• Title/Summary/Keyword: Return Temperature

Search Result 255, Processing Time 0.033 seconds

30 GHz 세라믹 패키지의 제작 및 측정

  • 서재옥;김진양;박성대;이우성;강남기;이해영
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2002.11a
    • /
    • pp.147-151
    • /
    • 2002
  • We fabricated and characterized a millimeter-wave ceramic package in a frequency range from 6 to 40㎓ using the LTCC(Low Temperature Cofired Ceramic) Technology and TRL(Thru-Reflect-Line) calibration method. From these measurement results, the fabricated feed-through structure achieved 0.5 dB, 14 dB of the insertion loss and the return loss at 30 GHz respectively. This ceramic package will be useful for MMIC(Monolithic Microwave Integrated Circuit) modules.

  • PDF

Under Water Sonar Transducer Using Terfenol-D Magnetostrictive Material

  • Son, Derac;Cho, Yuk
    • Journal of Magnetics
    • /
    • v.4 no.3
    • /
    • pp.98-101
    • /
    • 1999
  • In this work we htave constructed an under water sonar transducer using Terfenol-D rod employing open magnetic circuit. Normally Sonar transducer using Terfenol-D was designed under closed magnetic flux return path, and permanent magnet for dc bias marnetic field, but high magnetic field should be applied to the transducer coil for high sound power and it brings temperature increase inside of the transducer. To improve this heat dissipation problem, we have designed an open magnetic circuit type transducer and we can get 200 dB (re. 1 Pa @ 1m) sound power for the input power of 650 VA.

  • PDF

Wind Load Assumption of 765Kv Transmission Towers

  • Kim, Jeong-Boo
    • Journal of Electrical Engineering and information Science
    • /
    • v.1 no.1
    • /
    • pp.45-50
    • /
    • 1996
  • This paper mainly describes the wind load assumption of 765kV transmission towers. We analyzed wind velocity data a meteorological observatories to get the wind velocity of 50 years return period by using Gumbel I type extreme value distribution. By multi-correlative regression analysis method, wind velocity at no observation site was obtained. Reference dynamics wind pressure map was obtained from above analysis and the wind pressure was classified as three regio in high temperature season.

  • PDF

A Study on the Distribution of Airflow and Temperature in a Data center under the Various Conditions of Heat Generation Rates of Server Computers (서버 컴퓨터의 발열량이 변화한 경우의 데이터센터 내의 기류 및 온도분포 특성에 대한 연구)

  • Chang, Hyun-Jae;Kim, Je-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.3
    • /
    • pp.108-114
    • /
    • 2014
  • On a large scale of data center, heat generation rates from sever computers occupy almost the entire cooling load of the building, and it is gradually increasing. The efficiency of air distribution system in data centers can be affected by heat generation rates of server computers. In this study, the distributions of airflow and temperature in a data center have been investigated by CFD simulations under various conditions of heat generation rates for server computers. From the results, air around the cold aisle which has high temperature flows tremendously into the cold aisle according to the increase of heat generation rates for server computers and the air temperature in the cold aisle becomes higher. The SHI (supply heat index) and RHI (return temperature index) show almost similar values to the cases study because the air inflow rates to server computers increase with the heat generation rates of server computers.

The Study on Efficiency Improvement of a Thermal Storage Tank for Solar Combined Heating System (태양열원 난방기의 수축열조 효율개선에 관한 연구)

  • Ryu, Nam-Jin;Han, Yu-Ry;Park, Youn-Cheol
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.43-49
    • /
    • 2007
  • This study is conducted to improve the efficiency of a thermal storage tank. The thermal storage tank was designed to store heat energy that obtained from the solar or the others heat sources. However, it has difficulties in storing heat with nonuniform temperature through the entire tank with respect to the vertical direction, This study is focused on the thermal stratification to improve thermal comfort for the resident in house. To enhance temperature stratification of the tank, a distributor was designed and installed in the middle of the storage tank vertically. The vertically designed distributor could supply the return water with stratified temperature in the storage tank with respect to the height. The water velocity from the distributor hole is the same with the other outlet in the distributor. However, gravity effect on the flow in the storage tank is much higher than that of the velocity effect due to that Froude Number is less than 1. During the heat charging process in the storage tank, temperature maintained with little difference with respect to the height. However the charging process takes long time to get a effective temperature for the heating or hot water supply because of all of water in the storage tank needs to be heated.

Thermal-hydraulic and load following performance analysis of a heat pipe cooled reactor

  • Guanghui Jiao;Genglei Xia;Jianjun Wang;Minjun Peng
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1698-1711
    • /
    • 2024
  • Heat pipe cooled reactors have gained attention as a potential solution for nuclear power generation in space and deep sea applications because of their simple design, scalability, safety and reliability. However, under complex operating conditions, a control strategy for variable load operation is necessary. This paper presents a two-dimensional transient characteristics analysis program for a heat pipe cooled reactor and proposes a variable load control strategy using the recuperator bypass (CSURB). The program was verified against previous studies, and steady-state and step-load operating conditions were calculated. For normal operating condition, the predicted temperature distribution with constant heat pipe temperature boundary conditions agrees well with the literature, with a maximum temperature difference of 0.4 K. With the implementation of the control strategy using the recuperator bypass (CSURB) proposed in this paper, it becomes feasible to achieve variable load operation and return the system to a steady state solely through the self-regulation of the reactor, without the need to operate the control drum. The average temperature difference of the fuel does not exceed 1 % at the four power levels of 70 %,80 %, 90 % and 100 % Full power. The output power of the turbine can match the load change process, and the temperature difference between the inlet and outlet of the turbine increases as the power decreases.

