• 제목/요약/키워드: Results of field application

검색결과 3,480건 처리시간 0.036초

초지연제의 응결시간차를 이용한 매스 콘크리트의 수화열 저감을 위한 현장 적용 (Field Application of Mass Concrete Using Setting Time Difference of Super Retarding Agent for Reduction of Hydration Heat)

  • 전충근;심보길;손성운;신동안;오선교;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2004년도 학술.기술논문발표회
    • /
    • pp.11-14
    • /
    • 2004
  • In this paper, field application of mass concrete using setting time difference of super retarding agent is reported to reduce hydration heat of concrete placed at newly constructed apartment house in Busan. Horizontal placing lift is applied. According to test results. slump and air content meets the requirement of target values. For compressive strength, it exceeds the nominal strength ordered by the costumer. Compressive strength of concrete cured in place is achieved more than the values of nominal strength at l4days. For temperature history, maximum temperature of center at top section shows 58.5$^{\circ}C$, and at bottom section, 62.6$^{\circ}C$. According to naked eye's investigation, no hydration heat crack is observed at the surface of concrete.

  • PDF

건설교통R&D성과의 건설신기술 연계방안 (Connection Program of Construction New Technology and Results of Construction Transportation R&D)

  • 박환표;이교선
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2010년도 춘계 학술논문 발표대회 2부
    • /
    • pp.17-20
    • /
    • 2010
  • Recent Construction and Transportation R&D projects are larger in size, investment scale has been increasing rapidly. However, the results of Construction and Transportation in R & D are papers, patents and other results. So, the application record of R&D in the construction field is very lacking. In particular, Construction New Technology's ratio in the midst of R&D's results are about 2.29%. Therefore, this study suggested program that R&D's results has been connected Construction New Technology. The introduction of the new system has greatly increased Construction New Technology and the results of excellent &D will be applied in construction field. So, Cost-reduction and technology's improvement are expected.

  • PDF

Application of Compressive Sensing to Two-Dimensional Radar Imaging Using a Frequency-Scanned Microstrip Leaky Wave Antenna

  • Yang, Shang-Te;Ling, Hao
    • Journal of electromagnetic engineering and science
    • /
    • 제17권3호
    • /
    • pp.113-119
    • /
    • 2017
  • The application of compressive sensing (CS) to a radar imaging system based on a frequency-scanned microstrip leaky wave antenna is investigated. First, an analytical model of the system matrix is formulated as the basis for the inversion algorithm. Then, $L_1-norm$ minimization is applied to the inverse problem to generate a range-azimuth image of the scene. Because of the antenna length, the near-field effect is considered in the CS formulation to properly image close-in targets. The resolving capability of the combined frequency-scanned antenna and CS processing is examined and compared to results based on the short-time Fourier transform and the pseudo-inverse. Both simulation and measurement data are tested to show the system performance in terms of image resolution.

내한촉진제를 사용한 한중콘크리트의 현장적용 (Application of Cold Weather Concrete using Accelerator for Freeze Protection)

  • 박상준;원철;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.13.2-17
    • /
    • 2003
  • When fresh concrete is exposed to low temperature, the concrete may suffer frost damage due to freezing at early ages and strength development may be delayed. One of the solution methods to resolve these problems is to lower freezing temperature of concrete by the use of chemical admixture called Accelerators for Freeze Protection. In this study, it was the results of appling cold weather concrete using Accelerator for Freeze Protection in the Daewoo Trump world field. Before the application of the cold weather concrete using accelerator for freeze protection, we executed the some test in the laboratory and mock-up test in the field. We examined the manifestation of compressive strength complying with the amount of Accelerators for Freeze Protection and curing conditions, and then made a selection of most suitable amount of Accelerators for Freeze Protection.

  • PDF

매스콘크리트의 수화열저감을 위한 초지연제 응결시간차 공법의 현장 적용 -대전 가오지구 코오롱 하늘채 아파트 현장- (Field Application of Setting Time Difference Method Using SRA for Reduction of Hydration Heat of Mass Concrete)

  • 전충근;김종;신동안;윤기원;오선교;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 춘계 학술기술논문발표대회 논문집
    • /
    • pp.21-24
    • /
    • 2005
  • In this paper, field application of mass concrete using setting time difference of super retarding agent is reported to reduce hydration heat of concrete placed at newly constructed apartment house in Daejeon. Horizontal placing lift is applied. According to test results,: slump and air content meets the requirement of target values. For compressive strength, it exceeds the nominal strength ordered by the costumer. For temperature history, maximum temperature of center at top section shows $25.6^{\circ}C$, and at bottom section, $35.4^{\circ}C$. According to naked eye's investigation, no hydration heat crack is observed at the surface of concrete.

