  • The domestic seismic retrofit guide was primally enacted in 1988, then the mandatory target have been consistently. As a result, the rate of earthquake-resistant is achieved 58.3% in public facilities. On the other hand, the rate of earthquake-resistant is low as 24.8% in education facilities. As education facilities damaged from Gyeong-ju, Po-hang earthquake occurred in South-Korea and the rate of earthquake-resistant is low, the seismic retrofit of existing education facilities got to be ordinary people's interest. Therefore, domestic researchers have been developed seismic retrofit methods which can apply to existing educational facilities, It is expected to become more active in the future. However, it is insufficient to consideration that how far domestic technology has been developed. Therefore, the objective of this study is to measure the level of domestic research through comparative analysis between domestic and foreign researches that seismic retrofit methods which can apply to existing educational facilities.

  • PDF

철근콘크리트 골조와 강재댐퍼의 강성비 및 내력비에 따른 내진보강 성능 (Performance of Seismic Retrofit According to the Stiffness and Strength Ratios of Steel Damper to Reinforced Concrete Frame)

  • 백은림;오상훈;이상호
    • 한국지진공학회논문집
    • /
    • 제17권4호
    • /
    • pp.171-180
    • /
    • 2013
  • The purpose of this study is to evaluate the effectiveness of the seismic retrofit performance for a reinforced concrete structure with steel damper. The nonlinear static analysis of the RC frame specimens with and without retrofit using the steel damper was conducted and the reliability of the analysis was verified by comparing the analysis and test results. Using this analysis model and method, additional nonlinear analysis was conducted considering varying stiffness and strength ratios between RC frame and steel damper and the failure mode of RC frame. As the result of the study, the total absorbed energy increased and the damage of RC frame was reduced as stiffness and strength ratios increased. The seismic retrofit performance, evaluated by means of the yield strength, increasing ratio of the absorbed energy and damage of the frame, increased linear proportionally with the increase of the strength ratio. In addition, the seismic retrofit performance was stable for stiffness ratios larger than 4~5. The energy absorption capacity of the frame governed by shear failure was better than that of the frame governed by flexure failure.

Optimal seismic retrofit design method for asymmetric soft first-story structures

  • Dereje, Assefa Jonathan;Kim, Jinkoo
    • Structural Engineering and Mechanics
    • /
    • 제81권6호
    • /
    • pp.677-689
    • /
    • 2022
  • Generally, the goal of seismic retrofit design of an existing structure using energy dissipation devices is to determine the optimum design parameters of a retrofit device to satisfy a specified limit state with minimum cost. However, the presence of multiple parameters to be optimized and the computational complexity of performing non-linear analysis make it difficult to find the optimal design parameters in the realistic 3D structure. In this study, genetic algorithm-based optimal seismic retrofit methods for determining the required number, yield strength, and location of steel slit dampers are proposed to retrofit an asymmetric soft first-story structure. These methods use a multi-objective and single-objective evolutionary algorithms, each of which varies in computational complexity and incorporates nonlinear time-history analysis to determine seismic performance. Pareto-optimal solutions of the multi-objective optimization are found using a non-dominated sorting genetic algorithm (NSGA-II). It is demonstrated that the developed multi-objective optimization methods can determine the optimum number, yield strength, and location of dampers that satisfy the given limit state of a three-dimensional asymmetric soft first-story structure. It is also shown that the single-objective distribution method based on minimizing plan-wise stiffness eccentricity turns out to produce similar number of dampers in optimum locations without time consuming nonlinear dynamic analysis.

Cost and reliability of retrofit alternatives for schools located on seismic zones

  • De Leon-Escobedo, David;Garcia-Manjarrez, Jose Luis
    • Earthquakes and Structures
    • /
    • 제21권5호
    • /
    • pp.505-514
    • /
    • 2021
  • A formulation based on structural reliability and cost effectiveness is proposed to provide recommendations to select the best retrofit strategy for schools with reinforced concrete frames and masonry walls, among three proposed alternatives. The cost calculation includes the retrofit cost and the expected costs of failure consequences. Also, the uncertainty of the seismic hazard is considered for each school site. The formulation identifies the potential failure modes, among shear and bending forces for beams, and flexure-compression forces for columns, for each school, and the seismic damages suffered by the schools after the earthquake of September 17, 2017 are taken into account to calibrate the damaged conditions per school. The school safety level is measured through its global failure probability, instead of only the local failure probability. The proposed retrofit alternatives are appraised in terms of the cost/benefit balance under future earthquakes, for the respective site seismic hazard, as opposed to the current practice of just restoring the structure original resistance. The best retrofit is the one that corresponds to the minimum value of the expected life cycle cost. The study, with further developments, may be used to develop general recommendations to retrofit schools located at seismic zones.

