• Title/Summary/Keyword: Restorative composite resin

Search Result 567, Processing Time 0.036 seconds

EFFECT OF CHLORHEXIDINE ON MICROTENSILE BOND STRENGTH OF DENTIN BONDING SYSTEMS (Chlorhexidine 처리가 상아질 접착제의 미세인장결합강도에 미치는 영향)

  • Oh, Eun-Hwa;Choi, Kyoung-Kyu;Kim, Jong-Ryul;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.148-161
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of chlorhexidine (CHX) on microtensile bond strength (${\mu}TBS$) of dentin bonding systems. Dentin collagenolytic and gelatinolytic activities can be suppressed by protease inhibitors, indicating that MMPs (Matrix metalloproteinases) inhibition could be beneficial in the preservation of hybrid layers. Chlorhexidine (CHX) is known as an inhibitor of MMPs activity in vitro. The experiment was proceeded as follows: At first, flat occlusal surfaces were prepared on mid-coronal dentin of extracted third molars. GI (Glass Ionomer) group was treated with dentin conditioner, and then, applied with 2 % CHX. Both SM (Scotchbond Multipurpose) and SB (Single Bond) group were applied with CHX after acid-etched with 37% phosphoric acid. TS (Clearfil Tri-S) group was applied with CHX, and then, with adhesives. Hybrid composite Z-250 and resin-modified glass ionomer Fuji-II LC was built up on experimental dentin surfaces. Half of them were subjected to 10,000 thermocycle, while the others were tested immediately. With the resulting data, statistically two-way ANOVA was performed to assess the ${\mu}TBS$ before and after thermo cycling and the effect of CHX. All statistical tests were carried out at the 95 % level of confidence. The failure mode of the testing samples was observed under a scanning electron microscopy (SEM). Within limited results, the results of this study were as follows; 1. In all experimental groups applied with 2 % chlorhexidine, the microtensile bond strength increased, and thermo cycling decreased the micro tensile bond strength (P > 0.05). 2. Compared to the thermocycling groups without chlorhexidine, those with both thermocycling and chlorhexidine showed higher microtensile bond strength, and there was significant difference especially in GI and TS groups. 3. SEM analysis of failure mode distribution revealed the adhesive failure at hybrid layer in most of the specimen. and the shift of the failure site from bottom to top of the hybrid layer with chlorhexidine groups. 2 % chlorhexidine application after acid-etching proved to preserve the durability of the hybrid layer and microtensile bond strength of dentin bonding systems.

EFFECTS OF MOISTENING OF ETCHED DENTIN AND ENAMEL SURFACES ON BOND STRENGTH (산 표면처리후 상아질과 법랑질 표면의 습윤이 결합강도에 미치는 영향)

