• Title/Summary/Keyword: Restoration wear

Search Result 98, Processing Time 0.021 seconds

Metal stain on monolithic zirconia restoration: A case report

  • Cha, Min-Sang;Lee, Sang-Woon;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.2
    • /
    • pp.138-142
    • /
    • 2017
  • In restorative treatment using fixed dental prostheses, dentists should select appropriate restoration material among various types of dental materials. The strength, marginal fit, esthetics, wear resistance, biocompatibility, and cost are important factors in the choice of restoration materials. The present case showed a surface stain on a monolithic zirconia restoration that was due to wear between the monolithic zirconia restoration and the base metal alloy restoration. This phenomenon was confirmed by surface roughness measurement and electron probe micro-analysis.

Wear resistance of indirect composite resins used for provisional restorations supported by implants

  • Tsujimoto, Akimasa;Jurado, Carlos;Villalobos-Tinoco, Jose;Barkmeier, Wayne;Fischer, Nicholas;Takamizawa, Toshiki;Latta, Mark;Miyazaki, Masashi
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.4
    • /
    • pp.232-238
    • /
    • 2019
  • PURPOSE. The aim of this study was to investigate simulated localized and generalized wear of indirect composite resins used for implant supported provisional restorations. MATERIALS AND METHODS. The study investigated ten indirect composite resins. Two kinds of wear were simulated by 400,000 cycles in a Leinfelder-Suzuki (Alabama) machine. Localized wear was simulated with a stainless-steel ball bearing antagonist and generalized with a flat-ended stainless-steel cylinder antagonist. The tests were carried out in water slurry of polymethyl methacrylate beads. Wear was measured using a Proscan 2100 noncontact profilometer in conjunction with Proscan and AnSur 3D software. RESULTS. Both localized and generalized wear were significantly different (P<.05) among the indirect composite resins. SR Nexco and Gradia Plus showed significantly less wear than the other indirect composite resins. The rank order of wear was same in both types of wear simulation. CONCLUSION. Indirect composite resins are recommended when a provisional implant-supported restoration is required to function in place over a long period. Although only some indirect composite resins showed similar wear resistance to CAD/CAM composite resins, the wear resistance of all the indirect composite resins was higher than that of bis-acryl base provisional and polymethyl methacrylate resins.

Full mouth rehabilitation of an asthma patient with severe tooth wear and occlusion disharmony (심한 마모 및 교합 부조화를 가진 천식 환자의 전악 수복 증례)

  • Jo, Yu-Jin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.22 no.4
    • /
    • pp.225-230
    • /
    • 2022
  • Objectives: Patients with excessive tooth wear should first be diagnosed for the etiology of the tooth wear. Causes of tooth wear include bruxism, clenching, and taking medications for systemic diseases. After identifying the cause of tooth attrition, the final prosthesis should be restored with an appropriate vertical dimension. Methods: A 79-year-old man with worn out teeth desired a whole dental treatment. He was on medications for high blood pressure and asthma. The treatment proceeded with a consultation with a medical doctor. The medications for asthma evoked multiple teeth wear and a loss of the vertical dimension. After recovery of 3 mm of vertical dimension, 2 months of evaluation was followed by an interim prosthesis. Results: The increased vertical dimension caused no problem in function and esthetics, and the final restoration was performed with a full monolithic zirconia crown. Group function, adequate anterior guidance, and the occlusal plane were determined. Conclusions: After the final restoration, the patient was both esthetically and functionally satisfied, and a night guard splint was delivered to prevent prosthesis fracture. The patient was informed about the potential tooth wear associated with asthma drugs and educated to visit the clinic regularly.

Assessment of Wear Resistance in Tooth-Colored Materials for Primary Molar Crown Restoration in Pediatric Dentistry

  • Hyun Seok Kang;Yooseok Shin;Chung-Min Kang;Je Seon Song
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.51 no.1
    • /
    • pp.22-31
    • /
    • 2024
  • The objective of this study was to assess the wear resistance of tooth-colored materials used in crown restoration for primary molars with a chewing simulator. In this study, four groups-three experimental groups and one control group-were included. They consisted of three-dimensional (3D) printed resin crowns (NextDent and Graphy), milled nano-hybrid ceramic crowns (MAZIC Duro), and prefabricated zirconia crowns (NuSmile). Twelve mandibular second molar specimens were prepared from each group. In the wear experiment, 6.0 × 105 cycles were conducted with a force of 50 N, and a 6 mm-diameter steatite ball was used as an antagonist. The amount of wear was calculated by comparing the scan files before and after the chewing simulation using 3D metrology software, and the worn cross-section was confirmed by scanning electron microscopy (SEM). The resin and ceramic groups did not exhibit any statistically significant differences. However, compared to other crown groups, the zirconia crown group demonstrated notably reduced levels of wear (p < 0.05). In SEM images, layers and cracks were observed in the 3D-printed resin crown groups, which differed from those in the other groups.

