• 제목/요약/키워드: Return flow rate

검색결과 115건 처리시간 0.02초

내부수익률을 이용한 수익률분석법에 대한 이해 (Understanding of a Rate of Return Analysis using an IRR)

  • 김진욱;이현주;차동수
    • 산업경영시스템학회지
    • /
    • 제25권5호
    • /
    • pp.9-14
    • /
    • 2002
  • A capital investment problem is essentially one of determining whether the anticipated cash inflows from a proposed project are sufficiently attractive to invest funds in the project. The net present value(NPV) criterion and internal rate of return(IRR) criterion are widely used as means of making investment decisions. A positive NPV means the equivalent worth of the inflows is greater than the equivalent worth of outflows, so, the project makes profit. Business people are familiar with rates of return because they all borrow money to finance ventures, even if the money they borrow is their own. Thus they are apt to use the IRR in preference to the NPV. The IRR can be defined as the discount rate that causes the net present value of a cash flow to equal zero. Why the project are accepted if the project's IRR is greater than the investor's minimum attractive rate of return\ulcorner Against the NPV, the definition cannot distinctly explain the concept of the IRR as decision criterion. We present a new definition of the IRR as the ratio of profit on the invested capital.

다공형 전열판의 회전에 의한 열교환시스템의 성능에 관한 연구(Ⅰ) - 환기측과 외기측의 풍량 변화에 대하여 - (Study on the Performance of Total Heat Exchanger with Rotating Porous Plates)

  • 조동현;임태우
    • 동력기계공학회지
    • /
    • 제9권4호
    • /
    • pp.11-17
    • /
    • 2005
  • This paper reports an experimental study on the performance evaluation of air-to-air heat exchanger with rotary type newly developed in this study. Air flow rate is varied from 10 to 120 m3/h. The range of RPM of the porous rotating discs mounted inside the heat exchanger unit is 0 to 50. The temperature of the return air side is set by adjusting heat supply at heater. The material of the porous rotating discs is cooper and its thickness is 1.0 mm. The heat transfer rate increased with the increase in air flow rate. It was found that the heat transfer rate, as the temperature of the return air side was increased, was improved due to higher temperature difference. The heat exchange performance increased with the increase in the temperature of the return air side at the conditions of the same RPM. The sensible heat exchange efficiency was maximum 68 to 76 percent, and enthalpy exchange efficiency 64 to 74 percent.

  • PDF

지역난방 아파트에 대한 난방에너지 실측 및 시뮬레이션 (Measurement and Simulation of Heating Energy for Apartments with District Heating)

  • 이은주;이두영;홍희기;김영균
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.572-578
    • /
    • 2014
  • Heating energy was measured in an apartment housing unit with a district heating system, varying the kind of hot water distributors. Ondol coils passing through a living room raised the temperature of the room where the heating was turned off. Including this characteristic of Ondol heating into the modeling, we performed simulations and showed a verification by comparison with the results of measurements. As a result, a main flow control method, which changes hot water flow rate supplied to a housing unit according to the thermal load, can reduce the supplied flow rate and lower the return temperature, compared with a constant flow method. That can result in decreased heat loss in utility-pipe conduits even though the heating energy supplied is almost the same. An outdoor reset control that raises the temperature of the supplied hot water if the outdoor temperature falls has the effect of a quicker response in heating than the reduced flow rate and return temperature.

농업유역의 논 관개 회귀수량 추정 (Estimation of irrigation return flow from paddy fields on agricultural watersheds)