  • Lee, Kwang-Won;Park, Soo-Joung;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.328-341
    • /
    • 1995
  • I. Shear Bond Strength to Air-dried and Remoistened Dentin.. The effect of air-drying and remoistening of acid-conditioned dentin before priming with the primer of All-Bond 2(BISCO. INC., U. S. A.) on shear bond strength(SBS) was investigated. Ninty freshly extracted sound human molars were divided at random into 9 groups of 10 teeth each. SBSs were meaured for acid-conditioned and non-conditioned dentin to which the primer and bonding agent of All-Bond 2 and composite resin(Z-100, 3M Dental Products, U. S. A.) were applied. The following values(Mean${\pm}$ SD, MPa) were obtained for the groups conditioned with 10% phosphoric acid for 15 seconds: Group l(blot dried) $6.7{\pm}4.1$ ; Group 2(10 seconds dried) $16.1{\pm}5.3$ ; Group 3(20 seconds dried) $15.4{\pm}4.8$ ; Group 4(30 seconds dried) $15.2{\pm}6.3$ ; Group 5(10 seconds dried/remoistened) $26.4{\pm}2.6$ ; Group 6(20 seconds dired/remositened) $22.2{\pm}2.7$ ; Group 7(30 seconds dried/remoistened) $21.5{\pm}4.1$. For the non-conditioned groups the values were: Group 8 (blot dried) $13.3{\pm}2.6$ ; Group 9(10 seconds dried) $12.9{\pm}3.5$. The data were analyzed using ANOVA. In the acid-conditioned groups, mean values of SBS for the air-dried specimens(Grps. 2, 3 and 4) and the 20 and 30 seconds dried/remoistened specimens (Grps. 6 and 7) were significantly lower than that of blot dried specimens.(p<0.05) The value for 10 seconds dried/remoistened specimens (Grp. 5), however, was not statistically different compared to that of blot dried specimens.(p>0.05) In the non-conditined groups, there was no statistical difference between blot dried and 10 seconds dried specimens.(p>0.05) The results suggest that the acid-conditioned dentin surface is more vulnerable to dentin bonding when it is air-dried or even remoistened after long period of drying. II. Shear bond stengh to the moistened and primed enamel. The effect of moistening and priming of enamel compared to the air-drying of enamel on the shear bond strength of enamel bonding agent was investigated. The experiment was divided into 4 groups each containing 10 caries-free maxillary incisor teeth. Shear bond strength values were measured for the primed and non-primed enamel to which All-Bond 2 and Z-100 were applied. The following values(MPa) were obtained for the primed groups pretreated with 32 % phosphoric acid for 15 seconds. : Group 1 (10 seconds dried) $29.8{\pm}2.2$ ; Group 2(moistened) $26.8{\pm}5.4$. For the non-primed groups the values were: Group 3(10 seconds dried/primed) $27.6{\pm}5.0$ ; Group 4(mostened/primed) $28.2{\pm}3.5$. The data were subjected to statistical analysis using ANOVA. The results showed that mean shear bond strengths among the experimental groups were not statistically different. (p>0.05) Conclusively, It is suggested that the bonding ability to enamel is not decreased by the moistening and priming of the enamel.

  • PDF

QUANTITATIVE COMPARISON OF PERMEABILITY IN THE ADHESIVE INTERFACE OF FOUR ADHESIVE SYSTEMS (열순환 후 상아질 접착 계면의 수분 투과성 변화에 대한 정량적 분석)

  • Chang, Ju-Hea;Yi, Kee-Wook;Kim, Hae-Young;Lee, In-Bog;Cho, Byeong-Hoon;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.1
    • /
    • pp.51-60
    • /
    • 2009
  • The purpose of this study was to perform quantitative comparisons of water permeable zones in both the adhesive and the hybrid layer before and after thermo cycling in order to assess the integrity of the bonding interface. Twenty eight flat dentin surfaces were bonded with a light-cured composite resin using one of four commercial adhesives [OptiBond FL (OP), AdheSE (AD), Clearfil SE Bond (CL). and Xeno III (XE)]. These were sectioned into halves and subsequently cut to yield 2-mm thick specimens; one specimen for control and the other subjected to thermocycling for 10,000 cycles. After specimens were immersed in ammoniacal silver nitrate for 24 h and exposed to a photo developing solution for 8 h, the bonded interface was analyzed by scanning electron microscopy (SEM) and wavelength dispersive spectrometry (WDS) at five locations per specimen. Immediately after bonding. the adhesive layer of OP showed the lowest silver uptake, followed by CL, AD. and XE in ascending order (p < 0.0001); the hybrid layer of CL had the lowest silver content among the groups (p = 0.0039). After thermocycling, none of the adhesives manifested a significant increase of silver in either the adhesive or the hybrid layer. SEM demonstrated the characteristic silver penetrated patterns within the interface. It was observed that integrity of bonding was well maintained in OP and CL throughout the thermocycling process. Adhesive-tooth interfaces are vulnerable to hydrolytic degradation and its permeability varies in different adhesive systems, which may be clinically related to the restoration longevity.

