• Title/Summary/Keyword: Retainer

Search Result 137, Processing Time 0.028 seconds

A Research of medical bureaucrat was invested by Wonjong(原從) meritorious retainer (의관(醫官)의 원종공신(原從功臣) 녹훈(錄勳) 연구)

  • Park, Hun-Pyeng
    • The Journal of Korean Medical History
    • /
    • v.27 no.2
    • /
    • pp.85-98
    • /
    • 2014
  • The medical bureaucrats was awarded by Wonjong (原從) meritorious retainer were 376 peoples in the Joseon Dynasty. It was not done research on this is accurate so far. Why did they get Wonjong (原從) meritorious retainer? I have found a general rule of the investiture through review of the nokhundogamuigwe (錄勳都監儀軌). The Sillok(實錄) and other materials were used as an adjunct in the investigation. Through the analysis of this medical bureaucrats, This study aims to investigate the change in the social status of the Joseon Dynasty's medical officials. The conclusion of this paper is as follows. First, the social status of medical bureaucrat was similar to that of yangban (兩班) in early days of Joseon Dynasty compared with mid or late days of Joseon Dynasty. Second, bastard households are concentrated in the second half of the 16th century to the early 17th century to advance to the medical officials. Third, acupuncture doctors increased social status by the mid-Joseon Dynasty. Fourth, statutes about Wonjong (原從) meritorious retainer was raising the social status of medical bureaucrat compared to other technical officials.

A Study on Structural Analysis of High-Pressure Pipeline Retainer-Type Ball Valve by Pressure Testing of the Industrial Standard (산업용 표준의 압력시험 방법에 의한 고압 배관용 리테이너형 볼밸브의 구조해석에 관한 연구)

  • Kim, Chul Kyu;Yoon, Joon Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.5
    • /
    • pp.13-18
    • /
    • 2015
  • This study has been performed to evaluate the safety of the retainer-type ball valve for a high-pressure pipeline to a district heating plant. The retainer-type ball valve is an improved design for conventional ball valves, such as the floating ball valve and the trunnion ball valve. Numerical analysis of the valve design verification has been applied to investigate the safety factor and seat leakage of the DN300 and DN400 sizes. The given condition to solve the structural analysis was based on the international standard for ISO 5208. In this study, the methods for structural analysis are described in detail. The structural analysis results present the deformations, the equivalent stresses, and the safety factors. Through these results, this study successfully demonstrates the safety and seat leakage of the retainer-type ball valve. They also streamline the process of development for valve manufacturing.

A new type of clear orthodontic retainer incorporating multi-layer hybrid materials

  • Ahn, Hyo-Won;Kim, Kyung A;Kim, Seong-Hun
    • The korean journal of orthodontics
    • /
    • v.45 no.5
    • /
    • pp.268-272
    • /
    • 2015
  • Clear thermoplastic retainers have been widely used in daily orthodontics; however, they have inherent limitations associated with thermoplastic polymer materials such as dimensional instability, low strength, and poor wear resistance. To solve these problems, we developed a new type of clear orthodontic retainer that incorporates multi-layer hybrid materials. It consists of three layers; an outer polyethylenterephthalate glycol modified (PETG) hard-type polymer, a middle thermoplastic polyurethane (TPU) soft-type polymer, and an inner reinforced resin core. The resin core improves wear resistance and mechanical strength, which prevent unwanted distortion of the bucco-palatal wall of the retainer. The TPU layer absorbs impact and the PETG layer has good formability, optical qualities, fatigue resistance, and dimensional stability, which contributes to increased support from the mandibular dentition, and helps maintain the archform. This new type of vacuum-formed retainer showed improved mechanical strength and rate of water absorption.

A Study on the Improvement of Forming Processes of Valve-Spring Retainer (Valve-Spring Retainer의 성형공정개선에 관한 연구)

  • 오현석;황병복;이호용
    • Transactions of Materials Processing
    • /
    • v.5 no.2
    • /
    • pp.145-155
    • /
    • 1996
  • The conventional five-stage forming processes of the valve-spring retainer are simulated using the rigid-plstiv finite element method. As a design criterion the improved process should satisfy the maximum forging load during processes within the loading limit of the available press and should not induce any geometrical defects. hollow bars are recommended as initial billets to skip the heading and piercing processes. Through various simulations it is found out that the one stage process results in less forging loads and better strain distributions.

  • PDF

Effect of Preoperative Nasal Retainer on Nasal Growth in Patients with Bilateral Incomplete Cleft Lip: A 3-Year Follow-Up Study

  • Kim, Young Chul;Jeong, Woo Shik;Oh, Tae Suk;Choi, Jong Woo;Koh, Kyung S.
    • Archives of Plastic Surgery
    • /
    • v.44 no.5
    • /
    • pp.400-406
    • /
    • 2017
  • Background The purpose of this study was to evaluate changes in nasal growth after the implementation of a preoperative nasal retainer in patients with bilateral incomplete cleft lip. Methods Twenty-six infants with bilateral incomplete cleft lip and cleft palate were included in the study. A preoperative nasal retainer was applied in 5 patients from the time of birth to 2.6-3.5 months before primary cheiloplasty. Twenty-one patients who were treated without a preoperative nasal retainer were placed in the control group. Standard frontal, basal, and lateral view photographs were taken 3 weeks before cheiloplasty, immediately after cheiloplasty, and at the 1- and 3-year postoperative follow-up visits. The columella and nasal growth ratio and nasolabial angle were indirectly measured using photographic anthropometry. Results The ratio of columella length to nasal tip protrusion significantly increased after the implementation of a preoperative nasal retainer compared to the control group for up to 3 years postoperatively (P<0.01 for all time points). The ratios of nasal width to facial width, nasal width to intercanthal distance, columellar width to nasal width, and the nasolabial angle, for the two groups were not significantly different at any time point. Conclusions Implementation of a preoperative nasal retainer provided significant advantages for achieving columellar elongation for up to 3 years postoperatively. It is a simple, reasonable option for correcting nostril shape, preventing deformities, and guiding development of facial structures.

