• Title/Summary/Keyword: Response to Disaster

Search Result 1,008, Processing Time 0.031 seconds

A Study on Creation of Secure Storage Area and Access Control to Protect Data from Unspecified Threats (불특정 위협으로부터 데이터를 보호하기 위한 보안 저장 영역의 생성 및 접근 제어에 관한 연구)

  • Kim, Seungyong;Hwang, Incheol;Kim, Dongsik
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.4
    • /
    • pp.897-903
    • /
    • 2021
  • Purpose: Recently, ransomware damage that encrypts victim's data through hacking and demands money in exchange for releasing it is increasing domestically and internationally. Accordingly, research and development on various response technologies and solutions are in progress. Method: A secure storage area and a general storage area were created in the same virtual environment, and the sample data was saved by registering the access process. In order to check whether the stored sample data is infringed, the ransomware sample was executed and the hash function of the sample data was checked to see if it was infringed. The access control performance checked whether the sample data was accessed through the same name and storage location as the registered access process. Result: As a result of the experiment, the sample data in the secure storage area maintained data integrity from ransomware and unauthorized processes. Conclusion: Through this study, the creation of a secure storage area and the whitelist-based access control method are evaluated as suitable as a method to protect important data, and it is possible to provide a more secure computing environment through future technology scalability and convergence with existing solutions.

Experimental Analysis on Regularities of Synergistic Interaction of Temperature with Physico-Chemical Environmental Factors (온도와 물리화학적 환경요인에 의한 상승작용의 규칙성에 관한 실험적 고찰)

  • 김진규;신해식;블라디슬라프페틴;이영엽
    • Korean Journal of Environmental Biology
    • /
    • v.20 no.2
    • /
    • pp.165-172
    • /
    • 2002
  • The combined action of two factors on organisms can be either antagonistic, non-effective, additive or synergistic. Although synergism is of biological importance, the common features of synergistic interaction between harmful environmental factors are largely unknown. The purpose of this study is to establish general rules describing the response of various organisms to the combined action of heat with another inactivating agent. Synergistic interaction due to the simultaneous treatment of hyperthermia with ionizing or non-ionizing radiation has been analyzed using the experimental data mainly obtained with yeast cells. In addition, the results reported by others for viruses, bacterial spores, cultured mammalian cells, plants and animals were also analyzed to check the regularities revealed. The common rules of the synergistic interaction obtained in this study can be summarized as follows. For any constant rate of exposure, the synergy can be observed only within a certain temperature range. An increase in exposure rate resulted in an increase of this specific temperature and vice versa. For a constant temperature at which the irradiation occurs, synergy can be observed within a certain dose rate range. As the exposure temperature is reduced, the optimal intensity decreases and vice versa. A new conception taken into consideration those regularities can make a clue for environmental disaster preventive analysis of the synergy of radiation with the other factor.

Estimation of Tidal Residual Flow and Its Variability in Kyunggi Bay of Korea (경기만 조석 잔차류 산정 및 변동성)

  • Kim, Chang-S.;Lim, H.S.;Kim, Jin-Ah;Kim, Seon-Jeong;Park, K.S.;Jung, K.T.
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.22 no.6
    • /
    • pp.353-360
    • /
    • 2010
  • The Kyunggi Bay in mid-west of Korea is a relatively large estuarine system that connects the Han River system with Yellow Sea. Due to macro-tidal range of more than 8 m, the urban estuary shows deep tidal channels and wide tidal flats. Since last 30 years, the coastal development is undergoing, yielding noticeable change in environment. Particularly the tidal flat dynamics are generally accepted as being related with tidal residual flows in this area (Kim et al., 2009). We have estimated the annual variation and vertical structure of residual currents with one-year long observed flows in two major tidal channels of Kyunggi Bay. The moving average method and tidal current harmonic analysis yield nearly the same results on residual flow. The residual flow in Jangbong channel ranges from 20 cm/s in summer to 30 cm/s in winter. It is noticeable that the residual flow in Jangbong channel is flood dominant throughout the year, while the flow in Seokmo channel is ebb-dominant residual flow with current speed range of 20-40 cm/s. Due to the baroclinic response of relatively shallow estuary, significant reduction of energy in bottom layers have been observed, indicating the importance of residual circulation to the tidal flat behavior.

