• Title/Summary/Keyword: Retained teeth

Search Result 97, Processing Time 0.023 seconds

OCCLUSAL VARIATIONS IN THE POSTERIOR AND ANTERIOR SEGMENTS OF THE TEETH (구치부와 전치부의 교합 상태에 관한 연구)

  • Lee, Ki-Soo;Chung, Kyu-Rim;Ko, Jin-Hwan;Koo, Chung-Hoe
    • The korean journal of orthodontics
    • /
    • v.10 no.1
    • /
    • pp.71-79
    • /
    • 1980
  • The purpose of this study was (1) to determine the prevalence of some causes by which dental occlusion might be affected , (2) to determine the prevalence of malocclusion, and types of molar, vertical incisor and horizontal incisor relationships, and (3) to examine the sex difference in the prevalence ratios, and (4) to determine the between-examiner differences in assessing types of dental occlusion. The material consisted of 1281 males and 811 females, total 2091 persons, aged 17 to 21 years. Two examiners who were graduate students in the orthodontic course, examined independently dental occlusion of the material. Before calculating the statistics, the subjects consisted of 156 mates and 164 females, total 320 persons, haying any one or more causes suspected to affect dental occlusion, was eliminated. Then the remained subjects, 1124 males and 647 females, total 1771 persons, were assessed. The results were as follows 1. The prevalence of some causes by which dental occlusion might be affected was 15.32 per cent. The missing rate of any one or more first molars was 8.85 percent, that of any one or more teeth positioned anterior to the first molar was 3.83 per cent. The prevalence of crossbite of the first molar was 0.48 per cent, that of retained primary teeth was 0.77 percent, and that of orthodontic treatment was 0.43 per cent. 8. The rate of between-examiner difference was 12.53 per cent in assessing the types of molar relationship, 18.86 percent in assessing the types of horizontal incisor relationship, and 26.37 percent in assessing the types of horizontal incisor relationship. 3. There was no sex difference in the prevalence ratios of the types of molar relationship. The prevalence of Class I molar relationship was 80.91 percent, that of Class II was 5,03, that of Class II subdivision was 4.01, Percent, that of Class III was 5.99 percent and that of Class III subdivision was 4.07 percent. 4. In the prevalence of the types of horizontal incisor relationship, there were no sex differences except that of Class II division 2. The prevalence of Class I horizontal incisor relationship was 73.12 percent, that of Class II division t was 12.03 percent, that of Class II division 2 was 6.58 percent in male and 4.33 percent in female, and that of Class III was 9.09 percent. 5. In the prevalence of the types of vertical incisor relationship, there were no sex differences except that of deep bite, The prevalence of open bite was 2.20 per cent, that of edge-to-edge bite was 9.15 percent, that of normal bite was 76,34 percent, and that of deep bite was 14.15 percent in male and 9.12 percent in female. 6. There was no sex difference in the prevalence of malocclusion the prevalence of malocclusion was 82.67 percent and that of normal occlusion was 17.33 percent. 7. There was a tendency that when Class I molar relationship changed to Class II, incisor relationships were to be larger overjet or upright upper incisors and deep bite, but when that changed to Class III molar relationship, these were to be cross bite and openbite.

  • PDF

An Esthetic Restoration of the Missing Maxillary Anterior Teeth with the Rotational Path RPD: A Case Report (회전삽입로 국소의치를 이용한 심미적 상악 전치부 수복 증례)

  • Lee, Ji-Hye;Lim, So-Min;Jung, Hye-Eun;Park, Chan-Jin;Cho, Lee-Ra;Kim, Dae-Gon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.209-222
    • /
    • 2011
  • Missing anterior teeth can be replaced using any of a number of methods. Patients may choose to replace missing teeth with a prosthesis that is either removable, fixed, or retained with implants. For patients faced with financial, anatomical, and/or esthetic limitations, the edentulous region can be restored successfully and esthetically with a properly designed and fabricated rotational path RPD. The rotational path RPD is a partial removable dental prosthesis that incorporates a curved, arcuate, or variable path of placement allowing one or more of the rigid components of the framework to gain access to and engage an undercut area. The rigid retainer must gain access to the infrabulge portion of the tooth by rotating into place. Either a minor connector or proximal plate provides retention through its intimate contact with a proximal tooth surface. A specially designed dovetails or asymmetric rest seats provides support and embracing effects. Correctly designed and fabricated rotational path RPD can provide improved esthetics, cleanliness, and retention. But rotational path RPDs are technique sensitive since the rotational path RPD has little margin of laboratory error that rigid retainers cannot be adjusted like conventional clasps can, RPD framework must be remade once the retention is lost. The sufficient understanding of the concept for the rotational path RPD is required for clinically successful treatment. This clinical report describes in detail the theoretical, laboratory considerations and the treatment of a patient with an anterior maxillary edentulous area treated by an AP path rotational RPD that had a difficulty in long term maintenance and describes another clinical case in which more reasonable treatment procedures were approached after analyzing the former case.

