• Title/Summary/Keyword: Retaining Structure

Search Result 306, Processing Time 0.026 seconds

A load-bearing structural element with energy dissipation capability under harmonic excitation

  • Pontecorvo, Michael E.;Barbarino, Silvestro;Gandhi, Farhan S.;Bland, Scott;Snyder, Robert;Kudva, Jay;White, Edward V.
    • Advances in aircraft and spacecraft science
    • /
    • v.2 no.3
    • /
    • pp.345-365
    • /
    • 2015
  • This paper focuses on the design, fabrication, testing and analysis of a novel load-bearing element with energy dissipation capability. A single element comprises two von-Mises trusses (VMTs), which are sandwiched between two plates and connected to dashpots that stroke as the VMTs cycle between stable equilibrium states. The elements can be assembled in-plane to form a large plate-like structure or stacked with different properties in each layer for improved load-adaptability. Also introduced in the elements are pre-loaded springs (PLSs) that provide high initial stiffness and allow the element to carry a static load even when the VMTs cannot under harmonic disturbance input. Simulations of the system behavior using the Simscape environment show good overall correlation with test data. Good energy dissipation capability is observed over a frequency range from 0.1 Hz to 2 Hz. The test and simulation results show that a two layer prototype, having one soft VMT layer and one stiff VMT layer, can provide good energy dissipation over a decade of variation in harmonic load amplitude, while retaining the ability to carry static load due to the PLSs. The paper discusses how system design parameter changes affect the static load capability and the hysteresis behavior.

A Study on the Efficient Management of Space and Facilities in National Universities (국립대학 시설 및 공간의 효율적 관리에 관한 연구)

  • Lee, Hwa-Ryong;Cho, Chang-Hee
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.15 no.5
    • /
    • pp.21-32
    • /
    • 2008
  • The major issues that higher education has recently faced are the shortage of students of school age, the changing environment of higher education and the evolving technology. These challenges have urged the university facilities and space to be managing more efficient and more effective. This study assures that the strong strategy is to operate more like business while retaining unique higher education values and a sound facilities management system and appropriate budget help to ensure that university facilities are good for student and teacher's demand. With such faith, this study explores the facilities/space maintaining status and the facility management system of national universities and collages. It finds that there are some problems to adapt new managing methodologies in national universities and that there are also some gaps and perceived constraints to effective space management. This study proposes the alternatives for the facilities managing system that involves the improvement of manpower structure, the expansion of budget scale and the establishment of appropriate facility management system. Finally it provides the practical tools for the effective space and facilities management such as space charging, space standards, central timetabling, space utilisation survey and facilities performance indication.

Analysis of Loading Rate Capacity of Plate Anchor in Sand (사질토 지반에 설치된 판앵커의 인발속도에 따른 저항력 분석)

  • Ryu, Dong-Man;Seo, Young-Kyo
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.5
    • /
    • pp.31-39
    • /
    • 2012
  • Anchors are primarily designed and constructed to resist outwardly directed loads imposed on the foundation of a structure. These outwardly directed loads are transmitted to the soil at a greater depth by the anchors. Buried anchors have been used for thousands of years to stabilize structures. Nowadays, various types of earth anchors are used for the uplift resistance of transmission towers, utility poles, submerged pipelines, and tunnels. Anchors are also used for the tieback resistance of earth-retaining structures, waterfront structures, at bends in pressure pipelines, and when it is necessary to control thermal stress. In this research we analyzed the uplift behavior of plate anchors in sand using a laboratory experiment to estimate the uplift behavior of plate anchors under various conditions. To achieve the research purpose, the uplift resistance and displacement characteristics of plate anchors caused by the embedment ratio, plate diameter, and loading rate were studied, compared, and analyzed in various cases.

Weatherability Assessment of Nonwoven Geotextiles by Field Exposure Test (현장노출시험에 의한 부직포 지오텍스타일의 내후성 평가)

  • Jeon, Han-Yong;Yuu, Jung Jo;Kim, Young Yoon;Byun, Sung Weon;Byun, Sung Weon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.3 no.1
    • /
    • pp.37-42
    • /
    • 2004
  • In the reinforced retaining wall system, non-woven geotextiles are placed at the face of reinforced earth until the facing blocks are built up. And when this system is used as temporary structure, geotextiles facings are exposed to sunlight during service lifetime. During these periods, degradation of nonwoven geotextiles are occurred by UV light. So the UV-resistance of nonwoven geotextiles must be assessed correctly, in considering of the site conditions. In this study, laboratory test and the field test have been performed to evaluate the UV resistance of non-woven geotextiles used in KOESWall system and the results are expressed in terms of tensile characteristics & SEM photographs.

  • PDF

A Study on Behavior of the Earth Retaining Structure by Field Measurement and Numerical Analysis (현장계측과 수치해석에 의한 흙막이구조물의 거동 비교분석)

  • Wo, Jongtae
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.3
    • /
    • pp.286-295
    • /
    • 2017
  • In this study, it is compared various coefficients of subgrade reaction for application of numerical analysis based on measured data by using various theories and empirical formula. The ratio of the maximum and minimum value is 6.80 at the top of wall but it is 1.06 at the maximum displacement point depends on change of calculated coefficient of subgrade reaction. The data of displacement were generally similar considering an increment of a coefficient of subgrade reaction. And the results of comparison of the displacement at the maximum displacement point by numerical analysis and measured data show similar displacement shape.