A study on Fire Case and Countermeasure of Tourist Hotel (관광호텔의 화재손해 위험관리방안 - 화재발생현황과 대형화재사례 분석 중심)

  • Han, Sukman;Son, Jung Hyoun;Kim, Jong Won
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.4
    • /
    • pp.362-375
    • /
    • 2012
  • Tourist hotels are equipped with facilities such as accommodation and restaurants, exercise, recreation. Unspecified guests, visitors and management of tourist hotels are very vulnerable on the casualties and property losses due to fire peril exist. In this study, we analysis that the fire statistics status of tourist hotels from 2001 to 2010. And the 15 cases of a large hotel fire are reviewed. The total number of fires on hotel are consist of a hotel rooms fire(33.2%), a restaurant kitchen fire(11.8%). And the major causes of the fire are an electrical fire (40.8%), a cigarette fire (14.5%) and a hot-work fire (9.2%). In case study, the fire wall defect and combustible materials are major fire loss causes for 10year. Each tourist hotels are needed a development of suitable fire risk management and a field operations. A hotel is required an active fire risk management on a preventive inspection, an education and training, and a preventive maintenance. It is necessary that a fire wall maintenance to prevent of the spread of a fire and a sprinkler installation of whole area to protect fire. And it is very important an emergency response for evacuation of guest, and operate emergency procedures on a fire or emergency situation.

A Study on Model for Social Return for the Prevention of Recidivism of Sexual Violence Criminals Based on Big Data (빅데이터 기반 성폭력범죄자 재범방지를 위한 사회지원모델에 관한 연구)

  • Oh, Sei Youen
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.3
    • /
    • pp.535-542
    • /
    • 2021
  • Purpose: The purpose of this study is to prevent recidivism by recognizing the seriousness of recidivism against sexual offenders under the age of 13 and providing customized social adaptation services based on risk. Method: The study evaluate the efficiency of existing models and proposed model systems, and compare and review what features and operational differences exist from existing models. Result: The proposed model will collect data from related agencies on sexual violence offenders with a high risk of recidivism and classify them into three risk groups through risk algorithms to provide social adaptation services for each risk group. In addition, by monitoring primary social support matching data, storing and re-analyzing the results data to rematch social support services, the model differs from the existing model in preventing recidivism of sexual violence offenders from a long-term perspective. Conclusion: The proposed model of this study is meaningful in that it proposed the basic data of a response system to prevent recidivism from a long-term perspective of sexual offenders with the highest risk of recidivism by collecting and analyzing data on sexual offenders.

A Study on the Causes and Improvement Plans for Firefighters' Casualty Accidents During Rescue Activities related to the Water - 4M Analysis - (수난구조활동 중 소방공무원 순직사고의 원인과 대응방안에 관한 연구 - 4M분석기법을 중심으로 -)

  • Park, Chanseok
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.4
    • /
    • pp.710-721
    • /
    • 2021
  • Purpose: The purpose of this study is to prepare an environment that can provide high-quality 119 rescue services by analyzing the causes of casualties at the water rescue and suggesting improvement plans to prevent them. Method: 5 major cases were analyzed among firefighters' casualty accidents during rescue activities related to the water over the past 10 years for case study. And the causes of the accidents were analyzed in terms of 4 values (Man, Machine, Media, Management) through the 4M analysis technique. Result: ① man: the main causes are lack of awareness of on-site safety, etc ② machine: the problem of the absence of the equipment itself, etc ③ media: the lack of information on the rescue site and the poor rescue environment conditions, ④ management : the main causes were the absence and inadequacy of the response manual for each rescue site, Conclusion: ① man: knowledge of SOP and reinforcement of education and training, etc. ② machine: there are measures such as the introduction of equipment suitable for the changing rescue site, ③media: providing sufficient information about the rescue activity environment and conducting regular road training, ④ management: policy suggestions such as establishment and dissemination of on-site safety management plans and manuals were derived.

A Study on the Watershed Analysis of the Expected Flood Inundation Area in South Han River (남한강 유역의 침수예상지역에 대한 홍수범람분석에 관한 연구)

  • HONG, Sung-Soo;JUNG, Da-Som;HWANG, Eui-Ho;CHAE, Hyo-Suk
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.19 no.1
    • /
    • pp.106-119
    • /
    • 2016
  • Flood risk map, flood damage map, disaster information map, inundation trace map are involved with the cartographic analysis of flood inundation based on prevention, preparation, restoration, response from natural disasters such as flood, flooding, etc. In this study, the analysis for channel and basin characteristics Chungju dam to Paldang dam of South han river after four river project. Flood scenario is selected to take advantage of design flood level of schematic design for river. Flood inundation of one dimensional non-uniform flow by using HEC-RAS with basin characteristics is accomplished and two dimensional unsteady flow was interpreted by using FLUMEN. Frequency analysis is carried out about each abundance of South han river for 100 year period, 200 year period and 500 year period. Flooding disaster area of 100 year period on 0.5m damage functions is 2378.8ha, 200 year period on 0.5m damage functions is 3155.2ha, 500 year period on 0.5m damage functions is 3995.3ha respectively. It will be significant data for decision making to establish inundation trace map for providing basic plan for river maintenance, land use plan, flood protection plan, application plan and getting information of flood expectation area.

