• Title/Summary/Keyword: Retrofit scheme

Search Result 47, Processing Time 0.02 seconds

An Analytical & experimental study on the thermal performance of trickle solar collector with Sinuous Cross-section (파형 단면을 가진 유하식 집열기의 열적 성능에 대한 이론 및 실험 연구(I))

  • Lee Jong Ho;Chung Mo;Baek Nam Choon;Auh Chungmoo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.12 no.4
    • /
    • pp.240-251
    • /
    • 1983
  • The municipal government of Daejeon, Korea set up a plan to retrofit solar energy to the existing swimming pool. The pool was constructed in 1980, and meets the requirements of International standard. It will be used for the 1986 Asian Games and the 1988 Seoul Olymipics. The roof structure of the existing pool is to be modified to accomodate trickle solar collectors. In addition, various energy conserving ideas will be applied to the existing building structure. For the prevention of over heating of collectors on the roof, natural air convection scheme will be adopted within the collector system. Natural convection of passive type heating would be also adopted for the space heating of the pool when the system is idle. At present, the pool can be utilized only for two months a year without auxilairy heating. With oil heating, the energy cost would be too high for the normal operation. When this project completed in March 1984, it would be expected to be openable for seven months a year without a significan amount of auxiliary heating. In this project, two dimensional numerical analysis technic have been used to analyse the characterisitics of thermal performance of the swimming pool system. An experimental tat verification of the theoretical analysis have been also attempted.

  • PDF

Experimental assessment of post-earthquake retrofitted reinforced concrete frame partially infilled with fly-ash brick

  • Kumawat, Sanjay R.;Mondal, Goutam;Dash, Suresh R.
    • Earthquakes and Structures
    • /
    • v.22 no.2
    • /
    • pp.121-135
    • /
    • 2022
  • Many public buildings such as schools, hospitals, etc., where partial infill walls are present in reinforced concrete (RC) structures, have undergone undesirable damage/failure attributed to captive column effect during a moderate to severe earthquake shaking. Often, the situation gets worsened when these RC frames are non-ductile in nature, thus reducing the deformable capability of the frame. Also, in many parts of the Indian subcontinent, it is mandatory to use fly-ash bricks for construction so as to reduce the burden on the disposal of fly-ash produced at thermal power plants. In some scenario, when the non-ductile RC frame, partially infilled by fly-ash bricks, suffers major structural damage, the challenge remains on how to retrofit and restore it. Thus, in this study, two full-scale one-bay, one-story non-ductile RC frame models, namely, bare frame and RC partially infilled frame with fly-ash bricks in 50% of its opening area are considered. In the previous experiments, these models were subjected to slow-cyclic displacement-controlled loading to replicate damage due to a moderate earthquake. Now, in this study these damaged frames were retrofitted and an experimental investigation was performed on the retrofitted specimens to examine the effectiveness of the proposed retrofitting scheme. A hybrid retrofitting technique combining epoxy injection grouting with an innovative and easy-to-implement steel jacketing technique was proposed. This proposed retrofitting method has ensured proper confinement of damaged concrete. The retrofitted models were subjected to the same slow cyclic displacement-controlled loading which was used to damage the frames. The experimental study concluded that the hybrid retrofitting technique was quite effective in enhancing and regaining various seismic performance parameters such as, lateral strength and lateral stiffness of partially fly-ash brick infilled RC frame. Thus, the steel jacketing retrofitting scheme along with the epoxy injection grouting can be relied on for possible repair of the structural members which are damaged due to the captive column effect during the seismic shaking.

The optimum damping retrofit for cabinet structures of NPP by μ-GA (μ-GA를 이용한 원전 캐비닛구조물의 최적감쇠보강)

  • Lee, Gye-Hee;Ha, Dong-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.1 s.41
    • /
    • pp.1-7
    • /
    • 2005
  • The optimal seismic retrofitting of NPP(Nuclear Power Plant) cabinet structures that contain seismic category 1 relays was studied in this paper. During earthquake event, the failure modes of relays are not appeared in form of structural failure, but are appeared in form of contact chatter of relay. Therefore, the retrofitting of cabinet has to be aimed at the reducing of the structural response, such as acceleration. In this study, the optimal characteristic values of dampers were searched by ${\mu}$-GA (micro-Genetic Algorithm) scheme for several installation patterns. To keep accuracy and efficiency of analysis, the structural models of cabinet were considered as a frame structure. The responses of structure were obtained inform of acceleration response spectra derived from the results of nonlinear time history analysis including damping nonlinearity. The objective function of the optimum procedure was constructed based on the maximum ratio of maximum spectral value and target GERS (General Equipment Ruggedness Spectra). The results show the good improvements of fitness for adequate retrofitting pattern. Especially, the improvements of fitness were remarkable when the values of damping exponents are low.