THE COMPARATIVE STUDY ON THE COLOR OF THE DECIDUOUS TEETH AND RESTORATIVE MATERIALS (유치의 치아색과 수복재의 색조선택에 관한 비교연구)

  • Baik, Byeong-Ju;Oh, Kyoung-Seon;Kim, Jae-Gon;Yang, Cheol-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.3
    • /
    • pp.376-381
    • /
    • 2002
  • The purpose of this study was to analyse the color of natural deciduous teeth in Korean children and to compare with that of composite resin specimens. The subjects were 148 children (80 boys and 68 girls) with good general condition and normal teeth color, aged between 3 and 6 years. The color of middle third of maxillary central incisor in deciduous teeth was examined with shade guide and then measured by means of the colorimeter CV300 which can be measured by CIELAB system. The data were analyzed statistically by SPSS program. The results were summerized as follows; 1. Over 90% of the color for the deciduous anterior teeth was in A1, A2, B1, B2 and P shade. 2. The means of deciduous teeth color were $L^*=58.72,\;a^*=-1.18,\;b^*=-0.63$ by colorimeter CV300. 3. $L^*,\;a^*\;and\;b^*$ prices for A1, A2, B1, B2, P were $L^*=52.52,\;a^*=-1.90,\;b^*=1.18$ in A1 specimen, $L^*=54.90,\;a^*=-1.87,\;b^*=1.60$ in A2 specimen, $L^*=59.80,\;a^*=-2.70,\;b^*=-0.63$ in B1 specimen, $L^*=56.90,\;a^*=-1.70,\;b^*=1.63$ in B2 specimen, $L^*=52.93,\;a^*=-2.33,\;b^*=1.10$ in P specimen. The means of B1 color specimen were most similar to those of deciduous teeth color. The A1 color values were similar to the P color values. 4. The standard deviation of $L^*,\;a^*$ was small among colors, but that of $b^*$, in the yellowish color, was large.

  • PDF

THE EFFECT OF THERMOCYCLING ON THE DURABILITY OF DENTIN ADHESIVE SYSTEMS (열순환이 상아질 접착제의 결합 내구성에 미치는 영향)

  • Moon, Young-Hoon;Kim, Jong-Ryul;Choi, Kyung-Kyu;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.222-235
    • /
    • 2007
  • The objectives of this study was to evaluate the effect of thermocycling on the ${\mu}TBS$ (microtensile bond strength) to dentin with four different adhesive systems to examine the bonding durability. Freshly extracted $3^{rd}$ molar teeth were exposed occlusal dentin surfaces, and randomly distributed into 8 adhesive groups 3-steps total-etching (Scotchbond Multi-Purpose Plus; SM, All Bond-2; AB), 2-steps total-etching (Single Bond; SB, One Step plus; OS), 2-steps self-etching (Clearfil SE Bond; SE, AdheSE AD) and single-step self-etching systems (Promp L-Pop; PL, Xeno III; XE) Each adhesive system in 8 adhesives groups was applied on prepared dentin surface as an instruction and resin composite (Z250) was placed incrementally and light-cured. The bonded specimens were sectioned with low-speed diamond saw to obtain $1\times1mm$ sticks after 24 hours of storage at $37^{\circ}C$ distilled water and proceeded thermocycling at the pre-determined cycles of 0, 1,000 and 2,000. The ${\mu}TBS$ test was carried out with EZ-tester at 1mm/min. The results of bond strength test were statistically analyzed using one-way ANOVA/ Duncan's test at the a < 0.05 confidence level. Also, the fracture mode of debonded surface and the interface were examined under SEM. The results of this study were as follows ; 1. 3-step total etching adhesives showed stable, but bond strength of 2-step adhesives were decreased as thermocycling stress. 2. SE showed the highest bond strength, but single step adhesives (PL, XE) had the lowest value both before and after thermocycling. 3 Most of adhesives showed adhesive failure. The total-etching systems were prone to adhesive failure and the single-step systems were mixed failure after thermocycling. Within limited results of this study, the bond strength of adhesive system was material specific and the bonding durability was affected by the bonding step/ procedure of adhesive Simplified bonding procedures do not necessarily imply improved bonding performance.