In vitro wear behavior between enamel cusp and three aesthetic restorative materials: Zirconia, porcelain, and composite resin

  • Jang, Yong-Seok;Nguyen, Thuy-Duong Thi;Ko, Young-Han;Lee, Dae-Woo;Baik, Byeong Ju;Lee, Min-Ho;Bae, Tae-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.1
    • /
    • pp.7-15
    • /
    • 2019
  • PURPOSE. The aim of this study was to identify the effects of three aesthetic restorative materials on the wear between tooth and restoration by a pin-on-disk manner. MATERIALS AND METHODS. Six aesthetic restorative materials were used to prepare disk specimens for wear test, which were Lava Zirconia as zirconia group, Vintage MP and Cerabien ZR as veneering porcelain group, Gradia Direct microhybrid composite containing prepolymerized fillers, Filtek Z250 microhybrid composite containing zirconia glass and colloidal silica particles, and Filtek Z350 nanocomposite as composite resin group. Vertical loss of the worn cusp, change of the surface roughness of the restoration materials, and the surface topography were investigated after wear test under 9.8-N contact load. RESULTS. The porcelain groups (Vintage MP and Cerabien ZR) caused the largest vertical loss of teeth when compared with those of the composite resin and zirconia groups, and Filtek Z250 microhybrid composite results in the second-largest vertical loss of teeth. The surface of Filtek Z350 nanocomposite was deeply worn out, but visible wear on the surface of the zirconia and Gradia Direct microhybrid composite was not observed. When the zirconia surface was roughened by sand-blasting, vertical loss of teeth considerably increased when compared with that in the case of fine polished zirconia. CONCLUSION. It was identified that microhybrid composite resin containing a prepolymerized filler and zirconia with reduced surface roughness by polishing were the most desirable restorative materials among the tested materials to prevent the two-body wear between aesthetic restorative material and tooth.

Full mouth rehabilitation with vertical increase in patient with severe tooth wear using monolithic zirconia prosthetic restoration (과도한 치아마모를 보이는 환자에서 수직교합고경의 증가를 동반한 단일구조 지르코니아 보철물 전악수복)

  • Bang, Ji Won;Kim, Seong-A;Lim, Sun Yong;Lee, Yong-Sang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.369-377
    • /
    • 2020
  • Gradual teeth wear is normal physiological progress, severe tooth wear can causes dysfunction, occlusal plane disharmony and esthetic problems. If additional space is needed for prosthetic restoration due to severe attrition, full mouth rehabilitation with increase of occlusal vertical dimension may be considered. In this case, 72 year old male patient with severe worn dentition, irregular gingival zenith and deep anterior bite was treated by full mouth rehabilitation for regaining the space for restoration, improving relationship and esthetic of anterior teeth. Provisional restoration obtained by systemic analysis, diagnosis and re-evaluation for a sufficient time was replicated to final restorations through double scanning technique using monolithic zirconia blocks. Satisfactory functional and esthetic outcomes were obtained.

Full Mouth Rehabilitation in Severely Worn Dentition (심한 교모증 환자의 완전 구강 회복)

  • Jung, Jae-Hyun;Choi, Min-Ho;Park, Young-Rok;Kim, Chang-Heon;Kang, Dong-Wan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.3
    • /
    • pp.247-256
    • /
    • 2003
  • The patient had bruxism and epilepsy tendency. Inadequate or unstable posterior support was identified due to severe anterior attrition and decreased occlusal vertical dimension. Prematurities of posterior occlusal and wear facets increased the function of anterior teeth, resulting in severe wear. Wear facets displayed sharply defined peripheries, which are matched on articulated diagnostic casts. Also the patient showed C III malocclusion tendency, and lost some facial contour with drooping corners on the mouth. In this case, the alteration of OVD (Occlusal Vertical Dimention) may provide a biologically compatible adjunct to the treatment such as dentofacial esthetics, improved visual proportion in facial heightand mechanical solutions to the force-management of the masticatory system. The patient requires extensive restorative treatment to regain appropriate function, esthetics and comfort. According to the report by Farhad Fays, the average vertical distance from the maxillary to the mandibular mucolabial reflection in the region of the central incisors is approximately 34mm. However, the vertical distance of this patient was found to be 32mm, which was necessary to add gauge 20-sheets to apply vertical dimension. A removable occlusal overlay splint, which restores OVD to the estimated optimalposition, is the general first trial. The patient was observed periodically for 6 weeks, while appropriate adjustments were made vertical dimension to function. When patient felt comfortable with the splint, the teeth were prepared, and provisional restorations are placed for 3 months. The provisional restoration was fabricated by a diagnostic wax-up. When the patient felt comfortable with the provisional restoration, the final restoration mimics OVD, function, and esthetics that have been developed in the treatment restorations. Restoration of the extremely worn dentition presents a substantial challenge to thedentists. Therefore, careful evaluation of the etiology, history, and factors associated with occlusal vertical dimension should be preceded prior to the appropriate treatment planning.