  • PDF

풍력발전을 위한 소용량 영구자석형 동기발전기의 설계 및 해석 (Design and Analysis of Direct-Coupled, Small-Scaled Permanent Magnet Generator for Wind Power Application)

  • 김일중;최장영
    • 조명전기설비학회논문지
    • /
    • 제28권5호
    • /
    • pp.39-51
    • /
    • 2014
  • This paper deals with design of a direct-coupled, small-scaled permanent magnet generator (PMG) for wind power application. First, this paper determines rated power and speed of the PMG from measured characteristics of wind turbines. Second, we derive analytical solutions for the open-circuit field in order to determine optimum magnet thickness and pole pitch/arc ratio. Third, on the basis of open circuit field solutions, stator magnetic circuit including slot opening, teeth width and yoke thickness is designed. And then, a diameter of stator coil which agree with a required current density is calculated, and its turns are determined from the area of slot considering winding packing factor. Finally, finite element (FE) method is employed in analyzing the details of the designed PMG and, test results such as back-emf measurements are given to confirm the design.

레드머드와 착색재를 이용한 컬러 콘크리트 패널 현장적용 (Filed Application of the Color Concrete Panel with Red Mud and Pigment)

  • 김태청;김종;전충근;연규원;윤기원;신동안
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.19-22
    • /
    • 2009
  • The Study has analyzed the overall material properties, the measurement of forming colors and applicability of color concrete through making color concrete using red mud heated at 800℃mixed with existing pigment and applying it to the actual field. As the results, the slump flow and aeration meet the target value and the compressed strength of the concrete mixed with red mud and pigment is higher than that of the plain. In addition, the measurement of forming colors turn out to be satisfactory and the color forming is excellent. In the field application, the color concrete panel is proved to make sure the beauty of store exits through its various design available.

  • PDF

공중주택의 열환경분석과 바닥복사냉방의 적용에 관한 연구 (A Study on the Thermal Environmental Analysis and the Application of Radiant Floor Cooling in Apartment Building)

  • 김용이;김광우
    • 설비공학논문집
    • /
    • 제13권6호
    • /
    • pp.541-548
    • /
    • 2001
  • The objective of this study is to analyze the possibilities and considerations for the application of the radiant floor cooling system by analyzing the problems of a conventional cooling system through field tests and thermal performance simulations of the radiant floor cooling in an apartment building. The results are as follows. (1) Problems of he conventional cooling system with PAC()packaged air conditioner)'s include draft, local discomfort, and excessive electrical peak demand. (2) According to the measurement during the cooling and intermediate seasons, the floor surface temperatures which are experienced at the time of cooling with PAC\`s and during intermediate season are similar to the temperatures for radiant floor cooling. (3) The radiant floor cooling system is applicable to apartment buildings during the cooling season, especially on hot and clear days.

  • PDF

지반 구조의 불확실성이 고려된 1차원 확률론적 지반응답해석 (1D Probabilistic Ground Response Analysis)

  • 황혜진;박형춘
    • 한국지진공학회논문집
    • /
    • 제18권2호
    • /
    • pp.73-78
    • /
    • 2014
  • In this paper, the stochastic 1D site response analysis method using Monte Carlo simulation and considering thespatial variation of shear wave velocity profile isproposed. To consider thespatial variation of shear wave velocity profile for 1D site response analysis, the proposed method generates random shear wave velocity profiles representing the target site, and Monte Carlo simulation is used to calculate theprobability distribution of the site response analysis results such as thepeak ground acceleration. Through the field application, The applicability of the proposed method is verified through field application.

바텀애쉬를 이용한 EPS경량콘크리트패널의 차음성능에 관한 실험적 연구 (The Experiment Study on Site Application of the Light weight Concrete Panel Using Bottom Ash)

  • 선정수;김하석;서정필;강철;정갑철;김진만
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.645-648
    • /
    • 2006
  • Recently, the method of the apartment building design has been changed from wall type structures to rahmen structures. With like this reason, dry walls are used plentifully. Especially, the gypsum board was used from previously plentifully however the weak point of it is difficult to maintain because it weak strength. For the improvement of gypsum board, light weight concrete panel using cement board is used recently. As this study is the research of the series t on the development of non-bearing light weight concrete panel using bottom ash, the purpose of this study is to obtain basic data for application in the field. The results are as follows. structure 1 satisfy domestic standard concerned with sound insulation between households at the laboratory and field test.