate the toxicity of CP pharmacopunture using bacterial reverse mutation test. Methods: To determine the mutagenic potential of CP pharmacopunture, histidine requiring Salmonella typhimurium (TA98, TA100, TA1535, and TA1537) and tryptophan requiring Escherichia coli (WP2uvrA, pKM101) strains were used. The negative (normal saline solution) and positive (Sodium azide, 2-Nitrofluorene, 2-Aminoanthracene, 9-Aminoacridine, and 4-Nitroquinoline N-oxide) control groups were used. To determine the dose levels of the main study, a dose range-finding study was conducted. Results: As a results of the dose range-finding study, the growth inhibition by CP pharmacopunture was not evident at any dose levels in the absence and presence of metabolic activation. As a results of the main study, the mean number of revertant colonies was less than twice when compared to the negative control values at all dose levels of the CP pharmacopuncture in the presence and absence of metabolic activation, showing no dose-related increase. In the positive control group, the number of revertant colonies was markedly increased by more than twice when compared to the negative control group. Conclusion: According to the results of this study, CP pharmacopunture did not show any signs of mutagenic potential.