• Title/Summary/Keyword: Restorative design

Search Result 122, Processing Time 0.026 seconds

The effect of sandblasting duration on the bond durability of dual-cure adhesive cement to CAD/CAM resin restoratives

  • Tekce, Neslihan;Tuncer, Safa;Demirci, Mustafa
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.211-217
    • /
    • 2018
  • PURPOSE. To evaluate the effect of prolonged sandblasting on the bond durability of dual-cure adhesive resin cement to computer-aided design and computer-aided manufacturing (CAD/CAM) restoratives. MATERIALS AND METHODS. Nano-ceramic LAVA Ultimate and hybrid-ceramic VITA Enamic CAD/CAM blocks were used for this study. Each CAD/CAM block was sectioned into slabs of 4-mm thickness for the microtensile test (${\mu}TBS$) test and 2-mm thickness for the surface roughness test. Three groups were created according to the sandblasting protocols; group 1: specimens were sandblasted for 15 seconds, group 2: specimens were sandblasted for 30 seconds, and group 3: specimens were sandblasted for 60 seconds. After sandblasting, all specimens were luted using RelyX Ultimate Clicker. Half the specimens were subjected to ${\mu}TBS$ tests at 24 hours, and the other half were subjected to tests after 5000 thermocycles. Additionally, a total of 96 CAD/CAM block sections were prepared for surface roughness tests and scanning electron microscopy (SEM) evaluations. The Mann-Whitney U test, Kruskal-Wallis one-way analysis of variance, and Dunn's post hoc test were used to compare continuous variables among the groups. RESULTS. At baseline, group 1, group 2, and group 3 exhibited statistically similar ${\mu}TBS$ results for LAVA. However, group 3 had significantly lower ${\mu}TBS$ values than groups 1 and 2 for VITA. After 5000 thermocycles, ${\mu}TBS$ values significantly decreased for each block (P<.05). CONCLUSION. It is important to perform controlled sandblasting because it may affect bond strength results. Sixty seconds of sandblasting disturbs the initial ${\mu}TBS$ values and the stability of adhesion of CAD/CAM restoratives to dual-cure adhesive resin cement for VITA Enamic.

Analysis of the Characteristics of Biophilic Design in 『Soswaewon 48 Yeong』 (『소쇄원 48영』에 나타난 바이오필릭 디자인 특성분석)

  • Lee, Hyung-Sook;Choi, Mi-Seon
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.40 no.4
    • /
    • pp.58-66
    • /
    • 2022
  • Biophilic design is an approach that attempts to connect people with nature to promote health, recovery and restoration processes. The purpose of this study was to systematically analyze restorative factors and characteristics of Soswaewon by applying a biophilic design analysis framework. To this end, a biophilic design classification system was established and content analysis and frequency analysis were conducted for 『Soswaewon 48 Young』. the ratio of plant words including bamboo, pine, and plum was the highest, and words related to dynamic water flow or interaction with water as well as various water types such as streams, waterfalls, and ponds were also high. appeared in rank. In addition, multisensory factors, seasonal changes, microclimatic factors, emotional elements that allow people to indirectly experience nature were expressed in various ways. The space layout and circulation provide opportunities to appreciate and experience the rich sensory resources of Soswaewon. In conclusion, this study confirmed the healing and restorative value of Soswaewon from the perspective of biophilic design, and it needs further research on the restorative factors of traditional spaces.

Fabrication of custom abutment using dental CAD/CAM system (임상가를 위한 특집 2 - CAD/CAM 시스템을 이용한 Custom abutment의 제작)

  • Kim, Hyeong-Seob
    • The Journal of the Korean dental association
    • /
    • v.50 no.3
    • /
    • pp.118-125
    • /
    • 2012
  • CAD/CAM systems (computer-aided design / computer-aided manufacturing) used for decades in restorative dentistry have its application to implant dentistry. This study aimed to overview CAD/CAM systems used implant dentistry, especially emphasizing custom implant abutments manufacturing. CAD/CAM custom abutments present the advantages of being specific to each patient and providing a better fit than the stock and cast custom abutments. This cutting edge technology of virtual-designed and computer-milled implant abutments will likely replace traditional implant restorative protocols and become the standard for implant dentistry in the foreseeable future.

