• Title/Summary/Keyword: Return water

Search Result 528, Processing Time 0.033 seconds

Estimation of Rainfall Erosivity in USLE (범용토양유실공식의 강우침식도 추정)

  • Kim, Chang-Wan;U, Hyo-Seop
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.4
    • /
    • pp.457-467
    • /
    • 1999
  • No complete methods for estimating soil loss, included by rain storms, from a small watershed are available yet, and the best recommended method is to use measured data from the watershed. When no measured data is available from the watershed, empirical models for estimating the soil loss, such as the Universal Soil Loss Equation(USLE), is well recommended in practice. For using this equation, it is necessary to estimated the rainfall erosivity, commonly expressed as R, of the watershed. In this study, first we collected data of the probable rainfalls with the return periods of 2, 5, 10, 20, 30, 50, 80, 100, 200, and 500-yr and with the duration hours of 0.5, 1, 2, 3, 6, 12, and 24-hr. Using this data, we calculated the design values for R for the return period of 24-hr at each major rainfall-measuring station nationwide. Then we constructed the iso-erodent map of Korea for each return period of the 24-hr design storm. This study shows that the 24-hr duration iso-erodent map of the 5-yr return period is very similar to the annual average iso-erodent map of Korea. This study also shows that the 24-hr duration R-values of a certain return period can be estimated by multiplying certain parameters, obtained from this study, to the 24-hr duration R-values for the 5-yr return period or the annual average R-values. Finally, the R-values of the design storm with the 24-hr return period obtained from this study can be used for designing the settling basins at small watersheds.

  • PDF

Estimation and evaluation on the return period of flash flood for small mountainous watersheds in the Han River basin (한강유역 산지소하천의 돌발홍수 재현기간 산정 및 평가)

  • Kim, Hwa-Yeon;Kim, Jeong-Bae;Bae, Deg-Hyo
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.4
    • /
    • pp.245-253
    • /
    • 2019
  • The objectives of this study are to estimate the return period of flash flood and evaluate its appropriateness based on the actual observation events for small mountainous watersheds in the Han River basin. For these goals, Flash Flood Guidance (FFG) was estimated from 1-hr duration Threshold Runoff (TR) and Saturation Deficit (SD) of soil moisture which was derived from Sejong University Rainfall Runoff (SURR) model. Then, the return period of flash flood was calculated by comparing the rainfall quantile to the 1-hr duration rainfall that exceeded the FFG during the past period (2002-2010). Moreover, the appropriateness of the estimated return period of flash flood was evaluated by using the observation events from 2011 to 2016. The results of the return period of flash flood ranged from 1.1 to 19.9 years with a mean and a standard deviation of 1.6 and 1.1 years, respectively. Also, the result of the appropriateness indicated that 83% of the return periods derived from observation events were within the return period of flash flood range. Therefore, the estimated return period of flash flood could be considered as highly appropriate.

A Study on Energy Reduction in an Outdoor Air Conditioning System for Semiconductor Manufacturing Cleanrooms Using Water Spray Humidification (반도체 클린룸용 외기공조시스템의 수분무 가습을 이용한 에너지절감에 관한 연구)

  • Song, Won-Il;Kim, Ki-Cheol;Yoo, Kyung-Hoon;Shin, Dae-Kun;Tae, Kyung-Eung;Kim, Yong-Sik;Park, Dug-Jun
    • Particle and aerosol research
    • /
    • v.13 no.2
    • /
    • pp.65-77
    • /
    • 2017
  • In recent large-scale semiconductor manufacturing cleanrooms, the energy consumption in outdoor air conditioning (OAC) systems to heat, humidify, cool and dehumidify outdoor air(OA) represents about 40~50 % of the total cleanroom power consumption required to maintain cleanroom environment. Therefore, the assessment of energy consumption in outdoor air conditioning systems is essential for reducing the outdoor air conditioning load for a cleanroom. In the present study, an experiment with an outdoor air flow rate of $1,000m^3/h$ was conducted to compare the energy consumption in steam humidification, simple air washer, exhaust air heat recovery type air washer and dry cooling coil(DCC) return water heat recovery type air washer OAC systems. Besides, a numerical analysis was carried out to evaluate the annual energy consumption of the aforementioned four OAC systems. It was shown that the simple air washer, exhaust air heat recovery type air washer and DCC return water heat recovery type air washer OAC systems using water spray humidification were more energy-efficient than the steam humidification OAC system. Furthermore the DCC return water heat recovery type air washer OAC system was the most energy-efficient.

