• Title/Summary/Keyword: Retained teeth

Search Result 97, Processing Time 0.018 seconds

Long-term survival of retained deciduous mandibular second molars and maxillary canine incorporated into final occlusion

  • Hwang, Soonshin;Choi, Yoon Jeong;Chung, Chooryung J.;Kim, Kyung-Ho
    • The korean journal of orthodontics
    • /
    • v.47 no.5
    • /
    • pp.323-333
    • /
    • 2017
  • Orthodontic treatment of a complex case that involves retained deciduous mandibular second molars with missing permanent successors is challenging. Usually, congenitally missing teeth are manifested with other dental anomalies that further complicate orthodontic treatment, such as retained deciduous teeth, impactions, transpositions and peg-shaped lateral incisors. Even though the long term prognosis of the retained deciduous tooth is not fully predictable, if the teeth are in good condition, the patient and clinician may incline towards a decision to preserve the deciduous teeth as long as possible. This case report demonstrates that deciduous teeth, in this case the mandibular second molars and maxillary canine, can be incorporated into final occlusion with clinically stable long-term results.

Clinical Appliance of Konus Telescope Denture and Bar-Retained Overdenture on Partially Edenturous Patient (Bar attachment와 Konus telescope를 이용한 부분 무치악 환자의 수복)

  • Choi, Sung-Ho;Shim, Jun-Sung;Lee, Ho-Yong;Lee, Keun-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.2
    • /
    • pp.119-126
    • /
    • 2002
  • The purpose of this study was to restorate a patient who has a few remaining teeth with #15,23,24 supported Konus telescope denture in Maxillar and #44,43,33,34 supported Dolder bar retained overdenture in Mandible. Konus telescope and bar retained overdenture was taken better results in retention, support, stability compair with regular Removable partial denture. In Removable partial denture, the change of remaining teeth and edentulous ridge is natural. But Konus telescope and bar retained overdenture is a little effected in this change, so it is possiblble in long-term use. In cosider of patient's medical history and the possibility of additional tooth loss, Konus telescope denture can be easily repaired. Compaired with Konus telescope and bar retained overdenture showed high stability and easy cleansing because of rigid support, cross - arch splinting, and simple design. In delivery, patient had a difficulty with removal of denture and plaque control, but showed better condition, good oral hygienic care. Patient satisfied with denture functionally and esthetically. This study showed Konus telescope and bar retained overdenture was effective for treatment of patient remaing a few teeth in function, esthetic and psycologic satisfaction.

STRESS ANALYSIS AT SUPPORTING TISSUE OF ABUTMENT TEETH AND RESIDUAL RIDGE ACCORDING TO DENTURE DESIGN WITH REMAINING UNILATERAL POSTERIOR TEETH (편측 후방 치아 잔존시 의치 설계에 따른 지대치지지 조직과 잔존 치조제의 응력 분석에 관한 연구)

  • Ahn, Kwang-Ho;Jung, Young-Wan;Jin, Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.2
    • /
    • pp.185-199
    • /
    • 1999
  • This study was peformed to investigate the distribution and magnitude of stress at supporting tissue of abutment teeth and residual ridge tissue with remaining unilateral posterior teeth. Four types of removable partial dentures that included clasp retained removable partial denture, attachment retained removable partial denture, telescopic removable partial denture, and swing-lock partial denture were designed, and strain gauge was used for stress analysis. Each prosthesis was subjected to simulated vertical and oblique load. The following conclusions were drawn from this study. 1. The clasp retained removable partial denture generally distributed simulated vertical force more evenly to the supporting structure. 2. The stress at buccal side of 1st premolar was the lowest in swing-lock partial denture and that was highest in attchment retained removable partial denture. The stress at lingual side of 1st premolar was the lowest in telescopic partial denture. 3. In clasp retained removable partial denture, stress was lower at load site and ridge crest at mid-line, but it was higher at 1st premolar area on vertical load. 4. In attachment removable partial denture, stresses at buccal side of 1st premolar. lingual side of 1st premolar on vertical load, and ridge crest at midline on oblique load were higher. 5. In telescopic removable partial denture, stress at lingual side of 1st premolar was the least in all removable partial dentures, but the stress at load site was higher. 6. In swing-lock removable partial denture, stress at buccal side of 1st premolar was the lowest, and stresses at load site and distal end of residual ridge crest were higher.