Esthetically improved complete denture by gingival shade alteration: a case report (무치악 환자에서 치은의 색조 개선을 통해 심미성을 향상 시킨 총의치 수복 증례)

  • Yim, Soo-Hyun;Kim, Jee-Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.239-245
    • /
    • 2014
  • Complete denture prosthodontics includes replacement of natural teeth and associated maxillary and mandibular structures for full edentulous patients. The final objectives of prosthodontic treatment include esthetic and functional rehabilitation. Because the esthetic demand of senior patients has increased esthetic requirement should not be overlooked in denture treatment. In complete denture treatment, attempts have been made to reproduce tooth wear, arrangement, recession of cervical gingiva, staining, improved gingival shade and so on. This 61 year old female patient came to the Department of Prosthodontics with the chief complaint that dentures made 5 years ago in a local clinic were broken and did not fit well. The patient put more emphasis on fabrication of natural and esthetic dentures than recovery of masticatory function. Remake of maxillary complete denture and mandibular implant retained overdenture was planned. In order to create esthetic and natural contour, Aesthetic Color Set Easy system$^{(R)}$ (Candulor dental GmbH, Wangen, Germany) was used to make complete dentures reproducing various gingival shades. Patient's esthetic satisfaction was high. When complete denture prosthodontics treatment involves appropriate expression of individual characteristics in addition to proper selection of esthetic materials, treatment will give satisfaction to both dentist and patient.

ORTHODONTIC TREATMENT WITH MINISCREWS IN MIXED DENTITION (혼합치열기의 miniscrew를 이용한 교정치료)

  • Lim, Su-Min;Yang, Yeon-Mi;Kim, Jae-Gon;Baik, Byeong-Ju;Lee, Yong-Hun;Shin, Jeong-Geun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.2
    • /
    • pp.367-375
    • /
    • 2008
  • Anchorage plays an important role in orthodontic treatment. Skeletal anchorage like the miniscrew is considered a more effective method in anchorage control than conventional anchorage which needs much patient's cooperation. The miniscrew offers many advantages. 1) It is easy to insert and to remove. 2) It can endure the force needed for moving teeth. 3) It can be immediately loaded and 4) Patient cooperation is not needed. 5) It is economic compared to other skeletal anchorage systems. In comparison to adult's bones, children's bones have comparatively poor bone quality and quantity. Therefore, it is hard to obtain primary stability in younger patients. However, if the miniscrew can be retained successfully, it will be effective in many orthodontic treatments. In these cases, we used the miniscrew in correcting of diastema, in aligning dental midline, and in rendering a forced eruption of impacted tooth in mixed dentition patient. We obtained satisfactory results.

  • PDF

A STRAIN GAUGE ANALYSIS OF IMPLANT-SUPPORTED CANTILEVERED FIXED PROSTHESIS UNDER DISTAL STATIC LOAD

  • Sohn, Byoung-Sup;Heo, Seong-Joo;Chang, Ik-Tae;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.717-723
    • /
    • 2007
  • Statement of problem. Unreasonable distal cantilevered implant-supported prosthesis can mask functional problems of reconstruction temporarily, but it can cause serious strain and stress around its supported implant and surrounding alveolar bone. Purpose. The purpose of this study was to evaluate strain of implants supporting distal cantilevered fixed prosthesis with two different cantilevered length under distal cantilevered static load. Material and methods. A partially edentulous mandibular test model was fabricated with auto-polymerizing resin (POLYUROCK; Metalor technologies, Stuttgart, Swiss) and artificial denture teeth (Endura; Shofu inc., Kyoto, Japan). Two implants-supported 5-unit screw-retained cantilevered fixed prosthesis was made using standard methods with Type III gold alloy (Harmony C&B55; Ivoclar-vivadent, Liechtenstein, Germany) for superstructure and reinforced hard resin (Tescera; Ivoclar-vivadent, Liechtenstein, Germany) for occlusal material. Two strain gauges (KFG-1-120-C1-11L1M2R; KYOWA electronic instruments, Tokyo, Japan) were then attached to the mesial and the distal surface of each standard abutment with adhesive (M-bond 200; Tokuyama, Tokyo, Japan). Total four strain gauges were attached to test model and connected to dynamic signal conditioning strain amplifier (CTA1000; Curiotech inc., Paju, Korea). The stepped $20{\sim}100$ N in 25 N increments, cantilevered static load 8mm apart (Group I) or 16mm apart (Group II), were applied using digital push-pull gauge (Push-Pull Scale & Digital Force Gauge, Axis inc., Seoul, Korea). Each step was performed ten times and every strain signal was monitored and recorded. Results. In case of Group I, the strain values were surveyed by $80.7{\sim}353.8{\mu}m$ in Ch1, $7.5{\sim}47.9{\mu}m/m$ in Ch2, $45.7{\sim}278.6{\mu}m/m$ in Ch3 and $-212.2{\sim}718.7{\mu}m/m$ in Ch4 depending on increasing cantilevered static load. On the other hand, the strain values of Group II were surveyed by $149.9{\sim}612.8{\mu}m/m$ in Ch1, $26.0{\sim}168.5{\mu}m/m$ in Ch2, $114.3{\sim}632.3{\mu}m/m$ in Ch3, and $-323.2{\sim}-894.7{\mu}m/m$ in Ch4. Conclusion. A comparative statistical analysis using paired sample t-test about Group I Vs Group II under distal cantilevered load shows that there are statistical significant differences for all 4 channels (P<0.05).