Seismic performance evaluation of an external steel frame retrofit system

  • Michael Adane;Hyungoo Kang;Seungho Chun;Jinkoo Kim
    • Steel and Composite Structures
    • /
    • 제50권5호
    • /
    • pp.549-562
    • /
    • 2024
  • In this study a steel moment frame system to be installed on the exterior surface of an existing structure is proposed as a seismic retrofit device. The seismic performance of the retrofit system was investigated by installing it on the exterior of a single story single bay reinforced concrete frame and testing it under cyclic loading. The cyclic loading test results indicated that the steel frame significantly enhanced the strength and ductility of the bare structure. Finite element analysis was carried out to validate the test results, and it was observed that there was good agreement between the two results. An analytical model was developed in order to apply the retrofit system to an example structure subjected to seven mainshock-aftershock sequential earthquake records. It was observed that the model structure was severely damaged due to the mainshock earthquakes, and the seismic response of the model structure increased significantly due to the subsequent aftershock earthquakes. The seismic retrofit of the model structure using the proposed steel frame turned out to be effective in decreasing the seismic response below the given limit state.

External retrofit of beam-column joints in old fashioned RC structures

  • Adibi, Mahdi;Marefat, Mohammad S.;Arani, Kamyar Karbasi;Zare, Hamid
    • Earthquakes and Structures
    • /
    • 제12권2호
    • /
    • pp.237-250
    • /
    • 2017
  • There has been increasing attention in many countries on seismic retrofit of old fashioned RC structures in recent years. In such buildings, the joints lack transverse reinforcement and suffer inadequate seismic dimensional requirements and the reinforcement is plain bar. The behavior of the joints is governed by sliding of steel bars and diagonal shear failure is less influential. Different methods to retrofit beam-column joints have been proposed in the literature such as wrapping the joint by FRP sheets, enlargement of the beam-column joint, and strengthening the joint by steel sheets. In this study, an enlargement technique that uses external prestressed cross ties with steel angles is examined. The technique has already been used for substructures reinforced by deformed bars and has advantages such as efficient enhancement of seismic capacity and lack of damage to the joint. Three reference specimens and two retrofitted units are tested under increasing lateral cyclic load in combination with two levels of axial load. The reference specimens showed relatively low shear strength of 0.150${\surd}$($f_c$) and 0.30${\surd}$($f_c$) for the exterior and interior joints, respectively. In addition, relatively brittle behavior was observed and large deformations extended into the panel zone of the joints. The retrofit method has increased ductility ratio of the interior beam-column joints by 63%, and energy dissipation capacity by 77%, relative to the control specimen; For external joints, these values were 11%, and 94%. The retrofit method has successfully relocated the plastic joints far from the column face. The retrofit method has improved shear strength of the joints by less than 10%.

보강기법에 따른 개구부가 있는 전단벽의 보강효과 규명 (Retrofit Performance of Artificially Perforated Shearwall by Retrofit Method)

  • 최현기;이진아;최윤철;최창식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.29-32
    • /
    • 2008
  • 리모델링은 친환경적 접근 방법으로써 현재 수요가 증가하고 있는 추세이다. 리모델링 사업시 구조 부재를 동반한다. 그러므로 리모델링시에 구조적인 안정성을 확보하기 위해서는 적절한 보강 방법이 요구된다. 이 연구의 목적은 전단벽에 개구부가 발생하였을 경우 Passive 보강 방식과 Active 보강 방식을 이용하였을 때의 거동 특성을 파악하는 것이다. Passive 보강 방식은 CFS나 강판 등을 부착하여 손상 부재를 보강하는 방식이고, Active 보강 방식은 프리스트레싱을 이용한 균열 제어를 통해 보강력을 도입하는 방식이다. 실험 결과 각 실험체들은 전단 파괴 형태를 보여주었고 두 가지의 다른 보강 방식은 강도나 연성에 있어서 다른 결과를 보여주었다.