  • PDF

A STUDY ON THE BOND STRENGTH OF RESIN-RETAINED PROTHESIS WITH VARIOUS CAST RETAINER DESIGNS (주조체의 설계 변화에 따른 수지접착형 보철물의 접착강도에 관한 연구)

  • Joo Dae-Won;Chang Ik-Tae;Kim Kwang-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.4
    • /
    • pp.508-525
    • /
    • 1992
  • The purpose of this study was to evaluate the effect of some resistance form designs on the bond strength of resin-retained prosthesis. Six sub-groups are designed in natural teeth group and resin teeth group . The framework designs in natural teeth group: 1) no groove preparation 2) groove at the center of distal surface 3) groove at the distobuccal line angle 4) 45 degree lateral load with no groove 5) 45 degree lateral load with center groove 6) splint two teeth with no groove. The framework designs in resin teeth group: 1) no groove preparation 2) groove at the center of distal surface 3) groove at the distobuccal line angle 4) metal covered the 1/2 of distal surface 5) metal covered the 1/2 of mesial surface 6) metal extended over the 114 of buccal surface. Specimens were treated electrolytic etching by Oxy-Etch and cemented with Panavia EX. Failure load was measured by Instron. Another 30 specimens were carried out fatigue tests by MTS 810 fatigue testing machine for 5000 cycles at different load level. The following results were obtained from this study. 1. The failure load was significantly increased by resistance forms. 2. The failure load was not increased by increase of total surface area bonded with teeth. The distal surface area played an important role in failure load. 3. In 45 degree lateral load group, the failure load was decreased significantly than that of in vertical load group. 4. Bond failure modes between static test and fatigue test exhibited no differences.

  • PDF

Autotransplantation of impacted teeth (임상가를 위한 특집 2 - 매복치의 자가치아이식)

  • Jang, Ki Taeg
    • The Journal of the Korean dental association
    • /
    • v.52 no.5
    • /
    • pp.273-280
    • /
    • 2014
  • Transplantation of one's own teeth from one site to another is called dental autotransplantation. The role of autotransplantation of teeth in several clinical situations, the clinical techniques involved and factors influencing success of the transplant are discussed. Autotransplantation of impacted or retained teeth is an appropriate treatment, if orthodontic traction has failed, especially in growing patients.

Reattachment of Fractured Teeth : Case Report

  • 김덕수;박상진;박상혁;최경규
    • Proceedings of the KACD Conference
    • /
    • 2004.05a
    • /
    • pp.304-308
    • /
    • 2004
  • Maxillary anterior crown fractures are a common form of injury that mainly affects children and adolescents. The position of maxillary incisors and their eruptive pattern carries a significant risk for trauma. In the pre-adhesive era, fractured teeth needed to be restored either with pin-retained inlays or cast restorations that sacrificed healthy tooth structure and were a challenge for dentists to match with adjacent teeth. But. recently the development of adhesive dentistry has allowed dentists to use the patient's own fragment to restore the fractured tooth. The purpose of this paper is to present 2 cases of reattachment of fractured teeth which had different fracture mode, and to evaluate prognosis of cases.

  • PDF

STRAIN ON THE LABIAL PLATES AROUND ABUTMENTS SUPPORTING REMOVABLE PARTIAL DENTURES WITH VARIOUS PROSTHETIC DESIGNS: AN IN VITRO STUDY

  • Kim, Seong-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.322-330
    • /
    • 2005
  • Statement of problem. In distal extension removable partial denture, the preservation of health of abutment teeth is very important, but abutment teeth are subjected to unfavorable stress. Purpose. The purpose of this study was to investigate the biomechanical effects of mandibular removable partial dentures with various prosthetic designs using strain gauge analysis. Material and methods. Artificial teeth of both canines were anchored bilaterally in a mandibular edentulous model made of resin. Bilateral distal extension removable partial dentures with splinted and unsplinted abutments were fabricated. Group 1 : Clasp-retained mandibular removable partial denture with unsplinted abuhnents Group 2 : Clasp-retained mandibular removable partial denture with splinted abutments by 6-unit bridge Group 3 : Bar-retained mandibular removable partial denture Strain gauges were bonded on the labial plate of the mandibular resin model, approximately 2 mm close to the abutments. Two vertical experimental loadings (100N and 200N) were applied subsequently via two miniature load cells that were placed at mandibular first molar regions. Strain measurements were performed and simultaneously monitored from a computer connected to data acquisition system. For within-group evaluations, t-test was used to compare the strain values and for between-group comparisons, a one-way analysis of variance (ANOVA) was used and Duncan test was used as post hoc comparisons. Results. Strain values increased as the applied load increased from 100N to 200N for all groups (p<.05). The strain values of group 1 and 2 were tensile under loadings. In contrast, strain values of group 3 were compressive in nature. Under 100N loading, group 1 showed higher strain values than group 3 in absolute quantity (p<.05). Under 200N loading, group 3 showed higher strain values than group 1 and 2 in absolute quantity (p<.05). Group 1 showed higher strain values than group 2 (p<.05). Conclusion. Splinting of two isolated abutments by bridge reduced the peri-abutment strain in comparison with unsplinted abutments. Strain of bar-retained removable partial denture increased much more as applied load increased, but was compressive in nature.

