• 제목/요약/키워드: Response correction factor

검색결과 98건 처리시간 0.023초

STATCON 제어방식에 따른 특성 연구 (A Study on the Characteristics of Control Schemes for STATCON)

  • 한영성;차재덕;홍순욱;이학성;문건우;윤석호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2076-2078
    • /
    • 1998
  • This paper presents STATCON(Static Condenser) control schemes for voltage regulation, power factor correction and harmonics mitigation. Each control scheme can be applied in the system depending on the system requirements. The 20KVA STATCON is developed and tested in the reduced system model for the verification of three different control algorithms. The results of proposed controls are compared for power factor correction and voltage regulation algorithms. For each algorithm, harmonic mitigation scheme is adopted as a part of control. Finally verification of STATCON for the transient response is implemented by voltage flicker test.

  • PDF

Analytical solutions to piezoelectric bimorphs based on improved FSDT beam model

  • Zhou, Yan-Guo;Chen, Yun-Min;Ding, Hao-Jiang
    • Smart Structures and Systems
    • /
    • 제1권3호
    • /
    • pp.309-324
    • /
    • 2005
  • This paper presents an efficient and accurate coupled beam model for piezoelectric bimorphs based on improved first-order shear deformation theory (FSDT). The model combines the equivalent single layer approach for the mechanical displacements and a layerwise modeling for the electric potential. General electric field function is proposed to reasonably approximate the through-the-thickness distribution of the applied and induced electric potentials. Layerwise defined shear correction factor (k) accounting for nonlinear shear strain distribution is introduced into both the shear stress resultant and the electric displacement integration. Analytical solutions for free vibrations and forced response under electromechanical loads are obtained for the simply supported piezoelectric bimorphs with series or parallel arrangement, and the numerical results for various length-to-thickness ratios are compared with the exact two-dimensional piezoelasticity solution. Excellent predictions with low error estimates of local and global responses as well as the modal frequencies are observed.

An Optimized PI Controller Design for Three Phase PFC Converters Based on Multi-Objective Chaotic Particle Swarm Optimization

  • Guo, Xin;Ren, Hai-Peng;Liu, Ding
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.610-620
    • /
    • 2016
  • The compound active clamp zero voltage soft switching (CACZVS) three-phase power factor correction (PFC) converter has many advantages, such as high efficiency, high power factor, bi-directional energy flow, and soft switching of all the switches. Triple closed-loop PI controllers are used for the three-phase power factor correction converter. The control objectives of the converter include a fast transient response, high accuracy, and unity power factor. There are six parameters of the controllers that need to be tuned in order to obtain multi-objective optimization. However, six of the parameters are mutually dependent for the objectives. This is beyond the scope of the traditional experience based PI parameters tuning method. In this paper, an improved chaotic particle swarm optimization (CPSO) method has been proposed to optimize the controller parameters. In the proposed method, multi-dimensional chaotic sequences generated by spatiotemporal chaos map are used as initial particles to get a better initial distribution and to avoid local minimums. Pareto optimal solutions are also used to avoid the weight selection difficulty of the multi-objectives. Simulation and experiment results show the effectiveness and superiority of the proposed method.

한반도 남부 지진의 지역 규모식 (The ML scale in southern Korea)

  • 홍태경
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.73-80
    • /
    • 2000
  • The distance correction term -logA0 of the local magnitude scale was estimated for earthquakes in southern Korea using linear least-squares inversion and interpolation scheme. Total 1054 short-period velocity seismograms from 107 local events recorded at hypocentral distances ranging from 10 to 480 km were used in this study. Simulated Wood-Anderson amplitudes were obtained from velocity seismograms with use of revised Wood-Anderson instrument response with static magnification 2080, damping factor 0.7, and natural period 0.8 sec. The estimated distance correction term for southern Korea is found to be -logA0=1.137 log(r/17) + 0.001159(r-17) + 20, where r is hypocentral distance in kilometers. The attenuation rate of this distance correction term falls between those of southern California and eastern North America.