  • 김하영;남원호;문영식;안현욱;김종건;신용철;도종원;이광야
    • 한국수자원학회논문집
    • /
    • 제55권1호
    • /
    • pp.1-10
    • /
    • 2022
  • 논으로 공급되는 관개용수는 필지에서의 증발산량 및 지하침투량과 용배수로를 통한 자연적 및 인위적인 배수량으로 소비된다. 관개 회귀수량은 관개를 통해 농경지에 공급된 수량 중에서 증발산에 의해 소비되지 않고 침투 또는 배수 등을 통해 하천으로 회귀되는 수량이다. 논 관개 회귀수량은 농업용수의 건전한 물순환 관리에 중요한 역할을 하며, 유역의 용수공급계획, 하천유황의 예측, 관개용수의 사용량 결정, 하천수질관리 및 농업유역의 수문모델링 등에 중요한 인자로 작용한다. 본 연구에서는 강원도 원주시 흥업저수지를 대상으로 단일 수원공 및 농업유역 단위의 회귀율을 추정하기 위하여 2017년부터 2020년까지 모니터링 및 EPA-SWMM (Environmental Protection Agency-Storm Water Management Model) 모델링을 수행하였다. 기상자료, 저수율, 관개수로 실측 유량자료를 입력하여 평야부의 관개수로 네트워크 모델 기반 SWMM 모델링을 수행하였으며, 용배수로별 공급량과 배수량을 산정하였다. 2020년 실측 저수율, 용배수로 유량 모니터링 데이터를 활용하여 SWMM 모델의 적용성을 검증하였으며, 평야부 수혜면적의 용배수로 네트워크를 구성하여 저수지로부터 공급된 관개량 중 배수로를 통해 하천으로 유입되는 신속회귀수량 및 회귀율을 추정하였다. 흥업저수지의 회귀수량 산정 결과 2017년부터 2020년까지의 연평균 신속회귀수량 및 회귀율은 각각 2,407,000 m3, 53.1%로 추정되었으며, 대상 저수지의 시점부 및 취입보 공급량, 수로부 배수량, 회귀수량 산정 결과를 활용하여 소규모 단일유역인 농촌유역의 물순환 특성 분석을 수행하였다.

유역모델을 이용한 농업용수 신속회귀수량 산정 연구 (A study on estimating the quick return flow from irrigation canal of agricultural water using watershed model)

  • 이지완;정충길;김다예;맹승진;정현식;조영식;김성준
    • 한국수자원학회논문집
    • /
    • 제55권5호
    • /
    • pp.321-331
    • /
    • 2022
  • 본 연구에서는 유역단위의 물수지 분석과 농업용수의 수문학적 매커니즘을 모의 할 수 있는 유역 모델링 방법을 이용하여 회귀수량 산정기법을 제시하고자 하였다. SWAT 모델을 이용하여 영산강수계 대표적인 농업지역인 만봉천 표준유역 (97.34 km2)에 대해 담수 논 모의가 고려된 유역물수지 분석을 실시하였다. 회귀수량 산정에 앞서, 나주 유량관측소의 일 유량 자료를 이용하여 SWAT을 검·보정하였다. R2, Nash-Sutcliffe Efficiency (NSE), Root-Mean-Square Error (RMSE)는 각각 0.73, 0.70, 0.64 mm/day으로 분석되었다. 3년 동안(2015~2017) 모의 결과를 토대로 관개기간(4/1~9/30)에 대한 신속 회귀수량과 공급량 대비 회귀율을 산정하였고, 평균 53.4%로 분석되었다. 본 연구에서 제시한 유역 회귀수량 모델링 기법은 향후 합리적인 유역물관리를 위한 최적 농업용수 공급방안에 대한 기초자료 구축에 활용될 수 있다.

아파트의 온수공급배관망해석 (Analysis on Heat Supply Piping Network for Apartment House)

  • 박윤철;황광일
    • 한국주거학회논문집
    • /
    • 제13권6호
    • /
    • pp.89-99
    • /
    • 2002
  • The purpose of this research is to analyze the characteristics of flow rate distribution in hot-water piping networks in the apartment building. A 14-story apartment house was selected as a sample building and analyzed numerically by Hardy-Cross method. Two different piping networks, one has three vertical zones and the other of a single zone with automatic balancing valves, were compared. Some of research results are as follows; As the temperature of supply hot-water increases, the flow rate of it does by buoyancy effect, but this effect is not found in the piping network with automatic balancing valves. Non-uniformity in hot-water flow distributions to all stories in the piping system of single vertical zone can be completely reformed by the installation of either manually operated or automatic balancing valves in every story.