Clinical considerations of CAD/CAM restoration (CAD/CAM 수복의 임상적 고찰)

  • Kim, Hyun-Jung
    • The Journal of the Korean dental association
    • /
    • v.57 no.3
    • /
    • pp.169-174
    • /
    • 2019
  • The rapid evolution of CAD/CAM (Computer Aided Design / Computer Aided Manufacture) led to a dramatic impact on all disciplines of dentistry especially in the fields of prosthodontics and restorative dentistry. This article is to examine the history, advantages & disadvantages and some clinical considerations of CAD/CAM restoration.

  • PDF

Discoloration of various CAD/CAM blocks after immersion in coffee

  • Lauvahutanon, Sasipin;Shiozawa, Maho;Takahashi, Hidekazu;Iwasaki, Naohiko;Oki, Meiko;Finger, Werner J.;Arksornnukit, Mansuang
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.1
    • /
    • pp.9-18
    • /
    • 2017
  • Objectives: This study evaluated color differences (${\Delta}Es$) and translucency parameter changes (${\Delta}TPs$) of various computer-aided design/computer-aided manufacturing (CAD/CAM) blocks after immersion in coffee. Materials and Methods: Eight CAD/CAM blocks and four restorative composite resins were evaluated. The CIE $L^{\ast}a^{\ast}b^{\ast}$ values of 2.0 mm thick disk-shaped specimens were measured using the spectrophotometer on white and black backgrounds (n = 6). The ${\Delta}Es$ and ${\Delta}TPs$ of one day, one week, and one month immersion in coffee or water were calculated. The values of each material were analyzed by two-way ANOVA and Tukey's multiple comparisons (${\alpha}=0.05$). The ${\Delta}Es$ after prophylaxis paste polishing of 1 month coffee immersion specimens, water sorption and solubility were also evaluated. Results: After one month in coffee, ${\Delta}Es$ of CAD/CAM composite resin blocks and restorative composites ranged from 1.6 to 3.7 and from 2.1 to 7.9, respectively, and ${\Delta}TPs$ decreased. The ANOVA of ${\Delta}Es$ and ${\Delta}TPs$ revealed significant differences in two main factors, immersion periods and media, and their interaction except for ${\Delta}Es$ of TEL (Telio CAD, Ivoclar Vivadent). The ${\Delta}Es$ significantly decreased after prophylaxis polishing except GRA (Gradia Block, GC). There was no significant correlation between ${\Delta}Es$ and water sorption or solubility in water. Conclusions: The ${\Delta}Es$ of CAD/CAM blocks after immersion in coffee varied among products and were comparable to those of restorative composite resins. The discoloration of CAD/CAM composite resin blocks could be effectively removed with prophylaxis paste polishing, while that of some restorative composites could not be removed.

Effect of surface treatments and universal adhesive application on the microshear bond strength of CAD/CAM materials

  • Sismanoglu, Soner;Gurcan, Aliye Tugce;Yildirim-Bilmez, Zuhal;Turunc-Oguzman, Rana;Gumustas, Burak
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.1
    • /
    • pp.22-32
    • /
    • 2020
  • PURPOSE. The aim of this study was to evaluate the microshear bond strength (µSBS) of four computer-aided design/computer-aided manufacturing (CAD/CAM) blocks repaired with composite resin using three different surface treatment protocols. MATERIALS AND METHODS. Four different CAD/CAM blocks were used in this study: (1) flexible hybrid ceramic (FHC), (2) resin nanoceramic (RNC), (c) polymer infiltrated ceramic network (PICN) and (4) feldspar ceramic (FC). All groups were further divided into four subgroups according to surface treatment: control, hydrofluoric acid etching (HF), air-borne particle abrasion with aluminum oxide (AlO), and tribochemical silica coating (TSC). After surface treatments, silane was applied to half of the specimens. Then, a silane-containing universal adhesive was applied, and specimens were repaired with a composite, Next, µSBS test was performed. Additional specimens were examined with a contact profilometer and scanning electron microscopy. The data were analyzed with ANOVA and Tukey tests. RESULTS. The findings revealed that silane application yielded higher µSBS values (P<.05). All surface treatments were showed a significant increase in µSBS values compared to the control (P<.05). For FHC and RNC, the most influential treatments were AlO and TSC (P<.05). CONCLUSION. Surface treatment is mandatory when the silane is not preferred, but the best bond strength values were obtained with the combination of surface treatment and silane application. HF provides improved bond strength when the ceramic content of material increases, whereas AlO and TSC gives improved bond strength when the composite content of material increases.