Effect of Carbon-Restoration on Mechanical Properties of Automobile Safety Parts (자동차용 안전부품의 기계적 성질에 미치는 복탄처리의 영향)

  • Kim, M.G.;Jung, B.H.;Jung, S.H.;Lee, B.C.;Kim, S.S.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.16 no.1
    • /
    • pp.26-31
    • /
    • 2003
  • Decarburized zone of metal tongue which is used in seat belt for automobiles was carbon-restoration quenched and tempered using nitrogen-methanol gaseous atmosphere. The effects of microstructure and mechanical properties of metal tongue on the effectiveness of carbon-restoration during tempering was studied. Metal tongue showed $20{\sim}30{\mu}m$ decarburized zone. However, after carbon-restoration, it has uniform microstructure and thus hardness without decarburized zone. Carbon-restoration quenching and tempering process resulted in better wear and corrosion resistances than quenching and tempering process.

Wear of 3D printed and CAD/CAM milled interim resin materials after chewing simulation

  • Myagmar, Gerelmaa;Lee, Jae-Hyun;Ahn, Jin-Soo;Yeo, In-Sung Luke;Yoon, Hyung-In;Han, Jung-Suk
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.3
    • /
    • pp.144-151
    • /
    • 2021
  • PURPOSE. The purpose of this in vitro study was to investigate the wear resistance and surface roughness of three interim resin materials, which were subjected to chewing simulation. MATERIALS AND METHODS. Three interim resin materials were evaluated: (1) three-dimensional (3D) printed (digital light processing type), (2) computer-aided design and computer-aided manufacturing (CAD/CAM) milled, and (3) conventional polymethyl methacrylate interim resin materials. A total of 48 substrate specimens were prepared. The specimens were divided into two subgroups and subjected to 30,000 or 60,000 cycles of chewing simulation (n = 8). The wear volume loss and surface roughness of the materials were compared. Statistical analysis was performed using one-way analysis of variance and Tukey's post-hoc test (α=.05). RESULTS. The mean ± standard deviation values of wear volume loss (in mm3) against the metal abrader after 60,000 cycles were 0.10 ± 0.01 for the 3D printed resin, 0.21 ± 0.02 for the milled resin, and 0.44 ± 0.01 for the conventional resin. Statistically significant differences among volume losses were found in the order of 3D printed, milled, and conventional interim materials (P<.001). After 60,000 cycles of simulated chewing, the mean surface roughness (Ra; ㎛) values for 3D printed, milled, and conventional materials were 0.59 ± 0.06, 1.27 ± 0.49, and 1.64 ± 0.44, respectively. A significant difference was found in the Ra value between 3D printed and conventional materials (P=.01). CONCLUSION. The interim restorative materials for additive and subtractive manufacturing digital technologies exhibited less wear volume loss than the conventional interim resin. The 3D printed interim restorative material showed a smoother surface than the conventional interim material after simulated chewing.

Full mouth rehabilitation of the patient with severely worn dentition: a case report

  • Song, Mi-Young;Park, Ji-Man;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.3
    • /
    • pp.106-110
    • /
    • 2010
  • The severe wear of anterior teeth facilitates the loss of anterior guidance, which protects the posterior teeth from wear during excursive movement. The collapse of posterior teeth also results in the loss of normal occlusal plane and the reduction of the vertical dimension. This case report describes 77-year-old female, who had the loss of anterior guidance, the severe wear of dentition, and the reduction of the vertical dimension. Occlusal overlay splint was used after the decision of increasing vertical dimension by anatomical landmark, facial and physiologic measurement. Once the compatibility of the new vertical dimension had been confirmed, interim fixed restoration and the permanent reconstruction was initiated. This case reports that a satisfactory clinical result was achieved by restoring the vertical dimension with an improvement in esthetics and function.