• 제목/요약/키워드: Restarting method

검색결과 24건 처리시간 0.041초

유닛모듈 운반시 작용하중 분석 (Load analysis for transporting unit module)

  • 김균태;전영훈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.200-201
    • /
    • 2015
  • The unit modular method is one in which unit modules are prefabricated at a factory and then constructed at a construction site. That is why an important process, transporting unit module, is added in this method. The purpose of this study is to analyse the load for transporting unit module. The results of the analysis of the driving experimental runs revealed that a maximum load of 15 kN was applied on adapter block type A and a maximum load of 25 kN on adapter block type B. These loads were recorded at the points in the road test when the low-bed trailer was driving through unstable sections of the test such as stopping, restarting, passing over a speed bump or taking a left turn at speed.

  • PDF

전달관로 요소를 이용한 가변스텝 시뮬레이션 (Variable step size simulation using transmission line element)

  • 황운규;조승호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.682-687
    • /
    • 2000
  • In this paper, the simulation methods using transmission lines are studied and realized, which are necessary in design and analysis of hydraulic control systems. The basic idea of this method is that system components are separated by transmission line element for simulation. The PI-controller can keep inductance level as low as desired. It can also handle nonlinearities and discontinuities without flag signal when restarting integration. Parallel hydraulic circuits are simulated using parallel processing algorithm. To shoe that using variable timestep size in each subsystem, simulation time can be reduced. Performance of the simulation results is compared with that of Runge Kutta method.

  • PDF

순간전압강하 보상 알고리즘을 이용한 인버터 제어에 관한 연구 (The Inverter Control Method Using The Voltage Sag Compensation algorithm)

  • 윤홍민;배진용;김용
    • 조명전기설비학회논문지
    • /
    • 제26권12호
    • /
    • pp.62-67
    • /
    • 2012
  • In this paper general purpose voltage source inverter drives are equipped with an under-voltage protection mechanism, causing the system to shut down within a few milliseconds after a power interruption in the main input sources. When a power interruption occurs finish, if the system is a large inertia restarting the load a long time is required. This paper suggests modifications in the control algorithm in order to improve the sag ride-through performance of ac inverter. The new proposed strategy recommends maintaining the DC-link voltage constant at the nominal value during a sag control algorithm, experimental results are presented.

HID 램프 수명 연장을 위한 적응형 점화기 개발 (Development of the Adaptive Igniter for Expanding HID Lamp Life)

  • 박종연;조계현;송명석
    • 산업기술연구
    • /
    • 제24권A호
    • /
    • pp.75-81
    • /
    • 2004
  • The metal halide lamps are now widely used in the application and commercial lighting due to their attracting properties such as good color rendering and high efficiency. But, they have the serious problem of acoustic resonance for high frequency operation and they need the high voltage to ignite. So, they have not been applied to indoors. Over the past few years, a considerable number of studies have been conducted on the electronic ballast together with hot restarting and resonance phenomenon. But, very few attempts have been made with the adaptive ignition method according to the lamp state. In this paper, electronic ballast is proposed for metal halide lamps with an igniter for adaptive ignition. The proposed electronic ballast can generate different ignition voltages according to the arc tube state.

  • PDF

네트워크 시스템 생존성 : 소프트웨어 재활기법을 이용한 TCP의 프레임워크 (Network System Survivability: A Framework of Transmission Control Protocol with Software Rejuvenation Methodology)

  • Khin Mi Mi Aung;Park, Jong-Sou
    • 한국정보보호학회:학술대회논문집
    • /
    • 한국정보보호학회 2003년도 하계학술대회논문집
    • /
    • pp.121-125
    • /
    • 2003
  • In this paper, we propose a framework of Transmission Control Protocol with Software Rejuvenation methodology, which is applicable for network system survivability. This method is utilized to improve the survivability because it can limit the damage caused by successful attacks. The main objectives are to detect intrusions in real time, to characterize attacks, and to survive in face of attacks. To counter act the attacks' attempts or intrusions, we perform the Software Rejuvenation methods such as killing the intruders' processes in their tracks, halting abuse before it happens, shutting down unauthorized connection, and responding and restarting in real time. These slogans will really frustrate and deter the attacks, as the attacker can't make their progress. This is the way of survivability to maximize the deterrence against an attack in the target environment. We address a framework to model and analyze the critical intrusion tolerance problems ahead of intrusion detection on Transmission Control Protocol (TCP).

