• 제목/요약/키워드: Return flow rate

검색결과 115건 처리시간 0.03초

한냉자극(寒冷刺戟)에 대한 한국해녀의 혈관계 반응(血管系反應)에 관한 연구 (Studies on Vascular Responses to Cold Stimuli in the Korean Diving Women)

  • 백광세;김진경;한대석;강복순;홍석기
    • The Korean Journal of Physiology
    • /
    • 제3권1호
    • /
    • pp.59-66
    • /
    • 1969
  • Experiments on thermoregulatory responses to cold immersion stimulus were carried out in September, 1968 (summer studies) and February, 1969 (winter studies). Eight each of ama and control subject were selected at random from a same community in Yong-Do Island, Pusan. The results obtained are summarized as follows: 1) The rate of fall in muscle temperature of forearm during a 30 min-immersion in $6^{\circ}C$ water bath was significantly slower in the ama in winter and was about the same in the two groups in summer. However, the magnitude of change in the skin temperature and the heat fluxes observed during immersion period was not significantly different either between groups or between seasons. 2) Both finger blood flow and skin temperature during one hr-immersion in $6^{\circ}C$ water bath decreased significantly in the ama as compared to the control. The magnitude of cold-induced vasodilatation during immersion period was significantly greater in the control in winter. However, the time of onset and blood flow at onset showed no significant relation between groups. 3) The magnitude of reactive hyperemia after a 5 min-arterial occlusion in both air and $15^{\circ}C$ water bath was significantly lower in the ana than in the control. In control subjects, post-occluded blood flow in water was significantly greater than in air, while in the ama it decreased to 1/2 of control values. The time required for the return of blood flow to resting values in the air was faster in the ama than in the control but was the same in water in the two groups. 4) The results suggest that vasoconstrictor tone increased in the ama in winter, indicating the development of vascular adaptation as a part of cold acclimatization.

  • PDF

확률변동성 모형을 적용한 해운산업의 벙커가격과 환율 리스크 추정 (Application to the Stochastic Modelling of Risk Measurement in Bunker Price and Foreign Exchange Rate on the Maritime Industry)

  • 김현석
    • 한국항만경제학회지
    • /
    • 제34권1호
    • /
    • pp.99-110
    • /
    • 2018
  • 본 연구는 해운기업의 주요 비용요인 벙커 가격과 환율의 불확실성으로 인한 재무적 리스크를 수치화하는 방법론을 2010년 1월 1일부터 2018년 1월 31일까지의 일별자료를 대상으로 적용한다. 기하브라운 운동 (Geometric Brownian Motion 이하 GBM)과 이를 확장한 조건부 이분산성(heteroskedasticity) 및 점프 확산 프로세스(jump diffusion process)에 의존하는 모형으로부터 추정한 현금 흐름 리스크 추정치는 다음 세 가지 학술적 기여로 요약할 수 있다. 첫째, 운임수익률과 같은 단일 변수에 의존한 리스크 분석을 벙커가격과 환율 수익률 변동성과 같이 복합요인으로부터 발생하는 영향으로 분석을 확장하였다. 둘째, 개별기업 수준에서 벙커가격과 환율 리크스 관리의 필요성을 민감도 분석을 통해 현금흐름수준으로 제시하였다. 마지막으로 분석결과가 제시하는 리스크 규모를 근거로 해운기업은 리스크 관리를 위한 수단으로 무엇이 적절한가를 고민해야 할 필요성이 있음을 제기한다.

지붕면 유출제어를 위한 빗물의 저장-펌프 시스템 조합 결정방안 (A Determination Method of a Rainwater Retention-Pumping System Combination for Runoff Control from Building Roof Area)

  • 김영진;한무영
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2008년도 학술발표회 논문집
    • /
    • pp.495-499
    • /
    • 2008
  • 본 연구는 빗물 저장조 시스템의 유출량 변화모의를 통해 지붕면 유출제어의 가능성을 확인하고, 설계조건에 적절한 저장조(retention tank)-펌프 용량 조합의 결정방안을 제시하였다. 저장조의 운전조건을 고려한 물수지 방정식을 이용해 서울지역의 강우특성에 따른 저류량 및 첨두유출유량 변화를 모의하고, 그 결과를 강우재현기간별 저장조 용량-첨두 유출량-펌프 배수량 관계곡선 (TPP 곡선) 으로 작성하였다. 100년 빈도 첨두 유출을 지선 하수관로의 설계기준인 5년 빈도 첨두유출까지 제어할 경우, 지붕면적 $100m^2$ 당 펌프배수 용량은 $0{\sim}25{\ell}$/분, 저장조 용량은 $8.5{\sim}10m^3$으로 결정되었다. 즉, 서울지역의 지붕면적 $100m^2$ 당 적절한 저장조+펌프 용량조합은 $10m^3+0{\ell}$/분${\sim}8.5m^3+25{\ell}$/분이라고 할 수 있다. TPP 곡선을 이용하여 설계조건에 적절한 빗물 저장조-펌프의 용량조합 방안을 알 수 있었으며, 이를 이용해 현장여건에 고려한 구체적인 용량을 결정할 수 있을 것이다.