The effects of different surface treatments on the shear bond strengths of two dual-cure resin cements to CAD/CAM restorative materials

  • Turker, Nurullah;Buyukkaplan, Ulviye Sebnem;Basar, Ebru Kaya;Ozarslan, Mehmet Mustafa
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.4
    • /
    • pp.189-196
    • /
    • 2020
  • PURPOSE. The aim of the present study was to investigate the effects of surface treatments on the bond strengths between polymer-containing restorative materials and two dual-cure resin cements. MATERIALS AND METHODS. In the present study, rectangular samples prepared from Lava Ultimate (LU) and Vita Enamic (VE) blocks were used. The specimen surfaces were treated using CoJet sandblasting, 50 ㎛ Al2O3 sandblasting, % 9 HF (hydrofluoric) acid, ER,Cr:YSGG laser treatment, and Z-Prime. Dual-cure resin cements (TheraCem and 3M RelyX U 200) were applied on each specimen's treated surface. A micro-tensile device was used to evaluate shear bond strength. Statistical analysis was performed using the SAS 9.4v3. RESULTS. While the bond strength using TheraCem with LU or VE was not statistically significant (P=.164), the bond strength using U200 with VE was statistically significant (P=.006). In the TheraCem applied VE groups, Z-Prime and HF acid were statistically different from CoJet, Laser, and Sandblast groups. In comparison of TheraCem used LU group, there was a statistically significant difference between HF acid and other surface treatments. CONCLUSION. The bonding performance between the restorative materials and cements were material type-dependent and surface treatment had a large effect on the bond strength. Within the limitations of the study, the use of both U200 and TheraCem may be suggested if Z-prime was applied to intaglio surfaces of VE. The cementation of LU using TheraCem is suitable after HF acid conditioning of the restoration surfaces.

Light transmittance of CAD/CAM ceramics with different shades and thicknesses and microhardness of the underlying light-cured resin cement

  • Jafari, Zahra;Alaghehmand, Homayoon;Samani, Yasaman;Mahdian, Mina;Khafri, Soraya
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.3
    • /
    • pp.27.1-27.9
    • /
    • 2018
  • Objectives: The aim of this in vitro study was to evaluate the effects of the thickness and shade of 3 types of computer-aided design/computer-aided manufacturing (CAD/CAM) materials. Materials and Methods: A total of 120 specimens of 2 shades (A1 and A3) and 2 thicknesses (1 and 2 mm) were fabricated using VITA Mark II (VM; VITA Zahnfabrik), IPS e.max CAD (IE; IvoclarVivadent), and VITA Suprinity (VS; VITA Zahnfabrik) (n = 10 per subgroup). The amount of light transmission through the ceramic specimens was measured by a radiometer (Optilux, Kerr). Light-cured resin cement samples (Choice 2, Bisco) were fabricated in a Teflon mold and activated through the various ceramics with different shades and thicknesses using an LED unit (Bluephase, IvoclarVivadent). In the control group, the resin cement sample was directly light-cured without any ceramic. Vickers microhardness indentations were made on the resin surfaces (KoopaPazhoohesh) after 24 hours of dark storage in a $37^{\circ}C$ incubator. Data were analyzed using analysis of variance followed by the Tukey post hoc test (${\alpha}=0.05$). Results: Ceramic thickness and shade had significant effects on light transmission and the microhardness of all specimens (p < 0.05). The mean values of light transmittance and microhardness of the resin cement in the VM group were significantly higher than those observed in the IE and VS groups. The lowest microhardness was observed in the VS group, due to the lowest level of light transmission (p < 0.05). Conclusion: Greater thickness and darker shades of the 3 types of CAD/CAM ceramics significantly decreased the microhardness of the underlying resin cement.