Shallow-water Design Waves at Gangreung Beach through the Analysis of Long-term Measured Wave Data and Numerical Simulation Using Deepwater Wave Conditions (장기 파랑관측자료 분석 및 천해파 수치실험에 의한 강릉 해역의 천해설계파)

  • Jeong, Weon Mu;Jun, Ki Cheon;Kim, Gunwoo;Oh, Sang-Ho;Ryu, Kyong-Ho
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.5
    • /
    • pp.343-351
    • /
    • 2012
  • In this study, shallow-water design waves are calculated for the return period of 10, 20, 30, and 50 years, based on the extreme value analysis of the wave measurement data at Gangneung beach. These values are compared with the results of SWAN simulation with the boundary condition of the deep-water design waves of the corresponding return periods at the Gangneung sea area provided by the Fisheries Agency (FA, 1988) and Korea Ocean Research & Development Institute (KORDI, 2005). It is found that the shallow-water wave heights at Gangneung beach calculated by the deep-water design waves were significantly less than the observation data. As the return period becomes higher, the significant wave heights obtained by the extreme value analysis becomes higher than those computed by SWAN with the deep-water design waves of the corresponding return periods. KORDI computed the hindcast wave data from January 2004 to August 2008 by WAM with a finer-grid mesh system than those of previous studies. Comparisons of the wave hindcast results with the wave observation show that the reproducibility of the winter-season storm wave was considerably improved compared to the hindcast data from 1979 to 2003. Hereafter, it is necessary to carry out hindcast wave data for the years before 2004 using WAM with the finer-grid mesh system and to supplement the deep-water design wave.

Flood control analysis of the sea dike at estuary. (하구방조제의 홍수조절 해석)

  • 서승덕
    • Water for future
    • /
    • v.10 no.2
    • /
    • pp.113-124
    • /
    • 1977
  • Alone the southwesten coast of Korean peninsula, the extensive available arable acreages suited for forming are found in the development of tidal flats in the geographically curved bays with a motable tidal emplitude. It was found that the developments of these tidal flats cover an estimated area more than 276,000ha. In this paper, a flood control system by Pul's Storage Indication Method and Pul's Graphical Method at Return Periods-50 yrs, design rainfall-267mm per 48hrs and design flood-926c.m.s. and at 0.2meter control height above the High Water Ordinary Spring Tide Level (+11.0m) was studied. At the result, the flood demage in the reservoir at Return Periods-50 yrs and the tidal level at H.W.O.S.T.L. were satisfied to the below E.L. 11.20m (Flood Level in the reservoir). Well skilled flood control technique and management and control of draining sluice gate should be required for the disaster prevention from the flood and tide damage.

  • PDF

Analysis on Heat Supply Piping Network for Apartment House (아파트의 온수공급배관망해석)

  • 박윤철;황광일
    • Journal of the Korean housing association
    • /
    • v.13 no.6
    • /
    • pp.89-99
    • /
    • 2002
  • The purpose of this research is to analyze the characteristics of flow rate distribution in hot-water piping networks in the apartment building. A 14-story apartment house was selected as a sample building and analyzed numerically by Hardy-Cross method. Two different piping networks, one has three vertical zones and the other of a single zone with automatic balancing valves, were compared. Some of research results are as follows; As the temperature of supply hot-water increases, the flow rate of it does by buoyancy effect, but this effect is not found in the piping network with automatic balancing valves. Non-uniformity in hot-water flow distributions to all stories in the piping system of single vertical zone can be completely reformed by the installation of either manually operated or automatic balancing valves in every story.