Microstructural observations of shear zones at cohesive soil-steel interfaces under large shear displacements

  • Mamen, Belgacem;Hammoud, Farid
    • Geomechanics and Engineering
    • /
    • v.25 no.4
    • /
    • pp.275-282
    • /
    • 2021
  • Failure mechanism which can affect geotechnical infrastructures (shallow foundations, retaining walls, and piles) constitutes one of the most encountered problems during the design process. In this respect, the shear behavior of interfaces between grained soils and solid building materials, as well as those between cohesive soils should be investigated. Therefore, a range of ring shear tests with different cohesive soils and stainless-steel interfaces have been carried out through the Bromhead apparatus that allows simulating large displacements along a failure surface. The effects of steel rings roughness and soil type on the residual friction coefficient and the shear zone features (structure, thickness, and texture orientation angle) have been investigated using the Scanning Electron Microscopy. The obtained results indicate that the residual friction coefficient and the structural characteristics of the shear zone vary according to the surface roughness and the soil type. Scanning electron microscopy reveals that the particles inside the shear zone tend to be re-oriented. Also, the shear failure mechanism can be identified along with the interface, within the soil, or simultaneously at the interface and within the soil specimen.

A Study on Imposing Exact Solutions as Internal Boundary Conditions in Simulating Shallow-water Flows over a Step (계단을 지나는 천수 흐름의 모의에서 내부 경계조건으로서 정확해의 부여에 관한 연구)

  • Hwang, Seung-Yong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.479-492
    • /
    • 2014
  • In this study, was proposed a numerical scheme imposing exact solutions as the internal boundary conditions for the shallow-water flows over a discontinuous transverse structure such as a step. The HLLL approximate Riemann solver with the MUSCL was used for the test of the proposed scheme. Very good agreement was obtained between simulations and exact solutions for various problems of the shallow-water flows over a step. In addition, results by the numerical model showed good agreement with those of dam-break experiments over a step and stepped chute one. Developed model can simulate the shallow-water flows over discontinuous bottom such as a drop structure without additional rating curve or topography smoothing. Given the proper evaluations for the flow resistance by a step and the energy loss by the nappe flow in the future, could be simulated flooding and drying of the shallow-water flows over discontinuous topography such as a weir or the river road with retaining wall.

Source Localization Based on Independent Doublet Array (독립적인 센서쌍 배열에 기반한 음원 위치추정 기법)

  • Choi, Young Doo;Lee, Ho Jin;Yoon, Kyung Sik;Lee, Kyun Kyung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.10
    • /
    • pp.164-170
    • /
    • 2014
  • A single near-field sounde source bearing and ranging method based on a independent doublet array is proposed. In the common case of bearing estimation method, unform linear array or uniform circular array are used. It is constrained retaining aperture because of array structure to estimate the distance of the sound source. Recent using independent doublet array sound source's bearing and distance esmtimation method is proposed by wide aperture. It is limited to the case doublets are located on a straight line. In this paper, we generalize the case and estimate the localization of a sound source in the various array structure. The proposed algorithm was verified performance through simulation.

An Experimental Study on Compressive Loading Capacity of Precast Concrete Truss System (프리캐스트 콘크리트 트러스 시스템의 압축 내하력 실험 연구)

  • Han, Man-Yop;Jeon, Se-Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.889-900
    • /
    • 2013
  • In a large scale of excavation for the foundation of large-sized structures and underground structures, a considerable amount of earth pressure can occur. Steel beams that have been used to form a temporary structure to support earth pressure may be less economical and less efficient in resisting the high earth pressure. To cope with this problem, PCT(Precast Concrete Truss) system has been devised and investigated both experimentally and analytically. A proper connection method between the concrete truss members was proposed to accommodate fast assembly and disassembly. Full-scale test of PCT system was performed to verify the load-carrying capacity of the PCT system including the connections. The test results were compared with those of structural analysis. The test specimen which corresponds to PCT strut attained the ultimate load without buckling, but the detail of connector members needs to be improved. It is expected that precast concrete truss members can be efficiently incorporated into a temporary structure for deep and large excavation by replacing conventional steel beams.

Crack Detection of Concrete Structure Using Deep Learning and Image Processing Method in Geotechnical Engineering (딥러닝과 영상처리기법을 이용한 콘크리트 지반 구조물 균열 탐지)

  • Kim, Ah-Ram;Kim, Donghyeon;Byun, Yo-Seph;Lee, Seong-Won
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.12
    • /
    • pp.145-154
    • /
    • 2018
  • The damage investigation and inspection methods performed in concrete facilities such as bridges, tunnels, retaining walls and so on, are usually visually examined by the inspector using the surveying tool in the field. These methods highly depend on the subjectivity of the inspector, which may reduce the objectivity and reliability of the record. Therefore, the new image processing techniques are necessary in order to automatically detect the cracks and objectively analyze the characteristics of cracks. In this study, deep learning and image processing technique were developed to detect cracks and analyze characteristics in images for concrete facilities. Two-stage image processing pipeline was proposed to obtain crack segmentation and its characteristics. The performance of the method was tested using various crack images with a label and the results showed over 90% of accuracy on crack classification and segmentation. Finally, the crack characteristics (length and thickness) of the crack image pictured from the field were analyzed, and the performance of the developed technique was verified by comparing the actual measured values and errors.