  • PDF

다목적 댐 및 다기능 보 운영을 고려한 대유역 SWAT 모형 구축기법 연구 - 남한강 유역을 대상으로 - (Large Scale SWAT Watershed Modeling Considering Multi-purpose Dams and Multi-function Weirs Operation - For Namhan River Basin -)

  • 안소라;이지완;장선숙;김성준
    • 한국농공학회논문집
    • /
    • 제58권4호
    • /
    • pp.21-35
    • /
    • 2016
  • This study is to evaluate the applicability of SWAT (Soil and Water Assessment Tool) model for multi-purpose dams and multi-function weirs operation in Namhan river basin ($12,577km^2$) of South Korea. The SWAT was calibrated (2005 ~ 2009) and validated (2010 ~ 2014) considering of 4 multi-purpose dams and 3 multi-function weirs using daily observed dam inflow and storage, evapotranspiration, soil moisture, and groundwater level data. Firstly, the dam inflow was calibrated by the five steps; (step 1) the physical rate between total runoff and evapotranspiration was controlled by ESCO, (step 2) the peak runoff was calibrated by CN, OV_N, and CH_N, (step 3) the baseflow was calibrated by GW_DELAY, (step 4) the recession curve of baseflow was calibrated by ALPHA_BF, (step 5) the flux between lateral flow and return flow was controlled by SOL_AWC and SOL_K, and (step 6) the flux between reevaporation and return flow was controlled by REVAPMN and GW_REVAP. Secondly, for the storage water level calibration, the SWAT emergency and principle spillway were applied for water level from design flood level to restricted water level for dam and from maximum to management water level for weir respectively. Finally, the parameters for evapotranspiration (ESCO), soil water (SOL_AWC) and groundwater level fluctuation (GWQMN, ALPHA_BF) were repeatedly adjusted by trial error method. For the dam inflow, the determination coefficient $R^2$ was above 0.80. The average Nash-Sutcliffe efficiency (NSE) was from 0.59 to 0.88 and the RMSE was from 3.3 mm/day to 8.6 mm/day respectively. For the water balance performance, the PBIAS was between 9.4 and 21.4 %. For the dam storage volume, the $R^2$ was above 0.63 and the PBIAS was between 6.3 and 13.5 % respectively. The average $R^2$ for evapotranspiration and soil moisture at CM (Cheongmicheon) site was 0.72 and 0.78, and the average $R^2$ for groundwater level was 0.59 and 0.60 at 2 YP (Yangpyeong) sites.

한국댐의 대용량 배수시설 및 Spillway 배수능력에 관한 조사연구 (A Study on Drainage Capability of Large Capacity Outlet and Spillway of Dams in Korea)

  • 이원환
    • 물과 미래
    • /
    • 제11권2호
    • /
    • pp.43-53
    • /
    • 1978
  • 본 연구는 국내 대댐(ICOLD규정에 의한 대댐) 647개를 대상으로 건설실적과 분류를 통하여 체계화하였으며 특히 대용량 배수설비 및 여수토의 배수능력을 진단함으로써 앞으로의 대용량 배수설비 계획방침을 제안한 것이다. 본 연구를 통하여 얻어진 성과를 요약하면 아래와 같다. 1. 국내댐의 용도별 분류로 보면 94%가 관개용댐(647개중 607개)이며 발전용댐이 2%(14개) 생활 및 공업용수댐이 26개로 4%이다. 2. 계획방류량 설정에서 관개용 댐의 spillway에서는 100년 확률홍수량을 택하고 있으며 생활 및 공업용수댐의 spillway는 200년, 발전용댐에서는 500년 또는 1,000년을 택하고 있으나 소규모 Spillway에서는 500년 이상을, 대규모 Spillway에서는 1000년 이상 또는 PMF를 택해야 할 것이다. 3. Spillway는 방재공학적 견지에서 반드시 고려되어야 하겠으며 그 기획규모를 확률년도 등급(안)을 제안하였다. 4. 몇가지 문제점을 제기하여, 앞으로의 과제로 하였다.