Determine the return period of flash floods by combining flash flood guidance and best fit distribution

  • Duong, Ngoc Tien;Kim, Jeong-Bae;Bae, Deg-Hyo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.362-362
    • /
    • 2020
  • Flash flood is a dangerous weather phenomenon, affecting humans and the economy. The identification, forecast of the changing trend and its characteristics are increasingly concerned. In the world, there have many methods for determining the characteristics of flash floods, in which flash flood guidance (FFG) is a fast, effective and widely used method. The main source of flash floods is short-term rainfall. In this study, we used the data of cross-sectional measurement at the tributaries and the hourly rain data from the automatic rainfall measurement stations in the Geum river basin. Besides, we use a combination of the flash flood guidance and the best fit distribution function to estimate the repeatability of flash floods for head-water catchments in Geum river basin. In which, FFG determines the threshold of rainfall for flash floods. The study has determined the best hourly rainfall distribution function for the Geum river basin and estimated the maximum rainfall of 1hr according to the return periods.

  • PDF

Proposal and Application of Water Deficit-Duration-Frequency Curve using Threshold Level Method (임계수준 방법을 이용한 물 부족량-지속기간-빈도 곡선의 제안 및 적용)

  • Sung, Jang Hyun;Chung, Eun-Sung
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.11
    • /
    • pp.997-1005
    • /
    • 2014
  • This study evaluated hydrological drought the using the annual minimum flow and the annual maximum deficit method and proposed the new concept of water deficit-duration-frequency curves similar to rainfall intensity-duration-frequency curves. The analysis results of the annual minimum flow, the return periods of hydrological drought in the most duration of 1989 and 1996yr were the longest. The analysis results of the annual maximum deficit, the return periods of 60-days and 90-day deficit which are relatively short duration were the longest in 1995yr, about 35-year, Hydrological drought lasted longer was in 1995, the return period was about 20-year. Though duration as well as magnitude is a key variable in drought analysis, it was found that the method using the annual minimum flow duration not distinguish duration.

Distribution of Hot Tap Water Load for District Heating Substation with Hot Tap Water 2-Stage Heat Exchanger (급탕 2단열교환방식 지역난방 열사용시설의 급탕부하 분배에 관한 연구)

  • Jeong, Dong-Hwa;Kim, Joo-Wan;Baik, Young-Jin;Lee, Young-Soo;Chung, Dae-Hun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.4
    • /
    • pp.297-302
    • /
    • 2011
  • According to the standards for district heating substation established by Korea District Heating Corporation, water heating supply systems at over 150 Mcal/h capacity must employ the 2-stage heat exchanger that improves the system efficiency by reusing the heat included in the return water of district heating system already used for space heating. In this paper, the operating characteristics of the system in accordance with the load distribution of two heat exchangers for pre-heating and re-heating cold city water are investigated. The results including mass flow rate, return temperature etc. help to manage district heating system economically.

Analysis of Generalized Extreme Value Distribution to Estimate Storm Sewer Capacity Under Climate Change (기후변화에 따른 하수관거시설의 계획우수량 산정을 위한 일반극치분포 분석)

  • Lee, Hak-Pyo;Ryu, Jae-Na;Yu, Soon-Yu;Park, Kyoo-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.2
    • /
    • pp.321-329
    • /
    • 2012
  • In this study, statistical analysis under both stationary and non-stationary climate was conducted for rainfall data measured in Seoul. Generalised Extreme Value (GEV) distribution and Gumbel distribution were used for the analysis. Rainfall changes under the non-stationary climate were estimated by applying time variable (t) to location parameter (${\xi}$). Rainfall depths calculated in non-stationary climate increased by 1.1 to 6.2mm and 1.0 to 4.6mm for the GEV distribution and gumbel distribution respectively from those stationary forms. Changes in annual maximum rainfall were estimated with rate of change in the location parameter (${\xi}1{\cdot}t$), and temporal changes of return period were predicted. This was also available for re-evaluating the current sewer design return period. Design criteria of sewer system was newly suggested considering life expectance of the system as well as temporal changes in the return period.