A study on Production of Al Foam by Using of Al Return Scrap for Sound and Vibration Absorption Materials

  • Hur, Bo-Young;Kim, Sang-Youl;Park, Dae-Chol;Jeon, Sung-Hwan;Park, Chan-Ho;Yoon, Ik-Sub
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.198-201
    • /
    • 2001
  • Porous structures of aluminum foam have been studied by using return aluminum scrap. The apparent foam shape, foam height, density, pore size and their distributions in various section areas of the experimental samples have been investigated. The sample have been cast into metallic mold, using aluminum foam prepared from a precursor based on pure Al ingot and return aluminum scrap mixed with various amounts of 1-2wt% increasing viscosity and foam agent materials. The process provides for flexibility in design of foam structures via relatively easy control over the amount of hydrogen evolution and the drainage processes which occur during foam formation. This is facilitated by manipulating parameters such as the foaming agent, thermal histories during solidification and mix melt viscosities. A metal for producing the foamed are decomposing a foaming agent in a molten metal such that there is an initial and a subsequent expansion due to foaming agent. It has been found that the Al porous foaming with variation amount of 1∼2wt% foam agent and at 2min holding time, which melting temperature has appeared homogeneous pore size at 650∼700$^{\circ}C$. The compression strength were 10-13 kg/min at 125ppi, and increased by higher pore density. The acoustical performance of the panel made with the foamed aluminum is considerably improved; its absorption coefficient shows NRC 0.6-0.8. It has been found that the Al foam is very preferable for the compactness of the thermal system.

  • PDF

Effect of Herbal Bath for Duration of Pediatric Fever : a Systematic Review and Meta-analysis (한약재 약욕요법이 소아 발열기간에 미치는 영향 : 체계적 문헌고찰 및 메타분석)

  • Kim, Ye Ji;Park, So Hyun;Seo, Hae Sun;Park, Sul Gi;Lee, Sun Haeng;Lee, Jin Yong
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.35 no.3
    • /
    • pp.53-66
    • /
    • 2021
  • Objective The purpose of this study is to evaluate whether herbal bath shortens the duration of pediatric fever. Methods Databases, such as Medline, EMBASE, Cochrane library, OASIS, KISS, KMBASE, CNKI, Wanfang Med Online were used to search randomized controlled trials. Those trials that included children younger than 18-year-old were evaluated for the clinical efficacy of herbal bath in fever by analyzing 'body temperature (BT) drop start time' and 'time to return to normal BT'. Results 12 studies or 1306 participants were analyzed in the study. When applying herbal bath in combination with the controlled treatment, 'BT drop start time' was decreased by 0.11 hours, and 'time to return to normal BT' was decreased by 10.94 hours compared to the controlled group. When comparing herbal bath with tepid bath, 'time to return to normal BT' was reduced by 8.19 hours in herbal bath group. In regards to safety, 3 studies out of 12 studies mentioned about its adverse events: 2 studies did not have any adverse events, and a minor needle-shaped bleeding had occurred in one of the studies. Conclusion Use of herbal bath as a treatment of fever in children was associated with shortened duration of fever. However, cautious interpretation is necessary due to its limited safety data.

Investigation of Pitting Corrosion of Copper Heat-Return Pipe in District Heating (지역난방 구리난방환수관의 공식 원인 분석)

  • Keun Hyung Lee;Min Ji Song;Tae Uk Kang;Woo Cheol Kim;Heesan Kim;Soo Yeol Lee
    • Corrosion Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.315-323
    • /
    • 2024
  • This work examined pitting corrosion failure of a copper heat-return pipe used in a district heating system. The copper pipe was corroded with a 48% reduction in thickness due to localized corrosion on the inner surface exposed to heating water of 20 ~ 40 ℃. Fe and Si elements as corrosion products were found around pits. Cl element was also observed, which accelerated oxidation of copper inside pits. Cu2O deposits on the pit's bottom surface decreased the pH inside the pit. X-ray diffraction analysis revealed hematite, cuprite, malachite and brochantite as corrosion products. Chemical analysis demonstrated that Fe and Si elements did not exist in the copper, supply water, or heating water, indicating that Fe and Si species might have entered into the pipe from the exterior. These results indicated that pits were initiated due to ion concentration gradient near Fe and Si species. Moreover, the interior of pits had lower pH due to Cl- concentration and Cu2O reactions, which accelerated the pit's growth and led to formation of pinholes. Additionally, we confirmed that the type of pitting corrosion was a complex combination of types I and II based on the HCO3-/SO42- ratio, pH, temperature, and corrosion products.

Designing Forward Markets for Electricity using Weather Derivatives (날씨파생상품을 이용한 전기선물시장 설계)

  • Yoo, Shiyong
    • Environmental and Resource Economics Review
    • /
    • v.15 no.2
    • /
    • pp.319-353
    • /
    • 2006
  • This paper shows how weather derivatives can be used to hedge against the price risk and volume risk of purchasing relatively large amounts of electricity. Our specific approach to designing new contracts for electricity is to focus on the return over a summer season rather than on the daily levels of demand and price. It is shown that correct market signals can be preserved in a contract and the associated financial risk can be offset by weather options. The advantage of combining a forward contract with a weather derivative is that the high prices on hot days or when the temperature is high reflect the underlying high cost of producing power when the load is high and that the combined contract with a weather derivative substantially reduces the volatility of the return.

  • PDF