  • PDF

낙엽송 전간수확작업에서 HAM300을 이용한 집재작업의 작업일수 및 작업량을 고려한 경제성 분석 (Economic Evaluation of the HAM300 Yarding Operation with Tree-Length Harvesting Method in Larix kaempferi Forest Stands)

  • 이은재;임상준;이성재;한상균
    • 한국산림과학회지
    • /
    • 제109권1호
    • /
    • pp.72-80
    • /
    • 2020
  • 목재수확작업의 경제성을 분석하기 위한 방법은 기계비용법(machine rate method)과 현금흐름법(cash-flow method: CFM)으로 구분할 수 있다. 본 연구에서는 CFM을 이용하여 낙엽송 임분에서 HAM300 전간집재작업의 경제적 타당성 분석을 실시하였다. 즉, 연간 작업일수(50, 100, 150, 200일/년)와 작업 생산성 변화(효율성 40% 개선 효과)에 대하여 집재작업의 경제적 타당성을 평가하고자 하였다. 분석방법으로는 순현재가치법(net present value: NPV)과 자본회수기간법(pay-back period)을 이용하였다. 연간 작업일수가 150일 이상인 조건에서 NPV의 값이 0보다 크기 때문에 경제적 타당성이 충분한 것으로 나타났으며, 이 때 자본회수기간은 3.65년 이하로 분석되었다. 작업생산성(㎥/scheduled machine hour)이 40% 증가하는 시나리오에서는 연간 작업일수가 100일인 조건에서도 현금흐름이 안정적이며, 경제적 효과가 큰 것으로 나타났다. 하지만, 연간 작업일수가 50일 이하인 경우에는 집재작업의 수익성이 악화되어 투자에 대한 의사결정이 어려운 것으로 분석되었다. 결과적으로, HAM300 집재작업은 수익성이 있는 작업조건(연간작업일수: 100일 이상, 연간작업량: 5,000 ㎥)이 지속적으로 확보가 가능하다고 판단되는 작업조건에서 투자에 대한 결정이 이루어져야 한다.

흰쥐의 적출 작업성 심장에서 허혈성 심정지시 Fructose-1.6-diphosphate(FDP)의 심근보호 작용 (Improved Myoardial Protection by Addition of Fructose-1.6-diphosphate to Crystalloid Cardioplegic Solution in the Isolated Working Rat Heart)

  • 나국주
    • Journal of Chest Surgery
    • /
    • 제23권4호
    • /
    • pp.646-653
    • /
    • 1990
  • Currently numerous methods are in use for myocardial protection from the ravages of ischemia and hypoxia. This study was designed to compare with FDP-GIK[Group II, n=8] and GIK cardioplegic solution[Group I, n=8] in ability of myocardial protection and was examined in the isolated working rat heart subjected to long period[120 min] of hypothermic[10 - 15K] ischemic arrest with multidose[every 30 min] cardioplegic infusion. During postischemic reperfusion period 20 min, hemodynamic functions[aortic flow, coronary flow, peak aortic pressure, cardiac output, heart rate], biochemical enzymatic & electrical activities were evaluated. The time from onset of reperfusion to the return of regular sinus rhythm was significantly reduced from 87$\pm$3 sec to 17$\pm$2 sec[P<0.05]. The postischemic recovery of aortic flow was better in the group II [95.1$\pm$3.3% of its preischemic control level] than in the Group I [75.4$\pm$6.8%] [P<0.05]. Cardiac output and stroke volume was also better in the group[91.3$\pm$1.6%, 89.4$\pm$2.6%, respectively] than in the Group I [79.1$\pm$3.7%, 77.0$\pm$4.8%, respectively] [P<0. 05]. Creatine kinase leakage was also significantly reduced from 33.8$\pm$4.9 IU /10 min / gm * dry weight to 15.4$\pm$3.6 IU /10 min /gm * dry weight[P<0.05]. It is suggested that adding FDP to GIK cardioplegic solution improves its ability to protect the heart against long period of hypoxic ischemia.

  • PDF

Differences in Treatment Outcomes According to the Insertion Method Used in Extracorporeal Cardiopulmonary Resuscitation: A Single-Center Experience