SURFACE ROUGHNESS AND MICROLEAKAGE OF CLASS V COMPOSITE RESTORATIONS : EFFECT OF SURFACE SEALING (치경부 5급 와동 수복물의 표면 거칠기와 미세누출에 관한 연구 : 표면 전색의 효과)

  • Kim, Min-Jeong;Lee, Mi-Jeong;Yu, Mi-Kyung;Park, Soo-Joung;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.1
    • /
    • pp.22-30
    • /
    • 2005
  • The purpose of this study was to compare the effect of surface sealing materials on microleakage and surface roughness in Class V composite restorations. Twenty five standardized Class V cavity preparations were made on the facial surface of human premolars and were randomly assigned to 5 groups. The teeth were restored with Z-250 after applying Single Bond. Following 7 days storage in distilled water at $37^{\circ}C$, the restorations were sealed as following systems : No sealing ; Single Bond Adhesive ; Biscover ; Fortify ; Optiguard. Then, toothbrush abrasion test was conducted using a wear testing machine. Surface roughness was measured by means of profilometer before and after toothbrushing and the results were statistically analysed by using a paired t-test and ANOVA. The bonded interfaces and the changes of surface roughness were examined by SEM. For microleakage test, specimens were stained in a $2\%$ methylene blue solution, then longitudinally sectioned and analyzed for leakage at occlusal and cervical interfaces using stereomicroscope. The results were statistically analysed by using a Kruskal-Wallis and Mann-Whitney U test. Surface roughness was increasing in all groups after toothbrushing, but no statistically significant differences. In SEM observation, surface sealant was partially retained and partially detached in bonded interfaces. Especially, microgap was identified in cervical margins. In microleakage test, there was better seal in the enamel region and a significant difference between groups at occlusal margin. Control group and Single Bond group had significantly better marginal seal at enamel margin than cervical margin.

Clinical evaluation of the removable partial dentures with implant fixed prostheses (임플란트 고정성 보철물을 이용한 가철성 국소의치의 합병증에 관한 임상적 평가)

  • Kang, Soo-Hyun;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.239-245
    • /
    • 2016
  • Purpose: The purpose of this study was to identify clinical complications in removable partial denture (RPD) with implant-supported surveyed prostheses, and to analyze the factors associated with the complications such as location of the implant, splinting adjacent prostheses, the type of retentive clasps, Kennedy classification, and opposing dentition. Materials and Methods: A retrospective clinical study was carried out for 11 patients (7 male, 4 female), mean age of 67.5, who received RPD with Implant-supported surveyed prostheses between 2000 and 2016. The mechanical complications of 11 RPDs and 37 supporting implant prostheses and the state of natural teeth and peripheral soft tissue were examined. Then the factors associated with the complications were analyzed. Results: The average of 3.4 implant-supported prostheses were used for each RPD. Complications found during the follow-up period of an average of 42.1 months were in order of dislodgement of temporary cement-retained prostheses, opposing tooth fracture/mobility, screw fracture/loosening, clasp loosening, veneer porcelain fracture, marginal bone resorption and mobility of implant, artificial tooth fracture. Complications occurred more frequently in anterior region compared to posterior region, non-splinted prostheses compared to splinted prostheses, surveyed prostheses applied by wrought wire clasp compared to other clasps, and natural dentition compared to other removable prostheses as opposing dentition. There were no significant differences in complications according to the Kennedy classification. Conclusion: All implant-assisted RPD functioned successfully throughout the follow-up. However, further clinical studies are necessary because the clinical evidences are still not enough to guarantee the satisfactory prognosis of implant-assisted RPD for long-term result.