Influence of the curing time for the adhesive on the oxygen-inhibited layer thickness and the shear bond strength to dentin (광조사 시간이 접착제의 표면 미중합층의 두께와 전단접착강도에 미치는 영향에 관한 연구)

  • Choi, Yong-Hoon;Bae, Ji-Hyun;Son, Ho-Hyun;Lee, In-Bog;Um, Chung-Moon;Baek, Seung-Ho;Kim, Oh-Young;Kim, Chang-Keun;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.2
    • /
    • pp.177-184
    • /
    • 2004
  • Objectives : This study investigated the hypothesis that increasing light-curing time would leave the oxygen-inhibited layer (OIL) of the adhesive thinner, and in turn, result in lower shear bond strength (SBS) than those obtained by the routine curing procedures. Methods:120 human extracted posterior teeth were randomly divided into three groups for bonding with three adhesives:All Bond 2/sup (R)/, One Step/sup (R)/, and Adper Prompt/sup (R)/. They were subsequently divided into four subgourps with different light-curing time (10, 20, 30 and 60s). The assigned adhesives were applied on superficial occlusal dentin according to the manufacturer's instructions and cured with one of the four curing times. Composite resin cylinder, 2.35㎜ in diameter, were built on the cured adhesive and light-cured for 40s. SBS were measured after 24h from the bonding using a universal testing machine (crosshead speed 1.0 ㎜/min). The relative thickness of the OIL and the degree of conversion (DC) were determined from the adhesive on a slide glass using FT-NIR in an absorbance mode. Data were analysed with One-way ANOVA and Duncan's multiple test (p〈0.05), Results:With increasing cure time, although there were no significant difference in th SBS of One-step and Adper Prompt (p〉0.05), those of All Bond 2 decreased significantly (p〈0.05). The relative thicknesses of the OIL on each adhesive were not affected by the cure time (p〉0.05). Although the DC of All-Bond 2 were statistically not different with increasing cure time (p〉0.05), those of One-Step and Adper Prompt showed an increasing trends with increasing cure time (p〈0.05). Conclusions:Increasing light-curing time did not affect on the relative thickness of the OIL of the adhesives, and in turn, on the SBS to dentin.

MICROTENSILE BOND STRENGTH OF ALL-IN-ONE ADHESIVE TO CARIES-AFFECTED DENTIN (우식이환 상아질에 대한 all-in-one adhesive의 미세인장결합강도)

  • Moon, Ji-Deok;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.1
    • /
    • pp.49-57
    • /
    • 2005
  • The purpose of this study was to evaluate the effect of multiple application of all-in-one dentin adhesive system on microtensile bond strength to caries-affected dentin. Twenty one extracted human molars with occlusal caries extending into mid-dentin were prepared by grinding the occlusal surface flat. The carious lesions were excavated with the aid of caries detector dye. The following adhesives were applied to caries-affected dentin according to manufacturer's directions; $Scotchbond^{TM}$ Multi-Purpose in SM group, Adper Prompt $L-Pop^{TM}$ 1 coat in LP1 group, 2 coats in LP2 group, 3 coats in LP3 group, $Xeno^{(R)}$ III 1 coat in XN1 group, 2 coats in XN2 group. and 3 coats in XN3 group. After application of the adhesives, a cylinder of resin-based composite was built up on the occlusal surface. Each tooth was sectioned vertically to obtain the $1{\times}1\;mm^2$ sticks. The microtensile bond strength was determined. Each specimen was observed under SEM to examine the failure mode. Data were analyzed with one-way ANOVA. The results of this study were as follows; 1. The microtensile bond strength values were; SM ($14.38{\pm}2.01$ MPa), LP1 ($9.15{\pm}1.81$ MPa), LP2(14.08{\pm}1.75$ MPa), LP3 ($14.06{\pm}1.45$ MPa). XN1 (13.65{\pm}1.95$ MPa). XN2 ($13.98{\pm}1.60$) MPa, XN3 ($13.88{\pm}1.66$) MPa, LP1 was significantly lower than the other groups in bond strength (p < 0.05). All groups except LP1 were not significantly different in bond strength (p > 0.05). 2. In LP1, there were a higher number of specimens showing adhesive failure. Most specimens of all groups except LP1 showed mixed failure.