Applicability of Water Resource Specialized Satellites for Observing Disasters on the Korean Peninsula (한반도 수재해 관측을 위한 수자원 위성의 적용성)

  • KIM, Dong-Young;BAECK, Seung-Hyub;PARK, Gwang-Ha;HWANG, Eui-Ho;CHAE, Hyo-Sok
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.1
    • /
    • pp.85-97
    • /
    • 2017
  • In recent years, the damage scales of water disasters such as typhoons, tsunamis, and heavy snow have been increasing globally as a result of global warming and climate changes. In particular, the economic loss caused by typhoons has been increasing for overpopulated areas that have undergone economic development and urbanization since the 1960s. In this study, we investigated and analyzed satellite images captured before and after typhoons on the Korean peninsula, including Typhoon Chaba (2016), Typhoon Rusa ('02), and Typhoon Maemi ('03). There was a limitation in utilizing existing satellites. Domestic satellites have mostly been developed and operated for the observation of the weather, ocean, and topography, as well as for use in communication. There are therefore insufficient temporal and spatial observations for water management and disaster response. In this work, we expanded the scope to overseas satellites and collected data from GMS, TRMM, COMS, and GPM. In the future, it will be necessary to develop and launch water resources satellites that can provide sufficient temporal and spatial data analysis units to obtain rapid and accurate water hazard information for the Korean peninsula.

Derivation of Building Fire Safety Assessment Factors for Generating 3D Safety Status Map (3D 안전상태지도 제작을 위한 건물 화재안전 평가항목 도출)

  • Youn, Junhee;Kim, Taehoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.40-47
    • /
    • 2020
  • Various technologies, systems, and legal systems are applied to prevent and quickly respond to fire disaster; nevertheless, the damages to life and property caused by fires are not reduced every year. For managing fire disaster, generating spatial information-based safety status map and procuring suitability of attribute information for each position information are essential. The safety status map is generated by deriving the fire safety status assessment factors, indexing, and locating the surveying results through various methods. In this paper, we deal with derivation of building fire safety assessment factors for 3D safety status map. At first, we survey the foreign and domestic fire assessment model cases and its factors, and analyze the applicability of Korean 3D fire safety status map. Next, assessment factors for fire safety assessment model are derived. Assessment factors are derived and categorized by their information collecting activity; factors that can be accessed through basic building information and factors that can be accessed through field survey. As a derivation result, 14 assessment factors were derived over five categories(Industry Risk, Structural Risk, Fire Fighting Facility, Fire Dangerousness, Fire Response Status).

Operation Scheduling in a Commercial Building with Chiller System and Energy Storage System for a Demand Response Market (냉각 시스템 및 에너지 저장 시스템을 갖춘 상업용 빌딩의 수요자원 거래시장 대응을 위한 운영 스케줄링)

  • Son, Joon-Ho;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.312-321
    • /
    • 2018
  • The Korean DR market proposes suppression of peak demand under reliability crisis caused a natural disaster or unexpected power plant accidents as well as saving power plant construction costs and expanding amount of reserve as utility's perspective. End-user is notified a DR event signal DR execution before one hour, and executes DR based on requested amount of load reduction. This paper proposes a DR energy management algorithm that can be scheduled the optimal operations of chiller system and ESS in the next day considering the TOU tariff and DR scheme. In this DR algorithm is divided into two scheduling's; day-ahead operation scheduling with temperature forecasting error and operation rescheduling on DR operation. In day-ahead operation scheduling, the operations of DR resources are scheduled based on the finite number of ambient temperature scenarios, which have been generated based on the historical ambient temperature data. As well as, the uncertainties in DR event including requested amount of load reduction and specified DR duration are also considered as scenarios. Also, operation rescheduling on DR operation day is proposed to ensure thermal comfort and the benefit of a COB owner. The proposed method minimizes the expected energy cost by a mixed integer linear programming (MILP).