Clinical outcomes of rigid and non-rigid telescopic double-crown-retained removable dental prostheses: An analytical review

  • Seo, Jeong-Gyo;Cho, Jin-Hyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.1
    • /
    • pp.38-48
    • /
    • 2020
  • PURPOSE. The objective of this literature review was to analyze the cumulative survival rates (CSRs) of rigid and non-rigid double-crown-retained removable dental prostheses. MATERIALS AND METHODS. Screening of the literature published from January 1995 to December 2019 was performed by using electronic data base (Pubmed) and manual search. The CSRs of rigid and non-rigid double crown removable dental prostheses were investigated. RESULTS. A total of 403 articles were reviewed and 56 relevant articles of them were selected. Subsequently, 25 articles were included for data extraction. These articles were classified according to rigid and non-rigid type double crowns and further subdivided into teeth, implants, and teeth-implant combination types. The CSRs of rigid type double crown ranged from 68.9% to 95.1% of 5 to 10 years in tooth abutments, 94.02% to 100% over a 3-year mean observation periods in implant abutments, and 81.8% to 97.6% in tooth-implant combination. Non-rigid type double crowns had various CSR ranges from 34% to 94% maximum during 10 years observation in teeth abutment. The CSRs of non-rigid type had over 98% in implant abutments, and ranged from 85% to 100% in tooth-implant combination. CONCLUSION. The CSRs of double crowns varies according to types. With accurate evaluation of the remaining teeth and plan of the strategic implant placement, it could be successful treatment alternatives for partially or completely edentulous patients.

Dental Status and Oral Function in Some Long-term Care Elderly Patients (일부 노인장기요양환자의 구강실태 및 구강기능)

  • Lee, Yun-Hui;Yoon, Hee-Jung;Lee, Hee-Keung;Lee, Sung-Kook
    • Korean Journal of Health Education and Promotion
    • /
    • v.25 no.4
    • /
    • pp.55-65
    • /
    • 2008
  • Objective: This study aims to investigate the relationship between dental status and oral function by analyzing those in some long-term care elderly patients. Methods: It performed oral examination and 4 oromotor function examinations such as repeated swallowing function, correct pronunciation function, saliva secretion rate and maximum mouth opening to 91 elderly patents aged 65 and older in the municipal geriatric hospital located in Cheonan. Results: Dental status of patients such as the number of dental caries, treated teeth, retained teeth and function teeth were better in mobile elderly patients than in immobile elderly patients. Attachment rate of dental plaque and the number of teeth being extracted were more in mobile patients than in immobile patients. More retained teeth, the number of function teeth and dental caries and the score in pronunciation status test were significantly higher. With more function teeth, the score in pronunciation status test was significantly higher. As saliva secretion rate is higher, repeated swallowing function was significantly better. repeated swallowing function rate is higher pronunciation status was significantly better. Conclusions: With the results of this study, it was found that among long-term care elderly patients, oral function was worse in immobile patients than in mobile patients. Therefore, it may be necessary to plan and perform an oral function improvement program preferentially for elderly patients requiring long-term care.

A STUDY OF DENTINOGENESIS IMPERFECTA (상아질형성부전증에 관한 연구)

  • Choi Eui-Whan
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.2
    • /
    • pp.215-219
    • /
    • 1992
  • The author ovserved a case of dentinogenesis imperfecta in a 8-year-old and a 9-year-old brother with complaints of abnormal morphologic changes of the teeth. 1. Clinically, yellowish brown colored teeth, fractured crown and numerous retained root tips of deciduous teeth with severe attrition were observed in the both deciduous and permanent dentitions. 2 Radiographically, small-sized teeth, partial or complete obliteration of the pulp chambers and pulp canals in the anterior teeth, partial obliteration of the pulp chambers and thin enamel in the permanent tooth germs were observed. 3. The familial history was their father has been lose his teeth early.

  • PDF