  • PDF

진단방사선촬영에서 광자극형광선량계의 에너지의존성에 대한 보정인자 (Correction Factor for the Eenergy Dependence of a Optically Stimulated Luminescent Dosimeter in Diagnostic Radiography)

  • 김종언;임인철;이효영
    • 한국방사선학회논문지
    • /
    • 제5권5호
    • /
    • pp.261-265
    • /
    • 2011
  • 이 연구의 목적은 진단방사선촬영에서 환자의 피부선량을 측정하는 나노도트선량계의 에너지의존성에 대한 보정인자들을 구하는 것이다. 보정인자들은 랜다우어사에서 제공한 팬텀 정에 관한 X-선에 상대적인 선량계의 에너지반응그래프와 로사도 등이 발표한 IEC의 RQR 표준방사선 품질들에 대한 평균에너지 값들을 사용하여 구하였다. 결과들은 관전압 40-150 kVp에서 1-1.33의 보정인자들을 나타냈다. 얻어진 보정인자들은 각 관전압에서 정확한 피부선량 측정을 위하여 임상에 사용하는데 유용할 것으로 생각된다.

수평면 전일사량 측정데이터 보정에 관한 실험적 연구 (An Experimental Study on the Scale Correction of Measured Horizontal Global Solar Radiation)

  • 송수원
    • 한국태양에너지학회 논문집
    • /
    • 제30권5호
    • /
    • pp.25-31
    • /
    • 2010
  • A Precision Spectral Pyranometer (PSP) is mainly used as a reference to calibrate other pyranometers due to its high accuracy and sensitivity in response to the spectrum wavelength range of 0.285 ${\mu}$ to 2.8 ${\mu}$, while the sensitivity of photovoltaic-type Li-Cor pyranometer is limited within a certain spectral range from 0.4 ${\mu}$ to 1.1 ${\mu}$. In this study, two Eppley PSPs($PSP_1$ and $PSP_2$) were first compared to the calibrated Eppley PSPs from National Renewable Energy Laboratory (NREL), resulting in two linear correction factors based on the comparison between the logger output (V) from the test PSP and the solar radiation (W/m2) from the NREL PSP. The Li-Cor pyranometer used in this study was then corrected based on the comparison of measured solar radiation ($W/m^2$) from the corrected $PSP_1$ and the Li-Cor pyranometer. In addition, instrument scale corrections were also performed for the PSPs and the Li-Cor from the transmitter to the data logger. From the comparisons, a linear correction factor (1.0214) with R=0.9998 was developed for the scale correction between$PSP_1$ and $PSP_2$, while the Li-Cor pyranometer has a scale(1.0597) and offset (32.046) with R=0.9998 against$PSP_1$. As a result, it was identified that there were good agreements within ${\pm}$ 10 W/ $m^2$ between Eppley $PSP_1$ vs. $PSP_2$ solar radiation and within ${\pm}$ 20 W/$m^2$ between$PSP_1$ vs Li-Cor solar radiation after the empirical scale corrections developed in this study.

Digital Control of an AC/DC Converter using the Power Balance Control Technique with Average Output Voltage Measurement

  • Wisutmetheekorn, Pisit;Chunkag, Viboon
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.88-97
    • /
    • 2012
  • This paper presents a method for the digital control of a high power factor AC/DC converter employing the power balance control technique to achieve a fast response of the output voltage control. To avoid the effects of an output voltage ripple in the voltage control loop, the average output voltage is sampled and used as a feedback signal for the output voltage controller. The proposed control technique was verified by simulations using MATLAB/Simulink and its implementation was realized by a dsPIC30F4011 digital signal processor to control a CUK topology AC/DC converter with a 48V output voltage and a 250 W output power. The experimental results agree with the simulation results. The proposed control technique achieves a fast transient response with a lower line current distortion than is achieved when using a conventional proportional-integral controller and the power balance control technique with the conventional sampling method.

Collimator Detector Response(CDR) 회복이 적용된 SPECT/CT에서 검출거리에 따른 정량적 정확성 평가 (The Evaluation of Quantitative Accuracy According to Detection Distance in SPECT/CT Applied to Collimator Detector Response(CDR) Recovery)