  • Han Sol Lee;Chul Ho Lee;Jae Seok Jang;Jun Woo Cho;Yun-Ho Jeon
    • Journal of Chest Surgery
    • /
    • 제57권3호
    • /
    • pp.281-288
    • /
    • 2024
  • Background: Venoarterial extracorporeal membrane oxygenation (ECMO) is a key treatment method used with patients in cardiac arrest who do not respond to medical treatment. A critical step in initiating therapy is the insertion of ECMO cannulas. Peripheral ECMO cannulation methods have been preferred for extracorporeal cardiopulmonary resuscitation (ECPR). Methods: Patients who underwent ECPR at Daegu Catholic University Medical Center between January 2017 and May 2023 were included in this study. We analyzed the impact of 2 different peripheral cannulation strategies (surgical cutdown vs. percutaneous cannulation) on various factors, including survival rate. Results: Among the 99 patients included in this study, 66 underwent surgical cutdown, and 33 underwent percutaneous insertion. The survival to discharge rates were 36.4% for the surgical cutdown group and 30.3% for the percutaneous group (p=0.708). The ECMO insertion times were 21.3 minutes for the surgical cutdown group and 10.3 minutes for the percutaneous group (p<0.001). The factors associated with overall mortality included a shorter low-flow time (hazard ratio [HR], 1.045; 95% confidence interval [CI], 1.019-1.071; p=0.001) and whether return of spontaneous circulation was achieved (HR, 0.317; 95% CI, 0.127-0.787; p=0.013). Low-flow time was defined as the time from the start of cardiopulmonary resuscitation to the completion of ECMO cannula insertion. Conclusion: No statistically significant difference in in-hospital mortality was observed between the surgical and percutaneous groups. However, regardless of the chosen cannulation strategy, reducing ECMO cannulation time was beneficial, as a shorter low-flow time was associated with significant benefits in terms of survival.

Simulation analysis and evaluation of decontamination effect of different abrasive jet process parameters on radioactively contaminated metal

  • Lin Zhong;Jian Deng;Zhe-wen Zuo;Can-yu Huang;Bo Chen;Lin Lei;Ze-yong Lei;Jie-heng Lei;Mu Zhao;Yun-fei Hua
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.3940-3955
    • /
    • 2023
  • A new method of numerical simulating prediction and decontamination effect evaluation for abrasive jet decontamination to radioactively contaminated metal is proposed. Based on the Computational Fluid Dynamics and Discrete Element Model (CFD-DEM) coupled simulation model, the motion patterns and distribution of abrasives can be predicted, and the decontamination effect can be evaluated by image processing and recognition technology. The impact of three key parameters (impact distance, inlet pressure, abrasive mass flow rate) on the decontamination effect is revealed. Moreover, here are experiments of reliability verification to decontamination effect and numerical simulation methods that has been conducted. The results show that: 60Co and other homogeneous solid solution radioactive pollutants can be removed by abrasive jet, and the average removal rate of Co exceeds 80%. It is reliable for the proposed numerical simulation and evaluation method because of the well goodness of fit between predicted value and actual values: The predicted values and actual values of the abrasive distribution diameter are Ф57 and Ф55; the total coverage rate is 26.42% and 23.50%; the average impact velocity is 81.73 m/s and 78.00 m/s. Further analysis shows that the impact distance has a significant impact on the distribution of abrasive particles on the target surface, the coverage rate of the core area increases at first, and then decreases with the increase of the impact distance of the nozzle, which reach a maximum of 14.44% at 300 mm. It is recommended to set the impact distance around 300 mm, because at this time the core area coverage of the abrasive is the largest and the impact velocity is stable at the highest speed of 81.94 m/s. The impact of the nozzle inlet pressure on the decontamination effect mainly affects the impact kinetic energy of the abrasive and has little impact on the distribution. The greater the inlet pressure, the greater the impact kinetic energy, and the stronger the decontamination ability of the abrasive. But in return, the energy consumption is higher, too. For the decontamination of radioactively contaminated metals, it is recommended to set the inlet pressure of the nozzle at around 0.6 MPa. Because most of the Co elements can be removed under this pressure. Increasing the mass and flow of abrasives appropriately can enhance the decontamination effectiveness. The total mass of abrasives per unit decontamination area is suggested to be 50 g because the core area coverage rate of the abrasive is relatively large under this condition; and the nozzle wear extent is acceptable.

Impact of Working Capital Management on Firm Performance in Different Business Cycles: Evidence from Vietnam

  • NGUYEN, Co Trong
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제7권12호
    • /
    • pp.863-867
    • /
    • 2020
  • This study was conducted on financial data of 38 economic groups listed on Vietnam's stock market for the period 2009 - 2019 and it aims to provide an empirical evidence on the impact of working capital management policy on performance in all phases of the economic cycle of Vietnamese economic groups. The study uses FGLS estimation method with 2 dependent variables ROA, GOP, independent variables including INV, AR, AP, CCC, dummy variable representing different phases of the economic cycle, variables Control includes CAT, CR, LEV, SZ, GR. Research shows that the greater the level of investment by companies in liquid assets corresponding to a certain level of activity (shown by average days of inventory (INV), average days of collection. (AR), cash flow cycle (CCC)) the lower the rate of return on assets. The study also provides additional evidence of the negative effects of economic crisis on the performance of economic groups. The study also shows that the number of short-term asset cycles has a positive impact on operational efficiency, and the level of debt use has a negative impact on operational efficiency. This result implies that the managers of economic groups can increase the efficiency of businesses through a reasonable working capital policy.