Seismic Performance Evaluation of Inverted V Braced Steel Frames with Considering P-Δ Effects: A Case Study (P-Δ 효과를 고려한 역 V형 철골 가새골조의 내진성능평가: 사례연구)

  • Lee, Cheol-Ho;Kim, Jeong-Jae
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.3
    • /
    • pp.97-103
    • /
    • 2004
  • Most of the columns in centrally braced steel frame buildings are usually designed as the gravity columns to reduce connection cost. For a rational seismic performance evaluation of centrally braced steel frame buildings, it is important to properly incorporate in the analysis  the P-${\Delta}$ effects arising from the gravity columns. An effective scheme for the P-${\Delta}$ effects modeling due to the gravity columns was illustrated based on the concept of fictitious leaning column. Seismic performance evaluation of inverted V braced steel frames with or without P-${\Delta}$ effects modeling was conducted by following the FEMA 273 NSP (Nonlinear Static Procedure). The problem in estimating dynamic P-${\Delta}$ modification factor (C3) in FEMA 273 was discussed. The results of this study indicated that the P-${\Delta}$ effects should be included in the seismic performance evaluation of centrally braced steel frames. This study also showed that the inverted V braced frames, retrofitted by applying the tie bars to redistribute the inelastic demand over the height of the building, exhibit significantly improved seismic performance.

Control of wind-induced motion in high-rise buildings with hybrid TM/MR dampers

  • Aly, Aly Mousaad
    • Wind and Structures
    • /
    • v.21 no.5
    • /
    • pp.565-595
    • /
    • 2015
  • In recent years, high-rise buildings received a renewed interest as a means by which technical and economic advantages can be achieved, especially in areas of high population density. Taller and taller buildings are being built worldwide. These types of buildings present an asset and typically are built not to fail under wind loadings. The increase in a building's height results in increased flexibility, which can lead to significant vibrations, especially at top floors. Such oscillations can magnify the overall loads and can be annoying to the top floors' occupants. This paper shows that increased stiffness in high-rise buildings may not be a feasible solution and may not be used for the design for comfort and serviceability. High-rise buildings are unique, and a vibration control system for a certain building may not be suitable for another. Even for the same building, its behavior in the two lateral directions can be different. For this reason, the current study addresses the application of hybrid tuned mass and magneto-rheological (TM/MR) dampers that can work for such types of buildings. The proposed control scheme shows its effectiveness in reducing floors' accelerations for both comfort and serviceability concerns. Also, a dissipative analysis carried out shows that the MR dampers are working within the possible range of optimum performance. In addition, the design loads are dramatically reduced, creating more resilient and sustainable buildings. The purpose of this paper is to stimulate, shape, and communicate ideas for emerging control technologies that are essential for solving wind related problems in high-rise buildings, with the objective to build the more resilient and sustainable infrastructure and to optimally retrofit existing structures.

Weighting-Factored Evaluation Method for Determination of Seismic Retrofitting Schemes for Existing Bridges (기존 도로교의 내진성능향상 방법 선정을 위한 가중치 평가기법)

  • Ha, Dong-Ho;Lee, Ji-Hoon;Park, Kwang-Soon;Lee, Yong-Jae
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.3 s.55
    • /
    • pp.43-52
    • /
    • 2007
  • This study suggests a method to determine optimal seismic retrofitting schemes for existing bridges based on weighting-factored evaluation. According to the recognition for potential seismic risk, various kinds of retrofitting methods are applied to improve the seismic performance of existing bridges. However, the relevant technique is not available to select optimal retrofitting scheme for bridges now. This suggested method weights five factors, structural compatibility, economic efficacy, environmental factor, consturctability and maintenance, and draws out optimal seismic retrofitting schemes. The application of the developed method to one hundred sixty existing bridges verifies the adaptability of this method. As a result, this study provides an idealized retrofitting schemes, and the suggested method could be a guideline to determine the more cost-effective and optimal retrofitting schemes for existing bridges in Korea.

Development of an SDOF Model for Seismic Performance Evaluation of Low to Mid-Rise Reinforced Concrete Residential Buildings (중저층 철근콘크리트 주거형 건축물의 내진성능평가를 위한 단자유도 모델 구축)

  • Minseok Park;Seoyoun Lee;Insub Choi
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.37 no.5
    • /
    • pp.301-308
    • /
    • 2024
  • During earthquakes, buildings can suffer damage ranging from minor to severe, potentially leading to collapses and resulting in loss of life and property. To mitigate these risks, it is essential to evaluate the seismic performance of buildings. Current seismic performance evaluation techniques require significant time as they focus on individual buildings. Therefore, there is a need to develop evaluation techniques that can be applied on a regional scale. This study proposes a single-degree-of-freedom model with a nonlinear shear spring to assess the seismic performance and plan the reinforcement of reinforced concrete residential buildings. The nonlinear shear spring, defined by the T-SR-μ parameter, is used to simulate the nonlinear response of the structure. By applying 100-PEER ground motions to this model, the seismic performance of the buildings was evaluated based on the maximum inter-story drift ratio response. The applicability of the proposed technique was confirmed by comparing it with detailed models, where both models assessed the seismic performance of the buildings at similar levels. This results demonstrate that the proposed method can accurately predict the seismic performance of actual buildings.