Effects of a new type of clear overlay retainer on occlusal contacts

  • Kim, Kyoung Yeon;Ahn, Hyo-Won;Kim, Seong-Hun;Nelson, Gerald
    • The korean journal of orthodontics
    • /
    • v.47 no.3
    • /
    • pp.207-212
    • /
    • 2017
  • The popularity of clear overlay retainers (CORs) has increased recently because of their advantages such as better esthetics, cost effectiveness, easy fabrication, and good compliance. However, a deficiency in posterior occlusal settling is a reported limitation of CORs. The aim of this study was to evaluate the posterior occlusal contact changes in a new type of clear orthodontic retainer called Oral-treaper (OTP), which consists of three layers and has stronger mechanical characteristics than do conventional retainers. Three patients who completed fixed orthodontic treatment received OTP as a removable retainer. Cast models were fabricated after the removal of fixed appliances (T1) and after 4 to 11 months of using the retainers (T2). We evaluated all the cast models to compare the post-orthodontic settling pattern during the use of the OTPs. The depth of occlusal contacts was evaluated using color maps. The OTP did not prevent vertical settling in all patients but resulted in an improvement in posterior occlusal contact points.

Two-year survival analysis of twisted wire fixed retainer versus spiral wire and fiber-reinforced composite retainers: a preliminary explorative single-blind randomized clinical trial

  • Sobouti, Farhad;Rakhshan, Vahid;Saravi, Mahdi Gholamrezaei;Zamanian, Ali;Shariati, Mahsa
    • The korean journal of orthodontics
    • /
    • v.46 no.2
    • /
    • pp.104-110
    • /
    • 2016
  • Objective: Traditional retainers (both metal and fiber-reinforced composite [FRC]) have limitations, and a retainer made from more flexible ligature wires might be advantageous. We aimed to compare an experimental design with two traditional retainers. Methods: In this prospective preliminary clinical trial, 150 post-treatment patients were enrolled and randomly divided into three groups of 50 patients each to receive mandibular canine-to-canine retainers made of FRC, flexible spiral wire (FSW), and twisted wire (TW). The patients were monitored monthly. The time at which the first signs of breakage/debonding were detected was recorded. The success rates of the retainers were compared using chi-squared, Kaplan-Meier, and Cox proportional-hazard regression analyses (${\alpha}=0.05$). Results: In total, 42 patients in the FRC group, 41 in the FSW group, and 45 in the TW group completed the study. The 2-year failure rates were 35.7% in the FRC group, 26.8% in the FSW group, and 17.8% in the TW group. These rates differed insignificantly (chi-squared p = 0.167). According to the Kaplan-Meier analysis, failure occurred at 19.95 months in the FRC group, 21.37 months in the FSW group, and 22.36 months in the TW group. The differences between the survival rates in the three groups were not significant (Cox regression p = 0.146). Conclusions: Although the failure rate of the experimental retainer was two times lower than that of the FRC retainer, the difference was not statistically significant. The experimental TW retainer was successful, and larger studies are warranted to verify these results.

Innovative customized CAD/CAM nickel-titanium lingual retainer versus standard stainless-steel lingual retainer: A randomized controlled trial

  • Gelin, Emilie;Seidel, Laurence;Bruwier, Annick;Albert, Adelin;Charavet, Carole
    • The korean journal of orthodontics
    • /
    • v.50 no.6
    • /
    • pp.373-382
    • /
    • 2020
  • Objective: To compare computer-aided design and computer-aided manufacturing (CAD/CAM) customized nitinol retainers with standard stainless-steel fixed retainers over a 12-month study period. Methods: This randomized controlled trial (RCT) was conducted on 62 patients randomly allocated to a control group that received stainless-steel retainers or a test group that received customized CAD/CAM nickel-titanium retainers. Four time points were defined: retainer placement (T0) and 1-month (T1), 6-month (T2), and 12-month (T3) follow-up appointments. At each time point, Little's irregularity index (LII) (primary endpoint) and dental stability measurements such as intercanine width were recorded in addition to assessment of periodontal parameters. Radiological measurements such as the incisor mandibular plane angle (IMPA) were recorded at T0 and T3. Failure events (wire integrity or debonding) were assessed at each time point. Results: From T0 to T3, LII and other dental measurements showed no significant differences between the two groups. The data for periodontal parameters remained stable over the study period, except for the gingival index, which was slightly, but significantly, higher in the test group at T3 (p = 0.039). The IMPA angle showed no intergroup difference. The two groups showed no significant difference in debonding events. Conclusions: This RCT conducted over a 12-month period demonstrated no significant difference between customized CAD/CAM nickel-titanium lingual retainers and standard stainless-steel lingual retainers in terms of dental anterior stability and retainer survival. Both retainers eventually appeared to be equally effective in maintaining periodontal health.