Flow Investigations in the Crossover System of a Centrifugal Compressor Stage

  • Reddy, K. Srinivasa;Murty, G.V. Ramana;Dasgupta, A.;Sharma, K.V.
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권1호
    • /
    • pp.11-19
    • /
    • 2010
  • The performance of the crossover system of a centrifugal compressor stage consisting of static components of $180^{\circ}$ U-bend, return channel vanes and exit ducting with a $90^{\circ}$ bend is investigated. This study is confined to the assessment of performance of the crossover system by varying the shape of the return channel vanes. For this purpose two different types of Return Channel Vanes (RCV1 and RCV2) were experimentally investigated. The performance of the crossover system is discussed in terms of total pressure loss coefficient, static pressure recovery coefficient and vane surface pressure distribution. The experimentation was carried out on a test setup in which static swirl vanes were used to simulate the flow at the exit of an actual centrifugal compressor impeller with a design flow coefficient of 0.053. The swirl vanes are connected to a mechanism with which the flow angle at the inlet of U-bend could be altered. The measurements were taken at five different operating conditions varying from 70% to 120% of design flow rate. On an overall assessment RCV1 is found to give better performance in comparison to RCV2 for different U-bend inlet flow angles. The performance of RCV2 was verified using numerical studies with the help of a CFD Code. Three dimensional sector models were used for simulating the flow through the crossover system. The turbulence was predicted with standard k-$\varepsilon$, 2-equation model. The iso-Mach contour plots on different planes and development of secondary flows were visualized through this study.

에어믹서가 설치된 공조기 혼합실 내의 온도분포에 관한 실험적 연구 (An Experimental Study of Temperature Profiles in Mixing Zone of AHU with an Air Mixer)

  • 박권종;이석준;장영근
    • 설비공학논문집
    • /
    • 제18권12호
    • /
    • pp.999-1006
    • /
    • 2006
  • A study of temperature profiles in mixing zone of AHU (air handling unit) can contribute greatly to enhance performance of AHU system, so the study on the temperature distribution between RA (return air) and OA (outdoor air) is important to analyze the mixing characteristics in a mixing zone of AHU. Accordingly, the temperature profiles during RA (return air) and OA (outdoor air) supply process into mixing zone of AHU with an air mixer are studied experimentally. The effect of air mixer, OA temperature and RA/OA flow rate are studied in detail. In this study, the results show that the mixing efficiency is all high for installed the air mixer. The more OA temperature increase and OA flow rate decrease, the more mixing efficiency is high.

물수지분석 기법에 의한 논에서의 회귀율 조사분석 (Return flow analysis of paddy field by water balance method)

  • 정상옥;손성호
    • 한국농공학회지
    • /
    • 제43권2호
    • /
    • pp.59-68
    • /
    • 2001
  • A water balance analysis was performed for a paddy field neighboring the Dongchang stream, downstream of the Unmun reservoir, which is constructed for the urban water supply. Daily rainfall data were collected and irrigation water flow rate, drainage flow rate, evaportranspiration, infiltration, and piezometeric head were measured in the field. The flow rates were continuously observed by water level logger during the growing season. The evaportranspiration and the infiltration were measured by N-type depletion meter and cylindrical infiltrometer, respectively. PVC pipes with 12mm diameter were used for piezometric head measurement. Total Irrigation and drainage flows were 3,608mm and 1,170mm in 1999, and 3,971mm and 1,548mm in 2000, respectively. The mean and range of the daily infiltration rate were 4.4mm/d and 3.4mm/d to 5.5mm/d in 1999 and 5.1mm/d and 4.1mm/d to 6.5mm/d in 2000, respectively. The net ground water flow including the change of soil water storage was 2,855mm in 1999 and 2,540mm in 2000. The evapotranspiration was 458.3mm in 1999 and 553.5mm in 2000. The range of daily evapotranspiration rate was from 1.6 to 8.7mm/d. The return flow ratio was about 32% in 1999 and 39% in 2000 and three year average was 35% including previous study in 1997. The amount of irrigation water was much higher than design standards or references in this study, This was caused by the inadequate water management practice in the area where water was oversupplied on farmers’ request rather than following sound water management principles.

  • PDF

주거용 건물의 태양광 발전시스템 경제성 평가에 관한 연구 (A Study on the Economic Evaluation of Photovoltaic System in the Residential Building)

  • 최정민;주재욱;김동규
    • 한국태양에너지학회 논문집
    • /
    • 제29권6호
    • /
    • pp.14-21
    • /
    • 2009
  • The demand and installation for photovoltaic system(namely, PV) has grown steadily in Korea. However, the PV system has a various economic viability according to the PV system characteristic variables such as inverter efficiency, miscellaneous power conditioning losses, azimuth and slope of PV array, PV tracking mode, and so on. The other variables are the monthly consumed electric energy and economic related factor such as initial cost, government subsidy, maintenance cost, inflation rate, energy cost escalation rate, discount rate, etc. Therefore, this study is to present economic evaluation of PV system with those concerned factors by calculating internal rate of return, year-to-positive cash flow and net present value indices.