  • PDF

Force-based seismic design of steel haunch retrofit for RC frames

  • Ahmad, Naveed
    • Earthquakes and Structures
    • /
    • 제20권2호
    • /
    • pp.133-148
    • /
    • 2021
  • The paper presents a simplified force-based seismic design procedure for the preliminary design of steel haunch retrofitting for the seismic upgrade of deficient RC frames. The procedure involved constructing a site-specific seismic design spectrum for the site, which is transformed into seismic base shear coefficient demand, using an applicable response modification factor, that defines base shear force for seismic analysis of the structure. Recent experimental campaign; involving shake table testing of ten (10), and quasi-static cyclic testing of two (02), 1:3 reduced scale RC frame models, carried out for the seismic performance assessment of both deficient and retrofitted structures has provided the basis to calculate retrofit-specific response modification factor Rretrofitted. The haunch retrofitting technique enhanced the structural stiffness, strength, and ductility, hence, increased the structural response modification factor, which is mainly dependent on the applied retrofit scheme. An additional retrofit effectiveness factor (ΩR) is proposed for the deficient structure's response modification factor Rdeficient, representing the retrofit effectiveness (ΩR=Rretrofitted /Rdeficient), to calculate components' moment and shear demands for the retrofitted structure. The experimental campaign revealed that regardless of the deficient structures' characteristics, the ΩR factor remains fairly the unchanged, which is encouraging to generalize the design procedure. Haunch configuration is finalized that avoid brittle hinging of beam-column joints and ensure ductile beam yielding. Example case study for the seismic retrofit designs of RC frames are presented, which were validated through equivalent lateral load analysis using elastic model and response history analysis of finite-element based inelastic model, showing reasonable performance of the proposed design procedure. The proposed design has the advantage to provide a seismic zone-specific design solution, and also, to suggest if any additional measure is required to enhance the strength/deformability of beams and columns.

폭발하중을 받는 콘크리트 벽체 구조물의 보강 성능에 대한 해석적 분석 (Analytical Evaluations of the Retrofit Performances of Concrete Wall Structures Subjected to Blast Load)

  • 김호진;남진원;김성배;김장호;변근주
    • 콘크리트학회논문집
    • /
    • 제19권2호
    • /
    • pp.241-250
    • /
    • 2007
  • 폭발하중을 받는 콘크리트 구조물을 섬유 복합재 등의 보강 재료를 사용하여 보강하는 경우에는 강성 증가와 함께 적절한 연성을 확보할 수 있어야 한다. 그러나, 폭발하중을 받는 구조물의 설계 및 해석에 일반적으로 사용되는 기존의 근사적이며 단순화 모델은 보강 재료에 대한 효과를 정확히 반영할 수 없을 뿐 아니라 해석 결과의 정확성 및 신뢰성에 문제가 제기되어왔다. 또한, 동적 하중에 대한 콘크리트와 철근의 응답은 정적 하중에 대한 응답과 상이하기 때문에 기존의 정적, 준정적하에서 정의된 재료물성값들을 폭발하중에 대한 응답 계산에 사용하는 것은 부적절하다. 따라서, 본 연구에서는 명시적(explicit) 해석 프로그램인 LS-DYNA를 사용하여 매우 빠른 재하속도를 갖는 폭발하중에 대하여 강도 증진 및 변형률 속도 효과가 반영된 재료 모델을 포함하고 있는 정밀 HFPB(high fidelity physics based) 유한요소해석 기법을 제시하였다. 제시된 해석적 기법을 통하여 탄소섬유 복합재와 유리섬유 복합재를 사용하여 보강된 콘크리트 벽체의 폭발하중에 대한 거동을 해석하였으며, 이를 보강하지 않은 벽체의 해석 결과와 비교함으로써 보강 성능 분석을 실시하였다. 해석 결과 보강에 따른 최대 처짐이 약 $26{\sim}28%$ 감소하는 보강 성능을 확인하였으며, 제안된 해석 기법이 보강 재료와 보강 기법의 유효성을 평가하는데 효과적으로 적용할 수 있을 것으로 판단된다.

Study on the bearing capacity of cold-formed steel under different boundary conditions in transmission towers

  • Han, Junke;Zhao, Xu;Tang, Zhenyun;Ma, Hua;Li, Zhenbao
    • Earthquakes and Structures
    • /
    • 제12권6호
    • /
    • pp.665-672
    • /
    • 2017
  • Cold-formed steel is widely used in steel structures, especially in transmission towers, because of advantages such as low weight, high strength, excellent mechanical properties, etc. However, there is not a special design code for cold-formed steel use in transmission towers in China. For this study, a total of 105 compression members were tested statically to investigate the bearing capacity of cold-formed steel members under different boundary conditions in transmission towers. The test results were compared to the results predicted by the current design codes. For deeper insight, additional coupled members were simulated using finite element analysis. An improved design method was developed based on the experimental and analytical results.