Microtensile bond strength of CAD/CAM-fabricated polymer-ceramics to different adhesive resin cements

  • Sadighpour, Leyla;Geramipanah, Farideh;Ghasri, Zahra;Neshatian, Mehrnoosh
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.4
    • /
    • pp.40.1-40.10
    • /
    • 2018
  • Objectives: This study evaluated the microtensile bond strength (${\mu}TBS$) of polymer-ceramic and indirect composite resin with 3 classes of resin cements. Materials and Methods: Two computer-aided design/computer-aided manufacturing (CAD/CAM)-fabricated polymer-ceramics (Enamic [ENA; Vita] and Lava Ultimate [LAV; 3M ESPE]) and a laboratory indirect composite resin (Gradia [GRA; GC Corp.]) were equally divided into 6 groups (n = 18) with 3 classes of resin cements: Variolink N (VAR; Vivadent), RelyX U200 (RXU; 3M ESPE), and Panavia F2 (PAN; Kuraray). The ${\mu}TBS$ values were compared between groups by 2-way analysis of variance and the post hoc Tamhane test (${\alpha}=0.05$). Results: Restorative materials and resin cements significantly influenced ${\mu}TBS$ (p < 0.05). In the GRA group, the highest ${\mu}TBS$ was found with RXU ($27.40{\pm}5.39N$) and the lowest with VAR ($13.54{\pm}6.04N$) (p < 0.05). Similar trends were observed in the ENA group. In the LAV group, the highest ${\mu}TBS$ was observed with VAR ($27.45{\pm}5.84N$) and the lowest with PAN ($10.67{\pm}4.37N$) (p < 0.05). PAN had comparable results to those of ENA and GRA, whereas the ${\mu}TBS$ values were significantly lower with LAV (p = 0.001). The highest bond strength of RXU was found with GRA ($27.40{\pm}5.39N$, p = 0.001). PAN showed the lowest ${\mu}TBS$ with LAV ($10.67{\pm}4.37N$; p < 0.001). Conclusions: When applied according to the manufacturers' recommendations, the ${\mu}TBS$ of polymer-ceramic CAD/CAM materials and indirect composites is influenced by the luting cements.

FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION ACCORDING TO CAVITY DESIGN OF CLASS V COMPOSITE RESIN FILLING (5급와동의 복합레진 충전에 관한 유한요소법적 응력분석)

  • Um, Chung-Moon;Kwon, Hyuk-Choon;Son, Ho-Hyun;Cho, Byeong-Hoon;Rim, Young-Il
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.67-75
    • /
    • 1999
  • The use of composite restorative materials is established due to continuing improvements in the materials and restorative techniques. Composite resins are widely used for the restoration of cervical lesions because of esthetics, good physical properties and working time. There are several types of cavity design for class V composite resin filling, but inappropriate cavity form may affect bonding failure, microleakage and fracture during mastication. Cavity preparations for composite materials should be as conservative as possible. The extent of the preparation is usually determined by the size, shape, and location of the defect. The design of the cavity preparation to receive a composite restoration may vary depending on several factors. In this study, 5 types of class V cavity were prepared on each maxillary central incisor. The types are; 1) V-shape, 2) round(U) shape, 3) box form, 4) box form with incisal bevel and 5) box form with incisal bevel and grooves for axial line angles. After restoration, in order to observe the concentration of stress at bonding surfaces of teeth and restorations, developing a 2-dimensional finite element model of labiopalatal section in tooth, surrounding bone, periodontal ligament and gingiva, based on the measurements by Wheeler, loading force from direction of 45 degrees from lingual side near the incisal edge was applied. This study analysed Von Mises stress with SuperSap finite element analysis program(Algor Interactive System, Inc.). The results were as follows : 1. Stress concentration was prevalent at tooth-resin bonding surface of cervical side on each model. 2. In model 2 without line angle, stress was distributed evenly. 3. Preparing bevel eliminated stress concentration much or less at line angle. 4. Model with round-shape distributed stress concentration more evenly than box-type model with sharp line angle, therefore decreased possibility of fracture. 5. Adding grooves to line angles had no effect of decreasing stress concentration to the area.

  • PDF