  • 김지현;손현수;이주영;박훈희
    • 핵의학기술
    • /
    • 제21권2호
    • /
    • pp.55-64
    • /
    • 2017
  • 최근 SPECT/CT의 보급과 함께 다양한 영상보정 방법들을 빠르고 정확하게 적용할 수 있게 되면서, 영상품질 향상과 더불어 정량적 정확성까지 기대할 수 있게 되었다. 그중 Collimator Detector Response (CDR) 회복(recovery)은 검출기면의 거리로부터 발생된 blurring 효과를 보상하여 분해능 회복을 목적으로 하는 보정방법이다. 본 연구에서는 SPECT/CT 영상에서 CDR recovery 가 적용되었을 때 검출거리 변화에 따른 정량적 변화를 알아보고자 하였다. 검출거리의 변화에 따른 획득 계수의 차이를 알아보고자 검출거리를 궤도방식(obit type)에 따라 Circular는 X, Y축 반경 30 cm, Non-Circular는 X, Y축 반경 21 cm, 10 cm, Non-Circular Auto(=Auto Body Contouring_ ABC, spacing limit 1 cm)로 설정하였고, 재구성 방법은 CDR recovery(CDRr)의 사용 유/무에 따른 계수 회복 차이를 알아보고자 OSEM (w/o CDRr)와 Astonish(3D-OSEM with CDRr)로 구분하여 적용하였다. 이 때 감쇠, 산란, 붕괴 보정은 모든 영상에 공통 적용하였다. 정량적 평가를 위해 교정인자(calibration factor_CF) 산출을 목적으로 교정영상(cylindrical phantom, $^{99m}TcO_4$ 123.3 MBq, 물 9293 ml)을 획득하였고, 팬텀 실험을 위하여 50 cc 주사기에 물 31 ml를 채우고 $^{99m}TcO_4$ 123.3 MBq를 설정하여 팬텀영상을 획득하였다. 팬텀 영상에서 주사기 전체 체적에 VOI(volume of interest)를 설정하여 각 조건별로 총 계수 값을 측정하였고, CF를 적용시켜 설정된 참값 대비 추정값의 오차를 구하여 보정에 따른 정량적 정확성을 확인하였다. 산출된 CF는 154.27 (Bq/ml/cps/ml)이며, 각 조건별 영상에서 참값 대비 추정값은 OSEM에서 Circular 86.5%, Non-Circular 90.1%, ABC 91.3% Astonish에서 Circular 93.6%, Non-Circular 93.6%, ABC 93.9%으로 분석되었다. OSEM은 검출거리가 가까울수록 정확성이 높아졌으며, Astonish의 경우에는 거리와 상관없이 거의 유사한 값을 나타내었다. 오차는 OSEM Circular(-13.5%)에서 가장 크고, Astonish ABC(-6.1%)에서 가장 적었다. SPECT/CT영상에서 CDR recovery 적용을 통한 거리보상이 이루어 졌을 때 검출거리가 먼 조건에서도 근접검출과 거의 동일한 정량적 정확성을 보였고, 검출거리의 변화에 영향을 받지 않고 정확한 보정이 가능한 것을 확인 할 수 있었다.

  • PDF

한국 표준설계스펙트럼의 감쇠보정계수에 대한 연구 (A Study on the Damping Correction Factors for the Korean Standard Design Spectrum)

  • 허태민;김정한;이진호;김재관
    • 한국지진공학회논문집
    • /
    • 제22권1호
    • /
    • pp.1-14
    • /
    • 2018
  • In this study, we develop and propose damping correction factors for the Korean standard design spectra. The newly proposed Korean standard design spectra has been given only for 5% damping ratio. But in practice, engineers need design spectra for damping values other than 5%. To obtain design spectra for various damping values from the standard spectra, damping correction factors are derived. These factors modify the shape of design spectra in accordance with the damping ratio. Response spectra for various damping values are calculated from the earthquake records that had been used to calculate standard design spectra. They consist of 55 records from 18 earthquakes occurred in overseas intraplate regions and Korea. The regressed spectra for the damping values ranging from 0.5% to 50 % are compared with standard spectra at three regions acceleration, velocity and displacement sensitive regions. The regression analysis of these data rendered formula for damping correction factors. Finally, a single formula for damping correction factors is recommended that is valid for both horizontal and vertical design spectra and that is applicable to the entire range of periods. One thing to note that recommended damping correction factors is valid for the design spectrum of the rock grounds because the design spectra was developed based on the earthquake records of the rock ground.

유색잡음 매개변수가진과 외부가진을 받는 확률 시스템의 응답해석 (RESPONSE ANALYSIS OF A STOCHSTIC UNDER PARAMETRIC ND EXTERNL EXCITATION HAVING COLORED NOISE CHARACTERISTICS)

  • 허훈;백종한;오진형
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1993년도 추계학술대회논문집; 반도아카데미, 26 Nov. 1993
    • /
    • pp.55-59
    • /
    • 1993
  • Interaction between system and disturbance results in system with time-dependent parameter. Parameter variation due to interaction has random characteristics. Most of the randomly varying parameters in control problem is regarded as white noise random process, which is not a realistic model. In real situation those random variation is colored noise random process. Modified F-P-K equation is proposed to get the response of the random parametric system using some correction factor. Proposed technique is employed to obtain the colored noise parametric system response and confirmed via Monte-Carlo Simulation.

  • PDF