  • PDF

HID 램프 수명 연장을 위한 점화기 개발 (Development of the Igniter to Expand HID Lamp Life)

  • 조계현;송명석;박종연
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권7호
    • /
    • pp.370-376
    • /
    • 2004
  • The metal halide lamps are now widely used in the application and commercial lighting due to their attracting properties such as good color rendering and high efficiency. But, they have the serious problem of acoustic resonance for high frequency operation and they need the high voltage to ignite. So, they have not been applied to indoors. Over the past few years, a considerable number of studies have been conducted on the electronic ballast together with hot restarting and resonance phenomenon. But, Very few attempts have been made with the adaptive ignition method according to the lamp state. In this paper, electronic ballast is proposed for metal halide lamps with an igniter for adaptive ignition. The proposed electronic ballast can generate different ignition voltages according to the arc tube state.

램프 상태 적응형 점등 방법에 관한 연구 (The Study on Adaptive ignition for HID lamps according to lamp state)

  • 조계현;송명석;박종연
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.205-209
    • /
    • 2004
  • The metal halide lamps are now widely used in the application and commercial lighting due to their attracting properties such as good color rendering and high efficiency. But they have the serious problem of acoustic resonance for high frequency operation and they need the high voltage to ignite. So, they have not been applied to indoors. Over the past few years, a considerable number of studies have been conducted on the electronic ballast together with hot restarting and resonance phenomenon. But very few attempts have been made with the adaptive ignition method according to the lamp state. In this paper, electronic ballast is proposed for metal halide lamps with an igniter for adaptive ignition. The proposed electronic ballast can generate different ignition voltages according to the arc tube state.

  • PDF

영구자석 동기전동기 센서리스 구동 시스템의 구동 재개 방법 (Restarting Method for PMSM Sensorless Drive Systems)

  • 이영재;서동우;박영수;이교범
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.12-14
    • /
    • 2018
  • 본 논문은 영구자석 동기전동기(PMSM) 센서리스 구동 시스템의 구동 재개 방법을 제안한다. PMSM의 센서리스 구동 시스템에서는 일반적으로 전동기의 역기전력을 기반으로 회전자의 속도와 위치를 추정한다. 하지만 PMSM이 회전 중인 상태에서 인버터의 동작이 중단된 경우에 구동을 재개하기 위해서는 회전자의 초기 속도 및 위치 정보가 필요하다. 따라서 본 논문에서는 인버터의 영전압 벡터를 인가하여 발생된 전류를 이용해 회전자의 초기 속도 및 위치 정보를 추정하는 PMSM 센서리스 구동 시스템의 구동 재개 방법을 제안한다. 제안하는 방법의 타당성은 시뮬레이션을 통해 검증한다.

  • PDF

HID 램프를 위한 상태 적응형 점화기 설계 방법 (Design Method of Adaptive Ignitor for HID Lamps)

  • 조계현;송명석;박종연
    • 조명전기설비학회논문지
    • /
    • 제18권3호
    • /
    • pp.7-14
    • /
    • 2004
  • 현재까지 HID 램프는 광원이 가진 많은 장점에도 불구하고, 고온 순시 재 점등과 음향 공명 현상으로 인해서 실내 광원으로서의 사용이 제한되어왔다. 하지만 많은 연구를 통해서 램프가 뜨거운 상태에서도 순시 재 점등이 가능한 방법이 제시되어 왔고, 실제로 사용되어지고 있다. 하지만 이러한 방법은 램프 상태와 무관하게 200[kV] 정도의 전압을 램프에 인가하는 방법으로, 일반적으로 램프 수명이 감소하는 특징을 가지고 있다. 그러므로 순시 재 점등과 수명 문제는 중요한 연구대상으로 인식되어왔다. 본 논문에서는 램프가 차가운 상태에 필요한 점화 전압과 램프가 뜨거운 상태에서 점등에 필요한 점화 전압을 발생시키는 독립적인 2개의 점화기를 사용함으로써, 램프 상태에 따라 각기 다른 점화 전압을 램프에 인가하는 방법을 제안하고자 한다.

멀티레벨 인버터의 순간정전 보상알고리즘에 관한 연구 (Voltage Dip Compensation Algorithm Using Multi-Level Inverter)

  • 윤홍민;김용
    • 조명전기설비학회논문지
    • /
    • 제27권12호
    • /
    • pp.133-140
    • /
    • 2013
  • Cascaded H-Bridge multi-level inverters can be implemented through the series connection of single-phase modular power bridges. In recent years, multi-level inverters are becoming increasingly popular for high power applications due to its improved harmonic profile and increased power ratings. This paper presents a control method for balancing the dc-link voltage and ride-through enhancement, a modified pulse width-modulation Compensation algorithm of cascaded H-bridge multi-level inverters. During an under-voltage protection mechanism, causing the system to shut down within a few milliseconds after a power interruption in the main input sources. When a power interruption occurs finish, if the system is a large inertia restarting the load a long time is required. This paper suggests modifications in the control algorithm in order to improve the sag ride-through performance of ac inverter. The new proposed strategy recommends maintaining the DC-link voltage constant at the nominal value during a sag period, experimental results are presented.